About Pipe Size
More
About Pressure Gauges
More
About Pressure Transmitters
More
Vacuum Gauges






Use these gauges with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
Gauges with steel case are more impact resistant than gauges with ABS plastic case.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air
- Accuracy: ±2% Mid Scale (Grade B)
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of Hg | Graduation Marks, in. of Hg | Numeric Increments, in. of Hg |
30 to 0 | 0.5 | 5 |
Bottom Connection | Center Back Connection | |||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Each | Each | ||
NPT Male with Calibration Certificate Traceable to NIST | ||||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 0000000 | 00000000 | 0000000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 00000000 | 000000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 000000 | 00 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 00000000 | 000000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 000000 | 00 |
4 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 000000 | 00 |
- For Use With: Air
- Accuracy: ±2% Mid Scale (Grade B)
Available Vacuum Ranges | |||||
---|---|---|---|---|---|
Vacuum Range | Graduation Marks | Numeric Increments | |||
in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
30 to 0 | 0 to -100 | 0.5 | 2 | 5 | 10 |
Bottom Connection | Center Back Connection | |||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Each | Each | ||
NPT Male with Calibration Certificate Traceable to NIST | ||||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 0000000 | 00000000 | 0000000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 00000000 | 000000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 000000 | 00 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 00000000 | 000000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 | 000000 | 00 |
Vibration- and Corrosion-Resistant Vacuum Gauges






Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial to reduce needle flutter. Use them with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air
- Accuracy: ±1% Mid Scale (Grade A); except
4" Dial Dia.: ±1% Full Scale (Grade 1A)
Available Vacuum Ranges | |||||
---|---|---|---|---|---|
Gauges with NIST Certificate | |||||
Vacuum Range | Graduation Marks | Numeric Increments | |||
in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
2 1/2" Dial Diameter | |||||
30 to 0 | 0 to -100 | 0.5 | 2 | 5 | 10 |
4" Dial Diameter | |||||
30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 10 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
Bottom Connection | ||||||
---|---|---|---|---|---|---|
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 0000000 |
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 000000 |
Center Back Connection | ||||||
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 000000 |
Lower Back Connection | ||||||
NPT Male with Calibration Certificate Traceable to NIST | ||||||
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 000000 |
Ultra-Low Vacuum Gauges


Accommodate applications with very low vacuum with these gauges. Use them with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
Gauges with 304 stainless steel case have better corrosion resistance than gauges with steel case.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air
- Accuracy: ±1.6% Full Scale (Not Graded)
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of H₂O | Graduation Marks, in. of H₂O | Numeric Increments, in. of H₂O |
-100 to 0 | 2 | 20 |
-60 to 0 | 1 | 10 |
-30 to 0 | 0.5 | 5 |
-15 to 0 | 0.2 | 3 |
Bottom Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Each | |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 175° | Black | 000000 | 0000000 |
- For Use With: Air
- Accuracy: ±1% Full Scale (Not Graded)
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of H₂O | Graduation Marks, in. of H₂O | Numeric Increments, in. of H₂O |
-100 to 0 | 2 | 20 |
-60 to 0 | 1 | 10 |
-30 to 0 | 0.5 | 5 |
-15 to 0 | 0.2 | 3 |
Bottom Connection | |||||
---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Each | |
NPT Male with Calibration Certificate Traceable to NIST | |||||
4" | 1/4 | 0° to 140° | 0° to 175° | 000000 | 0000000 |
Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges






Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial that reduces needle flutter. Also known as compound gauges, they measure both pressure and vacuum. Use them with pumps, filters, regulators, compressors, and in suction and process lines.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air and Water
- Accuracy: ±1% Mid Scale (Grade A); except
4" Dial Dia.: ±1% Full Scale (Grade 1A)
Available Pressure Ranges | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pressure Range | Vacuum Range | Graduation Marks | Numeric Increments | ||||||
psi | kPa | in. of Hg | kPa | psi | in. of Hg | kPa | psi | in. of Hg | kPa |
2 1/2" Dial Diameter | |||||||||
0 to 15 | 0 to 100 | 30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 5 | 10 | 50 |
0 to 30 | 0 to 200 | 30 to 0 | 0 to -100 | 1 | 2 | 5 | 10 | 10 | 50 |
0 to 60 | 0 to 400 | 30 to 0 | 0 to -100 | 2 | 2 | 10 | 20 | 30 | 100 |
0 to 100 | 0 to 680 | 30 to 0 | 0 to -100 | 2 | 5 | 10 | 20 | 30 | 200 |
0 to 160 | 0 to 1,100 | 30 to 0 | 0 to -100 | 5 | 10 | 20 | 40 | 30 | 200 |
0 to 200 | 0 to 1,350 | 30 to 0 | 0 to -100 | 5 | 10 | 50 | 50 | 30 | 200 |
0 to 300 | 0 to 2,050 | 30 to 0 | 0 to -100 | 5 | 10 | 50 | 50 | 30 | 500 |
4" Dial Diameter | |||||||||
0 to 15 | 0 to 100 | 30 to 0 | 0 to -100 | 0.5 | 1 | 2 | 3 | 5 | 20 |
0 to 30 | 0 to 205 | 30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 5 | 10 | 50 |
0 to 60 | 0 to 410 | 30 to 0 | 0 to -100 | 2 | 2 | 10 | 10 | 10 | 100 |
0 to 100 | 0 to 680 | 30 to 0 | 0 to -100 | 2 | 5 | 10 | 10 | 30 | 100 |
0 to 160 | 0 to 1,100 | 30 to 0 | 0 to -100 | 5 | 5 | 20 | 20 | 30 | 100 |
0 to 200 | 0 to 1,360 | 30 to 0 | 0 to -100 | 5 | 5 | 20 | 20 | 30 | 200 |
0 to 300 | 0 to 2,050 | 30 to 0 | 0 to -100 | 5 | 10 | 50 | 50 | 30 | 500 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
Bottom Connection | ||||||
---|---|---|---|---|---|---|
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 0000000 |
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
Center Back Connection | ||||||
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
Lower Back Connection | ||||||
NPT Male with Calibration Certificate Traceable to NIST | ||||||
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
Differential Pressure and Vacuum Gauges

Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air
- Accuracy: ±2% Mid Scale (Not Graded); except
0" to 0.2" in. of H2O: ±4% Mid Scale (Not Graded)
0" to 0.25" in. of H2O: ±3% Mid Scale (Not Graded)
Available Pressure and Vacuum Ranges | |||
---|---|---|---|
Pressure Range, in. of H₂O | Vacuum Range, in. of H₂O | Graduation Marks, in. of H₂O | Numeric Increments, in. of H₂O |
0 to 0.2" | 0" to 0 | 0.01 | 0.05 |
0 to 0.25" | 0" to 0 | 0.01 | 0.05 |
0 to 0.5" | 0" to 0 | 0.02 | 0.1 |
0 to 1" | 0" to 0 | 0.05 | 0.25 |
0 to 5" | 0" to 0 | 0.2 | 1 |
0 to 10" | 0" to 0 | 0.5 | 5 |
0 to 15" | 0" to 0 | 1 | 5 |
Dial Diameter | Pipe Size | Max. Pressure, psi | Environment Temp. Range, °F | Process Temp. Range, °F | Features | Includes | Each | |
NPT Female Calibration Certificate Traceable to NIST | ||||||||
---|---|---|---|---|---|---|---|---|
4" | 1/8 | 15 | 20° to 140° | 20° to 140° | Two Inlets and Two Outlets | Plugs for Unused Ports | 0000000 | 0000000 |
Differential Pressure and Vacuum Gauges with Digital Display
Gauges have a four-digit LCD display for easy reading of measurements. Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.

- For Use With: Air
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | kPa | in. of H₂O | mbar | Vacuum Range, in. of Hg | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Batteries Included | Features | Each | |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 0000000 |
0-7.225 | 0-49.82 | 0-200" | 0-498.2 | 14.71"-0 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-20 | 0-137.9 | 0-553" | 0-1,379 | 40.72"-0 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
High-Accuracy Pressure and Vacuum Transmitters

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.25%
- Pipe Connection: NPT Male
- Housing Material: 304 Stainless Steel
- Connection Material: 17-4 PH Stainless Steel
- Temperature Range: -40° to 255° F
With an accuracy of ±0.25%, use these transmitters in applications that require highly accurate measurement of both pressure and vacuum, such as activating vacuum pumps. All come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. They convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated pressure range.
Rated IP67 and NEMA 4X, these transmitters seal out dust and water from temporary submersion. All are CE marked, so they meet European safety standards.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Transmitters with Calibration Certificate Traceable to NIST | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | ||||||||||
0-15 | 29.9-0 | 15 | 30 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 0000000 |
0-25 | 29.9-0 | 25 | 50 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 000000 |
0-50 | 29.9-0 | 50 | 100 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 000000 |
0-100 | 29.9-0 | 100 | 200 | 9-30V DC | 1/4 | 2 1/8" | 1" | IP67, NEMA 4X | 0000000 | 000000 |
High-Accuracy Vacuum Transmitters

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.25%
- Pipe Connection: NPT Male
- Housing Material: 304 Stainless Steel
- Connection Material: 17-4 PH Stainless Steel
- Temperature Range: -40° to 255° F
At least four times as accurate as standard vacuum transmitters, these transmitters sense vacuum at an accuracy of ±0.25%, making them ideal for use in laboratories and in analytical testing applications. All come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. These transmitters, also known as transducers, convert vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor vacuum or control equipment. As vacuum decreases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's vacuum range and output signal. Transmitters will only provide accurate readings within the rated vacuum range.
IP and NEMA rated, these transmitters withstand weather, corrosion, and brief submersion. They’re CE marked, so they meet European safety standards.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn't lose signal over long distances and isn't affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Transmitters with Calibration Certificate Traceable to NIST | |||||||||
---|---|---|---|---|---|---|---|---|---|
Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | |||||||||
29.9-0 | 15 | 15 | 9-30V DC | 1/4 | 1 5/16" | 1" | IP67, NEMA 4X | 0000000 | 0000000 |
Test Gauges for Vacuum




Test and calibrate transmitters, gauges, and other equipment that measures vacuum.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air
- Accuracy: ±0.25% Full Scale (Grade 3A)
Available Vacuum Ranges | ||||||
---|---|---|---|---|---|---|
Vacuum Range | Graduation Marks | Numeric Increments | ||||
Dial Dia. | in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
4 1/2" | 30 to 0 | 0 to 0 | 0.1 | 0.5 | 1 | 5 |
6" | 30 to 0 | 0 to 0 | 0.1 | 0.5 | 1 | 10 |
Bolt | Flange | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Fasteners Included | Circle Dia. | Hole Thread Size | No. of Holes | Location | OD | Each | |
Bottom Connection (Flange Mount) | |||||||||||
NPT Male—Calibration Certificate Traceable to NIST | |||||||||||
4 1/2" | 1/4 | -20° to 200° | -20° to 250° | No | 5 3/8" | 10-24 | 3 | Front | 6 3/32" | 0000000 | 0000000 |
6" | 1/4 | -20° to 200° | -20° to 250° | No | 7" | 1/4"-20 | 3 | Front | 7 9/16" | 0000000 | 000000 |
Lower Back Connection (Flange Mount) | |||||||||||
NPT Male—Calibration Certificate Traceable to NIST | |||||||||||
4 1/2" | 1/4 | -20° to 200° | -20° to 250° | No | 5 3/8" | 10-24 | 3 | Front | 6 3/32" | 0000000 | 000000 |
6" | 1/4 | -20° to 200° | -20° to 250° | No | 7" | 1/4"-20 | 3 | Front | 7 9/16" | 0000000 | 000000 |