About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Equipment-Cooling Vortex Tubes
Vortex tubes convert compressed air into a stream of cold air. Use them to keep heat-sensitive electronic equipment cool with cold air. They have no moving parts for a long service life. Note: Air supply must be filtered to remove moisture and contaminants.
Airflow adjusters (sold separately) can be switched out to increase or decrease the vortex tube's airflow (cfm) to alter its cooling capacity.
Mufflers (sold separately) reduce the sound level to protect your hearing.
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Air Outlet | Airflow Adjusters | Cold-Air Mufflers | |||||||||||||
Airflow, cfm | Cooling Cap., Btu/hr. | Volume, dBA | Overall Lg. | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Min. Operating Temp., °F | Each | Each | Each | |||
303 Stainless Steel | ||||||||||||||||
2 | 135 | 68 | 4 1/8" | 1/8 | NPT | Male | 1/4 | NPT | Female | -20° | 00000000 | 0000000 | 00000000 | 000000 | 00000000 | 000000 |
4 | 275 | 70 | 4 1/8" | 1/8 | NPT | Male | 1/4 | NPT | Female | -20° | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
8 | 550 | 76 | 4 1/8" | 1/8 | NPT | Male | 1/4 | NPT | Female | -20° | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
10 | 650 | 80 | 5 5/8" | 1/4 | NPT | Male | 3/8 | NPT | Female | -20° | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
15 | 1,000 | 81 | 5 5/8" | 1/4 | NPT | Male | 3/8 | NPT | Female | -20° | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
25 | 1,700 | 82 | 5 5/8" | 1/4 | NPT | Male | 3/8 | NPT | Female | -20° | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
30 | 2,000 | 84 | 5 5/8" | 1/4 | NPT | Male | 3/8 | NPT | Female | -20° | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
40 | 2,800 | 88 | 5 5/8" | 1/4 | NPT | Male | 3/8 | NPT | Female | -20° | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
Equipment-Cooling Vortex Tube Kits
Kits include one vortex tube for converting compressed air into a stream of cold air as well as airflow adjusters, a cold-air muffler, a tube fitting, and tubing. Use them to keep heat-sensitive electronic equipment cool with cold air. The vortex tube has no moving parts for a long service life. Note: Air supply must be filtered to remove moisture and contaminants.
Air Inlet | Air Outlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Cooling Cap., Btu/hr. | Overall Lg. | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Min. Operating Temp., °F | Includes | Each | |
303 Stainless Steel | ||||||||||||
2, 4, 8 | 135, 275, 550 | 4 1/8" | 1/8 | NPT | Male | 1/4 | NPT | Female | -20° | One Vortex Tube Three Airflow Adjusters One Cold-Air Muffler One Tube Fitting Tubing | 00000000 | 0000000 |
10, 15, 25, 30, 40 | 650, 1,000, 1,700, 2,000, 2,800 | 5 5/8" | 1/4 | NPT | Male | 3/8 | NPT | Female | -20° | One Vortex Tube Five Airflow Adjusters One Cold-Air Muffler One Tube Fitting Tubing | 00000000 | 000000 |
Filter | 0000000 | Each | 0000000 |
Enclosure-Cooling Vortex Tubes
Vortex tubes convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Dia. | Ht. | For Opening Dia. | Each | Each | ||
Aluminum—NEMA 12 | |||||||||||||
400 | 5 | 1/8 | NPT | Male | 80-100 | 53 | 7/8" | 7 1/16" | 1 1/8" | 0000000 | 0000000 | 0000000 | 0000000 |
900 | 15 | 1/4 | NPT | Female | 80-100 | 75 | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 000000 | 0000000 | 000000 |
1,500 | 25 | 1/4 | NPT | Female | 80-100 | 75 | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 85 | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 000000 | 0000000 | 000000 |
Low-Noise Enclosure-Cooling Vortex Tubes with Thermostats
Often used in low-noise environments such as labs and clean rooms, these are quieter than standard enclosure-cooling vortex tubes. Set the thermostat and the tubes switch on only when needed. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Vortex tubes with dual air outlets have a higher cooling capacity than other vortex tubes. Use them to cool large enclosures and electronics that generate significant heat. Direct the two air streams independently for targeted cooling. With two air mufflers and two ducting lines, these vortex tubes take up slightly more space in your enclosure than vortex tubes with one air outlet.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume | Ht. | Wd. | Dp. | Environmental Rating | Includes | Each | Each | ||
With Nonadjustable Thermostat (80° to 90° F) | |||||||||||||||
Plastic—NEMA 12 | |||||||||||||||
900 | 15 | 3/8 | NPT | Female | 90-100 | 60 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Ducting Kit, Inline Compressed Air Filter | 0000000 | 0000000 | 0000000 | 0000000 |
1,500 | 25 | 3/8 | NPT | Female | 90-100 | 66 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Ducting Kit, Inline Compressed Air Filter | 0000000 | 000000 | 0000000 | 000000 |
2,500 | 35 | 3/8 | NPT | Female | 90-100 | 72 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Ducting Kit, Inline Compressed Air Filter | 0000000 | 000000 | 0000000 | 000000 |
5,000 | 70 | 3/8 | NPT | Female | 90-100 | 75 dBA | 8" | 4 3/4" | 3 9/16" | NEMA 12 | Dual Air Outlets, Ducting Kit, Inline Compressed Air Filter | 0000000 | 00000000 | 0000000 | 000000 |
Enclosure-Cooling Vortex Tubes with Thermostats
Set the thermostat and these vortex tubes switch on only when needed. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Replacement filters are sold separately.
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Frequency | Dia. | Ht. | For Opening Dia. | Each | Each | ||
With Adjustable Thermostat (50° to 140° F) | ||||||||||||||||
Aluminum—NEMA 12 | ||||||||||||||||
400 | 5 | 1/8 | NPT | Male | 80-100 | 53 | 120V AC | Wire Leads | 60Hz | 7/8" | 7 1/16" | 1 1/8" | 0000000 | 000000000 | 0000000 | 0000000 |
900 | 15 | 1/4 | NPT | Female | 80-100 | 75 | 120V AC | Wire Leads | 60Hz | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 00000000 | 0000000 | 000000 |
1,500 | 25 | 1/4 | NPT | Female | 80-100 | 75 | 120V AC | Wire Leads | 60Hz | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 85 | 120V AC | Wire Leads | 60Hz | 1 3/4" | 10 3/4" | 1 1/8" | 0000000 | 00000000 | 0000000 | 000000 |
Low-Noise Washdown Enclosure-Cooling Vortex Tubes with Thermostats
In addition to being quieter than standard enclosure-cooling vortex tubes, these stand up to washdowns and weather. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. Set the thermostat and the tubes switch on only when needed. All include a ducting kit to distribute cool air throughout the enclosure and air mufflers to reduce noise. They also have an inline compressed air filter, which prevents moisture from building up inside the enclosure to further safeguard electronics.
Vortex tubes with dual air outlets have a higher cooling capacity than other vortex tubes. Use them to cool large enclosures and electronics that generate a lot of heat. Direct the two air streams independently for targeted cooling. With two air mufflers and two ducting lines, these vortex tubes take up more space than vortex tubes with one air outlet.
Vortex tubes with an electric thermostat require a 120V AC outlet. Those with an internal outlet are best for areas where external outlets are not available or where it would be unsafe to have an external electrical connection. Choose those with an external outlet if you need separate electrical connections for the thermostat and the electronics within an enclosure. Replacement filters are sold separately.
Air Inlet | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Ht. | Wd. | Dp. | For Opening Dia. | Environmental Rating | Features | Each | |
Plastic—NEMA 4 | ||||||||||||||
900 | 15 | 3/8 | NPT | Female | 90-100 | 60 | 8" | 4 3/4" | 5 3/8" | 1 15/16" | NEMA 4 | __ | 0000000 | 000000000 |
1,500 | 25 | 3/8 | NPT | Female | 90-100 | 66 | 8" | 4 3/4" | 5 3/8" | 1 15/16" | NEMA 4 | __ | 0000000 | 00000000 |
2,500 | 35 | 3/8 | NPT | Female | 90-100 | 72 | 8" | 4 3/4" | 5 3/8" | 1 15/16" | NEMA 4 | __ | 0000000 | 00000000 |
5,000 | 70 | 3/8 | NPT | Female | 90-100 | 75 | 6 3/8" | 9 1/2" | 5 1/2" | 1 15/16" | NEMA 4 | Dual Air Outlets | 0000000 | 00000000 |
Air Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Ht. | Wd. | Dp. | For Opening Dia. | Environmental Rating | Each | |
Internal Outlet | |||||||||||||||
Plastic—NEMA 4X | |||||||||||||||
900 | 15 | 3/8 | NPT | Female | 40-150 | 62-68 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 000000000 |
1,500 | 25 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
2,500 | 35 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
External Outlet | |||||||||||||||
Plastic—NEMA 4X | |||||||||||||||
900 | 15 | 3/8 | NPT | Female | 40-150 | 62-68 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
1,500 | 25 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
2,500 | 35 | 3/8 | NPT | Female | 40-150 | 62 | 120V AC | Plug | 6 7/16" | 9 7/16" | 5 9/16" | 1 15/16" | NEMA 4X | 0000000 | 00000000 |
Washdown Enclosure-Cooling Vortex Tubes with Thermostats
Set the thermostat and these vortex tubes switch on only when needed. Suitable for washdown applications, they are NEMA rated to resist washdowns. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure.
NEMA 4 rated vortex tubes resist dirt and washdowns.
NEMA 4X rated vortex tubes resist dirt, washdowns, and corrosion.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume | Dia. | Ht. | For Opening Dia. | Each | Each | ||
Aluminum—NEMA 4 | |||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 60 dBA to 79 dBA | 2 1/8" | 6 3/4" | 1 15/16" | 0000000 | 000000000 | 0000000 | 0000000 |
1,500 | 25 | 1/4 | NPT | Female | 80-100 | 60 dBA to 79 dBA | 2 1/8" | 6 3/4" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 60 dBA to 79 dBA | 2 1/8" | 6 3/4" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Frequency | Dia. | Ht. | For Opening Dia. | Each | Each | ||
304 Stainless Steel—NEMA 4X | ||||||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 71 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 000000000 | 0000000 | 0000000 |
1,700 | 25 | 1/4 | NPT | Female | 80-100 | 84 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
Aluminum—NEMA 4 | ||||||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 71 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
1,700 | 25 | 1/4 | NPT | Female | 80-100 | 84 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 120V AC | Wire Leads | 60Hz | 2" | 9 15/16" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
Washdown Enclosure-Cooling Vortex Tubes
Suitable for washdown applications, these vortex tubes are NEMA rated to resist washdowns. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure.
NEMA 4 rated vortex tubes resist dirt and washdowns.
NEMA 4X rated vortex tubes resist dirt, washdowns, and corrosion.
Replacement filters are sold separately.
Vortex Tubes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Ht. | Dia. | For Opening Dia. | Each | Each | ||
Aluminum—NEMA 4 | |||||||||||||
900 | 15 | 3/8 | NPT | Female | 80-100 | 71 | 9 15/16" | 2" | 1 15/16" | 0000000 | 0000000 | 0000000 | 0000000 |
1,500 | 25 | 3/8 | NPT | Female | 80-100 | 84 | 9 15/16" | 2" | 1 15/16" | 0000000 | 000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
304 Stainless Steel—NEMA 4X | |||||||||||||
900 | 15 | 1/4 | NPT | Female | 80-100 | 71 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
1,700 | 25 | 1/4 | NPT | Female | 80-100 | 84 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
2,500 | 35 | 1/4 | NPT | Female | 80-100 | 88 | 9 15/16" | 2" | 1 15/16" | 0000000 | 00000000 | 0000000 | 000000 |
Low-Noise Weather-Resistant Enclosure-Cooling Vortex Tubes
Quietly cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. They use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Diameter | Height | For Opening Diameter | Includes | Each | Each | ||
304 Stainless Steel—IP24, NEMA 3R | ||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 58 | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 0000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 60 | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 67 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 68 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 68 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 67 | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler | 0000000 | 000000 | 0000000 | 000000 |
Weather-Resistant Enclosure-Cooling Vortex Tubes
Cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | |||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Diameter | Height | For Opening Diameter | Environmental Rating | Includes | Each | Each | ||
304 Stainless Steel—IP24, NEMA 3R | |||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 64 | 1 1/8" | 6 1/2" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 0000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 66 | 1 1/8" | 6 1/2" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 72 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 73 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 74 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 76 | 1 1/2" | 10" | 1 1/8" | IP24, NEMA 3R | Automatic Water Drain Filter, Ducting Kit | 0000000 | 000000 | 0000000 | 000000 |
Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats
Cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Diameter | Height | For Opening Diameter | Includes | Each | Each | ||
With Adjustable Thermostat (-50° to 200° F) | ||||||||||||||||
304 Stainless Steel—IP24, NEMA 3R | ||||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 64 | 120V AC | Wire Leads | 1 1/8" | 6 1/2" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 0000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 66 | 120V AC | Wire Leads | 1 1/8" | 6 1/2" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 72 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 73 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 74 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 76 | 120V AC | Wire Leads | 1 1/2" | 10" | 1 1/8" | Automatic Water Drain Filter, Ducting Kit, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
Low-Noise Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats
Quietly cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. Using compressed air, they’re a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
Vortex Tubes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume, dBA | Voltage | Electrical Connection | Diameter | Height | For Opening Diameter | Includes | Each | Each | ||
With Adjustable Thermostat (-50° to 200° F) | ||||||||||||||||
304 Stainless Steel—IP24, NEMA 3R | ||||||||||||||||
200 | 4 | 1/8 | NPT | Male | 80-100 | 58 | 120V AC | Wire Leads | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 000000000 | 0000000 | 0000000 |
500 | 8 | 1/8 | NPT | Male | 80-100 | 60 | 120V AC | Wire Leads | 2 1/4" | 12 1/2" | 2 1/4" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
1,100 | 15 | 1/4 | NPT | Male | 80-100 | 67 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
1,800 | 25 | 1/4 | NPT | Male | 80-100 | 68 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,100 | 30 | 1/4 | NPT | Male | 80-100 | 68 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
2,900 | 40 | 1/4 | NPT | Male | 80-100 | 69 | 120V AC | Wire Leads | 2 13/16" | 16" | 2 13/16" | Automatic Water Drain Filter, Cold-Air Muffler, Ducting Kit, Hot-Air Muffler, Solenoid Valve | 0000000 | 00000000 | 0000000 | 000000 |
Hazardous Location Enclosure-Cooling Vortex Tubes
UL classified for hazardous locations, these vortex tubes convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. They chill compressed air by 50° F or more. These vortex tubes have a check valve that seals the air outlet when the unit is not in use, allowing the enclosure to be pressurized. All include a ducting kit to distribute cool air throughout the enclosure.
Vortex tubes with a cooling capacity of 5,000 Btu/hr. have dual air outlets that release two cold air streams. They’re good for cooling down large enclosures and electronics that generate a lot of heat. You can direct the air streams separately to target specific electronics. These vortex tubes take up more space inside of enclosures than those with a lower cooling capacity.
Replacement filters are sold separately.
Vortex Tubes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Overall | Replacement Filters | ||||||||||||
Cooling Cap., Btu/hr. | Airflow, cfm | Pipe Size | Thread Type | Gender | Required Air Pressure, psi | Volume @ Distance | Ht. | Wd. | Dp. | Environmental Rating | Each | Each | ||
With Nonadjustable Thermostat (80° to 90° F) | ||||||||||||||
Plastic | ||||||||||||||
900 | 15 | 3/8 | NPT | Female | 80-100 | 60 dBA @ 1 ft. | 8" | 4 3/4" | 5 3/8" | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 NEMA 4X | 0000000 | 000000000 | 0000000 | 0000000 |
2,500 | 35 | 3/8 | NPT | Female | 80-100 | 72 dBA @ 1 ft. | 8" | 4 3/4" | 5 3/8" | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 NEMA 4X | 0000000 | 00000000 | 0000000 | 000000 |
With Nonadjustable Thermostat (75° to 100° F) | ||||||||||||||
Plastic | ||||||||||||||
5,000 | 70 | 3/8 | NPT | Female | 90-100 | 75 dBA @ 1 ft. | 6 7/16" | 9 7/16" | 5 9/16" | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEMA 4X | 0000000 | 00000000 | 0000000 | 000000 |
Cold-Air Dispensers
Replace messy mist coolant dispensers—these convert compressed air into a stream of cold air. They can be used in applications where liquid coolant can't. Made with a vortex tube, these dispensers have no moving parts and need no electricity to provide a continuous supply of cold air. Dispensers have any-which-way nozzles that stay in place once positioned. All dispensers come with a filter to install in your air line.
Adjustable-temperature dispensers have a knob on the back to adjust the airflow.
For technical drawings and 3-D models, click on a part number.
Nozzle | Body | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Air Outlets | Airflow | Max. Pressure, psi | Lg. | Material | Mount Type | Bend Radius | No. of Dispensing Tips Included | Dia. | Lg. | Material | Vortex Tube Material | Air Temp. Reduction, °F | Each | |
Magnetic Mount | ||||||||||||||
Fixed Temperature | ||||||||||||||
1 | 4 cfm | 100 | 7 1/8" | Acetal Plastic | Threaded | 1 1/4" | 1 | 7/8" | 5 7/8" | Aluminum | Aluminum | 100° | 000000000 | 0000000 |
1 | 15 cfm | 100 | 11" | Acetal Plastic | Threaded | 1 5/8" | 2 | 1 1/2" | 10" | Aluminum | Stainless Steel | 50° | 0000000 | 000000 |
2 | 4 cfm | 100 | 8 1/8" | Acetal Plastic | Threaded | 1 1/4" | 2 | 7/8" | 5 7/8" | Aluminum | Aluminum | 100° | 000000000 | 000000 |
2 | 15 cfm | 100 | 11" | Acetal Plastic | Threaded | 1 1/4" | 4 | 1 1/2" | 10" | Aluminum | Stainless Steel | 50° | 0000000 | 000000 |
Adjustable Temperature | ||||||||||||||
1 | 2-15 fpm | 100 | 8 1/2" | Acetal Plastic | Threaded | 2 1/2" | 1 | 1 3/4" | 10 5/8" | Aluminum | Aluminum | 0° to 100° | 00000000 | 000000 |
1 | 18-35 fpm | 100 | 8 5/8" | Acetal Plastic | Threaded | 1 1/4" | 1 | 1 3/4" | 10 5/8" | Aluminum | Aluminum | 0° to 100° | 000000000 | 000000 |
2 | 2-15 fpm | 100 | 9" | Acetal Plastic | Threaded | 2 1/2" | 2 | 1 3/4" | 10 5/8" | Aluminum | Aluminum | 0° to 100° | 00000000 | 000000 |
2 | 18-35 fpm | 100 | 9" | Acetal Plastic | Threaded | 1 1/4" | 2 | 1 7/8" | 10 5/8" | Aluminum | Aluminum | 0° to 100° | 000000000 | 000000 |