Filter by
Fluke Wireless Remote-Reading Clamp-on-Jaw Current Meters
![]() |
Take current measurements from a distance with these high-quality, durable Fluke meters. They wirelessly transmit readings to a separate display. Because the jaws surround a cable, these meters are convenient for taking frequent measurements since you don't have to interrupt the circuit.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
True RMS AC Calculation—These true RMS current meters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 1,000-count meter shows numbers up to 999. A higher display count means the meter can give a more precise measurement.
Mfr. Model No. | Test End Component | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Current, amp | Data Log Cap. | Display Count | Includes | Certification | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a3000 FC | Current Clamp | 1.33" | CAT III, 600V | AC Current | 400 | 65,000 | 1,000 | — | CSA Certified, CSA-US Certified | Yes | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a3001 FC | Current Loop | 10" | CAT IV, 600V | AC Current | 2,500 | 65,000 | 2,500 | Magnetic Hanger | CSA Certified, CSA-US Certified | Yes | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Sensors
![]() |
Model Number 80BK-A |
Take temperature readings with a Fluke multimeter.
Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
Mfr. Model No. | For Fluke Model No. | Temp. Range, ° F | Test End Component | Connection End | Cord Lg. | Test End Insulation Material | Each | ||
---|---|---|---|---|---|---|---|---|---|
80BK-A | 28 II, 87V, 116, 179, 233, 287, 289 | -40 to 500 | Needle Tip | Sheathed Standard Banana Jack | 39" | PTFE | 0000000 | 000000 |
Computer Connectors for Fluke Wireless Remote-Reading Meters
![]() |
Plug this connector into a computer to receive wirelessly-transmitted measurements from a Fluke wireless meter. Analyze measurements in real-time with the included software.
The connector works with the Fluke 3000 FC multimeter, Fluke Wireless Remote-Reading Clamp-On Current Meters, and Fluke Wireless Remote-Reading Voltage Meters.
Mfr. Model No. | For Fluke Model No. | Includes | Data Log Cap. | Each | ||
---|---|---|---|---|---|---|
pc3000 FC | 3000 FC, a3000 FC, a3001 FC, v3000 FC, v3001 FC | Windows 7 Software | 65,000 | 00000000 | 0000000 |
Fluke Wireless Remote-Reading Voltage Meters
![]() |
Measure voltage from a distance with these wireless connection-enabled meters that transmit readings to a separate display. Fluke is known for quality and durability.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
True RMS AC Calculation—The true RMS meter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. These 1,000-count meters show numbers up to 999.
Batteries | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | AC Calculation | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | Display Type | Display Features | Data Log Cap. | Display Count | Includes | Certification | Req. | Included | Each | ||
v3000 FC | True RMS | CAT IV, 600V | AC Voltage | 1,000 | — | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 0000000 | |
v3001 FC | — | CAT IV, 600V | DC Voltage | — | 1,000 | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 000000 |
Data-Logging Multimeters
![]() |
Identify intermittent issues such as voltage spikes and temporary power flow problems—these meters record measurements from electrical tests over time. Review data in real time or save it for future analysis.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Data Log Cap. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
50,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | 10,000 | Alligator Clips, Test Leads | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Wireless Remote-Reading Multimeters
![]() |
Model Number 3000 FC |
A wireless connection transmits electrical measurements from the multimeter to a separate display, so you can take measurements in hard-to-reach or potentially dangerous locations. Fluke multimeters are known for quality and durability.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Model Number 3000 FC—Model number 3000 FC uses built-in Bluetooth connectivity to transmit measurements to a computer with a Fluke pc3000 FC connector plugged in (not included) or to a mobile device that has the Fluke Connect app. The multimeter also receives measurements from Fluke Wireless Remote-Reading Clamp-On Current Meters and Fluke Wireless Remote-Reading Voltage Meters (not included).
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3000 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.09% | 400 | 400 | Lead Storage, Overload Protection | 6,000 | Alligator Clips, Test Leads | 000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Clamp-on-Jaw Multimeters
![]() |
Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters with Calibration Certificate | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
381 | 1.34" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads | 00000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||