About Actuated On/Off Valves
More
About Gradual On/Off Valves
More
About Flanged Flow-Adjustment Valves
More
About On/Off Valves
More
About Backflow-Prevention Valves
More
Flanged On/Off Valves
Bolt these valves to ANSI flanges. Their lockable lever handle can be fixed in place using a padlock (not included). These valves have four mounting holes for attaching an actuator.
316 stainless steel valves are more corrosion resistant than cast iron or steel valves.
Full-port valves do not restrict flow.
Standard-port valves slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
- Valve Type: Ball
- For Use With: Air, Oil, Steam, Water
- Seal Material: PTFE Plastic
- Specifications Met: ASME B16.10, ASME B16.5, MSS-SP-72
Bolts | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Pressure Class | Flange OD | Circle Dia. | No. of Holes | Hole Size | Included | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Temp. Range, °F | End-to-End Lg. | For Max. Shackle Dia. | Actuator Mounting Hole Thread Size | Each | |
Flanged × Flanged with Full Port | |||||||||||||||
6 | 150 | 11" | 9 1/2" | 8 | 0.88" | No | 5,470 | 200 psi @ 150° F | 125 psi @ 215° F | -20° to 350° | 10 1/2" | 1/4" | M12 × 1.75 mm | 0000000 | 000000000 |
- Valve Type: Ball
- For Use With:
Full Port: Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon, Steam
Standard Port: Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon - Seal Material: PTFE Plastic
- Specifications Met:
Full Port: ASME B16.10, ASME B16.5
Standard Port: ASME B16.34
Bolts | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Pressure Class | Flange OD | Circle Dia. | No. of Holes | Hole Size | Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | Vacuum Rating, in. of Hg | End-to-End Lg. | For Max. Shackle Dia. | Actuator Mounting Hole Thread Size | Each | |
Flanged × Flanged with Standard Port | |||||||||||||||
6 | 150 | 11" | 9 1/2" | 8 | 0.88" | No | 1,020 | 275 psi @ 100° F | -20° to 450° | Not Rated | 10 1/2" | 3/8" | 5/8"-11 | 00000000 | 000000000 |
Socket-Connect On/Off Valves for Drinking Water
- Valve Type: Ball
- For Use With: Drinking Water
- Seal Material: EPDM Rubber
- Specifications Met: NSF/ANSI 61
Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. These valves meet NSF/ANSI 61, which means they’re safe to use with drinking water systems. All have a T-handle that resists accidental movement when snagged or bumped. They are full port, so they do not restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Pipe Schedule | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | End-to-End Lg. | Color | Each | |
PVC Plastic Body | |||||||||
---|---|---|---|---|---|---|---|---|---|
Socket Connect × Socket Connect | |||||||||
6 | 40, 80 | 7,942 | 150 psi @ 70° F | 40° to 140° | 26 | 14 1/4" | Dark Gray | 0000000 | 0000000 |
Threaded Gradual On/Off Valves
Also known as gate valves, these gradually open and close to prevent system damage from suddenly starting and stopping flow.
Pull handles open and close faster than wheel handles.
Rising stems lift as the valve opens and lower as the valve closes to provide a visual indication of whether flow is on or off. The stem is isolated from the process media for a longer service life than valves with a nonrising stem.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
- Valve Type: Gate
- For Use With: Oil, Air, Argon, Helium, Krypton, Neon, Xenon
O'all | ||||||||
---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Each | |
NPT Female | ||||||||
6 | 2,150 | 5 psi @ 1000° F | -40° to 1000° | 3 13/16" | 18 5/8" | 8" | 0000000 | 0000000 |
Flanged Gradual On/Off Valves
Handle, Nonrising
Stem, and Eight Bolt Holes
Rising Stem, and
Eight Bolt Holes
Rising Stem, and
Eight Bolt Holes
Bolt these valves to flanges. They gradually open and close to prevent system damage from suddenly starting and stopping flow.
Epoxy-coated cast iron valves are more corrosion resistant than plain cast iron or steel valves.
Wheel handles open and close with multiple turns, providing more controlled, shock-resistant flow than pull handles.
Pull handles open and close faster than wheel handles.
Nonrising stems stay in the same position whether the valve is open or closed. Valves with nonrising stems are often used underground and in other low-clearance locations.
Rising stems lift as the valve opens and lower as the valve closes to provide a visual indication of whether flow is on or off. The stem is isolated from the process media for a longer service life than valves with a nonrising stem.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
- Valve Type: Gate
- For Use With: Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon, Steam
O'all | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Bolt Hole Dia. | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Pressure Class | Max. Pressure | Max. Steam Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Each | |
6 | 7/8" | 11" | 9 1/2" | 8 | 125 | 200 psi @ 150° F | 125 psi @ 350° F | -20° to 450° | 10 1/2" | 26 1/2" | 10 1/2" | 00000000 | 000000000 |
- Valve Type: Gate
- For Use With: Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon, Steam
O'all | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Bolt Hole Dia. | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Pressure Class | Max. Pressure | Max. Steam Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Each | |
6 | 7/8" | 11" | 9 1/2" | 8 | 125 | 200 psi @ 150° F | 125 psi @ 350° F | -20° to 450° | 10 1/2" | 32 1/8" | 10" | 0000000 | 000000000 |
- Valve Type: Gate
- For Use With: Water, Air
- Specifications Met: ASME B16.10, ASTM A126 Class B, AWWA C509, MSS-SP-70
O'all | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Bolt Hole Dia. | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Pressure Class | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Each | |
6 | 7/8" | 11" | 9 1/2" | 8 | 125 | 200 psi @ 140° F | 35° to 140° | 10 1/2" | 22 5/16" | 10 1/2" | 00000000 | 000000000 |
- Valve Type: Gate
- For Use With: Water, Air
- Specifications Met: ASME B16.10, ASTM A126 Class B, AWWA C509, FM Approved, MSS-SP-70, UL Listed
O'all | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Bolt Hole Dia. | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Pressure Class | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Each | |
6 | 7/8" | 11" | 9 1/2" | 8 | 125 | 200 psi @ 140° F | 35° to 140° | 10 1/2" | 29 1/4" | 10 1/2" | 00000000 | 000000000 |
- Valve Type: Gate
- For Use With: Oil, Air, Argon, Helium, Krypton, Neon, Xenon
- Packing Material: Graphite
O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Bolt Hole Dia. | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolts Included | Flow Coefficient (Cv) | Pressure Class | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Each | |
6 | 7/8" | 11" | 9 1/2" | 8 | No | 2,150 | 125 | 5 psi @ 1000° F | -40° to 1000° | 5 3/4" | 20" | 8" | 0000000 | 000000000 |
Flanged Gradual On/Off Valves for Thick Liquids and Dry Materials
- Valve Type: Gate
- For Use With: Air, Argon, Deionized Water, Ethanol, Ethylene Glycol, Helium, Isopropyl Alcohol, Krypton, Methanol, Neon, Nitrogen, Salt Water, Soap Solutions, Water, Xenon
These valves have a sharp gate that slices through thick slurries, wastewater, dry bulk solids, and other materials that would clog other gradual on/off valves. They bolt to flanges and gradually open and close to prevent system damage from suddenly starting and stopping flow. The wheel handle opens and closes the valve with multiple turns, providing controlled, shock-resistant flow. The rising stem lifts as the valve opens and lowers as the valve closes to provide a visual indication of whether flow is on or off. The stem is isolated from the process media for a long service life.
For technical drawings and 3-D models, click on a part number.
O'all | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | Bolt Hole Dia. | Bolt Circle Dia. | No. of Bolt Holes | Bolts Included | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Stem Type | Each | |
Cast Iron Body—316 Stainless Steel Gate | |||||||||||||
6 | 11" | 3/4" | 9 1/2" | 8 | No | 150 psi @ 248° F | -22° to 248° | 2 1/2" | 34 7/16" | 9 3/8" | Rising | 0000000 | 000000000 |
Plastic Socket-Connect Gradual On/Off Valves
Female ×
Socket-Connect Female
- Valve Type: Gate
- For Use With: Water
For a lightweight and economical alternative to metal valves, these are made of plastic. Insert unthreaded pipe into the socket ends and bond with PVC primer and cement to create a permanent, leak-tight connection. Valves gradually open and close to prevent system damage from suddenly starting and stopping flow. Pull the handle to open the valve. All valves have a rising stem that lifts as the valve opens and lowers as the valve closes to provide a visual indication of whether flow is on or off.
304 stainless steel gates are more durable than glass-filled polypropylene gates.
For technical drawings and 3-D models, click on a part number.
O'all | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Ht. | Lg. | Stem Type | Color | Each | |
Socket Connect Female × Socket Connect Female | |||||||||
PVC Plastic Body—304 Stainless Steel Gate | |||||||||
6 × 6 | 10 psi @ 120° F | 35° to 120° | 11 1/8" | 31 1/8" | 6 5/8" | Rising | White | 0000000 | 0000000 |
Flanged Air-Driven On/Off Valves
- Valve Type: Butterfly
- For Use With: Water, Air, Argon, Helium, Neon, Steam, Xenon, Krypton, Drinking Water
- Seal Material : EPDM Rubber
- Specifications Met: API 609, NSF/ANSI 61
To automatically start and stop flow faster than motor-driven valves, these operate on compressed air. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). Valves don’t require a minimum pressure drop between the inlet and outlet for operation.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages. Valves meet NSF/ANSI 61 for use with drinking water.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are normally closed unless actuated. Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied, so they do not have a valve starting position.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | Air | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Connection | Pressure Range, psi | Each | |
Ductile Iron Body with Screw Terminals | |||||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed)—120V AC | |||||||||||||||
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 2 3/16" | 22 1/2" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000000 |
Double Acting: Air-to-Open, Air-to-Close—120V AC | |||||||||||||||
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | -30° to 250° | 2 3/16" | 19 15/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
Air-Driven On/Off Valves for Fuel
- Valve Type: Butterfly
- For Use With: Oil, Diesel Fuel, Ethylene Glycol, Kerosene, Butane, Fuel Oil, Gasoline, Natural Gas, Propane
- Seal Material : Viton® Fluoroelastomer Rubber
- Specifications Met: API 609, MSS-SP-67
Use these valves to safely transfer fuel and oil. They operate on compressed air to automatically start and stop flow faster than motor-driven valves. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). These valves don’t require a minimum pressure drop between the inlet and outlet for operation.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are normally closed unless actuated. Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied, so they do not have a valve starting position.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | Air | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Connection | Pressure Range, psi | Each | |
Ductile Iron Body with Screw Terminals | |||||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed)—120V AC | |||||||||||||||
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 2 3/16" | 23 5/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000000 |
Double Acting: Air-to-Open, Air-to-Close—120V AC | |||||||||||||||
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 2 3/16" | 20 9/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
Flanged Motor-Driven On/Off Valves
- Valve Type: Butterfly
- For Use With: Water, Oil, Air, Natural Gas, Drinking Water, Propane, Butane, Argon, Helium, Neon, Steam, Xenon, Krypton
- Seal Material: EPDM Rubber
- Specifications Met: API 609, NSF/ANSI 61
Automatically start and stop flow in flanged pipelines with these valves that operate on electricity. All are fail in place; upon loss of power, the valve will remain in its current position.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. Valves meet NSF/ANSI Standard 61 for use with drinking water.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Valves with a manual override can be operated during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Port Type | Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Manual Override | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Ductile Iron Body with Screw Terminals | ||||||||||||||||
Fail in Place—24V AC/DC | ||||||||||||||||
Full | 6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 27 | -30° to 250° | 2 3/16" | 24 13/16" | 0000000 | 000000000 |
Fail in Place—120V AC | ||||||||||||||||
Full | 6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | Yes | 27 | -30° to 250° | 2 3/16" | 24 13/16" | 0000000 | 00000000 |
Motor-Driven On/Off Valves for Fuel
- Valve Type: Butterfly
- For Use With: Oil, Natural Gas, Propane, Butane, Diesel Fuel, Ethylene Glycol, Fuel Oil, Gasoline, Kerosene
- Seal Material: Viton® Fluoroelastomer Rubber
- Specifications Met: API 609, MSS-SP-67
Use these valves to safely transfer fuel and oil. They operate on electricity to automatically start and stop flow. All are fail in place; upon loss of power, the valve will remain in its current position.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. The manual override allows you to operate the valve during power outages.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Ductile Iron Body with Screw Terminals | ||||||||||||||
Fail in Place—24V AC/24V DC | ||||||||||||||
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 27 | 10° to 350° | 2 3/16" | 27 7/16" | 0000000 | 000000000 |
Fail in Place—120V AC | ||||||||||||||
6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 27 | 10° to 350° | 2 3/16" | 27 7/16" | 0000000 | 00000000 |
Flow-Adjustment Valves with Grooved-End Fittings
- Valve Type: Butterfly
- For Use With: Water
- Specifications Met: MSS-SP-67
Commonly used in water service pipelines and HVAC systems, these valves have grooved ends that connect to pipe with a clamp (not included) for easy installation. Since there’s no heat or threading required, they provide quick access to your pipeline for routine maintenance. All gradually open and close to adjust and regulate flow. Valves have 10 flow-adjustment positions. Fix the lockable lever handle in place using a padlock (not included) with a shackle diameter up to 5/16”.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size | For Max. Shackle Dia. | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, ° F | End-to-End Lg. | Ht. | Lg. | Each | |
Polyamide-Coated Ductile Iron Body | |||||||||
Grooved End × Grooved End | |||||||||
6 | 5/16" | Not Rated | 300 psi @ 70° F | -20° to 200° | 5 7/8" | 14 1/16" | 17 3/8" | 0000000 | 0000000 |
Flanged Flow-Adjustment Valves
Also known as butterfly valves, these bolt to flanges for adjusting and regulating flow in flanged pipelines.
Wafer valves must be sandwiched between two flanges; they have tabs or unthreaded holes to help align the valve between the flanges.
Lug valves can be sandwiched between two flanges or bolted directly to a single flange for servicing one end of the pipeline without depressurizing the other side. They have threaded flange holes with a hole pattern that matches ANSI flanges of the same pipe size.
Lockable lever handles can be fixed in place with a padlock (not included).
Wheel handles open and close with multiple turns, providing fully adjustable flow.
316 stainless steel valves are more corrosion resistant than ductile iron valves.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
- Valve Type: Butterfly
- For Use With:
Painted Ductile Iron Disc: Air
Ductile Iron Disc: Water - Specifications Met:
Painted Ductile Iron Disc: MSS-SP-67
Ductile Iron Disc: API 609, MSS-SP-67
Pipe Size | For Max. Shackle Dia. | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Ductile Iron Body—Painted Ductile Iron Disc | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 5/16" | 125, 150 | 11" | 9 1/2" | 4 | 3/4" | No | 1,579 | 200 psi @ 180° F | 10° to 180° | 2 1/4" | 00000000 | 0000000 |
6 | 5/16" | 125, 150 | 11" | 9 1/2" | 4 | 3/4" | No | 1,579 | 200 psi @ 275° F | -30° to 275° | 2 1/4" | 00000000 | 000000 |
Ductile Iron Body—Ductile Iron Disc | |||||||||||||
6 | 1/4" | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | Not Rated | 250 psi @ 180° F | -20° to 180° | 2 5/16" | 0000000 | 000000 |
6 | 1/4" | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | Not Rated | 250 psi @ 225° F | -20° to 225° | 2 5/16" | 00000000 | 000000 |
- Valve Type: Butterfly
- For Use With:
Painted Ductile Iron Disc: Air
Ductile Iron Disc: Water - Specifications Met:
Painted Ductile Iron Disc: MSS-SP-67
Ductile Iron Disc: API 609, MSS-SP-67
Pipe Size | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Ductile Iron Body—Ductile Iron Disc | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | Not Rated | 250 psi @ 180° F | -20° to 180° | 2 5/16" | 0000000 | 0000000 |
6 | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | Not Rated | 250 psi @ 225° F | -20° to 225° | 2 5/16" | 00000000 | 000000 |
- Valve Type: Butterfly
- For Use With: See table
- Specifications Met: See table
Pipe Size | For Max. Shackle Dia. | For Use With | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Specifications Met | Each | |
Ductile Iron Body—Painted Ductile Iron Disc | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 5/16" | Air | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | 1,579 | 200 psi @ 180° F | 10° to 180° | 2 1/4" | MSS-SP-67 | 00000000 | 0000000 |
6 | 5/16" | Air | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | 1,579 | 200 psi @ 275° F | -30° to 275° | 2 1/4" | MSS-SP-67 | 00000000 | 000000 |
Ductile Iron Body—Ductile Iron Disc | |||||||||||||||
6 | 1/4" | Water | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | Not Rated | 250 psi @ 225° F | -20° to 225° | 2 5/16" | API 609, MSS-SP-67 | 00000000 | 000000 |
6 | 1/4" | Oil | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | Not Rated | 250 psi @ 180° F | -20° to 180° | 2 5/16" | API 609, MSS-SP-67 | 0000000 | 000000 |
316 Stainless Steel Body—316 Stainless Steel Disc | |||||||||||||||
6 | 3/16" | Water, Oil, Air | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | 2,901 | 150 psi @ 210° F | 0° to 210° | 2 7/16" | __ | 0000000 | 00000000 |
6 | 3/16" | Water, Air | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | No | 2,901 | 150 psi @ 250° F | -40° to 250° | 2 7/16" | __ | 0000000 | 00000000 |
- Valve Type: Butterfly
- For Use With:
Painted Ductile Iron Disc: Air
Ductile Iron Disc: Water - Specifications Met:
Painted Ductile Iron Disc: MSS-SP-67
Ductile Iron Disc: API 609, MSS-SP-67
Pipe Size | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | For Bolt Diameter | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Ductile Iron Body—Ductile Iron Disc | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | 3/4" | No | Not Rated | 250 psi @ 180° F | -20° to 180° | 2 5/16" | 0000000 | 0000000 |
6 | 125, 150 | 11" | 9 1/2" | 8 | 3/4" | 3/4" | No | Not Rated | 250 psi @ 225° F | -20° to 225° | 2 5/16" | 00000000 | 000000 |
Lightweight Flanged Flow-Adjustment Valves
- Valve Type: Butterfly
- For Use With: See table
An aluminum body provides strength and durability at half the weight of other metal flanged flow-adjustment valves. These valves bolt to flanges for adjusting and regulating flow in flanged pipelines. Fix the lockable lever handle in place using a padlock (not included) with a shackle diameter up to 5/16”. Valves are wafer style, so they must be sandwiched between two flanges; all have unthreaded holes or tabs to help align the valve between the flanges.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Use With | For Max. Shackle Dia. | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Aluminum Body—316 Stainless Steel Disc | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | Water, Oil, Air | 3/16" | 125, 150 | 11" | 9 1/2" | 8 | 0.88" | No | 1,900 | 150 psi @ 210° F | 0° to 210° | 2 3/8" | 0000000 | 0000000 |
6 | Water, Air | 3/16" | 125, 150 | 11" | 9 1/2" | 8 | 0.88" | No | 1,900 | 150 psi @ 250° F | -40° to 250° | 2 3/8" | 0000000 | 000000 |
Plastic Flanged Flow-Adjustment Valves
- Valve Type: Butterfly
- For Use With: Water, Oil
Often used in low-pressure water pipelines, these valves have a plastic body for the lightest weight of our flanged flow-adjustment valves. Bolt them to flanges for adjusting and regulating flow in flanged pipelines. Fix the lockable lever handle in place using a padlock (not included) with a shackle diameter up to 3/16”. Valves are wafer style, so they must be sandwiched between two flanges. They have unthreaded holes that do not match the ANSI flange pattern; use two of the four holes to align the valve between the flanges.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Max. Shackle Dia. | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
PVC Plastic Body—PVC Plastic Disc | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 3/16" | 125, 150 | 11" | 9 1/2" | 4 | 0.88" | No | 1,309 | 150 psi @ 70° F | 40° to 140° | 2 13/16" | 0000000 | 0000000 |
Flanged Flow-Adjustment Valves for Chemicals
With seats that can stand up to aggressive and corrosive solutions, these valves are often used in chemical-processing applications. They bolt to flanges for adjusting and regulating flow in flanged pipelines.
Wafer valves must be sandwiched between two flanges; they have tabs or unthreaded holes to help align the valve between the flanges.
Lug valves can be sandwiched between two flanges or bolted directly to a single flange for servicing one end of the pipeline without depressurizing the other side. They have threaded flange holes with a hole pattern that matches ANSI flanges of the same pipe size.
Lockable lever handles have 10 flow-adjustment positions. The handle can be fixed in place with a padlock (not included).
Wheel handles open and close with multiple turns, providing fully adjustable flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
- Valve Type: Butterfly
- For Use With:
Painted Ductile Iron Disc:
Air, Carbon Dioxide, Diesel Fuel, Isopropyl Alcohol, Methyl Ethyl Ketone, Nitrogen, Oxygen, Toluene
316 Stainless Steel Disc:
Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid - Seat Material: Fluoroelastomer Rubber
- Specifications Met:
Painted Ductile Iron Disc: MSS-SP-67
316 Stainless Steel Disc: API 609, MSS-SP-67
Pipe Size | For Max. Shackle Dia. | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Ductile Iron Body—Painted Ductile Iron Disc | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 5/16" | 150, 125 | 11" | 9 1/2" | 4 | 7/8" | No | 1,579 | 200 psi @ 275° F | 10° to 275° | 2 1/4" | 000000000 | 000000000 |
Ductile Iron Body—316 Stainless Steel Disc | |||||||||||||
6 | 1/4" | 150, 125 | 11" | 9 1/2" | 8 | 7/8" | No | Not Rated | 250 psi @ 210° F | -20° to 210° | 2 5/16" | 0000000 | 00000000 |
- Valve Type: Butterfly
- For Use With:
Painted Ductile Iron Disc:
Air, Carbon Dioxide, Diesel Fuel, Isopropyl Alcohol, Methyl Ethyl Ketone, Nitrogen, Oxygen, Toluene
316 Stainless Steel Disc:
Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid - Seat Material: Fluoroelastomer Rubber
- Specifications Met:
Painted Ductile Iron Disc: MSS-SP-67
316 Stainless Steel Disc: API 609, MSS-SP-67
Pipe Size | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Ductile Iron Body—316 Stainless Steel Disc | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 150, 125 | 11" | 9 1/2" | 8 | 7/8" | No | Not Rated | 250 psi @ 210° F | -20° to 210° | 2 5/16" | 0000000 | 000000000 |
- Valve Type: Butterfly
- For Use With: See table
- Seat Material:
Ductile Iron Body: Fluoroelastomer Rubber
Cast Iron Body: PTFE-Lined Buna-N Rubber - Specifications Met:
Painted Ductile Iron Disc: MSS-SP-67
Ductile Iron Body—316 Stainless Steel Disc: API 609, MSS-SP-67
Pipe Size | For Use With | For Max. Shackle Dia. | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Ductile Iron Body—Painted Ductile Iron Disc | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | Air, Carbon Dioxide, Diesel Fuel, Isopropyl Alcohol, Methyl Ethyl Ketone, Nitrogen, Oxygen, Toluene | 5/16" | 150, 125 | 11" | 9 1/2" | 8 | 7/8" | No | 1,579 | 200 psi @ 275° F | 10° to 275° | 2 1/4" | 000000000 | 0000000 |
Ductile Iron Body—316 Stainless Steel Disc | ||||||||||||||
6 | Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid | 1/4" | 150, 125 | 11" | 9 1/2" | 8 | 7/8" | No | Not Rated | 250 psi @ 210° F | -20° to 210° | 2 5/16" | 0000000 | 00000000 |
Cast Iron Body—316 Stainless Steel Disc | ||||||||||||||
6 | Water, Oil, Argon, Helium, Krypton, Neon, Xenon | 5/16" | 150, 125 | 11" | 9 1/2" | 8 | 7/8" | No | 2,020 | 150 psi @ 150° F | 10° to 150° | 2 5/16" | 000000000 | 00000000 |
- Valve Type: Butterfly
- For Use With:
Painted Ductile Iron Disc:
Air, Carbon Dioxide, Diesel Fuel, Isopropyl Alcohol, Methyl Ethyl Ketone, Nitrogen, Oxygen, Toluene
316 Stainless Steel Disc:
Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid - Seat Material: Fluoroelastomer Rubber
- Specifications Met:
Painted Ductile Iron Disc: MSS-SP-67
316 Stainless Steel Disc: API 609, MSS-SP-67
Pipe Size | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
Ductile Iron Body—316 Stainless Steel Disc | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 150, 125 | 11" | 9 1/2" | 8 | 7/8" | No | Not Rated | 250 psi @ 210° F | -20° to 210° | 2 5/16" | 000000 | 000000000 |
Plastic Flanged Flow-Adjustment Valves for Chemicals
- Valve Type: Butterfly
- For Use With: Water, Carbon Dioxide, Citric Acid, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Phosphoric Acid, Salt Water
- Seat Material: Fluoroelastomer Rubber
- Specifications Met: FM Approved
In addition to fluoroelastomer seats that resist a wide range of chemicals, these valves have no metal parts to corrode, so they’re often used for chemical-processing applications in corrosive conditions. All bolt to flanges for adjusting and regulating flow in flanged pipelines. Fix the lockable lever handle in place using a padlock (not included) with a shackle diameter up to 7/16”. Valves are wafer style, so they must be sandwiched between two flanges; all have unthreaded holes to help align the valve between the flanges.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Max. Shackle Dia. | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
PVC Plastic Body—PVC Plastic Disc | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 7/16" | 125, 150 | 11" | 9 1/2" | 8 | 7/8" | No | 1,125 | 150 psi @ 70° F | 40° to 140° | 2 3/4" | 0000000 | 000000000 |
CPVC Plastic Body—CPVC Plastic Disc | |||||||||||||
6 | 7/16" | 125, 150 | 11" | 9 1/2" | 8 | 7/8" | No | 1,125 | 150 psi @ 70° F | 40° to 200° | 2 3/4" | 0000000 | 00000000 |
Flanged Flow-Adjustment Valves for Drinking Water
- Valve Type: Butterfly
- For Use With: Drinking Water
- Specifications Met: FM Approved, NSF/ANSI 61
These valves meet NSF/ANSI 61 for use with drinking water. They bolt to flanges for adjusting and regulating flow in flanged pipelines. All have seven flow-adjustment positions. The lockable lever handle can be fixed in place using a padlock (not included) with a shackle diameter up to 7/16”. Valves are wafer style, so they must be sandwiched between two flanges; all have unthreaded holes to help align the valve between the flanges.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Max. Shackle Dia. | Pressure Class | Flange OD | Bolt Circle Dia. | No. of Bolt Holes | Bolt Hole Size | Bolts Included | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | End-to-End Lg. | Each | |
PVC Plastic Body—PVC Plastic Disc | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 7/16" | 125, 150 | 11" | 9 1/2" | 8 | 7/8" | No | 1,125 | 150 psi @ 70° F | 40° to 140° | 2 3/4" | 0000000 | 0000000 |
CPVC Plastic Body—CPVC Plastic Disc | |||||||||||||
6 | 7/16" | 125, 150 | 11" | 9 1/2" | 8 | 7/8" | No | 1,125 | 150 psi @ 70° F | 40° to 200° | 2 3/4" | 0000000 | 00000000 |
Flange-Mount Check Valves
- For Use With: Air, Argon, Helium, Krypton, Neon, Water, Xenon
- Disc Material: Bronze
- Seal Material: Buna-N Rubber
Sandwich these valves between two ANSI flanges for backflow prevention at a fraction of the weight of flanged check valves and a reduced pipeline footprint. ANSI flanges are sold separately. All valves open to allow flow in one direction and close when flow stops or reverses.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | End-to-End Lg. | For Flange Class | Each | |
Cast Iron Body | ||||||||
---|---|---|---|---|---|---|---|---|
Flanged × Flanged | ||||||||
6 | 850 | 200 psi @ 70° F | 1.25 | -20° to 250° | 3" | 125 | 0000000 | 0000000 |
Flanged Check Valves
- For Use With: Air, Steam, Water
- Disc Material:
Pipe Size 4 and smaller: Bronze
Pipe Size 5 and larger: Iron - Seal Material: Bronze
Bolt these valves to ANSI flanges. They open to allow flow in one direction and close when flow stops or reverses. All have a removable cap that provides easy access to internal components for maintenance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flow Coefficient (Cv) | Pressure Class | Max. Pressure | Max. Steam Pressure | Min. Opening Pressure | Temperature Range, °F | End-to-End Lg. | Flange OD | No. of Bolt Holes | Bolt Hole Size | Bolt Circle Dia. | Bolts Included | Includes | Each | |
Cast Iron Body | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flanged × Flanged | |||||||||||||||
6 | 1,060 | 125 | 200 psi @ 70° F | 125 psi @ 353° F | 1 psi | -20° to 405° | 14" | 11" | 8 | 3/4" | 9 1/2" | No | Removable Cap | 0000000 | 000000000 |
Plastic Socket-Connect Check Valves
Also known as backwater valves, these valves prevent backflow of sewage and wastewater in drain, waste, and vent systems. Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. Valves open to allow flow in one direction and close when flow stops or reverses. A removable cap provides easy access to internal components for maintenance.
For technical drawings and 3-D models, click on a part number.
- For Use With: Water
- Pressure Class : Not Rated
- Disc Material: PVC Plastic
- Seal Material: PVC Plastic
Flange-Mount Check Valves for Drinking Water
- For Use With: Drinking Water
- Disc Material: 316 Stainless Steel
- Spring Material: 302 Stainless Steel
- Seal Material: EPDM Rubber
Sandwich these valves between ANSI flanges in drinking water pipelines. ANSI flanges are sold separately. Valves meet NSF/ANSI Standard 61, which designates them as safe to use with drinking water. All open to allow flow in one direction and close when flow stops or reverses.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | End-to-End Lg. | For Flange Class | Each | |
Iron Body | ||||||||
---|---|---|---|---|---|---|---|---|
Flanged × Flanged | ||||||||
6 | 870 | 200 psi @ 300° F | 2 | 0° to 200° | 3" | 125, 150 | 000000 | 0000000 |
Flange-Mount Check Valves for Oil and Fuel
- For Use With: Butane, Diesel Fuel, Fuel Oil, Gasoline, Kerosene, Natural Gas, Oil, Propane
- Disc Material: 316 Stainless Steel
- Seal Material: 316 Stainless Steel
Install these valves between ANSI flanges. ANSI flanges are sold separately. All valves open to allow flow in one direction and close when flow stops or reverses. Body is 316 stainless steel for excellent corrosion resistance.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | End-to-End Lg. | For Flange Class | Each | |
316 Stainless Steel Body | ||||||||
---|---|---|---|---|---|---|---|---|
Flanged × Flanged | ||||||||
6 | 705 | 275 psi @ 70° F | 1.25 | -20° to 1000° | 3 7/8" | 150, 300 | 0000000 | 000000000 |
Flange-Mount Pressure-Relief Discs
Install these discs within the bolt circle of ANSI Class 150 flanges. They break open at the burst pressure to allow unrestricted flow. All are for one-time use. Discs are made of resin-impregnated graphite for resistance to temperature and pressure fluctuations as well as corrosive liquids and gases. They include two gaskets for installation between flanges.
Vacuum-rated discs have supports to resist rupture caused by vacuum.
Operating ratio is the ratio between the normal operating pressure and the burst pressure. Exceeding the operating ratio decreases the service life of the disc. For example, a disc with a burst pressure of 100 psi and an operating ratio of 80% should not be used in a system with an operating pressure greater than 80 psi.
Suction Strainers with Backflow-Prevention Valve
- For Use With:
Bronze Connection: Water
Iron Connection: Water and Oil
PVC Connection: Water, Oil, and Diesel Fuel - Max. Pressure:
Bronze Connection: 400 psi
Iron Connection: 10 psi
PVC Connection: 150 psi - Temp. Range:
Bronze Connection: 32° to 190° F
Iron Connection: 32° to 150° F
PVC Connection: 40° to 140° F
Also known as foot valves, these strainers stop particles from entering your line while preventing backward flow. They are commonly used with reservoirs and tanks.
For technical drawings and 3-D models, click on a part number.