About Fuses
More
European Fuses
These fuses can be used with equipment made in Europe.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall, mm | Each | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | Protection Type | No. of Elements | Specifications Met | 1-9 | 10-Up | |
Type gL-gG | ||||||||||
1 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 000000 | 000000 |
2 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
4 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
6 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
8 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
10 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
12 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
16 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
20 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
25 | 500V AC | 120,000 A @ 500 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 0000000 | 00000 | 00000 |
32 | 400V AC | 120,000 A @ 400 V AC | 38 | 10 | Fast Acting | 1 | CE Marked | 000000 | 00000 | 00000 |
European Milk Bottle Fuses
Also known as diazed or Type D fuses, these fuses can be used with equipment made in Europe.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
Fuses with a blown fuse indicator have a visual pin that pops out.
For technical drawings and 3-D models, click on a part number.
Overall, mm | Each | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | Tip Dia., mm | Protection Type | No. of Elements | Blown Fuse Indicator | 1-4 | 5-Up | |
Type gL-gG | |||||||||||
2 | 500V AC | 75,000 A @ 500 V AC | 50 | 21.5 | 6 | Fast Acting | 1 | Yes | 0000000 | 00000 | 00000 |
4 | 500V AC | 75,000 A @ 500 V AC | 50 | 21.5 | 6 | Fast Acting | 1 | Yes | 0000000 | 0000 | 0000 |
6 | 500V AC | 75,000 A @ 500 V AC | 50 | 21.5 | 6 | Fast Acting | 1 | Yes | 0000000 | 0000 | 0000 |
10 | 500V AC | 75,000 A @ 500 V AC | 50 | 21.5 | 8 | Fast Acting | 1 | Yes | 0000000 | 0000 | 0000 |
16 | 500V AC | 75,000 A @ 500 V AC | 50 | 21.5 | 10 | Fast Acting | 1 | Yes | 0000000 | 0000 | 0000 |
20 | 500V AC | 75,000 A @ 500 V AC | 50 | 21.5 | 12 | Fast Acting | 1 | Yes | 0000000 | 0000 | 0000 |
25 | 500V AC | 75,000 A @ 500 V AC | 50 | 21.5 | 14 | Fast Acting | 1 | Yes | 0000000 | 0000 | 0000 |
35 | 500V AC | 75,000 A @ 500 V AC | 50 | 27 | 16 | Fast Acting | 1 | Yes | 0000000 | 00000 | 0000 |
50 | 500V AC | 75,000 A @ 500 V AC | 50 | 27 | 18 | Fast Acting | 1 | Yes | 0000000 | 00000 | 0000 |
63 | 500V AC | 75,000 A @ 500 V AC | 50 | 27 | 20 | Fast Acting | 1 | Yes | 0000000 | 00000 | 0000 |