How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Blowguns
These blowguns conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure.
Air Inlet | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Grip Style | Specifications Met | Each | |
Straight | ||||||||||||
Lever Control | ||||||||||||
1/2" | 11 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Brass | Cushion | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 |
1 1/2" | 11 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Brass | Cushion | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
3" | 11 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Steel | Cushion | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
Push-Button Control | ||||||||||||
1/2" | 10 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Powder-Coated Zinc | Brass | Plain | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
Blowguns with Nonmarring Tip
The rubber tip won't damage your workpiece.
Blowguns with angled nozzle can direct air over and around obstacles.
Blowguns | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Replacement Nozzles | Replacement Nozzle Tips | |||||||||||||
Nozzle Lg. | Air Consumption | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Grip Style | Each | Each | Each | |||
Straight Shape with Straight Nozzle | |||||||||||||||
Lever Control | |||||||||||||||
1" | 10 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Nickel-Plated Brass | Rubber | Cushion | 00000000 | 000000 | 00000000 | 00000 | 000000 | 00 |
4 1/4" | 12 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Zinc | Rubber | Plain | 0000000 | 00000 | 0000000 | 0000 | 000000 | 00 |
Push-Tip Control | |||||||||||||||
3" | 8 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Nickel-Plated Brass | Rubber | Plain | 000000 | 00000 | 000000 | 00 | 00000000 | 00000 |
Straight Shape with Angled Nozzle | |||||||||||||||
Lever Control | |||||||||||||||
4 1/4" | 12 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Zinc | Rubber | Plain | 0000000 | 00000 | 0000000 | 0000 | 000000 | 00 |
Pocket Blowguns
Compact enough to carry with you, these guns have a built-in quick-disconnect hose coupling for easy connection to an air line. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
ARO shape couplings are also known as A style.
Industrial shape couplings are also known as M style.
Lincoln shape couplings are also known as L style.
Tru-Flate shape couplings are also known as T style.
Air Inlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet Quick-Disconnect Shape | Nozzle Lg. | Air Consumption | Volume, dBA | Overall Lg. | Max. Inlet Pressure, psi | Coupling Size | Gender | Body Material | Nozzle Tip Material | Each | |
Straight | |||||||||||
ARO | 2" | 16 cfm @ 100 psi | Not Rated | 4 3/4" | 150 | 1/4 | Male | Aluminum | Aluminum | 0000000 | 000000 |
Industrial | 2" | 16 cfm @ 100 psi | Not Rated | 4 3/4" | 150 | 1/4 | Male | Aluminum | Aluminum | 0000000 | 00000 |
Lincoln | 2" | 16 cfm @ 100 psi | Not Rated | 4 3/4" | 150 | 1/4 | Male | Aluminum | Aluminum | 0000000 | 00000 |
Tru-Flate | 2" | 16 cfm @ 100 psi | Not Rated | 4 3/4" | 150 | 1/4 | Male | Aluminum | Aluminum | 0000000 | 00000 |
Low-Noise Blowguns
Designed to reduce noise, these blowguns are quieter than similar standard guns. They conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dB | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Specifications Met | Each | |
Straight | |||||||||||
3 5/8" | 19 cfm @ 100 psi | 89 | 120 | 1/4 | NPT | Female | Aluminum | Aluminum | OSHA Compliant 29 CFR 1910.242 | 00000000 | 000000 |
Chip-Guard Blowguns
Also known as air-shield and safety-shield blowguns, a center airstream blows away debris while an outer air curtain deflects flying chips and dust. These conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dB | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Specifications Met | Each | |
Straight | |||||||||||
1/2" | 11 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Brass | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 |
Valve Seal Repair Kits for Pistol Guns | 0000000 | Each | 000000 |
Inline Blowguns
Operate a blowgun without disconnecting your air tool—this gun fits between the tool and air hose. Good for blowing away debris after using an air-powered sander or grinder. Press the button on the gun to activate airflow. It conforms to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure.
Air Inlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Specifications Met | Each | |
Straight | |||||||||||
7/8" | 10 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Brass | OSHA Compliant 29 CFR 1910.242 | 000000 | 000000 |
Blowguns with Air Hose
Connect the included hose to your air supply and these guns are ready to use. They conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure.
Hose | Air Inlet | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Lg., ft. | Material | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Specifications Met | Each | |
Straight | |||||||||||||
1/2" | 11 cfm @ 100 psi | 12 | Nylon Plastic | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Brass | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 |
1/2" | 11 cfm @ 100 psi | 25 | Nylon Plastic | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Brass | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
Extended-Reach Blowguns
The extra length lets you access hard-to-reach areas. These blowguns conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
For technical drawings and 3-D models, click on a part number.
Blowguns | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Repl. Nozzles | ||||||||||||
Nozzle Lg. | Air Consumption | Volume, dB | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Specifications Met | Each | Each | ||
Straight | |||||||||||||
6" | 11 cfm @ 100 psi | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Zinc | Steel | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 | 0000000 | 000000 |
8" | 11 cfm @ 100 psi | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Zinc | Steel | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 | 0000000 | 00000 |
12" | 11 cfm @ 100 psi | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Zinc | Steel | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 | 0000000 | 00000 |
18" | 11 cfm @ 100 psi | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Zinc | Steel | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 | 0000000 | 00000 |
24" | 11 cfm @ 100 psi | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Zinc | Steel | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 | 0000000 | 00000 |
36" | 11 cfm @ 100 psi | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Zinc | Steel | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 | 0000000 | 00000 |
Extended-Reach Blowguns with Nonmarring Tip
These blowguns include a rubber tip that won't damage your workpiece. The extra length lets you access hard-to-reach areas.
Blowguns with angled nozzle can direct air over and around obstacles. They must be used with the included brass nozzle tip to meet OSHA 29 CFR 1910.242 and conform to requirements for maximum air outlet pressure.
Air Inlet | OSHA Nozzle Tip | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Airflow Control | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Number of Nozzle Tips Included | Nonmarring Nozzle Tip Material | Material | Specifications Met | Each | |
With Angled Nozzle | ||||||||||||||
24" | 11 cfm @ 100 psi | Not Rated | Lever | 120 | 1/4 | NPT | Female | Zinc | 2 | Rubber | Brass | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 |
48" | 11 cfm @ 100 psi | Not Rated | Lever | 120 | 1/4 | NPT | Female | Zinc | 2 | Rubber | Brass | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
Air Inlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Airflow Control | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Each | |
With Straight Nozzle | |||||||||||
15" | 8 cfm @ 100 psi | Not Rated | Push Tip | 150 | 1/4 | NPT | Female | Nickel-Plated Brass | Rubber | 000000 | 000000 |
27" | 8 cfm @ 100 psi | Not Rated | Push Tip | 150 | 1/4 | NPT | Female | Nickel-Plated Brass | Rubber | 000000 | 00000 |
39" | 8 cfm @ 100 psi | Not Rated | Push Tip | 150 | 1/4 | NPT | Female | Nickel-Plated Brass | Rubber | 000000 | 00000 |
Adjustable-Length Blowguns
Increase your reach with the telescoping nozzle. These blowguns conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure.
Air Inlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Specifications Met | Each | |
Straight | |||||||||||
12"-32" | 11 cfm @ 100 psi | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Zinc | ABS Plastic | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 |
High-Airflow Blowguns
These blowguns provide more than two times the airflow of standard guns. They conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure.
Air Inlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Specifications Met | Each | |
Straight | |||||||||||
2 1/2" | 23.6 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Zinc | Aluminum | OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000 |
4 1/2" | 34 cfm @ 95 psi | Not Rated | 150 | 1/4 | NPT | Female | Chrome-Plated Zinc | Aluminum | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
90° Airflow Blowguns
Air flows out of the side of the nozzle to clean air filters, radiators, and inside recesses.
Air Inlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Air Inlet Gender | Body Material | Nozzle Tip Material | Each | |
Straight | ||||||||||
12" | Not Rated | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Steel | Aluminum | 0000000 | 000000 |
24" | Not Rated | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Steel | Aluminum | 0000000 | 00000 |
36" | Not Rated | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Steel | Aluminum | 0000000 | 00000 |
48" | Not Rated | Not Rated | 120 | 1/4 | NPT | Female | Chrome-Plated Steel | Aluminum | 0000000 | 00000 |
Electric Blowguns for Large Areas
Clear dust and debris, test air ducts for leaks, and dry large surfaces without needing a compressed air line. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
Attach the optional vacuum kit (sold separately) to convert the blowgun to a handheld vacuum.
Number of Speeds | Airflow, cfm | Nozzle Lg. | Volume, dBA | Tip OD | O'all Lg. | Body Material | Nozzle Tip Material | Voltage | Cord Lg., ft. | Specifications Met | Each | |
Straight | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 105 | 8" | 93 | 3/4" | 15 1/2" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 000000000 |
1 | 155 | 8" | 92 | 3/4" | 16 1/2" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 00000000 |
2 | 150, 195 | 8" | 93 | 3/4" | 18" | Painted Aluminum | Aluminum | 120V AC | 21 | UL Listed | 0000000 | 00000000 |
2 | 150, 195 | 8" | 94 | 3/4" | 18" | Painted Aluminum | Aluminum | 240V AC | 21 | UL Listed | 0000000 | 00000000 |
Vacuum Kits | 0000000 | Each | 0000000 |
Compressed-Air Blowguns for Large Areas
The most powerful blowguns we offer, these use compressed air to clean and blow debris. They include an adjustable secondary handle that can be mounted anywhere along the nozzle for two-hand operation. Blowguns conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
Blowguns | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Inlet | Repl. Nozzles | |||||||||||
Nozzle Lg. | Air Consumption | Volume, dB | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Body Material | Nozzle Tip Material | Each | Each | ||
Straight | ||||||||||||
Lever Control | ||||||||||||
24" | 185 cfm @ 100 psi | 121 | 120 | 3/4 | NPT | Female | Powder-Coated Aluminum | Aluminum | 0000000 | 0000000 | 0000000 | 0000000 |
36" | 185 cfm @ 100 psi | 121 | 120 | 3/4 | NPT | Female | Powder-Coated Aluminum | Aluminum | 0000000 | 000000 | 0000000 | 000000 |
48" | 185 cfm @ 100 psi | 121 | 120 | 3/4 | NPT | Female | Powder-Coated Aluminum | Aluminum | 0000000 | 000000 | 0000000 | 000000 |
72" | 185 cfm @ 100 psi | 121 | 120 | 3/4 | NPT | Female | Powder-Coated Aluminum | Aluminum | 0000000 | 000000 | 0000000 | 000000 |
Replacement Secondary Handles | 0000000 | Each | 000000 |
Blow-and-Spray Blowguns
Also known as a siphon gun, this blowgun sprays air and liquids at the same time. Push the lever and the airflow creates suction that draws water, cleaning solution, or other liquids through the hose.
Blowguns that conform to OSHA 29 CFR 1910.242 meet requirements for maximum air outlet pressure.
Note: Do not use with flammable liquids.
Air Inlet | Hose | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Maximum Flow Rate | Liquid Inlet Gender | For Liquid Inlet Hose ID | Body Material | Nozzle Tip Material | ID | Lg., ft. | Specifications Met | Each | |
Straight with Straight Nozzle | ||||||||||||||||
4 1/2" | 14 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Not Rated | Male | 1/4" | Zinc | Aluminum | 1/4" | 8 | __ | 0000000 | 000000 |
Straight with Angled Nozzle | ||||||||||||||||
16 1/2" | 10 cfm @ 100 psi | Not Rated | 225 | 1/4 | NPT | Female | Not Rated | Male | 1/4" | Aluminum | Aluminum | 1/4" | 5 | OSHA Compliant 29 CFR 1910.242 | 0000000 | 00000 |
24" | 11 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Not Rated | Male | 1/4" | Zinc | Aluminum | 1/4" | 1 | __ | 0000000 | 00000 |
48" | 11 cfm @ 100 psi | Not Rated | 150 | 1/4 | NPT | Female | Not Rated | Male | 1/4" | Zinc | Aluminum | 1/4" | 15 | __ | 0000000 | 00000 |
Clean-Air Blowguns
Clean surfaces without transferring dust or moisture from the air hose. This blowgun has a replaceable filter that traps particles such as rust and smoke and absorbs moisture. It conforms to OSHA Compliant 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
Blowguns | Repl. Filters | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dBA | Removes Particle Size Down To, microns | Filter Moisture Capacity, oz. | Max. Inlet Pressure, psi | Body Material | Nozzle Tip Material | Specifications Met | Each | Each | ||
Straight | ||||||||||||
3/4" | 10 cfm @ 100 psi | 87 | 0.01 | 1 | 100 | Chrome-Plated Zinc | Brass | OSHA Compliant 29 CFR 1910.242 | 00000000 | 000000 | 00000000 | 000000 |
Hands-Free Static-Eliminating Blowguns
Bend the stand's flexible arm to position the blowgun and it will stay in place. Step on the included foot pedal to activate airflow and static elimination. Good for electronics assembly and clean room applications, this blowgun requires a clean, dry air supply. It conforms to OSHA Compliant 29 CFR 1910.242 requirements for maximum air outlet pressure.
Air Inlet | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Static Neutralizing Distance | Arm Lg. | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Specifications Met | Each | |
Straight | |||||||||||||
7 7/8" | 7.4 cfm @ 100 psi | Not Rated | 1"-36" | 18" | 100 | 1/4 | NPT | Female | Nickel Alloy | 120V AC | C-UL Listed, UL Listed, OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000000 |
Replacement Steel Foot Pedals | 0000000 | Each | 0000000 |
High-Airflow Static-Eliminating Blowguns
This blowgun provides more than three times the airflow of a standard blowgun. Good for electronics assembly and clean room applications, it eliminates static charges and guards against ESD (electrostatic discharge). Gun requires a clean, dry air supply. Blowguns and replacements conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure and OSHA 29 CFR 1910.95 requirements for noise. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dBA | Static Neutralizing Distance | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Specifications Met | Each | |
Straight | ||||||||||||
3 7/16" | 24 cfm @ 100 psi | 85 | 2"-10 ft. | 250 | 1/4 | NPT | Female | 303 Stainless Steel | 120V AC | C-UL Recognized Component, UL Recognized Component, OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 0000000 | 000000000 |
Replacement Blowguns with Cable | 0000000 | Each | 0000000 |
Static-Eliminating Blowguns
Eliminate static charges and guard against ESD (electrostatic discharge) in electronics assembly and clean room applications. This blowgun requires a clean, dry air supply. A filter at the nozzle tip ensures that the air is clean. Gun conforms to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dBA | Static Neutralizing Distance | Removes Particle Size Down To, microns | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Environmental Rating | Specifications Met | Each | |
Straight | ||||||||||||||
7 7/8" | 7.4 cfm @ 100 psi | 97 | 4"-10" | 0.01 | 100 | 1/4 | NPT | Female | Nickel Alloy | 120V AC | Fed. Std. Class 1,000; ISO Class 6 | OSHA Compliant 29 CFR 1910.242 | 00000000 | 000000000 |
O-Rings for Brass Compression Tube Fittings for Air and Water
- For Use With: Air, Lubricated Air, Water
- Temperature Range: -20° to 212° F
Use these O-rings with brass compression tube fittings that have BSPP male threads. They create a seal on the BSPP male threads to guard against leaks.
For technical drawings and 3-D models, click on a part number.
For Pipe Size | For Thread Type | For Gender | O-Ring Material | Max. Pressure | Each | |
1/8 | BSPP | Male | Buna-N Rubber, Steel | 2100 psi @ 72 ° F | 000000000 | 00000 |
1/4 | BSPP | Male | Buna-N Rubber, Steel | 2100 psi @ 72 ° F | 000000000 | 0000 |
3/8 | BSPP | Male | Buna-N Rubber, Steel | 1900 psi @ 72 ° F | 000000000 | 0000 |
1/2 | BSPP | Male | Buna-N Rubber, Steel | 1400 psi @ 72 ° F | 000000000 | 0000 |
3/4 | BSPP | Male | Buna-N Rubber, Steel | 1000 psi @ 72 ° F | 000000000 | 0000 |
1 | BSPP | Male | Buna-N Rubber, Steel | 1000 psi @ 72 ° F | 000000000 | 0000 |
Rings for Quick-Clamp High-Vacuum Fittings for Stainless Steel Tubing
- For Use With: Air
- Temperature Range: 0° to 300° F
- Tubing: Use with 304/304L or 316/316L stainless steel
- Specifications Met: ISO 2861
Use these rings with quick-clamp high-vacuum fittings. They consist of a stainless steel inner ring covered by a fluoroelastomer O-ring.
Rings with screen have a stainless steel screen to filter out large particles.
For technical drawings and 3-D models, click on a part number.
For Tube OD | For Flange OD | For High-Vacuum Flange Size | High Vacuum Connection Type | Inner Ring Material | Max. Vacuum | Max. Pressure | Each | |
Rings | ||||||||
---|---|---|---|---|---|---|---|---|
1/2" | 1.18" | 10 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 00000000 | 00000 |
3/4" | 1.18" | 16 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 00000000 | 0000 |
1" | 1.57" | 25 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 0000000 | 00000 |
1 1/2" | 2.16" | 40 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 0000000 | 00000 |
2" | 2.95" | 50 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 0000000 | 00000 |
Rings with Stainless Steel Screen | ||||||||
3/4" | 1.18" | 16 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 00000000 | 00000 |
1" | 1.57" | 25 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 00000000 | 00000 |
1 1/2" | 2.16" | 40 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 00000000 | 00000 |
2" | 2.95" | 50 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 00000000 | 00000 |
Rings with Aluminum Outer Ring | ||||||||
3/4" | 1.18" | 16 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | Not Rated | 00000000 | 00000 |
1" | 1.57" | 25 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 100 psi @ 72° F | 0000000 | 00000 |
1 1/2" | 2.16" | 40 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 75 psi @ 72° F | 0000000 | 00000 |
2" | 2.95" | 50 | ISO-KF | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 50 psi @ 72° F | 0000000 | 00000 |
Rings for Claw-Clamp and Bolt-Together
High-Vacuum Fittings for Stainless Steel Tubing
- For Use With: Air
- Max. Temperature: 400° F
- Tubing: Use with 304/304L Stainless Steel or 316/316L Stainless Steel
Create airtight seals in high-vacuum systems by placing these rings between two claw-clamp (ISO-K) or bolt-together (ISO-F) fittings. They contain a Viton® fluoroelastomer O-ring—when you clamp or bolt your fittings together, the O-ring compresses to establish the seal.
For technical drawings and 3-D models, click on a part number.
Claw-Clamp Connection | Flanged Connection | Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | For Flange OD | For High-Vacuum Flange Size | High Vacuum Connection Type | For Tube OD | For Flange OD | For High-Vacuum Flange Size | High Vacuum Connection Type | O-Ring | Inner Ring | Max. Vacuum | Each | |
2 1/2" | 3.74" | 63 | ISO-K | 2 1/2" | 5.12" | __ | ISO-F | Viton® Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -9 torr @ 72° F | 0000000 | 000000 |
3" | 4.33" | 80 | ISO-K | 3" | 5.71" | 80 | ISO-F | Viton® Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -9 torr @ 72° F | 000000 | 00000 |
4" | 5.12" | 100 | ISO-K | 4" | 6.5" | 100 | ISO-F | Viton® Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -9 torr @ 72° F | 0000000 | 00000 |
6" | 7.09" | 160 | ISO-K | 6" | 8.86" | 160 | ISO-F | Viton® Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -9 torr @ 72° F | 0000000 | 00000 |