Welding Gas Flashback Arresters for Regulators
Attach these arresters to the outlet connection of a regulator on a torch that cuts steel up to 11" thick. Arresters extinguish flames and have a check valve to stop reverse gas flow. They are reusable; resetting is not required after flashback.
Arresters with right-hand threads are for use with oxygen. Arresters with left-hand threads are for use with acetylene, hydrogen, and propane.
High-flow arresters give you twice the airflow rate compared to standard flashback arresters when they’re used at the same inlet pressure. They are often used with larger torch tips.
Quick-disconnect arresters have a fitting that connects and disconnects them from your torch, so you don't have to thread these arresters on and off with a wrench.
For technical drawings and 3-D models, click on a part number.
Thread Size | Max. Pressure for Oxygen, psi | Material | Specifications Met | Each | |
Standard | |||||
---|---|---|---|---|---|
3/8"-24 | 143 | Brass | EN 730, ISO 5175 | 0000000 | 000000 |
9/16"-18 | 143 | Brass | EN 730, ISO 5175 | 00000000 | 00000 |
High Flow | |||||
9/16"-18 | 143 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
7/8"-14 | 143 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
Quick Disconnect | |||||
9/16"-18 | 143 | Brass | EN 561, ISO 7289 | 00000000 | 000000 |
Pipe Size | Max. Pressure for Oxygen, psi | Material | Specifications Met | Each | |
Standard | |||||
---|---|---|---|---|---|
1/4 | 143 | Brass | EN 730, ISO 5175 | 00000000 | 0000000 |
Max. Pressure, psi | |||||||
---|---|---|---|---|---|---|---|
Thread Size | Acetylene | Hydrogen | Propane | Material | Specifications Met | Each | |
Standard | |||||||
3/8"-24 | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 0000000 | 000000 |
9/16"-18 | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 00000 |
High Flow | |||||||
9/16"-18 | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
7/8"-14 | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
Quick Disconnect | |||||||
9/16"-18 | 15 | 50 | 50 | Brass | EN 561, ISO 7289 | 00000000 | 000000 |
Max. Pressure, psi | |||||||
---|---|---|---|---|---|---|---|
Pipe Size | Acetylene | Hydrogen | Propane | Material | Specifications Met | Each | |
Standard | |||||||
1/4 | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 0000000 |
Max. Pressure, psi | ||||||||
---|---|---|---|---|---|---|---|---|
Thread Size | Oxygen | Acetylene | Hydrogen | Propane | Material | Specifications Met | Pair | |
Standard | ||||||||
9/16"-18 | 143 | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 0000000 |
Welding Gas Flashback Arresters for Torches
These arresters attach directly to torches that cut steel up to 8" thick. They extinguish flames and have a check valve to stop reverse gas flow. They are reusable; resetting is not required after flashback.
Arresters with right-hand threads are for use with oxygen; arresters with left-hand threads are for use with acetylene, hydrogen, and propane.
High-flow arresters give you twice the airflow rate compared to standard flashback arresters when they’re used at the same inlet pressure. They are often used with larger torch tips.
Quick-disconnect arresters have a fitting that connects and disconnects them from your torch, so you don't have to thread these arresters on and off with a wrench.
Male Hose Connection | Female Hose Connection | |||||||
---|---|---|---|---|---|---|---|---|
Thread Size | Thread Type | Thread Size | Thread Type | Max. Pressure for Oxygen, psi | Material | Specifications Met | Each | |
Standard | ||||||||
9/16"-18 | UNF | 9/16"-18 | UNF | 143 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
High Flow | ||||||||
3/8"-24 | UNF | 3/8"-24 | UNF | 143 | Brass | EN 730, ISO 5175 | 0000000 | 00000 |
9/16"-18 | UNF | 9/16"-18 | UNF | 143 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
7/8"-14 | UNF | 7/8"-14 | UNF | 143 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
Quick Disconnect | ||||||||
9/16"-18 | UNF | 9/16"-18 | UNF | 143 | Brass | EN 561, ISO 7289 | 00000000 | 00000 |
Male Hose Connection | Female Hose Connection | Max. Pressure, psi | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Thread Size | Thread Type | Thread Size | Thread Type | Acetylene | Hydrogen | Propane | Material | Specifications Met | Each | |
Standard | ||||||||||
9/16"-18 | UNF | 9/16"-18 | UNF | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
High Flow | ||||||||||
3/8"-24 | UNF | 3/8"-24 | UNF | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 0000000 | 00000 |
9/16"-18 | UNF | 9/16"-18 | UNF | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
7/8"-14 | UNF | 7/8"-14 | UNF | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 000000 |
Quick Disconnect | ||||||||||
9/16"-18 | UNF | 9/16"-18 | UNF | 15 | 50 | 72 | Brass | EN 561, ISO 7289 | 00000000 | 00000 |
Male Hose Connection | Female Hose Connection | Max. Pressure, psi | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thread Size | Thread Type | Thread Size | Thread Type | Oxygen | Acetylene | Hydrogen | Propane | Material | Specifications Met | Pair | |
Standard | |||||||||||
9/16"-18 | UNF | 9/16"-18 | UNF | 143 | 15 | 50 | 50 | Brass | EN 730, ISO 5175 | 00000000 | 0000000 |
Welding Gas Check Valves for Torches
Stop the reverse flow of gas in your torch. Check valves do not stop flashbacks.
Max. Pressure, psi | Male Hose Connection | Female Hose Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Oxygen | Acetylene | Hydrogen | Propane | Thread Direction | Thread Size | Thread Type | Thread Direction | Thread Size | Thread Type | Material | Each | |
125 | __ | __ | __ | Right Hand | 3/8"-24 | UNF | Right Hand | 3/8"-24 | UNF | Brass | 000000 | 000000 |
125 | __ | __ | __ | Right Hand | 9/16"-18 | UNF | Right Hand | 9/16"-18 | UNF | Brass | 000000 | 00000 |
__ | 50 | 50 | 50 | Left Hand | 3/8"-24 | UNF | Left Hand | 3/8"-24 | UNF | Brass | 000000 | 00000 |
__ | 50 | 50 | 50 | Left Hand | 9/16"-18 | UNF | Left Hand | 9/16"-18 | UNF | Brass | 000000 | 00000 |
Welding Gas Check Valves for Regulators