About Wire and Cable
More
About Industry Designation for Cable Insulation
More
Cable
Use this general purpose cable to supply power to equipment.
- Use for: Power Supply
- Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
SJT cable is for use in dry or damp locations. The insulation withstands exposure to humidity and low levels of moisture.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
SJTW cable has a water-resistant outer insulation.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Orange Outer Insulation | ||||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | -40° to 165° | 0.32" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: -40° to 165° F
- Insulation: PVC Plastic
SJTOW cable has an oil- and water-resistant outer insulation.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: -40° to 165° F
- Insulation: PVC Plastic
STOW cable has an oil- and water-resistant outer insulation.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -40° to 220° F
Yellow: -55° to 220° F - Insulation: TPE Rubber
SJEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | 0.33" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | 0.33" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | ||||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | -40° to 220° | 0.39" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | ||||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | -75° to 220° | 0.39" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- EPDM Rubber Outer Insulation: Ultra Flexible
Chlorinated Polyethylene Plastic Outer Insulation: Flexible - Temperature Range: See table
- Insulation:
Outer: See table
Inner: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SJOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The outer insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Outer Insulation Material | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | -40° to 190° | 0.33" | EPDM Rubber | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | -55° to 220° | 0.34" | EPDM Rubber | Black, Green/Yellow, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | 0.39" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
16 | 3 | 16/3 | 13 A @ 86° F | 0.4" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 |
Coiled Cable
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
Ultra-flexible cable extends and retracts more easily than flexible cable.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJOW and SOW have a multipurpose neoprene insulation. SJEOW and SEOW have a TPE rubber insulation that also withstands chemicals.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
300V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16 | 3 | 16/3 | 13 A @ 86° F | 0.37" | 1.5" | Black | Black, Green, White | UL Listed, CSA Certified | 0000000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
600V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16 | 3 | 16/3 | 10 A @ 86° F | 0.42" | 1.5" | Black | Black, Green, White | UL Listed, C-UL Listed | 0000000 |
High-Temperature Cable
The insulation on this cable withstands high-heat applications such as ovens and furnaces. The wires are silver or nickel plated for corrosion resistance.
Use unshielded cable in applications where signal interference is not a concern. It has a layer of fiberglass fabric and mica tape around each wire. The entire cable is wrapped in a layer of fiberglass fabric and mica tape, and then covered in PTFE. The PTFE outer insulation resists chemicals, oil, abrasion, and moisture.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. It has PTFE outer and inner insulation that resists chemicals, oil, abrasion, and moisture.
- Use For: Ovens and Furnaces
- Flexible
- Temperature Range: -40° to 840° F
- Insulation:
Outer: Fiberglass Fabric, Mica, PTFE Plastic
Inner: Fiberglass Fabric, Mica
- Use For: Ovens and Furnaces, Interference Shielding
- Flexible
- Temperature Range: -65° to 390° F
- Insulation: PTFE Plastic
Corrosion-Resistant Cable
- Use For: Boats, Motors, Panel and Equipment (Hook-Up), Power Supply
- Flexible
- Temperature Range: -40° to 230° F
- Insulation:
Outer: Chlorinated Polyethylene Plastic
Inner: See table
The chlorinated polyethylene insulation resists corrosive chemicals and salt water, and the wires are tin plated for corrosion resistance. This cable also withstands oil and solvents. It’s rated UL 1309 for use as marine shipboard cable.
Cable with braided bronze armor has excellent protection against abrasion and other damage.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with Polyolefin Plastic Inner Insulation | |||||||||||
600V AC | |||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.37" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
Stranded Wire with Polyolefin Plastic, Braided Bronze Armor Inner Insulation | |||||||||||
600V AC | |||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.52" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 0000 | 0000 |
Continuous-Flex Cable
Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
16 | 3 | 16/3 | 19 A @ 86° F | 0.28" | 2.1" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
600V AC | ||||||||||||||
16 | 3 | 16/3 | 21 A @ 86° F | 0.3" | 2.04" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 |
- Use For: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
16 | 3 | 16/3 | 21 A @ 86° F | 0.35" | 2.63" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
600V AC | ||||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.35" | 2.38" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 |
Oil-Resistant Continuous-Flex Cable
This cable has an insulation with excellent resistance to oil, so it can be used near motors and equipment that require oil lubrication. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Insulation:
300 and 1000V AC: TPE Rubber Inner Insulation
600V AC: PVC Plastic Inner Insulation
See Table for Outer Insulation - Environment:
300 and 1000V AC: Clean Room
600V AC: Not Rated - Specifications Met:
300 and 1000V AC: UL Recognized Component, C-UL Recognized Component, Flame Rated VW-1
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 45° to 190° | 0.29" | 2.18" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
1,000V AC | ||||||||||||||
16 | 3 | 16/3 | 21 A @ 86° F | -30° to 175° | 0.3" | 2.04" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 0000 | 0000 |
- Use For: Shielded: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Insulation:
600V AC: PVC Plastic Inner Insulation
1,000V AC: TPE Rubber Inner Insulation
See Table for Outer Insulaton - Environment:
600V AC: Not Rated
1,000V AC: Clean Room - Specifications Met:
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
1,000V AC: UL Recognized Component, C-UL Recognized Component, Flame-Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 45° to 190° | 0.38" | 2.85" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 000000 | 00000 | |
1,000V AC | ||||||||||||||
16 | 3 | 16/3 | 21 A @ 86° F | -30° to 175° | 0.37" | 2.52" | Polyurethane Rubber, TPE Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 0000 | 0000 |
No-Conduit-Required Continuous-Flex Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range: 25° to 175° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic, PVC Plastic
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.33" | 2.64" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.41" | 4.1" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 |
High-Voltage Continuous-Flex Flat Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
20,000V DC/28,000V AC | |||||||||||||||
16 | 3 | 16/3 | 26 A @ 86° F | 0.37" | 0.15" | 1.5" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 000000 | 000000 |
Continuous-Flex and -Twist Robotics Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range:
300V AC, 600V AC: -40° to 175° F
1,000V AC: -10° to 175° F - Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
In addition to handling continuous movement, this cable withstands twisting up to 450° without degrading data or signal transmission. It's often used in welding robots and rotary tables. It’s flame rated VW-1 to meet requirements for preventing the spread of flame based on a timed test with vertically suspended material. The polyurethane rubber insulation resists abrasion and oil.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||||
600V AC | ||||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.34" | 4.08" | Black | Black, Green/Yellow | __ | __ | CSA Certified, UL Recognized Component, UL 2556 VW-1 | 0000000 | 000000 | 000000 | |
Shielded Stranded Wire | ||||||||||||||
1,000V AC | ||||||||||||||
16 | 3 | 16/3 | 21 A @ 86° F | 0.31" | 3.3" | Blue | Black, Green/Yellow | Clean Room | ISO Class 1 | C-UL Recognized Component, UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 |
Long-Life Continuous-Flex Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -30° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
With a life span of more than 20 million high-speed flex cycles, this cable lasts twice as long as standard continuous-flex cable so you have to replace cable less frequently. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion, chemicals, and oil.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
High-Temperature Continuous-Flex Cable
- Use For: Automation, Continuous Motion, Ovens and Furnaces
- Continuous Flex
- Temperature Range: -10° to 350° F
- Insulation:
Outer: Silicone Rubber
Inner: FEP Plastic
Bend and flex this silicone-insulated cable in temperatures up to 350° F. It can keep moving in areas twice as hot as most other continuous-flex cables without degrading data or signal transmission. It’s often used inside cable carriers in feeding lines for blast furnaces or in automated welding and cutting systems. This cable resists abrasion and won’t break down from exposure to chemicals and UV light. It meets IEC standards for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
For technical drawings and 3-D models, click on a part number.
Control Cable
- Use For:
Unshielded: Automation
Shielded: Automation; Interference Shielding - Flexible
- Temperature Range: 45° to 190° F
- Insulation: PVC Plastic
Send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. This cable is often used with conveyors, CNC machines, and to connect equipment to a control panel. The PVC insulation resists oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.28" | Gray | Black, Green/Yellow | UL Recognized Component, CSA Certified, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire | |||||||||||
600V AC | |||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.38" | Gray | Black, Green/Yellow | UL Recognized Component, CSA Certified, UL 2556 VW-1 | 0000000 | 0000 | 0000 |
No-Conduit-Required Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands periodic flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.33" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 00000 | 00000 | |
Double-Shielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.35" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 |
Thin-Insulation Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -40° to 220° F
- Insulation: Modified Polyphenylene Ether (mPPE) Plastic
Nearly two-thirds the diameter of standard control cable, this cable fits in tight spaces. The modified polyphenylene ether (mPPE) insulation is less than half the weight of the PVC insulation found on standard control cable, yet is more abrasion and cut resistant. Use it to send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. It’s often used with conveyors, CNC machines, and to connect equipment to a control panel. Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
16 | 3 | 16/3 | 12 A @ 86° F | 0.25" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | 00000 | |
Double-Shielded Stranded Wire | |||||||||||
600V AC | |||||||||||
16 | 3 | 16/3 | 12 A @ 86° F | 0.28" | Gray | Black, Red, White | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Power Cords
Connect equipment and devices to a power supply.
Cords with a 90° elbow plug fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
SJEOW cords have an oil- and water-resistant insulation. The insulation on STW and SJTW cords resists water. Use SJT cords in dry or damp locations.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 3 | 0.33" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 00000 |
16 | 13 | 125V AC | 6 | 0.33" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 000000000 | 0000 |
16 | 13 | 125V AC | 6 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 9 | 0.33" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
90° Elbow NEMA 5-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 8 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 000000 | 00000 |
Light Duty Power Cords
Designed for indoor applications, these cords are often used to power appliances.
Cords with a 90° elbow plug fit flush against a wall outlet for use behind machinery or in areas where space is tight.
SPT cords have a flat cord shape so they fit in tight spaces. The numbers 1, 2, and 3 indicate the relative thickness of the insulation. SPT-3 is the thickest, so it is less flexible but more durable than -1 and -2 cords.
Use SJT cords in dry or damp locations.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Wd. | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
16 | 13 | 125V AC | 6 | __ | 0.38" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 000000 |
16 | 13 | 125V AC | 6 | __ | 0.44" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 8 | __ | 0.38" | PVC Plastic | SPT-2 | 0° to 140° | UL Listed, CSA Certified | Black | 0000000 | 00000 |
16 | 13 | 125V AC | 8 | __ | 0.44" | PVC Plastic | SPT-3 | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 1/2 | 0.31" | __ | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Black | 00000000 | 00000 |
90° Elbow NEMA 5-15 Plug × Wire Leads | ||||||||||||
16 | 13 | 125V AC | 6 | __ | 0.83" | PVC Plastic | SPT-3 | -40° to 140° | UL Listed, C-UL Listed | Gray | 00000000 | 0000 |
Sure-Grip Power Cords
Also known as hospital-grade cords, these cords have an extra-tight connection to prevent them from detaching. The plug is marked with a green dot.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 12 ft. | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified | Gray | 00000000 | 000000 |