The bolted-body design provides strength for a tight seal in vacuum conditions up to 29.9” Hg. Use these valves in vacuum applications, such as coating, heat treating, leak testing, and analyzing gases.
To create a tight seal in vacuum conditions higher than 29.9” Hg, these valves have ultra-high-vacuum tube fitting connections, which are also known as KF, QF, and NW fittings. They are often used in applications such as vacuum coating and heat treating, leak testing, and analyzing gases.
Use these valves in general purpose applications such as those with water, oil, air, and inert gas.
Extend your reach in hard-to-access areas—turn these valves on and off using a square ratchet to grasp the hole at the end of the handle. Use with water, oil, air, and inert gas.
Attach a gauge to the side port on these valves to monitor pressure, temperature, and other measurements in your line. Use with water and air.
An easy-to-read flow-indicating handle shows the percentage the valve is open. These valves are for use with water, oil, inert gas, and steam.
For installation through thick insulation, these valves have an extra-long stem.
With 10-32 UNF threads and a body less than 3/4” long, these valves are often used to control flow in miniature pipelines. They’re rated for use with water, oil, air, and inert gas.
Install these valves in tight spots, such as where pipelines are crowded together. They’re less than half as long as standard threaded valves and one-third shorter in height. Use with water, oil, air, and inert gas.
These valves handle twice the pressure of other compact valves. Install them in tight spots, such as where pipelines are crowded together. Use with water, oil, air, and inert gas.
Maintain and repair these valves without unthreading pipe connections. They have a three-piece bolted body that disassembles inline for access to internal components. Use with water, oil, air, inert gas, and steam.
These valves are rated for at least three times the pressure of standard threaded valves. Use with water, oil, air, inert gas, and steam.
Control the flow of your line while it’s protected behind an instrument panel. These valves have threads and a hex nut below the handle, so it sticks out of your panel for access. They’re for use with water, oil, air, and inert gas.
For fast installation and removal from pipelines, these valves have a union fitting that disassembles into multiple pieces. They’re for use with water, oil, air, inert gas, and steam.
Often used in high-purity applications, such as oxygen service, these valves come cleaned and bagged. Use with water, oil, inert gas, and steam.
A threaded union on these valves makes them easy to install and remove without disrupting your line.
Easily access the handle of these valves while protecting your line behind an instrument panel. Threads and a hex nut below the handle allow you to install these valves in instrument panels. For extra gripping power and a strong seal, they have Yor-Lok fittings with two sleeves that bite into tubing as you tighten the nut. All are compatible with Swagelok®, Let-Lok, and Parker A-Lok fittings.
For extra gripping power and a strong seal, the Yor-Lok fittings on these valves have two sleeves that bite into tubing as you tighten the nut. All are compatible with Swagelok®, Let-Lok, and Parker A-Lok fittings. These valves are for use with water, oil, air, and inert gas.
Weld these valves to unthreaded metal pipe for a permanent, flush connection that permits smooth flow through a line. Use with water, oil, inert gas, and steam.
Bolt these valves to ANSI flanges.
Also known as wafer ball valves, these combine the slim body of a butterfly valve with the high flow rates of a flanged ball valve. Bolt these valves to ANSI flanges—they meet ASME standards for dimensions, material, and pressure-temperature rating. Use with water, oil, air, steam and inert gas such as helium.
Insert tubing into the fittings on these valves—no heat, solder, or flux required. They’re for use with water, oil, air, and inert gas.
For a leak-tight connection that doesn’t require heat or soldering, these valves have press-connect fittings that crimp to metal tubing with a press-connect crimping tool.
Service these valves without cutting soldered connections. The three-piece bolted body can be disassembled inline for easy access to internal components. Use with water, oil, inert gas, and steam.
Solder these valves to metal tubing for a permanent, leak-tight connection. Use with water, oil, air, inert gas, and steam.
Often used for oxygen service and other high-purity applications, these valves come cleaned and bagged. Insert unthreaded pipe into the socket ends and weld to create a permanent, leak-tight connection. For easy maintenance, they have a three-piece bolted body that disassembles inline so you can access internal components without removing welded connections.
Streamline your installation and removal process. These valves give you the leak-tight permanent connection of a socket connect with the ease of fittings that come apart.
Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. These valves have a fluoroelastomer seal and a plastic body that can withstand aggressive and corrosive solutions in chemical-processing applications.
To withstand aggressive and corrosive solutions in miniature chemical-processing pipelines, these tiny valves have a chemical-resistant fluoroelastomer seal and a corrosion-resistant 303 stainless steel body.
The most chemical-resistant threaded valves we offer, these have a PTFE seal and an alloy body that can withstand extremely aggressive and corrosive chemicals, such as methyl ethyl ketone and toluene.
With a fluoroelastomer seal and a CPVC body, these valves can withstand aggressive and corrosive solutions in chemical-processing applications.
For fast installation and removal from pipelines, these valves have union fittings that disassemble into multiple pieces. All have a fluoroelastomer seal and a plastic body that can stand up to aggressive and corrosive solutions in chemical-processing applications.
There’s no need to unbolt these valves for cleaning—remove the valve handle and slide the valve apart for inline access to internal components. Also known as elliptical valves, they have a fluoroelastomer seal and a polypropylene body to withstand aggressive and corrosive solutions in chemical-processing applications.
Bolt these valves to ANSI flanges—they meet ASME dimensional standards. They have a plastic body and a seal that withstand aggressive and corrosive solutions in chemical-processing applications.
Insert unthreaded pipe into the socket ends and bond with primer and cement to create a permanent, leak-tight connection. These valves meet NSF/ANSI 61, which means they’re safe to use with drinking water systems.
Ideal for lines that need frequent maintenance, these valves have union fittings that disassemble quickly for removal. They meet NSF/ANSI 61 for use with drinking water.
These valves meet NSF/ANSI 61 for use in drinking water lines.
Disassemble the union fittings on these valves for fast installation and removal from your pipeline. All meet NSF/ANSI 61 for use with drinking water.
For use in drinking water systems, these valves meet NSF/ANSI 61.
Solder these valves to metal tubing for a permanent, leak-tight connection. They meet NSF/ANSI 61 for use with drinking water.
Insert tubing into the push-to-connect fittings on these valves—no heat, solder, or flux required. They meet NSF/ANSI 51 for safe use with food.
For extra gripping power and a strong seal, these valves have Yor-Lok fittings with two sleeves that bite into tubing as you tighten the nut. They are compatible with Swagelok®, Let-Lok, and Parker A-Lok fittings. Use with diesel fuel, fuel oil, gasoline, and kerosene.
Protect personnel and equipment in the presence of diesel fuel, fuel oil, gasoline, and kerosene. Fire-tested to meet American Petroleum Institute (API) 607, Edition 4, these valves are designed to securely isolate fluid and prevent the spread of fire.
Often used in HVAC or refrigeration systems, these valves are designed to control the flow of ammonia, nitrogen, and other harsh chemicals.
Threads and a hex nut below the handle let you install these valves through instrument panels. They are for use with water, oil, air, and inert gas. All divert flow between ports.
These valves divert flow between ports. Use with water, oil, air, and inert gas.
Control flow in two directions from a single source—these valves have two handles for independent operation of each outlet. Use them with water, oil, and inert gas.
For easy installation and removal from pipelines, all ends on these valves have union fittings that disassemble into multiple pieces. Use with water. Valves divert flow between ports.
To divert flow between ports in drinking water lines, these valves meet NSF/ANSI 61.
For easy installation and removal from pipelines, all ends on these valves have union fittings that disassemble into multiple pieces. Their fluoroelastomer seal and plastic body can withstand aggressive and corrosive solutions for diverting flow between ports in chemical-processing applications.
There’s no need to unbolt these valves for cleaning—remove the handle and slide the valve apart for inline access to internal components. Also known as elliptical valves, they have a fluoroelastomer seal and a polypropylene body for diverting flow in chemical-processing applications.
For use with threaded pipe, these valves have NPT connections. Use them with water, oil, air, and inert gas. All operate on compressed air to automatically divert flow between ports more quickly than motor-driven valves. You must control the air to the actuator using either an electric pilot valve or a manual on/off valve.
Control the flow of water in two directions from a single source—these diverting valves have two balls and handles for independent operation of each outlet. Use with fire-fighting hose.
Control flow in two directions from a single source—these valves have two balls for independent control and shut-off of each outlet.