    101 Products

    Voltage Detectors

    Confirm that voltage is present in receptacles, cables, and other electrical components. The detectors have light or sound alerts to indicate voltage.
    Fluke Voltage Detectors
    Image of Product. Front orientation. Voltage Detectors. Fluke Voltage Detectors, Long-Reach-Tip Sensor End.

    Long-Reach-Tip Sensor End

    Long-Reach-Tip Sensor End—Long-reach tips, tests leads with sheathed alligator clips, and test leads with needle tips must touch the electrical component you're testing to sense voltage.
    Batteries
    Sensor End
    Mfr. Model
    No.
    Electrical Safety
    Rating
    AC Voltage,
    V AC
    Measures
    Alert Type
    Certification
    Req.
    Included
    Each
    Long-Reach Tip1AC-IICAT IV, 1,000V90 to 1,000AC VoltageLight, SoundCSA Certified, CSA-US CertifiedYesYes0000000000000
    Long-Reach Tip1LAC-IICAT IV, 1,000V20 to 90AC VoltageLight, SoundCSA Certified, CSA-US CertifiedYesYes000000000000

    Fluke Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Multimeters.
    Rely on the quality and durability of Fluke multimeters when taking voltage, resistance, and other electrical measurements.
    Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC
    Current
    Max. DC
    Current
    Hardware Features
    Display
    Count
    Includes
    Each
    Each
    Average-Sensing AC Calculation
    77IVCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.3%10 amp10 ampOverload Protection6,000Test Leads0000000000000000000000000000
     
    True RMS AC Calculation
    113CAT III, 600VAC Voltage, Capacitance, DC Voltage, Resistance6006002%Lead Storage6,000Test Leads0000000000000000000000000000
    114CAT III, 600VAC Voltage, DC Voltage, Impedance, Resistance6006000.5%Overload Protection6,000Test Leads0000000000000000000000000000
    115CAT III, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance6006000.5%10 amp10 ampOverload Protection6,000Test Leads0000000000000000000000000000
    116CAT III, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature6006000.5%600 μA600 μAOverload Protection6,000Temperature Probe, Test Leads0000000000000000000000000000
    117CAT III, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance6006000.5%10 amp10 ampOverload Protection6,000Test Leads0000000000000000000000000000
    117/323CAT III, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance6006000.5%400 amp10 ampOverload Protection6,000Carrying Case, Fluke 323 True RMS Clamp Meter, Magnetic Hanger, Test Leads0000000000000000000000000000
     

    Fluke High-Accuracy Multimeters

    Image of Product. Front orientation. Multimeters. Fluke High-Accuracy Multimeters.
    These Fluke multimeters provide results at least twice as accurate as standard Fluke multimeters. Fluke is known for quality and durability.
    Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Hardware Features
    Display
    Count
    Includes
    Each
    Each
    Average-Sensing AC Calculation
    83VCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.1%1010Lead Storage, Overload Protection6,000Alligator Clips, Test Leads00000000000000000000000000000
    88VCAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.1%1010Overload Protection20,000High-Impact Holster, Test Leads0000000000000000000000000000
     
    True RMS AC Calculation
    175CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.15%1010Lead Storage, Overload Protection6,000Test Leads000000000000000000000000000
    177CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.09%1010Lead Storage, Overload Protection6,000Test Leads000000000000000000000000000
    179CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.09%1010Lead Storage, Overload Protection6,000Temperature Probe, Test Leads000000000000000000000000000
    87VCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%1010Lead Storage, Overload Protection20,000Alligator Clips, Temperature Probe, Test Leads000000000000000000000000000
    87V/E2CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%1010Lead Storage, Overload Protection20,000Alligator Clips, Carrying Case, Magnetic Hanger, Temperature Probe, Test Leads000000000000000000000000000
     

    Fluke Instrumentation Process Control Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Instrumentation Process Control Multimeters.
    With these combination loop calibrators and multimeters, check for current control loop issues in PLCs, motors, and fans in addition to taking other electrical measurements. When used as a loop calibrator, the current input as well as the percentage of the input scale is shown on the dual display, giving you quick diagnostic information. Fluke is known for quality and durability.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Hardware Features
    Display
    Count
    Includes
    Each
    Each
    True RMS AC Calculation
    787BCAT III, 1,000VAC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.1%0.440.44Lead Storage, Overload Protection4,000Alligator Clips, Test Leads00000000000000000000000000000000
    789CAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.1%0.440.44Overload Protection4,000Alligator Clips, Test Leads000000000000000000000000000000
     

    Fluke Wireless Remote-Reading Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Wireless Remote-Reading Multimeters, Model Number 3000 FC.

    Model Number

    3000 FC

    A wireless connection transmits electrical measurements from the multimeter to a separate display, so you can take measurements in hard-to-reach or potentially dangerous locations. Fluke multimeters are known for quality and durability.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Model Number 3000 FC—Model number 3000 FC uses built-in Bluetooth connectivity to transmit measurements to a computer with a Fluke pc3000 FC connector plugged in (not included) or to a mobile device that has the Fluke Connect app. The multimeter also receives measurements from Fluke Wireless Remote-Reading Clamp-On Current Meters and Fluke Wireless Remote-Reading Voltage Meters (not included).
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    mA
    Max. DC Current,
    mA
    Hardware Features
    Display
    Count
    Includes
    Each
    True RMS AC Calculation
    3000 FCCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.09%400400Lead Storage, Overload Protection6,000Alligator Clips, Test Leads0000000000000
     

    Fluke Data-Logging Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Data-Logging Multimeters.
    Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Software—To download and analyze data on a computer, software is required (not included). Connect your multimeter to a computer with the included USB cord.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Data Log
    Cap.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Hardware Features
    Display
    Count
    Includes
    Each
    Each
    True RMS AC Calculation
    28710,000CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.025%1010Overload Protection50,000Alligator Clips, Test Leads0000000000000000000000000000
    28915,000CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Impedance, Resistance, Temperature1,0001,0000.025%1010Overload Protection50,000Alligator Clips, Test Leads0000000000000000000000000000
     

    Fluke Insulation-Testing Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Insulation-Testing Multimeters.
    Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    mA
    Max. DC Current,
    mA
    Hardware Features
    Display
    Count
    Includes
    Enclosure
    Rating
    Each
    Each
    True RMS AC Calculation
    1577CAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Resistance1,0001,0000.2%400400Overload Protection6,000Alligator Clips, Hard Case, Remote Probe, Test LeadsIP40
    0000000000000000000000000000000
    1587 FCCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.09%400400Overload Protection6,000Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test LeadsIP40
    00000000000000000000000000000
     

    Fluke Water-Resistant Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Water-Resistant Multimeters.
    For taking electrical measurements in washdown environments, choose the durability and quality of Fluke multimeters with an IP67-rated housing.
    Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Hardware Features
    Display
    Count
    Includes
    Enclosure
    Rating
    Each
    Each
    Average-Sensing AC Calculation
    27 IICAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.1%1010Overload Protection6,000Alligator Clips, Test LeadsIP67
    0000000000000000000000000000
     
    True RMS AC Calculation
    28 IICAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%1010Overload Protection6,000Alligator Clips, Temperature Probe, Test LeadsIP67
    00000000000000000000000000
     

    Fluke Hazardous-Location Multimeters

    Image of Product. Front orientation. Multimeters. Fluke, Digital Display.
    These Fluke multimeters are rated for environments where hazardous material is present. They take voltage, resistance, and other electrical measurements. Multimeters have durable sealed housing and are rated IP67 for protection from washdowns and temporary submersion.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Hazardous Location Rating—Indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Display
    Count
    Hazardous Location Rating
    NEC Hazardous Location
    Temp. Classification
    Each
    True RMS AC Calculation
    28 II ExCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.05%10106,000ATEX I M1 Ex Ia I Ma; ATEX II 2 G Ex Ia IIC T4 Gb; Ex Ia IIC T4; IEC Zone 1 Groups IIC, IIB, IIA; IECEx Ex Ia I Ma; IECEx Ex Ia IIC T4 Gb; NEC Class I Divisions 1, 2 Groups A, B, C, D; NEC Zone 1 Groups IIC, IIB, IIA; AEx Ia IIC T4T4 (275° F)0000000000000000
     

    Fluke Clamp-on-Jaw Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Clamp-on-Jaw Multimeters.
    Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Test Leads
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Jaw
    Opening
    Electrical Safety Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Display
    Count
    Includes
    Each
    Each
    Pair
    True RMS AC Calculation
    3251.18"CAT III, 600V; CAT IV, 300VAC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature6006001%4006,000Carrying Case, Temperature Probe, Test Leads00000000000000000000000000000000000000000000
    3552.3"CAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance6001,0001%2,0002,00010,000Alligator Clips, Carrying Case, Test Leads, Test Probes0000000000000000———0———0
    374 FC1.3"CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance1,0001,0001%6006006,000Carrying Case, Test Leads0000000000000000000000000000———0
    376 FC1.3"CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0001%2,500999.96,000Carrying Case, Flexible Current Loop, Test Leads0000000000000000000000000000———0
    3811.34"CAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance1,0001,0001%2,500999.96,000Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads000000000000000000000000000000———0
     

    Fluke Open-Jaw Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Open-Jaw Multimeters.
    Run a cable through the open jaw to test current without interrupting the circuit. These multimeters are especially useful for high current measurements and include test leads to perform other electrical tests. Fluke multimeters are known for quality and durability.
    Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Jaw
    Opening
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Display
    Count
    Includes
    Each
    Each
    Average-Sensing AC Calculation
    T5-6000.5"CAT III, 600VAC Current, AC Voltage, DC Voltage, Resistance6006001%1001,000Test Leads0000000000000000000000000000
    T5-10000.5"CAT IV, 600VAC Current, AC Voltage, DC Voltage, Resistance1,0001,0001%1001,000Test Leads00000000000000000000000000
     

    Fluke Vibrating Voltage Meters

    Image of Product. Front orientation. Voltage Meters. Fluke Vibrating Voltage Meters.
    Detect voltage with three types of alerts for extra safety—light, sound, and vibration. There are LEDs that light up to show the approximate voltage level, and a digital LCD shows precise voltage measurements. Fluke meters are known for quality and durability.
    Batteries
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Voltage Increments
    Max.
    Resistance
    Alert Type
    Display Type
    Display
    Features
    Includes
    Lead
    Lg.
    Certification
    Req.
    Included
    Each
    T+ProCAT IV, 600VAC Voltage, Continuity, DC Voltage, Resistance12V, 24V, 48V, 120V, 208V, 240V, 277V, 480V, 600V10 kΩLight, Sound, VibrationDigital, Light IndicatorBacklightTest Leads34"UL Listed, C-UL ListedYesYes00000000000000

    Fluke Wireless Remote-Reading Voltage Meters

    Image of Product. Front orientation. Voltage Meters. Fluke Wireless Remote-Reading Voltage Meters.
    Measure voltage from a distance with these wireless connection-enabled meters that transmit readings to a separate display. Fluke is known for quality and durability.
    The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
    True RMS AC Calculation—The true RMS meter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. These 1,000-count meters show numbers up to 999.
    Batteries
    Mfr. Model
    No.
    AC
    Calculation
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    Display
    Type
    Display
    Features
    Data Log
    Cap.
    Display
    Count
    Includes
    Certification
    Req.
    Included
    Each
    v3000 FCTrue RMSCAT IV, 600VAC Voltage1,000DigitalBacklight65,0001,000Alligator Clips, Magnetic Hanger, Test LeadsCSA Certified, CSA-US CertifiedYesYes000000000000000
    v3001 FCCAT IV, 600VDC Voltage1,000DigitalBacklight65,0001,000Alligator Clips, Magnetic Hanger, Test LeadsCSA Certified, CSA-US CertifiedYesYes00000000000000

    Fluke Test Lead Tips

    Image of Product. Front orientation. Test Lead Tips. Fluke Test Lead Tips.
    Adapt Fluke test leads to perform electrical tests in tight spaces. Attach these tips to test leads that have 4 mm banana plugs.
    Test End
    Mfr. Model
    No.
    For Fluke Model No.
    Test End
    Component
    Connection End
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Current,
    amp
    Electrical Safety
    Rating
    Color
    Material
    Insulation
    Material
    Pair
    TP183V, 87V, 175, 177, 179, 373, 374, 376, 381, 787, 789, T+PRO, T5-1000, T5-600Needle TipStandard Banana Jack1,0001,00010CAT II, 1,000VBlack, RedStainless Steel
    Polypropylene
    0000000000000

    Fluke Test Lead Sets

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number FTPL-1.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL175.

    Model Number FTPL-1

    Model Number TL175

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL222.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL224.

    Model Number TL222

    Model Number TL224

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL26A.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL27.

    Model Number TL26A

    Model Number TL27

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL28A.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL40.

    Model Number TL28A

    Model Number TL40

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL71.
    Image of Product. Front orientation. Exploded view. Test Leads. Fluke Test Lead Sets, Model Number TL75.

    Model Number TL71

    Model Number TL75

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL76.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL910.

    Model Number TL76

    Model Number TL910

    Connect to Fluke multimeters with a set of red and black test leads.
    The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
    Mfr. Model
    No.
    For Fluke Model No.
    Test End
    Connection End
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Current,
    amp
    Electrical Safety Rating
    Certification
    No. of
    Cords
    Cord
    Lg.
    Color
    Test End Material
    Pair
    FTPL-1289Notched Threaded Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified248"Black, RedNickel-Plated Brass000000000000000
    TL17577IV, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289Notched Threaded Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified248"Black, RedNickel-Plated Brass0000000000000
    TL22283V, 87V, 787Sheathed Banana PlugSheathed Standard Banana Plug1,0001,00010CAT III, 1,000V; CAT IV, 600VCSA Certified, CSA-US Certified260"Black, RedCopper0000000000000
    TL22487V, 107, 179, 233, 287, 3000Sheathed Banana PlugSheathed Standard Banana Plug1,0001,00010CAT III, 1,000V; CAT IV, 600VCSA Certified, CSA-US Certified260"Black, RedCopper0000000000000
    TL26A83V, 87V, 88V/A, 107, 179, 287, 289Serrated Alligator ClipSheathed Standard Banana Plug30308CSA Certified, CSA-US Certified260"Black, RedNickel-Plated Copper0000000000000
    TL27107, 175, 177, 179, 787Sheathed Banana PlugSheathed Standard Banana Plug1,0001,00010CAT III, 1,000VCSA Certified, CSA-US Certified260"Black, RedCopper0000000000000
    TL28A88V/A, 107, 175, 177, 179, 287, 289Serrated Alligator ClipSheathed Standard Banana Plug303010CAT I, 30VCSA Certified, CSA-US Certified260"Black, RedCopper0000000000000
    TL4083V, 87V, 88V/A, 287, 289, 787Retractable Probe TipSheathed Standard Banana Plug6006003CAT II, 600VCSA Certified, CSA-US Certified248"Black, RedStainless Steel0000000000000
    TL7127 II, 28 II, 83V, 87V, 88V, 114, 115, 116, 117, 175, 177, 179, 233, 787, 789Notched Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified248"Black, RedNickel-Plated Brass0000000000000
    TL7583V, 87V, 113, 175, 177, 179, 287, 289, 787, 789Notched Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified248"Black, RedNickel-Plated Brass0000000000000
    TL7687V, 107, 179, 287, 289, 787Pointed Threaded Probe TipSheathed Standard Banana Plug1,0001,00010CAT II, 1,000VCSA Certified, CSA-US Certified248"Black, RedNickel-Plated Brass0000000000000
    TL91083V, 87V, 287, 289, 787Pointed Probe TipSheathed Standard Banana Plug1,0001,0003CAT II, 1,000VCSA Certified, CSA-US Certified240"Black, RedGold-Plated Copper0000000000000

    Fluke Test Lead Kits

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Kits.
    These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
    The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
    Mfr. Model
    No.
    For Fluke Model No.
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Current,
    amp
    Electrical Safety
    Rating
    Includes
    Cord
    Lg.
    Color
    Each
    TL22027 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 7891,0001,00010CAT II, 1,000VTwo Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug
    Two Needle Tips
    Two Insulated Plunger Style Alligator Clips
    59"Black, Red00000000000000
    TLK-22527 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 15871,0001,0001CAT IV, 600VTwo Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug
    Two Needle Tips
    Two Insulated Alligator Clips
    Two Retractable Grabbers
    Two Retractable Precision Grabbers
    Two Retractable Precision Hooks
    Pouch
    59"Black, Red0000000000000
    TLK289287, 289, 376, 3811,0001,0003CAT II, 1,000VTwo Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug
    Two Needle Tips
    Two Insulated Alligator Clips
    Two Retractable Grabbers
    Two Retractable Precision Hooks
    Thermocouple
    Magnetic Hanger
    Pouch
    59"Black, Red0000000000000

    Fluke Current-Sensing Test Leads

    Image of Product. Front orientation. Test Leads. Fluke Current-Sensing Test Leads, Current Clamp.

    Current Clamp

    Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
    The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
    These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
    Mfr. Model
    No.
    Test End
    For Max.
    Cord Dia.
    Connection End
    AC Current,
    amp
    Current
    Accuracy
    Current Output Signal per
    amp Supplied, mA
    For Current
    Range
    AC Voltage,
    V AC
    Electrical Safety
    Rating
    Freq. Range
    Jaw
    Opening
    For Fluke Model No.
    Cord
    Lg.
    Batteries
    Req.
    Each
    Measures AC Current
    i400Current Clamp1.25"Sheathed Standard Banana Plug1 to 4002%1.0001 amp to 400 amp1,000CAT IV, 600V5 Hz to 20 kHz1.25"27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 158759"No00000000000000
     

    Magnetic Fluke Multimeter Hangers

    Image of ProductInUse. Front orientation. Multimeter Hangers.
    Image of Product. Front orientation. Multimeter Hangers.
    Free up your hands while using your Fluke multimeter by suspending it from this hanger.
    Mfr. Model
    No.
    For Fluke Model No.
    Each
    TPAK77IV, 83V, 87V, 88V, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 789, 1577, 15870000000000000

    Fluke Multimeter Cases

    Image of Product. Front orientation. Multimeter Cases. Fabric Case.
    Image of Product. Front orientation. Multimeter Cases. Hard Case.
    Image of Product. Front orientation. Multimeter Cases. Leather Case.
    Image of Product. Front orientation. Multimeter Cases. Tool Bag.
    Image of Product. Front orientation. Multimeter Cases. Fabric Holster.

    Fabric Case

    Hard Case

    Leather

    Case

    Tool Bag

    Fabric

    Holster

    Mfr. Model
    No.
    Case Type
    Performance
    For Fluke Model No.
    Each
    C25Fabric Case83V, 87V, 88V, 175, 177, 179, 787, 789, 1577, 15870000000000000
    C35Fabric Case83V, 87V, 113, 233000000000000
    C101Hard Case27 II, 28 II, 83V, 87V, 287, 1577, 1587, T5-600, T5-10000000000000000
    C116Fabric Case233, 287, 289000000000000
    C520ALeather CaseT5-600, T5-1000000000000000
    C550Tool Bag27 II, 28 II, 77IV, 83V, 87V, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289, 324, 355, 373, 374, 376, 381, 787, 789, 1577, 1587, 3000 FC, T5-600, T5-10000000000000000
    CXT170Hard CaseWeatherproof114, 115, 116, 117, 175, 177, 179, 787, 1577, 15870000000000000
    CXT80Hard CaseWeatherproof287, 2890000000000000
    H5Fabric HolsterT5-600, T5-1000000000000000

    Fluke Oscilloscope/Multimeters

    Image of Product. Front orientation. Oscilloscope/Multimeters.
    Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke oscilloscope/multimeters are known for quality and durability.
    To download and analyze data on a computer, software is required (not included).
    When used as an oscilloscope, the oscilloscope/multimeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
    True RMS AC Calculation—The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. This 5,000-count oscilloscope/multimeter shows numbers up to 4,999.
    Mfr. Model
    No.
    No. of Digital
    Channels
    Freq.,
    MHz
    Electrical Safety
    Rating
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Display
    Count
    Data Log
    Cap.
    Includes
    Certification
    Measures
    Batteries
    Included
    Each
    True RMS AC Calculation
    123B20 to 20CAT IV, 600V6006000.5%5,000512Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test LeadsCSA Certified
    AC Voltage, Capacitance, Continuity, DC Voltage, TemperatureYes0000000000000000
     

    Fluke Test Lead Sensors

    Image of Product. Front orientation. Test Lead Sensors. Fluke Test Lead Sensors, Model Number 80BK-A.
    Image of Product. Front orientation. Test Lead Sensors. Fluke Test Lead Sensors, Model Number 80TK.

    Model Number 80BK-A

    Model Number 80TK

    Take temperature readings with a Fluke multimeter.
    Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
    Model Number 80TK—Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm standard banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
    Mfr. Model
    No.
    For Fluke Model No.
    Temp. Range,
    ° F
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Test End
    Component
    Connection End
    Cord
    Lg.
    Test End Insulation
    Material
    Each
    80BK-A28 II, 87V, 116, 179, 233, 287, 289-40 to 500Needle TipSheathed Standard Banana Jack39"PTFE
    0000000000000
    80TK27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789-40 to 5002460Needle TipSheathed Standard Banana Plug39"PTFE
    0000000000000
    back to top