Air Actuators for Flow-Control Valves
These actuators are original manufacturer replacements for Duravalve and RuB valves.
You must control the air to the actuator using either an electric pilot valve (not included) or a manual on/off valve (not included).
Single-acting actuators only require air pressure when actuated; they automatically spring closed when the air turns off.
Double-acting actuators require air pressure to open and close.
For technical drawings and 3-D models, click on a part number.
For Valve Manufacturer Model Number | Each | |
Duravalve DM 240 | ||
---|---|---|
Single Acting: Air-to-Open, Spring Return | ||
AS7212 | 000000 | 0000000 |
AS7213 | 000000 | 000000 |
AS7214 | 000000 | 000000 |
AS7216 | 000000 | 000000 |
AS7217 | 000000 | 000000 |
Double Acting: Air-to-Open, Air-to-Close | ||
AS7202 | 000000 | 000000 |
AS7204 | 000000 | 000000 |
AS7207 | 000000 | 000000 |
RuB S.6439 | ||
Single Acting: Air-to-Open, Spring Return | ||
EA2R64D39-001 | 0000000 | 000000 |
EA2R64E39-001 | 0000000 | 000000 |
EA2R64F39-001 | 0000000 | 000000 |
EA3R64G39-001 | 0000000 | 000000 |
EA3R64H39-001 | 0000000 | 000000 |
EA3R64I39-001 | 0000000 | 000000 |
Double Acting: Air-to-Open, Air-to-Close | ||
EA1D64F39-001 | 0000000 | 000000 |
EA3D64G39-001 | 0000000 | 000000 |
Universal Air Actuators for Flow-Control Valves
Attach these actuators to manual ball valves, butterfly valves, and plug valves with an ISO 5211 hole pattern to automatically start and stop flow with compressed air.
You must control the air to the actuator using either an electric pilot valve (not included) or a manual on/off valve (not included). Use valve stem adapters to mount actuators to smaller ISO 5211 valve stems.
Single-acting actuators only require air pressure when actuated; they automatically spring closed when the air turns off.
Double-acting actuators require air pressure to open and close.
Pilot valves control the air to the actuator.
Limit switches change the position of the visual dome indicator and send an electrical signal to trigger alarms or other equipment when the actuator opens or closes the valve. The indicator displays green when the valve is open and red when the valve is closed. Switches attach to the top of the actuator with the included mounting bracket. All meet NEMA 4X for protection from washdowns, splashing water, corrosive liquid, and dust.
For technical drawings and 3-D models, click on a part number.
Air Connection | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque @ Pressure | Spring Close Torque | Hole Pattern | Actuator Mounting Pattern | For Stem Size, mm | Housing Material | Pipe Size | Gender | Thread Type | Air Pressure Range, psi | Temp. Range, °F | Lg. | Wd. | Ht. | Each | |
83 in.-lbs. @ 80 psi | 71in.-lbs. | ISO 5211 | F04 | 11 | Aluminum | 1/8 | Female | NPT | 40 to 115 | 32° to 175° | 6 1/2" | 2 11/16" | 3 5/8" | 00000000 | 0000000 |
160 in.-lbs. @ 80 psi | 114in.-lbs. | ISO 5211 | F05, F07 | 14 | Aluminum | 1/8 | Female | NPT | 40 to 150 | 0° to 175° | 7 5/8" | 3 3/8" | 4 1/4" | 00000000 | 000000 |
282 in.-lbs. @ 80 psi | 215in.-lbs. | ISO 5211 | F05, F07, F10 | 19 | Aluminum | 1/4 | Female | NPT | 40 to 115 | 32° to 175° | 9 5/16" | 4 3/16" | 5 1/16" | 00000000 | 000000 |
Air Connection | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque @ Pressure | Hole Pattern | Actuator Mounting Pattern | For Stem Size, mm | Housing Material | Pipe Size | Gender | Thread Type | Air Pressure Range, psi | Temp. Range, °F | Lg. | Wd. | Ht. | Each | |
187 in.-lbs. @ 80 psi | ISO 5211 | F04 | 11 | Aluminum | 1/8 | Female | NPT | 40 to 150 | 0° to 175° | 6 1/2" | 2 11/16" | 3 5/8" | 00000000 | 0000000 |
327 in.-lbs. @ 80 psi | ISO 5211 | F05, F07 | 14 | Aluminum | 1/8 | Female | NPT | 40 to 115 | 32° to 175° | 7 5/8" | 3 3/8" | 4 1/4" | 00000000 | 000000 |
703 in.-lbs. @ 80 psi | ISO 5211 | F05, F07, F10 | 19 | Aluminum | 1/4 | Female | NPT | 40 to 115 | 32° to 175° | 9 5/16" | 4 3/16" | 5 1/16" | 00000000 | 000000 |
1,431 in.-lbs. @ 80 psi | ISO 5211 | F07, F10 | 19 | Aluminum | 1/4 | Female | NPT | 40 to 115 | 32° to 175° | 11 1/2" | 4 9/16" | 6 1/16" | 00000000 | 000000 |
Motor-Driven Valve Actuators
Use electricity to start and stop flow to valves automatically. They adhere to standard ISO 5211 dimensions for mounting to valves. Use valve stem adapters to mount actuators to smaller ISO 5211 valve stems.
To prevent electrical burnout from excessive and unexpected loads, these actuators have a torque limiter. They also have a manual override, so you can continue to operate the actuator during power outages. These actuators have single pole, double throw (SPDT) auxiliary switches, which allow you to connect them to temperature-monitoring equipment, programmable logic controllers (PLCs), or conveyor sirens. A flow indicator on the top of the actuator shows whether the valve is open or closed. When the valve is actuated, an internal heater will automatically turn on to prevent motor damage from condensation buildup.
Fail-in-place actuators will remain in their current position if power is lost.
Fail-closed actuators have a battery that will switch the actuator to the closed position if power is lost, protecting downstream equipment from excessive pressure.
Nylon actuators resist cleaners and other chemicals better than aluminum actuators. IP and NEMA rated, they protect against dust and washdowns. IP67-rated actuators also keep out water when submerged.
Aluminum actuators stand up to impact better than nylon actuators. They are IP and NEMA rated, so they protect against dust, washdowns, and have the highest rating for submersion.
For technical drawings and 3-D models, click on a part number.
Torque, in.-lbs. | Actuation Time, sec. | Hole Pattern | Actuator Mounting Pattern | For Stem Size, mm | Housing Material | Frequency, Hz | Wire Connection Type | Temp. Range, °F | Lg. | Wd. | Ht. | Environmental Rating | Each | |
100-240V AC—Fail in Place | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
133 | 10 | ISO 5211 | F03, F04 | 11 | Nylon Plastic | 50/60 | Screw Terminals | 0° to 130° | 6 3/8" | 4 13/16" | 5 9/16" | IP65, NEMA 4 | 0000000 | 0000000 |
150 | 9 | ISO 5211 | F03, F05 | 11 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 6 1/8" | 5 3/8" | 7" | IP68, NEMA 4X | 0000000 | 000000 |
530 | 9 | ISO 5211 | F05, F07 | 14 | Nylon Plastic | 50/60 | Screw Terminals | 0° to 130° | 8 7/16" | 7 1/4" | 8 7/16" | IP67, NEMA 4X | 0000000 | 000000 |
530 | 9 | ISO 5211 | F07, F10 | 14 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 7 3/4" | 6 15/16" | 8 5/8" | IP68, NEMA 4X | 0000000 | 000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Nylon Plastic | 50/60 | Screw Terminals | 0° to 130° | 9 5/16" | 8 5/16" | 9 1/8" | IP67, NEMA 4X | 0000000 | 000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 10 5/8" | 10 7/16" | 12 5/16" | IP68, NEMA 4X | 0000000 | 00000000 |
100-240V AC—Fail Closed | ||||||||||||||
150 | 9 | ISO 5211 | F03, F05 | 11 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 6 1/8" | 5 3/8" | 7" | IP68, NEMA 4X | 0000000 | 000000 |
530 | 9 | ISO 5211 | F07, F10 | 14 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 7 3/4" | 6 15/16" | 8 5/8" | IP68, NEMA 4X | 0000000 | 00000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 10 5/8" | 10 7/16" | 12 5/16" | IP68, NEMA 4X | 0000000 | 00000000 |
24V AC, 24V DC—Fail in Place | ||||||||||||||
133 | 10 | ISO 5211 | F03, F04 | 11 | Nylon Plastic | 50/60 | Screw Terminals | 0° to 130° | 6 3/8" | 4 13/16" | 5 9/16" | IP65, NEMA 4 | 0000000 | 000000 |
150 | 9 | ISO 5211 | F03, F05 | 11 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 6 1/8" | 5 3/8" | 7" | IP68, NEMA 4X | 0000000 | 000000 |
530 | 9 | ISO 5211 | F05, F07 | 14 | Nylon Plastic | 50/60 | Screw Terminals | 0° to 130° | 8 7/16" | 7 1/4" | 8 7/16" | IP67, NEMA 4X | 0000000 | 000000 |
530 | 9 | ISO 5211 | F07, F10 | 14 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 7 3/4" | 6 15/16" | 8 5/8" | IP68, NEMA 4X | 0000000 | 000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Nylon Plastic | 50/60 | Screw Terminals | 0° to 130° | 9 5/16" | 8 5/16" | 9 1/8" | IP67, NEMA 4X | 0000000 | 000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 10 5/8" | 10 7/16" | 12 5/16" | IP68, NEMA 4X | 0000000 | 00000000 |
24V AC, 24V DC—Fail Closed | ||||||||||||||
150 | 9 | ISO 5211 | F03, F05 | 11 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 6 1/8" | 5 3/8" | 7" | IP68, NEMA 4X | 0000000 | 000000 |
530 | 9 | ISO 5211 | F07, F10 | 14 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 7 3/4" | 6 15/16" | 8 5/8" | IP68, NEMA 4X | 0000000 | 00000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 10 5/8" | 10 7/16" | 12 5/16" | IP68, NEMA 4X | 0000000 | 00000000 |
Motor-Driven Flow-Adjustment Valve Actuators
Automatically start, stop, and adjust flow through valves. These actuators receive analog signals from a programmable logic controller (PLC) to regulate flow by controlling how far the valve opens and closes. They adhere to standard ISO 5211 dimensions for mounting to valves. Use valve stem adapters to mount actuators to smaller ISO 5211 valve stems.
To prevent electrical burnout from excessive and unexpected loads, these actuators have a torque limiter. They also have a manual override, so you can continue to operate the actuator during power outages. If power is lost, the actuator will remain in its current position. This is known as fail in place. They also have single pole, double throw (SPDT) auxiliary switches, which allow you to connect these actuators to temperature-monitoring equipment, PLCs, or conveyor sirens. A flow indicator on the top of the actuator shows whether the valve is open or closed. To prevent motor damage from condensation buildup, an internal heater will automatically turn on when the valve is actuated.
Rated IP68 and NEMA 4X, these actuators protect against dust, submersion, and washdown.
For technical drawings and 3-D models, click on a part number.
Input Signal | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque, in.-lbs. | Actuation Time, sec. | Hole Pattern | Actuator Mounting Pattern | For Stem Size, mm | Housing Material | Frequency, Hz | Wire Connection Type | Temp. Range, °F | Current | Voltage | Lg. | Wd. | Ht. | Each | |
100-240V AC—Fail in Place | |||||||||||||||
150 | 9 | ISO 5211 | F03, F05 | 11 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 4mA-20mA | 0V DC-10V DC | 6 1/8" | 5 3/8" | 7" | 0000000 | 0000000 |
530 | 9 | ISO 5211 | F07, F10 | 14 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 4mA-20mA | 0V DC-10V DC | 7 3/4" | 6 15/16" | 8 5/8" | 0000000 | 00000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 4mA-20mA | 0V DC-10V DC | 10 5/8" | 10 7/16" | 12 5/16" | 0000000 | 00000000 |
24V AC, 24V DC—Fail in Place | |||||||||||||||
150 | 9 | ISO 5211 | F03, F05 | 11 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 4mA-20mA | 0V DC-10V DC | 6 1/8" | 5 3/8" | 7" | 0000000 | 000000 |
530 | 9 | ISO 5211 | F07, F10 | 14 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 4mA-20mA | 0V DC-10V DC | 7 3/4" | 6 15/16" | 8 5/8" | 0000000 | 00000000 |
1,680 | 27 | ISO 5211 | F07, F10 | 17 | Aluminum | 50/60 | Screw Terminals | 0° to 130° | 4mA-20mA | 0V DC-10V DC | 10 5/8" | 10 7/16" | 12 5/16" | 0000000 | 00000000 |