About Sump, Water-Removal, Condensate, and Submersible Pumps
More
How to Prime Your Pump
More
How to Determine Feet of Head
More
About Vacuum Pumps
More
About Process Pumps
More
About Drum Pumps
More
Adjustable-Flow Inline Circulation Pumps for Water
Accommodate performance changes in your system with a three-speed switch that adjusts flow rate. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Mount horizontally with the included pipe connectors. Do not run dry or use with solids. Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps with 304 stainless steel housing are lead free.
Flow Rate, gpm (Speed No.) | Pipe Size (Female, NPT) | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. | @ 10 ft. of Head | @ 20 ft. of Head | Current, A (Speed No.) | Flow Adjustment Rate | Max. ft. of Head | Max. Viscosity, cP | hp | Intake | Discharge | Lg. | Wd. | Ht. | Each | |
240V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||
Cast Iron Housing—Hardwire | ||||||||||||||
19 (1), 28 (2), 30 (3) | 7 (1), 19 (2), 23 (3) | 2 (1), 10 (2), 13 (3) | 0.8 (1), 0.85 (2), 0.9 (3) | ± 6% | 31 | 1 | 1/4 | 1 | 1 | 6 3/8" | 5 1/2" | 6 1/2" | 00000000 | 0000000 |
19 (1), 28 (2), 30 (3) | 7 (1), 19 (2), 23 (3) | 2 (1), 10 (2), 13 (3) | 0.8 (1), 0.85 (2), 0.9 (3) | ± 6% | 31 | 1 | 1/4 | 1 1/4 | 1 1/4 | 6 3/8" | 5 1/2" | 6 1/2" | 00000000 | 000000 |
19 (1), 28 (2), 30 (3) | 7 (1), 19 (2), 23 (3) | 2 (1), 10 (2), 13 (3) | 0.8 (1), 0.85 (2), 0.9 (3) | ± 6% | 31 | 1 | 1/4 | 1 1/2 | 1 1/2 | 6 3/8" | 5 1/2" | 6 1/2" | 00000000 | 000000 |
304 Stainless Steel Housing—Hardwire | ||||||||||||||
19 (1), 28 (2), 30 (3) | 7 (1), 19 (2), 23 (3) | 2 (1), 10 (2), 13 (3) | 0.8 (1), 0.85 (2), 0.9 (3) | ± 6% | 31 | 1 | 1/4 | 1 | 1 | 6 3/8" | 5 1/2" | 6 1/2" | 00000000 | 000000 |
19 (1), 28 (2), 30 (3) | 7 (1), 19 (2), 23 (3) | 2 (1), 10 (2), 13 (3) | 0.8 (1), 0.85 (2), 0.9 (3) | ± 6% | 31 | 1 | 1/4 | 1 1/4 | 1 1/4 | 6 3/8" | 5 1/2" | 6 1/2" | 00000000 | 000000 |
19 (1), 28 (2), 30 (3) | 7 (1), 19 (2), 23 (3) | 2 (1), 10 (2), 13 (3) | 0.8 (1), 0.85 (2), 0.9 (3) | ± 6% | 31 | 1 | 1/4 | 1 1/2 | 1 1/2 | 6 3/8" | 5 1/2" | 6 1/2" | 00000000 | 000000 |
Immersion Circulation Pumps for Coolants
Commonly used in machine tool coolant tanks, these pumps have an intake that can be completely submerged in liquid. A universal mounting plate fits machine tools from manufacturers such as Fuji, Mitsubishi, Toshiba, Hitachi, and Yasukawa. Motor is totally enclosed with sealed bearings for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. They can run dry.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge (NPT) | Overall | Replacement Impellers | ||||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake Connection Type | Pipe Size | Gender | Lg. | Wd. | Ht. | Shaft Ht. | Each | Each | ||
120/240V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
20 | 20 | 14 | 5 | 33 | 13 | 90 | 1/4 | 3/1.5 | Open Inlet | 1/2 | Female | 7 1/2" | 5" | 14 7/8" | 7 1/16" | 00000000 | 0000000 | 0000000 | 000000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
20 | 20 | 14 | 5 | 33 | 13 | 90 | 1/4 | 0.9/0.6 | Open Inlet | 1/2 | Female | 7 1/2" | 5" | 14 7/8" | 7 1/16" | 00000000 | 000000 | 0000000 | 00000 |
Remote-Mount Circulation Pumps for Water and Coolants
Use when space is limited—these pumps connect to a pipe coming from your tank so you can place the pump in another location. Mount above or below the liquid level. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Replacement Impellers | ||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
20 | 20 | 14 | 33 | 13 | 90 | 1/4 | 3/1.5 | 3/4 | Female | 3/4 | Female | 8" | 7 1/16" | 9 5/32" | 00000000 | 0000000 | 000000 | 00 |
240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
20 | 20 | 14 | 33 | 13 | 90 | 1/4 | 0.9/0.6 | 3/4 | Female | 3/4 | Female | 8" | 7 1/16" | 9 5/32" | 00000000 | 000000 | 0000000 | 000000 |
Maintenance Kit for Pumps with 10 gpm or 20 gpm Max. Flow Rate | 00000000 | Each | 000000 |
Extended-Life Plastic Circulation Pumps for Chemicals
These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Maintenance Kits | Replacement Impellers | ||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | Max. ft. of Head | hp | Current, A | Intake (Gender) | Discharge (Gender) | Lg. | Wd. | Ht. | Each | Each | Each | |||
120V AC, 240V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
23 | 20 | 10 | 35 | 1/4 | 2.07/4.14 | 1 (Female) | 1 (Female) | 14 3/8" | 5 1/8" | 7 7/8" | 0000000 | 000000000 | 00000000 | 000000 | 00000000 | 0000000 |
High-Pressure Constant-Flow-Rate Pumps
Commonly called rotary vane pumps, these are designed to pump water at high pressures in low-flow applications. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. They have a built-in bypass relief valve to prevent pressure buildup. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | hp | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.8 | 240 | Not Rated | 30° to 195° | 1/4 | 5 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 0000000 |
Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Repair Parts | |||||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Electrical Connection Type | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | 0-18.5 | 9 | 30 | 15° | 120° | 1/4 hp | 1.5 | 32 mm | Wall Bracket | 1 1/4" | 27" | 3/4" | 1" | 60" | Plug | 00000000 | 0000000 | 00000000 |
A | 0-18.5 | 9 | 55 | 15° | 120° | 1/4 hp | 1.5 | 32 mm | Wall Bracket | 1 1/4" | 39" | 3/4" | 1" | 60" | Plug | 00000000 | 000000 | 00000000 |
Battery-Operated Drum Pumps with Nozzle for Fuel
Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with metering nozzle record total volume up to 99,999.9 gallons.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | ID | Lg., ft. | Nozzle Type | Each | |
12V DC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Manual Shut-Off, Lockable | 0000000 | 0000000 |
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Metering, Manual Shut-Off | 0000000 | 000000 |
Float-Switch Activated Sump Pumps for Water
Remove accumulated water from sump pits, loading docks, and cooling towers. The float switch is wired to the pump. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||
35 | 30 | 10 | 25 | 10" | 5" | 35° to 120° | 1/4 hp | 3.5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 10" | 9" | 0000000 | 0000000 |
Harsh-Environment Self-Priming Water-Removal Pumps
This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Intake Size | Discharge Size | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||
Plug with 8 ft. Cord | |||||||||||||
5 4/5 | 30 | 1/4" | 125 | 60° to 180° | 1/4 hp | 4.2 | 1/2 NPT Female, 3/4 GHT Male | 1/2 NPT Female, 3/4 GHT Male | 9" | 5 5/8" | 7 3/8" | 0000000 | 0000000 |
Plastic Water-Removal Pumps
Clean up water in flooded areas without a sump pit. Install these pumps in debris-free water that’s at least 2" deep. They activate when plugged in. You can add a plug-in switch to control when the pump activates. Submerge while in use.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Includes | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 6 | 1 1/4 | NPT | Female | 10" | 8" | 8" | Garden Hose Adapter | 0000000 | 0000000 |
Impact-Resistant Metal Water-Removal Pumps
An aluminum housing provides excellent impact resistance. Use these pumps to clean up water in flooded areas without a sump pit. Install them in debris-free water that’s at least 2” deep. Pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Submerge while in use.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Includes | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 5.6 | 1 1/4 | NPT | Female | 9" | 7" | 7" | Garden Hose Adapter | 0000000 | 0000000 |
Plug with 25 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 5.6 | 1 1/4 | NPT | Female | 9" | 7" | 7" | Garden Hose Adapter | 0000000 | 000000 |
High-Flow Metering Pumps for Chemicals
For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | For Tube ID | Tube Connection Type | For Tube ID | Tube Connection Type | Lg. | Wd. | Ht. | Includes | Each | |
120V AC, Single Phase | |||||||||||||||
Plug | |||||||||||||||
2,592 | 20 | 1,000 | 35° to 160° | 1/4 hp | 3.1 | 1/2" | Barbed | 1/2" | Barbed | 10" | 5 1/2" | 10" | 10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61) | 0000000 | 0000000 |
Oil-Free Electric Vacuum Pumps
Since these pumps don't require lubrication, there’s no risk of oil contamination. Maximum flow rate is the rate at which air is pumped before a vacuum is created. Flow rate steadily decreases as the pump generates the vacuum. The larger the tank, the longer it will take to form a vacuum.
Style B pumps are often used for aeration, leak detection, and liquid-level control.
Intake | Discharge | O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Max. Vacuum, in. of Hg | Max. Flow Rate, cfm | Max. Pressure, psi | Temp. Range, °F | Volume, dBA | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
NEMA 5-15 Plug | ||||||||||||||||||
B | 26 | 4.5 | 10 | 30° to 100° | 70 | 1/4 hp | 2.1/4.3 | 1/4 | NPT | Female | 1/4 | NPT | Female | 14" | 5 5/8" | 6" | 0000000 | 0000000 |
Condensate Pumps with Tank
Equipped with a built-in container for condensate, these pumps work alongside your system to remove condensate from air conditioners, refrigerators, dehumidifiers, and other equipment. They are not submersible. A safety switch turns off your equipment in case of pump failure. Pumps turn on and off automatically.
Hardwire pumps must be wired to a power source.
Style D pumps withstand higher temperatures than the other styles.
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, gal. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube OD | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
D | Hardwire | 1 | 7.9 | 7.3 | 6.6 | 50 | 22 | 3 3/16" | 7/8" | 35° to 210° | 1/4 hp | 4 | Compression | 1/2" | 10 1/8" | 6" | 12" | 0000000 | 0000000 |
Steam Condensate Pumps with Tank
Designed for use in low-pressure steam systems, these pumps capture steam in the attached tank and return hot condensate to your boiler or feed unit. They are activated by a float switch, turning on and off when condensate level reaches a certain depth.
Pumps with cast iron tank are for continuous use and have a longer service life than carbon steel.
Maintenance kit for pump with cast iron tank includes a shaft, a bushing, a thrust washer, a spring washer, an oil seal, and snap rings.
Max. Flow Rate, gpm | Level | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | Tank Cap., gal. | @ 35 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | 8 | 6.5 | 5.8 | 69 | 30 | 7 1/4" | 5 1/4" | 160° to 200° | 1/4 hp | 2.5/5 | 2 NPT Female | 1 NPT Female | 26" | 17" | 17" | 0000000 | 000000000 |
Maintenance Kit | 0000000 | Each | 0000000 |