Choosing an Electrical Switch
More
About Safety Ratings for Electrical Testing
More
Wireless Pendant Switches
Operate equipment from up to 330 feet away—these switches include a transmitter and a receiver that connects to equipment. Use up to 45 wireless switches in the same area. They're rated IP65 for protection from washdowns.
Two-speed switches have staged contacts. For slow speed, press the button halfway down to close the first contact. For high speed, push it all the way to close the second contact.
Switches and replacement transmitters that cannot be sold to Canada are restricted by product labeling requirements.
Replace worn stickers or change the function of a button with labels. Packs include commonly used functions such as up, down, start, and stop.
To Order: For existing systems, please advise which channels are currently in use so that a different channel can be provided. For the replacement transmitter, please specify the serial number.
No. of Buttons | No. of Circuits Controlled per Actuator | Switch Starting Position | Switch Action | No. of Terminals per Actuator | Switching Current @ Voltage | Max. Voltage | Actuator Color (Industry Designation) | Housing Material | Cannot Be Sold To | For Existing Systems | For New Systems | |
1 Speed with Wire Leads with Spade Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 8 A @ 30 V DC | 24V DC | 1 Black Buttons with Up (SPST-NO), 3 White Buttons with Down; Stop; Start/Go (SPST-NO) | Blue Plastic | __ | 00000000 | ||
4 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 125 V AC, 5 A @ 250 V AC | 110V AC | 1 Black Buttons with Up (SPST-NO), 3 White Buttons with Down; Stop; Start/Go (SPST-NO) | Blue Plastic | Canada | 00000000 | ||
6 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 8 A @ 30 V DC | 24V DC | 2 Black Buttons with Up/East (SPST-NO), 4 White Buttons with Down; West; Stop; Start/Go (SPST-NO) | Blue Plastic | __ | 00000000 | ||
6 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 125 V AC, 5 A @ 250 V AC | 110V AC | 2 Black Buttons with Up/East (SPST-NO), 4 White Buttons with Down; West; Stop; Start/Go (SPST-NO) | Blue Plastic | Canada | 00000000 | ||
13 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 5 A @ 250 V AC/24 V DC | 110V AC | 5 Black Buttons with Up/East/South/1/3 and Turn Reset; (SPST-NO), 6 White Buttons with Down; West; North; 2; 4; Aux 2 (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC), 1 Green Buttons with Aux 1, Start (SPST-NO) | Yellow Plastic | Canada | 00000000 | ||
1 Speed with Wire Leads with Spade Terminals—With Green Off/On Lever Switch | ||||||||||||
9 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 5 A @ 250 V AC/24 V DC | 110V AC | 3 Black Buttons with Up/East/South and Turn Reset; (SPST-NO), 4 White Buttons with Down; West; North; Aux 2 (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC), 1 Green Buttons with Start (SPST-NO) | Yellow Plastic | Canada | 00000000 | ||
9 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 5 A @ 24 V DC | 24V DC | 3 Black Buttons with Up/East/South and Turn Reset; (SPST-NO), 4 White Buttons with Down; West; North; Aux 2 (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC), 1 Green Buttons with Start (SPST-NO) | Yellow Plastic | __ | 00000000 | ||
1 Speed with Wire Leads with Spade Terminals—With Green Off/On/Start Lever Switch | ||||||||||||
7 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 5 A @ 250 V AC/24 V DC | 24V DC | 3 Black Buttons with Up/East/South and Turn Reset; (SPST-NO), 3 White Buttons with Down; West; North (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC) | Blue Plastic | Canada | 0000000 | ||
7 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 5 A @ 250 V AC/24 V DC | 110V AC | 3 Black Buttons with Up/East/South and Turn Reset; (SPST-NO), 3 White Buttons with Down; West; North (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC) | Blue Plastic | Canada | 0000000 | ||
2 Speed with Wire Leads with Spade Terminals—With Green Off/On/Start Lever Switch | ||||||||||||
5 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 125 V AC, 5 A @ 250 V AC | 24V AC | 2 Black Buttons with Up/East and Turn Reset; (SPST-NO), 2 White Buttons with Down; West (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC) | Blue Plastic | Canada | 00000000 | ||
5 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 125 V AC, 5 A @ 250 V AC | 110V AC | 2 Black Buttons with Up/East and Turn Reset; (SPST-NO), 2 White Buttons with Down; West (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC) | Blue Plastic | Canada | 00000000 | ||
9 | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | 10 A @ 125 V AC, 5 A @ 250 V AC, 8 A @ 30 V AC | 110V AC | 4 Black Buttons with Up/East/South/1 and Turn Reset; (SPST-NO), 4 White Buttons with Down; West; North; 2 (SPST-NO), 1 Red Buttons with Right Arrows (SPST-NC) | Orange Plastic | Canada | 00000000 |
Wireless Foot Switches
Activate equipment from up to 40 feet away—these switches include a transmitter and a receiver that connects to equipment. The transmitter is rated IP68 and the receiver is rated IP01.
Wire Leads | Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Switching Current @ Voltage | Max. Voltage | Transmission Frequency, GHz | Color | No. of | Lg., ft. | Fasteners Included | No. of Holes | Hole Dia. | Each | |
1 Speed with Wire Leads | ||||||||||||||
Iron Housing with Aluminum Guard | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | 10 A @ 125 V AC/250 V AC, 8 A @ 24 V DC | 48V DC 380V AC | 2.41-2.48 | Orange | 3 | 10 | No | 3 | 0.31" | 000000 | 000000000 |
Wireless Light Switches
Control lights by transmitting a wireless signal from these switches to a control relay (sold separately) on your fixture. Switches can be surface mounted with a wall plate or used as a hand-held remote. No batteries or secondary power source are needed.
No. of Circuits Controlled | Color | Max. Transmission Distance, ft. | Transmission Frequency | Includes | Each | |
1 | White | 150 | 902 MHz | One Switch, One Wall Plate | 0000000 | 0000000 |
No. of Circuits Controlled | Switch Starting Position | Industry Designation | Input Voltage | Switching Current @ Voltage | Wire Lead Lg. | Each | |
1 | 1 Off (Normally Open) | SPST-NO | 120V AC | 5 A @ 120 V AC/277 V AC | 16" | 0000000 | 0000000 |
1 | 1 Off (Normally Open) | SPST-NO | 208V AC/277V AC | 5 A @ 120 V AC/277 V AC | 16" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 120V AC | 10 A @ 120 V AC, 20 A @ 277 V AC | 16" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 277V AC | 10 A @ 120 V AC, 20 A @ 277 V AC | 16" | 0000000 | 000000 |
Wireless Relays
Send a signal with these relays to turn equipment on and off from up to 150 feet away without having to run electrical wire. They can be set to transmit, receive, or both at once. You’ll need at least two relays to switch a device. They have an alarm that can be set to check for certain conditions before transmitting a signal. For example, you could set these relays to send a signal to turn on an air conditioner if all windows are closed. The repeat function extends the transmitting signal through a maximum of two receiving relays.
Relays that are set to transmit can be linked up to as many receiving relays as you need. Relays set to receive can be linked up to 30 transmitting relays. All relays connect to dry contacts on your switch, sensor, or controller. Use the wire leads to connect them to a power source.
UL and C-UL listed, all meet American and Canadian safety standards. Rated NEMA 1, they should only be used indoors.
For technical drawings and 3-D models, click on a part number.
Wire Lead | Conduit Connection | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | Control Current | Switching Current @ 277V AC | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Maximum Transmission Distance, ft. | Lg. | Number of | Gender | Trade Size | Thread Type | Environmental Rating | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
120V AC | 73 | 20A | 277V AC | 2 hp @ 277 V AC | 2.3" | 3.2" | 1.8" | 150 | 16" | 7 | Male | 1/2 | NPT | NEMA 1 | 0000000 | 0000000 |
208V AC | 80 | 20A | 277V AC | 2 hp @ 277 V AC | 2.3" | 3.2" | 1.8" | 150 | 16" | 7 | Male | 1/2 | NPT | NEMA 1 | 0000000 | 000000 |
240V AC | 80 | 20A | 277V AC | 2 hp @ 277 V AC | 2.3" | 3.2" | 1.8" | 150 | 16" | 7 | Male | 1/2 | NPT | NEMA 1 | 0000000 | 000000 |
277V AC | 80 | 20A | 277V AC | 2 hp @ 277 V AC | 2.3" | 3.2" | 1.8" | 150 | 16" | 7 | Male | 1/2 | NPT | NEMA 1 | 0000000 | 000000 |
24V AC, 24V DC | 69 | 20A | 277V AC | 2 hp @ 277 V AC | 2.3" | 3.2" | 1.8" | 150 | 16" | 7 | Male | 1/2 | NPT | NEMA 1 | 0000000 | 000000 |
Wireless Keyboards
No need to wrangle cords—you can move these keyboards freely around your work space.
Ergonomic keyboards position your hands for improved comfort.
Keyboards with an integrated trackpad do not need a separate mouse.
Liquid-resistant keyboards stand up to coffee, water, soda, and other spills.
Color | Connection Type | Wd. | Dp. | Features | Includes | Each | |
Keyboard | |||||||
---|---|---|---|---|---|---|---|
Black | 4-pin USB Type A (Male) | 14" | 5 1/2" | Low-Profile Keys, Integrated Trackpad | USB Receiver | 00000000 | 000000 |
Keyboard and Mouse | |||||||
Black | 4-pin USB Type A (Male) | 17 1/4" | 5" | Liquid-Resistant Coating, Low-Profile Keys | USB Receiver | 00000000 | 00000 |
Black | 4-pin USB Type A (Male) | 17 3/4" | 10" | Liquid-Resistant Coating, Padded Wrist Rest | USB Receiver | 00000000 | 00000 |
Keyboard | |||||||
---|---|---|---|---|---|---|---|
Color | Connection Type | Wd. | Dp. | Features | Includes | Each | |
Black | 4-pin USB Type A (Male) | 17" | 6" | Low-Profile Keys | USB Receiver | 00000000 | 000000 |
Color | Connection Type | Wd. | Dp. | Features | Includes | Each | |
Keyboard | |||||||
---|---|---|---|---|---|---|---|
Black | 4-pin USB Type A (Male), Bluetooth | 18" | 7 3/4" | Liquid-Resistant Coating, Low-Profile Keys, Padded Wrist Rest | USB Receiver | 00000000 | 000000 |
Gray | 4-pin USB Type A (Male), Bluetooth | 18" | 7 3/4" | Liquid-Resistant Coating, Low-Profile Keys, Padded Wrist Rest | USB Receiver | 00000000 | 00000 |
Keyboard and Mouse | |||||||
Black | 4-pin USB Type A (Male), Bluetooth | 18" | 7 3/4" | Liquid-Resistant Coating, Low-Profile Keys, Padded Wrist Rest | USB Receiver | 00000000 | 000000 |
Gray | 4-pin USB Type A (Male), Bluetooth | 18" | 7 3/4" | Liquid-Resistant Coating, Low-Profile Keys, Padded Wrist Rest | USB Receiver | 00000000 | 000000 |
Wireless Mice
Ergonomic mice are also known as vertical mice—a 60° tilt angle keeps your wrist in a handshake position to improve wrist and forearm alignment.
Mice with a laser sensor are more precise than mice with an optical sensor and work on reflective surfaces.
Wireless Mouse Type | Connection Type | Ht. | Wd. | Dp. | Color | Batteries Included | Includes | Each | |
Optical | |||||||||
---|---|---|---|---|---|---|---|---|---|
Standard | 4-pin USB Type A (Male) | 1 5/8" | 2 5/8" | 4 1/4" | Black | Yes | USB Receiver | 00000000 | 000000 |
Optical with Trackball | |||||||||
Ergonomic | 4-pin USB Type A (Male), Bluetooth | 3 1/4" | 6 1/4" | 4" | Black | Yes | USB Receiver | 00000000 | 00000 |
Laser | |||||||||
Standard | Bluetooth | 3 3/8" | 4 3/8" | 1 3/4" | Black | Yes | __ | 00000000 | 00000 |
Fluke Wireless Remote-Reading Multimeters
A wireless connection transmits electrical measurements from the multimeter to a separate display, so you can take measurements in hard-to-reach or potentially dangerous locations. Fluke multimeters are known for quality and durability.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Fluke 233 has a detachable display that communicates with the multimeter using built-in low-power wireless technology. The Fluke 233 with calibration certificate includes a document stating that it has passed a test for accuracy.
Fluke 3000 FC uses built-in Bluetooth connectivity to transmit measurements to a computer with a Fluke pc3000 FC connector plugged in (not included) or to a mobile device that has the Fluke Connect app. The multimeter also receives measurements from Fluke Wireless Remote-Reading Clamp-On Current Meters and Fluke Wireless Remote-Reading Voltage Meters (not included).
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current | Max. DC Current | Hardware Features | Display Count | Includes | Each | |
Multimeters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | ||||||||||||
233 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.25% | 10 A | 10 A | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 000000 | 0000000 |
3000 FC | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.09% | 400 mA | 400 mA | Lead Storage, Overload Protection | 6,000 | Alligator Clips, Test Leads | 000000 | 000000 |
Multimeters with Calibration Certificate | ||||||||||||
True RMS AC Calculation | ||||||||||||
233 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.25% | 10 A | 10 A | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Connectors and Wireless Remote-Reading Meters for 3000 FC Multimeter | |||
---|---|---|---|
a3001 FC Clamp-On AC Current Meter (10" Jaw Opening) | 00000000 | Each | 0000000 |
a3000 FC Clamp-On AC Current Meter (1.33" Jaw Opening) | 00000000 | Each | 000000 |
pc3000 FC Computer Connector | 00000000 | Each | 000000 |
v3001 FC DC DC Voltage Meter | 00000000 | Each | 000000 |
v3000 FC AC AC Voltage Meter | 00000000 | Each | 000000 |
Fluke Wireless Remote-Reading Voltage Meters
Measure voltage from a distance with these wireless connection-enabled meters that transmit readings to a separate display. Fluke is known for quality and durability.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
The true RMS meter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 1,000-count meters show numbers up to 999.
Manufacturer Model Number | AC Calculation | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | Data Log Capacity | Display Count | Includes | Specifications Met | Batteries Included | Each | |
v3000 FC | True RMS | CAT IV, 600V | AC Voltage | 1,000 | __ | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | 00000000 | 0000000 |
v3001 FC | __ | CAT IV, 600V | DC Voltage | __ | 1,000 | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | 00000000 | 000000 |
Fluke Wireless Remote-Reading Clamp-On Current Meters
Take current measurements from a distance with these high-quality, durable Fluke meters. They wirelessly transmit readings to a separate display. Because the jaws surround a cable, these meters are convenient for taking frequent measurements since you don't have to interrupt the circuit.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. For example, a 1,000-count meter shows numbers up to 999. A higher display count means the meter can give a more precise measurement.
Manufacturer Model Number | Test End | Jaw Opening | Safety Rating | Measures | Max. AC Current, A | Data Log Capacity | Display Count | Includes | Specifications Met | Batteries Included | Each | |
True RMS AC Calculation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
a3000 FC | Current Clamp | 1.33" | CAT III, 600V | AC Current | 400 | 65,000 | 1,000 | __ | CSA Certified, CSA-US Certified | Yes | 00000000 | 0000000 |
a3001 FC | Current Loop | 10" | CAT IV, 600V | AC Current | 2,500 | 65,000 | 2,500 | Magnetic Hanger | CSA Certified, CSA-US Certified | Yes | 00000000 | 000000 |
Magnetic-Contact Door Chimes
No electricity or batteries are needed—as your door opens, the magnet and contact disc are separated, sounding a mechanical chime. The chime can be deactivated.
O'all | Volume | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Material | Color | Control | @ Distance | For Use Outdoors | Mount Type | Mount. Fasteners Included | Each | |
5 3/4" | 2" | 2 3/4" | Plastic | Brown | Fixed | 88 dB @ 10 ft. | No | Surface | Yes | 0000000 | 000000 |
USB Extenders
Increase the reach of USB devices. Connect the transmitter and receiver with an Ethernet cord (sold separately), minimizing signal loss over long runs. USB ports are backward compatible, so they work with cords and connectors that meet the same or a lower USB standard.
Receiver | Transmitter | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
USB Connection Type (No. of Connections) | Ethernet Connection Type | Max. Transmission Distance, ft. | USB Connection Type | Ethernet Connection Type | USB Standard | Transmission Speed, Mbps | Cord Lg. | Color | Housing Material | Includes | Each | |
Type A Female (1) | RJ45 Female | 150 | Type A Male | RJ45 Female | 1.1 | 12 | 12" | Black | Plastic | __ | 000000 | 000000 |
Type A Female (1) | RJ45 Female | 160 | Type A Male | RJ45 Female | 2.0 | 480 | 6" | Black | Plastic | 120V AC Adapter | 000000 | 000000 |
Type A Female (4) | RJ45 Female | 160 | Type A Male | RJ45 Female | 2.0 | 480 | 6" | Black | Plastic | 120V AC Adapter | 000000 | 000000 |
Electronic Lever-Style Variance Indicators
Also known as test indicators, these have a lever-style contact point that pivots as it comes into contact with a surface. Rotate the dial face for viewing at multiple angles. They have selectable measurement increments and can be displayed as digits or in a bar graph. Transmit measurement data to any Bluetooth-enabled device without being tethered by a cable. These indicators are rated IP65 for protection against dust and spraying water or coolant.
Measuring Range | Display Reading | Measuring Increments | Accuracy | Contact Point | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inch | Metric, mm | Inch | Metric | Inch | Metric, mm | Inch | Metric, mm | No. of Dovetail Mounts | Dial Dia. | Head Dia. | Lg. | Mounting Thread Size | Swivel Angle | Batteries Included | SPC Data Output | Environmental Rating | Each | |
0-0.03" | 0-0.8 | 0-40-0 | 0-1-0 | 0.00005" 0.0005" | 0.001 0.01 | ±0.0004" | ±0.01 | 1 | 1 1/2" | 0.08" | 1/2" | M1.4 | 270° | Yes | Yes | IP65 | 0000000 | 0000000 |
0-0.08" | 0-2 | 0-40-0 | 0-1-0 | 0.00005" 0.0005" | 0.001 0.01 | ±0.0004" | ±0.01 | 1 | 1 1/2" | 0.08" | 1 7/16" | M1.4 | 270° | Yes | Yes | IP65 | 0000000 | 000000 |
Replacement Battery | 0000000 | Each | 00000 |