About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Cable
Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
SJTW cable has a water-resistant outer insulation.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -40° to 220° F
Yellow: -55° to 220° F - Insulation: TPE Rubber
SJEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: See table
- Insulation: TPE Rubber
SEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
- Use For: Outdoors, Power Supply
- EPDM Rubber Outer Insulation: Ultra Flexible
Chlorinated Polyethylene Plastic Outer Insulation: Flexible - Temperature Range: See table
- Insulation:
Outer: See table
Inner: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SJOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The outer insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Outer Insulation Material | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||||
16 | 2 | 16/2 | 13 A @ 86° F | -40° to 190° | 0.31" | EPDM Rubber | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||||
16 | 2 | 16/2 | 13 A @ 86° F | -55° to 220° | 0.32" | EPDM Rubber | Black, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range:
Black: -40° to 190° F
Yellow: -55° to 220° F - Insulation: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The EPDM rubber insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
16 | 2 | 16/2 | 13 A @ 86° F | 0.37" | Black, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 |
Coiled Cable
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
Ultra-flexible cable extends and retracts more easily than flexible cable.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJOW and SOW have a multipurpose neoprene insulation. SJEOW and SEOW have a TPE rubber insulation that also withstands chemicals.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Low-Voltage Cable
- Use For: Appliances, Vehicles
- Flexible
- Temperature Range: -40° to 175° F
- Insulation: PVC Plastic
Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
For technical drawings and 3-D models, click on a part number.
High-Temperature Cable
The insulation on this cable withstands high-heat applications such as ovens and furnaces. The wires are silver or nickel plated for corrosion resistance.
Use unshielded cable in applications where signal interference is not a concern. It has a layer of fiberglass fabric and mica tape around each wire. The entire cable is wrapped in a layer of fiberglass fabric and mica tape, and then covered in PTFE. The PTFE outer insulation resists chemicals, oil, abrasion, and moisture.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices. It has PTFE outer and inner insulation that resists chemicals, oil, abrasion, and moisture.
- Use For: Ovens and Furnaces
- Flexible
- Temperature Range: -40° to 840° F
- Insulation:
Outer: Fiberglass Fabric, Mica, PTFE Plastic
Inner: Fiberglass Fabric, Mica
- Use For: Ovens and Furnaces, Interference Shielding
- Flexible
- Temperature Range: -65° to 390° F
- Insulation: PTFE Plastic
Abrasion-Resistant Cable
- Use For:
Unshielded: Motors, Power Supply
Shielded: Motors, Power Supply, Interference Shielding - Flexible
- Temperature Range: -20° to 190° F
- Insulation:
Outer: Polyurethane Rubber
Inner: PVC Plastic
A thick insulation resists cuts and abrasion, so this cable can be pulled over rough surfaces without damaging the wires inside. Made of polyurethane rubber, the insulation also resists chemicals, moisture, oil, solvents, and water. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Direct-Burial Cable
- Use For: Buildings, Outdoors
- Flexible
- Temperature Range: 0° to 140° F
Weather-resistant insulation makes this cable suitable for outdoor use and direct burial without conduit.
16-, 14-, and 12-gauge wire is designed for underground, low-voltage lighting equipment, such as landscape lighting. The wires can be separated for installation.
Appliance Cable
- Use For: Appliances
- Flexible
- Temperature Range:
SPT-1: 0° to 140° F
HPN: 0° to 190° F - Insulation:
SPT-1: PVC Plastic
HPN: Polyethylene Plastic
Also known as zip cord, this cable has wires that can be separated for installation. It’s often used in small appliances and has a flat shape to fit in tight spaces.
HPN cable is often used with heating appliances, such as portable heaters and soldering irons.
Continuous-Flex Cable
Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
16 | 2 | 16/2 | 19 A @ 86° F | 0.28" | 2.1" | Gray | Black | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, Flame Rated VW-1, NFPA 79 | 0000000 | 00000 | 00000 |
High-Voltage Continuous-Flex Flat Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
20,000V DC/28,000V AC | |||||||||||||||
16 | 2 | 16/2 | 26 A @ 86° F | 0.26" | 0.15" | 1.5" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Servomotor Continuous-Flex Cable
- Use For: Automation, Continuous Motion, Interference Shielding, Motors
- Continuous Flex
- Temperature Range: -40° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: Polypropylene Plastic
Connect servocontrollers and servomotors in automated equipment and on assembly lines. This cable withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion and oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Cable with power and signal wires sends data such as positioning information from a servomotor to a controller. It has four power wires and two pairs of signal wires.Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Power Wire | Signal Wire | Per Ft. | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-49 | 50-Up | |
Double Shielded—1,000V AC | ||||||||||||||||||
4 | 12 | 12/4 | 2 | 18 | 18/2 | 2 | 16 | 16/2 | 20 A @ 86° F | 0.64" | 4.8" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 000000 | 000000 | |
4 | 10 | 10/4 | 2 | 18 | 18/2 | 2 | 16 | 16/2 | 30 A @ 86° F | 0.71" | 5.33" | Orange | Black, Green/Yellow | UL Recognized Component, CSA Certified, Flame Rated VW-1 | 0000000 | 00000 | 00000 |
Riser-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
16 | 2 | 16/2 | 0.17" | Gray | Black, Red | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
16 | 2 | 16/2 | 0.19" | Gray | Black, Red | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 |
Duct-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
16 | 2 | 16/2 | 0.16" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
16 | 2 | 16/2 | 0.19" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 |
Control Cable
- Use For:
Unshielded: Automation
Shielded: Automation; Interference Shielding - Flexible
- Temperature Range: 45° to 190° F
- Insulation: PVC Plastic
Send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. This cable is often used with conveyors, CNC machines, and to connect equipment to a control panel. The PVC insulation resists oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Power Cords
Connect equipment and devices to a power supply.
SJEOW cords have an oil- and water-resistant insulation. The insulation on STW and SJTW cords resists water.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 6 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
16 | 13 | 125V AC | 6 | 0.32" | PVC Plastic | SJTW | -40° to 140° | UL Listed, C-UL Listed | Black | 00000000 | 0000 |
16 | 13 | 125V AC | 9 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 00000 |