About Wire and Cable
More
Building Wire
- Use for buildings
- Stranded Wire: Flexible
Solid Wire: Bend and Stay - Temperature Range:
Wire with Nylon Outer Insulation: -10° to 190° F
Wire with Polyethylene Outer Insulation: -40° to 190° F
Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
Wire with a nylon outer insulation resists oil and water. THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement. THWN and THWN-2 wire can be used in both wet and dry environments.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
14 | 19/27 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | ||
12 | 19/25 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | ||
10 | 19/23 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | ||
8 | 19/21 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | ||
6 | 19/19 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | ||
4 | 19/17 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | ||
3 | 19/16 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | ||
2 | 19/15 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 0000 | ||
1/0 | 19/13 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 0000 | ||
2/0 | 19/12 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 0000 |
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
14 | 19/27 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
10 | 19/23 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
8 | 19/21 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
6 | 19/19 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
4 | 19/17 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
3 | 19/16 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000000 | |
2 | 19/15 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000000 | |
1/0 | 19/13 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 | |
2/0 | 19/12 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.1" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | ||
12 | 20 A @ 86° F | 0.12" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 | ||
10 | 30 A @ 86° F | 0.15" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | |||||||
---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.1" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
12 | 20 A @ 86° F | 0.12" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | |
10 | 30 A @ 86° F | 0.15" | THHN, THWN | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 |
Aluminum Building Wire
- Use for buildings
- Flexible
- Temperature Range: -40° to 190° F
Mend or extend aluminum wire often found in older buildings. This wire isn’t recommended for new wiring, since it’s more likely to overheat than copper when conducting electricity. However, it’s safer to maintain existing aluminum wire with aluminum rather than mixing materials. Building wire is also known as branch circuit wire.
This wire has an outer layer of nylon insulation that won't degrade from oil and water. It’s designed to be pulled through conduit without pulling lubricants. THHN and THWN-2 designated, this wire can be used in damp places.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | 25 ft. | 50 ft. | 100 ft. | 250 ft. | 500 ft. | |
Stranded Wire with Nylon Plastic Outer and PVC Plastic Inner Insulation | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC/600V DC | |||||||||||
6 | 55 A @ 86° F | 0.24" | Black | THHN, THWN-2 | UL Listed | 0000000 | |||||
4 | 75 A @ 86° F | 0.3" | Black | THHN, THWN-2 | UL Listed | 0000000 | |||||
2 | 100 A @ 86° F | 0.36" | Black | THHN, THWN-2 | UL Listed | 0000000 | |||||
1 | 115 A @ 86° F | 0.41" | Black | THHN, THWN-2 | UL Listed | 0000000 | |||||
1/0 | 135 A @ 86° F | 0.45" | Black | THHN, THWN-2 | UL Listed | 0000000 | |||||
2/0 | 150 A @ 86° F | 0.49" | Black | THHN, THWN-2 | UL Listed | 0000000 |
Armored Building Cable
- Use For: Buildings
- Flexible
- Temperature Range:
MC, THHN: 15° to 190° F
MC, XHHW-2: -40° to 190° F - Outer Insulation:
MC, THHN: Aluminum Armor
MC, XHHW-2: Aluminum Armor, PVC Plastic - Inner Insulation:
MC, THHN: PVC Plastic
MC, XHHW-2: Cross-Linked Polyethylene (XLPE)
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Cable with THHN wire stands up to condensation and moisture in basements and other damp environments.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
MC, THHN Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.44" | Black, Green, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
14 | 4 | 14/4 | 15 A @ 86° F | 0.49" | Black, Blue, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
12 | 2 | 12/2 | 20 A @ 86° F | 0.48" | Black, Green, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.51" | Black, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
12 | 4 | 12/4 | 20 A @ 86° F | 0.54" | Black, Blue, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
10 | 2 | 10/2 | 30 A @ 86° F | 0.54" | Black, Green, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.58" | Black, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 | |||||
10 | 4 | 10/4 | 30 A @ 86° F | 0.62" | Black, Blue, Green, Red, White | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, UL 2556 VW-1 | 0000000 |
Building Cable
- Use For:
NM-B, THHN: Buildings
UF-B, THHN: Buildings, Outdoors - Bend and Stay
- Temperature Range: 10° to 190° F
- Insulation: PVC Plastic
Rated for in-wall installation, this cable carries power to wall outlets. Also known as branch circuit wire, it can be used without conduit. It has solid THHN building wires, so the cable will stay in the shape you bend it. The uninsulated ground wire is not counted in the number of wires.
NM-B cable is for dry locations where moisture is not a concern, and often run through walls, ceilings, and concrete blocks.
UF-B cable is for wet locations where cable may be exposed to moisture or humidity. It's often used as underground feeder cable for pumps and lighting. The insulation resists moisture and UV light.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-249 | 250-Up | |
NM-B, THHN Solid Wire | |||||||||||||
600V AC | |||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.37" | 0.16" | White | Black, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 00000 | 00000 | |
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | 0.18" | Blue | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 000 | |
12 | 2 | 12/2 | 20 A @ 86° F | 0.42" | 0.18" | Yellow | Black, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 000 | |
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | 0.19" | Purple | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | 0.49" | 0.21" | Orange | Black, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.63" | 0.22" | Pink | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 719 | 00000000 | 0000 | 0000 | |
UF-B, THHN Solid Wire | |||||||||||||
600V AC | |||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.42" | 0.17" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 000 | |
14 | 3 | 14/3 | 15 A @ 86° F | 0.58" | 0.17" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 000 | |
12 | 2 | 12/2 | 20 A @ 86° F | 0.46" | 0.18" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 20 A @ 86° F | 0.63" | 0.18" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | 0.52" | 0.22" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.73" | 0.22" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 |
Armored Building Cable with Uninsulated Ground Wire
- Use For: Buildings
- Flexible
- Temperature Range: 15° to 190° F
- Insulation:
Outer: Aluminum Armor
Inner: PVC Plastic
Also known as AC cable, this cable has an uninsulated aluminum ground wire that's in constant contact with the aluminum armor, so it can be used for bonding and grounding. The uninsulated ground wire is not counted in the number of wires. The armor acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. All are flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.46" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, UL 2556 VW-1 | 0000000 | |||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.48" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, UL 2556 VW-1 | 0000000 | |||||
12 | 2 | 12/2 | 20 A @ 86° F | 0.5" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, UL 2556 VW-1 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, UL 2556 VW-1 | 0000000 | |||||
10 | 2 | 10/2 | 30 A @ 86° F | 0.56" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, UL 2556 VW-1 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.59" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, UL 2556 VW-1 | 0000000 |
Armored Building Cable with Fittings
- Use For: Buildings
- Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: Steel Armor
Inner: PVC Plastic
Also known as fixture whips, this cable has locknuts and fittings attached to the metal armor to secure to a knockout. The armor acts as conduit to protect the THHN building wires. It has 6" long wire leads for hardwiring to an existing electrical system, and is often used to connect light fixtures.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Includes | Industry Designation | Specifications Met | Lg., ft. | Each | |
Solid Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 000000 |
14 | 4 | 14/4 | 15 A @ 86° F | 0.49" | Black, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
12 | 4 | 12/4 | 20 A @ 86° F | 0.92" | Black, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
Stranded Wire | |||||||||||
600V AC | |||||||||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |