Solenoid Valve Connectors
Connect hydraulic and air-powered valves, motors, pumps, and pressure switches.
IP65 rated connectors protect against water projected from a nozzle.
IP67 rated connectors protect against temporary submersion.
For technical drawings and 3-D models, click on a part number.


Thread | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Current | For Wire Gauge | For Cable OD | Cable Orientation | Color | Size | Pitch, mm | Thread Type | Pipe Size | Lg. | Wd. | Ht. | Features | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | |||||||||||||||||
120V AC/120V DC | |||||||||||||||||
2 | 8A | 20, 19, 18, 17, 16 | 0.24"-0.35" | __ | Black | PG-11 | __ | PG | __ | 1.08" | 1.35" | 1.69" | Power-Indicating Light | 190° | IP65 | 0000000 | 000000 |
230V AC/230V DC | |||||||||||||||||
2 | 10A | 20, 19, 18, 17, 16 | 0.31"-0.39" | __ | Black | __ | __ | NPT | 1/2 | 1.12" | 1.35" | 1.77" | __ | 250° | IP65 | 0000000 | 0000 |
2 | 10A | 20, 19, 18, 17, 16 | 0.31"-0.39" | __ | Gray | PG-11 | __ | PG | __ | 1.12" | 1.35" | 1.69" | __ | 250° | IP65 | 0000000 | 0000 |
3 | 10A | 20, 19, 18, 17, 16 | 0.31"-0.39" | __ | Black | __ | __ | NPT | 1/2 | 1.12" | 1.35" | 1.77" | __ | 250° | IP65 | 0000000 | 0000 |
3 | 10A | 20, 19, 18, 17, 16 | 0.31"-0.39" | __ | Black | PG-11 | __ | PG | __ | 1.12" | 1.35" | 1.69" | __ | 250° | IP65 | 0000000 | 0000 |
Type BI—0.43" (11 mm) Contact Distance | |||||||||||||||||
24V AC/24V DC | |||||||||||||||||
3 | 4A | 16, 15, 14, 13, 12 | 0.2"-0.39" | Opposite Ground Terminal | Gray | M16 | 1.5 | Metric | __ | 0.87" | 1.61" | 1.77" | Power-Indicating Light | 140° | IP65 | 00000000 | 00000 |
3 | 4A | 16, 15, 14, 13, 12 | 0.24"-0.32" | Opposite Ground Terminal | Gray | PG-9 | __ | PG | __ | 0.87" | 1.61" | 1.77" | Power-Indicating Light | 140° | IP65 | 00000000 | 00000 |
Type C—0.31" (8 mm) Contact Distance | |||||||||||||||||
250V AC/250V DC | |||||||||||||||||
2 | 6A | 20, 19, 18 | 0.18"-0.24" | __ | Black | PG-7 | __ | PG | __ | 0.62" | 1.02" | 1.1" | __ | 190° | IP65 | 0000000 | 0000 |
3 | 6A | 20, 19, 18 | 0.18"-0.24" | __ | Black | PG-7 | __ | PG | __ | 0.62" | 1.02" | 1.1" | __ | 190° | IP65 | 0000000 | 0000 |
Type CI—0.37" (9.4 mm) Contact Distance | |||||||||||||||||
250V AC/250V DC | |||||||||||||||||
2 | 6A | 20, 19, 18 | 0.18"-0.24" | __ | Black | PG-7 | __ | PG | __ | 0.62" | 1.02" | 1.1" | __ | 190° | IP65 | 0000000 | 0000 |
3 | 6A | 20, 19, 18 | 0.18"-0.24" | __ | Black | PG-7 | __ | PG | __ | 0.62" | 1.02" | 1.1" | __ | 190° | IP65 | 0000000 | 0000 |


Number of Poles | Current | Wire Lead Gauge | Cable Orientation | Cable Lead Lg., ft. | Color | Lg. | Wd. | Ht. | Features | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24V AC/24V DC | |||||||||||||
2 | 10A | 18 | __ | 6 | Gray | 1.09" | 1.05" | 1.94" | Power-Indicating Light | 175° | IP67 | 0000000 | 000000 |
2 | 10A | 18 | __ | 16 | Gray | 1.09" | 1.05" | 1.94" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
110V AC/110V DC | |||||||||||||
2 | 4A | 18 | __ | 6.5 | Black | 1.06" | 1.18" | 1.77" | Power-Indicating Light | 158° | IP67 | 0000000 | 00000 |
2 | 4A | 18 | __ | 16.5 | Black | 1.06" | 1.18" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
230V AC/230V DC | |||||||||||||
2 | 10A | 18 | __ | 6.5 | Black | 1.06" | 1.18" | 1.77" | __ | 158° | IP67 | 00000000 | 00000 |
2 | 10A | 18 | __ | 16.5 | Black | 1.06" | 1.18" | 1.77" | __ | 158° | IP67 | 00000000 | 00000 |
Type BI—0.43" (11 mm) Contact Distance | |||||||||||||
24V AC/24V DC | |||||||||||||
2 | 4A | 18 | With Ground Terminal | 6.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 4A | 18 | With Ground Terminal | 16.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
110V AC/110V DC | |||||||||||||
2 | 4A | 18 | With Ground Terminal | 6.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 4A | 18 | With Ground Terminal | 16.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
230V AC/230V DC | |||||||||||||
2 | 10A | 18 | With Ground Terminal | 6.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 10A | 18 | With Ground Terminal | 16.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
Type C—0.31" (8 mm) Contact Distance | |||||||||||||
24V AC/24V DC | |||||||||||||
2 | 4A | 18 | __ | 6.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 185° | IP67 | 0000000 | 00000 |
2 | 4A | 18 | __ | 16.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
2 | 4A | 20 | __ | 6 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
2 | 4A | 20 | __ | 16 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
110V AC/110V DC | |||||||||||||
2 | 4A | 18 | __ | 6.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 158° | IP67 | 0000000 | 00000 |
2 | 4A | 18 | __ | 16.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
Type CI—0.37" (9.4 mm) Contact Distance | |||||||||||||
24V AC/24V DC | |||||||||||||
2 | 4A | 18 | __ | 6.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 4A | 18 | __ | 16.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 4A | 20 | __ | 6 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
2 | 4A | 20 | __ | 16 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
110V AC/110V DC | |||||||||||||
2 | 4A | 18 | __ | 6.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |


Length | Width | Height | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Current | Wire Lead Gauge | Cable Lead Lg., ft. | Center-to-Center Connector Lg. | Color | A | B | A | B | A | B | Features | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | ||||||||||||||||
24V AC/24V DC | ||||||||||||||||
3 | 4A | 18 | 16.5 | 4.3" | Black | 1.06" | 1.06" | 1.18" | 1.18" | 1.06" | 1.71" | Power-Indicating Light | 185° | IP67 | 00000000 | 000000 |
3 | 4A | 18 | 16.5 | 5.9" | Black | 1.06" | 1.06" | 1.18" | 1.18" | 1.06" | 1.71" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |


Number of Poles | Current | For Wire Gauge | Wire Lead Gauge | Cable Orientation | Cable Lead Lg., ft. | Terminal Connection Type | Color | Lg. | Wd. | Ht. | Features | Max. Temp., °F | Environmental Rating | Each | |
Type B—0.39" (10 mm) Contact Distance | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24V AC/24V DC | |||||||||||||||
3 | 4A | 18 | 18 | Opposite Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 000000 |
3 | 4A | 18 | 18 | Opposite Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
110V AC/110V DC | |||||||||||||||
3 | 4A | 18 | 18 | With Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
230V AC/230V DC | |||||||||||||||
3 | 10A | 18 | 18 | With Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | __ | 185° | IP67 | 00000000 | 00000 |
3 | 10A | 18 | 18 | With Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | __ | 185° | IP67 | 00000000 | 00000 |
Type BI—0.43" (11 mm) Contact Distance | |||||||||||||||
24V AC/24V DC | |||||||||||||||
3 | 4A | 18 | 18 | Opposite Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | Opposite Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 10 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 33 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
110V AC/110V DC | |||||||||||||||
3 | 4A | 18 | 18 | Opposite Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67, IP66K | 00000000 | 00000 |
3 | 4A | 18 | 18 | Opposite Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67, IP66K | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 10 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 33 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |


Number of Poles | Current | For Wire Gauge | Wire Lead Gauge | Cable Lead Lg., ft. | Terminal Connection Type | Color | Lg. | Wd. | Ht. | Features | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24V AC/24V DC | ||||||||||||||
3 | 4A | 18 | 18 | 10 | Solder | Gray | 1.77" | 1.06" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 000000 |
3 | 4A | 18 | 18 | 33 | Solder | Gray | 1.77" | 1.06" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |



Number of Poles | Voltage | Current | Terminal Connection Type | Mounting Fasteners Included | Pipe Size | Lg. | Wd. | Ht. | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
250V AC/250V DC | ||||||||||||
2 | 250V AC/250V DC | 16A | Solder | Yes | 1/2 | 1.32" | 1.34" | 1.32" | 255° | IP65 | 0000000 | 00000 |
3 | 250V AC/250V DC | 16A | Solder | Yes | 1/2 | 1.32" | 1.34" | 1.32" | 255° | IP65 | 0000000 | 0000 |
Type C—0.31" (8 mm) Contact Distance | ||||||||||||
250V AC/250V DC | ||||||||||||
2 | 250V AC/250V DC | 6A | Solder | Yes | __ | 0.67" | 0.34" | 0.67" | 190° | IP65 | 0000000 | 0000 |
3 | 250V AC/250V DC | 6A | Solder | Yes | __ | 0.67" | 0.34" | 0.67" | 190° | IP65 | 0000000 | 0000 |
Type CI—0.37" (9.4 mm) Contact Distance | ||||||||||||
250V AC/250V DC | ||||||||||||
2 | 250V AC/250V DC | 4A | Solder | Yes | __ | 0.64" | 0.34" | 0.64" | 190° | IP65 | 0000000 | 0000 |
3 | 250V AC/250V DC | 4A | Solder | Yes | __ | 0.64" | 0.34" | 0.64" | 190° | IP65 | 0000000 | 0000 |
Compact Build-Your-Own Latching Connectors

Build a connector that fits in tight spaces by combining male and female inserts and then pairing them with any base and hood of the same material. Use them to protect connections while maintaining access. The base and hood latch together securely, yet can be quickly detached for equipment repair or replacement. Once assembled, they’re rated NEMA 4X for protection against washdowns and NEMA 12 to resist oil/coolant dripping.
Latching connectors that are rated IP67 can be submerged in up to 1 meter of water for 30 minutes.
For technical drawings and 3-D models, click on a part number.


Number of Poles | Number of Ground Connections | Voltage | Current | For Wire Gauge | Insert Material | Specifications Met | Each | |
Female Insert | ||||||||
---|---|---|---|---|---|---|---|---|
3 | 1 | 600V AC/600V DC | 10A | 18-14 | Polycarbonate Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 000000 |
4 | 1 | 600V AC/600V DC | 10A | 18-14 | Polycarbonate Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 00000 |
6 | __ | 50V AC/50V DC | 10A | 18-16 | Polyamide Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 00000 |
Male Insert | ||||||||
3 | 1 | 600V AC/600V DC | 10A | 18-14 | Polycarbonate Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 0000 |
4 | 1 | 600V AC/600V DC | 10A | 18-14 | Polycarbonate Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 00000 |
6 | __ | 50V AC/50V DC | 10A | 18-16 | Polyamide Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 00000 |


Conduit | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Number of Poles | Housing Material | Trade Size | Thread Type | Connection Gender | Lg. | Wd. | Ht. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Side Conduit Connection | ||||||||||||
3, 4, 6 | Powder-Coated Zinc | 1/2 | NPT | Female | 1.5" | 1.4" | 2.1" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
3, 4, 6 | Polycarbonate Plastic | 1/2 | NPT | Female | 1.5" | 1.4" | 2.1" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Top Conduit Connection | ||||||||||||
3, 4, 6 | Powder-Coated Zinc | 1/2 | NPT | Female | 1" | 1.4" | 2.4" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3, 4, 6 | Polycarbonate Plastic | 1/2 | NPT | Female | 1" | 1.4" | 2.4" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |



Conduit | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Number of Poles | Housing Material | Number of Latching Levers | Trade Size | Thread Type | Lg. | Wd. | Ht. | Fasteners Included | Number of Holes | Hole Dia. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Female Conduit Connection | |||||||||||||||
3, 4, 6 | Powder-Coated Zinc | 1 | 1/2 | NPT | 0.9" | 1.4" | 2.2" | __ | __ | __ | -40° to 255° | NEMA 4X, NEMA 12, IP67 | UL Recognized Component, UL 94 V-0 | 0000000 | 000000 |
3, 4, 6 | Polycarbonate Plastic | 1 | 1/2 | NPT | 0.9" | 1.4" | 2.2" | __ | __ | __ | -40° to 255° | NEMA 4X, NEMA 12, IP44 | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Bottom Mounting Flange | |||||||||||||||
3, 4, 6 | Powder-Coated Zinc | 1 | __ | __ | 1.4" | 1.6" | 0.9" | No | 2 | 0.13" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | UL Recognized Component, UL 94 V-0 | 0000000 | 0000 |
3, 4, 6 | Polycarbonate Plastic | 1 | __ | __ | 1.4" | 1.6" | 0.9" | No | 2 | 0.13" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | UL Recognized Component, UL 94 V-0, C-UL Recognized Component, CE Marked, DNV-GL Type Approved | 0000000 | 0000 |
Side Mounting Flange | |||||||||||||||
3, 4, 6 | Powder-Coated Zinc | 1 | __ | __ | 1.8" | 1.6" | 1" | No | 2 | 0.13" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
3, 4, 6 | Polycarbonate Plastic | 1 | __ | __ | 1.8" | 1.6" | 1" | No | 2 | 0.13" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | UL Recognized Component, UL 94 V-0, C-UL Recognized Component, CE Marked, DNV-GL Type Approved | 0000000 | 00000 |
Compact Latching Connectors
The smallest latching connectors we offer, these fit in tight spaces. Use them to protect connections while maintaining access. The base and hood latch together securely yet can be quickly detached for equipment repair or replacement.
Latching connectors with cord grips protect cable from strain and remain secure even if cable is accidentally tugged. Connectors with two cord grips are typically used to create a disconnection point on equipment that cannot have a panel cutout, such as curved or compact equipment.
Screw terminal wire connections do not require special tools to create connections. Crimp on wire connections are more secure than screw terminal wire connections and hold up to bending and twisting. Use a crimping tool to install the crimping pins. For 12-pole connectors, you also need a positioner to hold pins at the correct height while crimping. Crimping tool and positioner are both sold separately.
NEMA 4X rated connectors protect against washdowns. NEMA 12 rated connectors resist oil/coolant dripping. IP65 rated connectors protect against dust and rinsing. IP67 rated connectors can be temporarily submerged.
For technical drawings and 3-D models, click on a part number.

with Bottom
Mounting Flange
Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Ground Connections | Voltage | Current | Trade Size | Thread Type | Connection Gender | For Wire Gauge | Lg. | Wd. | Ht. | Temp. Range, °F | Environmental Rating | Each | |
Screw Terminal Wire Connection | ||||||||||||||
Powder-Coated Zinc | ||||||||||||||
3 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.6" | 3.7" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | 0000000 | 000000 |
4 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.6" | 3.7" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | 0000000 | 00000 |
Polycarbonate Plastic | ||||||||||||||
3 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.6" | 3.7" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | 0000000 | 00000 |
4 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.6" | 3.7" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | 0000000 | 00000 |

Connection with
Side Mounting Flange
Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Ground Connections | Voltage | Current | Trade Size | Thread Type | Connection Gender | For Wire Gauge | Lg. | Wd. | Ht. | Temp. Range, °F | Environmental Rating | Each | |
Screw Terminal Wire Connection | ||||||||||||||
Powder-Coated Zinc | ||||||||||||||
3 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.6" | 3.8" | 1.6" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | 0000000 | 000000 |
4 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.6" | 3.8" | 1.6" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | 0000000 | 00000 |
Polycarbonate Plastic | ||||||||||||||
3 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.6" | 4.5" | 1" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | 0000000 | 00000 |
4 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.6" | 4.5" | 1" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | 0000000 | 00000 |

Connection with
Bottom Mounting Flange
Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Ground Connections | Voltage | Current | Trade Size | Thread Type | Connection Gender | For Wire Gauge | Lg. | Wd. | Ht. | Temp. Range, °F | Environmental Rating | Each | |
Screw Terminal Wire Connection | ||||||||||||||
Powder-Coated Zinc | ||||||||||||||
3 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.9" | 3.1" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | 0000000 | 000000 |
4 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.9" | 3.1" | -40° to 255° | NEMA 4X, NEMA 12, IP67 | 0000000 | 00000 |
Polycarbonate Plastic | ||||||||||||||
3 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.9" | 3.1" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | 0000000 | 00000 |
4 | 1 | 600V AC/ 600V DC | 10A | 3/8 | NPT | Female | 18-14 | 1.1" | 1.9" | 3.1" | -40° to 255° | NEMA 4X, NEMA 12, IP44 | 0000000 | 00000 |

with Bottom
Mounting Flange
Number of Poles | Number of Ground Connections | Voltage | Current | For Cable OD | For Wire Gauge | Lg. | Wd. | Ht. | Temp. Range, °F | Environmental Rating | Each | |
Screw Terminal Wire Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nylon Plastic | ||||||||||||
3 | 1 | 250V AC/ 250V DC | 10A | 0.23"-0.39" | 18-16 | 1.1" | 1.4" | 3.6" | -20° to 190° | IP65 | 00000000 | 000000 |
Crimp On Wire Connection | ||||||||||||
Nylon Plastic | ||||||||||||
3 | 1 | 600V AC/ 600V DC | 16A | 0.23"-0.39" | 12 | 1.1" | 1.4" | 3.6" | -20° to 190° | IP65 | 00000000 | 00000 |
12 | __ | 30V AC/ 30V DC | 6.5A | 0.23"-0.39" | 24-20 | 1.1" | 1.4" | 3.6" | -20° to 190° | IP65 | 00000000 | 00000 |

Connection with Side
Mounting Flange
Number of Poles | Number of Ground Connections | Voltage | Current | For Cable OD | For Wire Gauge | Lg. | Wd. | Ht. | Temp. Range, °F | Environmental Rating | Each | |
Screw Terminal Wire Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nylon Plastic | ||||||||||||
3 | 1 | 250V AC/ 250V DC | 10A | 0.23"-0.39" | 18-16 | 1.2" | 1.2" | 4.9" | -20° to 190° | IP65 | 00000000 | 000000 |
Crimp On Wire Connection | ||||||||||||
Nylon Plastic | ||||||||||||
3 | 1 | 600V AC/ 600V DC | 16A | 0.23"-0.39" | 12 | 1.2" | 1.2" | 4.9" | -20° to 190° | IP65 | 00000000 | 00000 |
12 | __ | 30V AC/ 30V DC | 6.5A | 0.23"-0.39" | 24-20 | 1.2" | 1.2" | 4.9" | -20° to 190° | IP65 | 00000000 | 00000 |

with Side Mounting
Flange
Number of Poles | Number of Ground Connections | Voltage | Current | For Cable OD | For Wire Gauge | Lg. | Wd. | Ht. | Temp. Range, °F | Environmental Rating | Each | |
Screw Terminal Wire Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nylon Plastic | ||||||||||||
3 | 1 | 250V AC/ 250V DC | 10A | 0.23"-0.39" | 18-16 | 1.4" | 1.1" | 4.4" | -20° to 190° | IP65 | 00000000 | 000000 |
Crimp On Wire Connection | ||||||||||||
Nylon Plastic | ||||||||||||
3 | 1 | 600V AC/ 600V DC | 16A | 0.23"-0.39" | 12 | 1.4" | 1.1" | 4.4" | -20° to 190° | IP65 | 00000000 | 00000 |
12 | __ | 30V AC/ 30V DC | 6.5A | 0.23"-0.39" | 24-20 | 1.4" | 1.1" | 4.4" | -20° to 190° | IP65 | 00000000 | 00000 |
Stackable Pin-to-Pin Connectors

Stack housings and lock them together to form a connector with as many poles as you need. Connectors have a slotted dovetail on each side—align the slots and slide the housings together to lock. An internal stainless steel spring ensures that the pins maintain constant pressure. Current rating is based on a single-pole configuration using the largest wire shown within each range. Also known as power-pole connectors.
Enclosures (sold separately) hold four connectors.
For technical drawings and 3-D models, click on a part number.

Connectors | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mated Housing | Replacement Housings | ||||||||||||||
Current | Voltage | No. of Poles | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Temp. Range, °F | Choose a Color | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | ||
15A | 600V AC/600V DC | 1 | Crimp On | 20-16 | 1.6" | 0.3" | 0.3" | 0° to 220° | 5 | 0000000 | 00000 | 5 | 000000 | 00000 | |
30A | 600V AC/600V DC | 1 | Crimp On | 16-12 | 1.6" | 0.3" | 0.3" | 0° to 220° | 5 | 000000 | 0000 | 5 | 000000 | 0000 | |
45A | 600V AC/600V DC | 1 | Crimp On | 14-10 | 1.6" | 0.3" | 0.3" | 0° to 220° | 5 | 000000 | 0000 | 5 | 000000 | 0000 | |
75A | 600V AC/600V DC | 1 | Crimp On | 6 | 3.2" | 0.6" | 0.6" | 0° to 220° | 1 | 000000 | 0000 | 1 | 000000 | 0000 | |
120A | 600V AC/600V DC | 1 | Crimp On | 2 | 4.6" | 0.9" | 0.9" | 0° to 220° | 1 | 000000 | 00000 | 1 | 000000 | 0000 | |
180A | 600V AC/600V DC | 1 | Crimp On | 1/0 | 5.5" | 1.1" | 1.1" | 0° to 220° | 1 | 000000 | 00000 | 1 | 000000 | 00000 |

For No. of Connectors | Housing Material | Lg. | Wd. | Ht. | Temp. Range, °F | Color | Each | |
4 | Polycarbonate Plastic | 1.9" | 1.2" | 0.9" | 0° to 220° | Black | 0000000 | 00000 |

Current | Voltage | For Wire Gauge | Pin Material | Pkg. Qty. | Pkg. | |
15A | 600V AC/600V DC | 20-16 | Silver-Plated Copper | 5 | 0000000 | 00000 |
30A | 600V AC/600V DC | 16-12 | Silver-Plated Copper | 5 | 0000000 | 0000 |
45A | 600V AC/600V DC | 14-10 | Tin-Plated Copper | 5 | 0000000 | 0000 |
75A | 600V AC/600V DC | 6 | Silver-Plated Copper | 1 | 0000000 | 0000 |
120A | 600V AC/600V DC | 2 | Silver-Plated Copper | 1 | 0000000 | 0000 |
180A | 600V AC/600V DC | 1/0 | Silver-Plated Copper | 1 | 0000000 | 00000 |
Solenoid Valve Cords
Use these cords with hydraulic and air-powered valves, motors, pumps, and pressure switches. They have a solenoid valve socket on one end and an M12 threaded plug on the other. The ground connection is not included in the number of poles. A power-indicating light on the socket illuminates when the cord has power. All are IP-rated for protection from washdowns and temporary submersion.
For technical drawings and 3-D models, click on a part number.

Socket | Plug | Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DIN Type | Contact Distance | Housing Thread Size | Coding | No. of Poles | No. of Ground Connections | Lg., ft. | Wire Gauge | Current, A | Voltage | OD | Insulation Material | Environmental Rating | Specifications Met | Each | |
90° Elbow Socket × Plug (External Thread) | |||||||||||||||
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 000000 |
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |

For Thread Size | Material | Includes | Each | |
For Plugs | ||||
---|---|---|---|---|
M12 | Anodized Aluminum | Lanyard | 0000000 | 000000 |