Trace unshielded data and telephone cables to their source. Attach the identifier with the included alligator clips and send a signal through the cable. The signal is then received by the removable handheld probe. As you get closer to the cable you're tracing, the probe's audio and visual signals get stronger.
Measures | For Cable Type | Alert Type | Features | Batteries Included | Each | ||
---|---|---|---|---|---|---|---|
Cable Location | Coaxial, Ethernet, Telephone | Light, Sound | F-Type Male Coaxial Connector, RJ11 Plug, RJ45 Plug, Two Alligator Clips | Yes | 000000 | 0000000 |
Noise-Filtering Line Testing Amplifiers
![]() |
Block out power-line hum when identifying a cable. Use this amplifier with a tone generator or tester to identify a cable without making direct contact with the wire. The tone will get louder the closer you get to the correct cable.
Line Testing Amplifiers
![]() |
Use this amplifier with a tone generator or tester to identify a cable without making direct contact with the wire. The tone will get louder the closer you get to the correct cable.
Tone-Generating Line Testers
![]() | ![]() |
RJ11 Plug | RJ45 Plug |
Generate an audible signal when testing for short circuits, line continuity, or when locating a cable. Use an amplifier (sold separately) to hear the signal. These tone generators have a light signal to verify polarity.
Line Testers | Line Tester Pouches | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Measures | Alert Type | Features | Includes | Batteries Included | No. of Batteries Req. | Battery Size | Each | Each | |||
Cable Location, Continuity, Polarity | Light, Sound | RJ11 Plug | Test Leads with Alligator Clips | No | 1 | 9V | 0000000 | 000000 | 00000000 | 000000 | |
Cable Location, Continuity, Polarity | Light, Sound | RJ45 Plug | Test Leads with Alligator Clips | No | 1 | 9V | 0000000 | 000000 | 00000000 | 00000 |
Circuit Tracers
![]() |
Circuit Tracer |
![]() |
High-Resolution Circuit Tracer |
Identify breakers and ferret out faults without cutting power to critical systems. More versatile than a breaker finder, circuit tracers track the path of an entire energized or de-energized circuit’s wiring through walls, ceilings, and floors. They’ll even detect wires underground without being blocked by conduit or cement.
Each tracer kit includes a transmitter and a wireless receiver. Plug the transmitter’s leads into an outlet or connect its alligator clips to bare conductors to send a signal through the circuit you want to trace. Then, move the receiver against the wall like a stud finder to follow the signal’s path and detect the circuit’s wiring. Boost the receiver’s sensitivity if the signal strength drops as you move away from the transmitter, or dial it down to eliminate false positives from nearby circuits. Keeping the sensitivity low is also useful when you need to single out a specific wire within a bundle.
High-Resolution Circuit Tracer—The safest choice for circuits near your building’s incoming power source, where the risk of injury from power surges is high. Our tracers are rated CAT IV to protect against power surges up to 8,000 V, so they’re safe for use with electricity meters, transformers, outdoor conductors, and other utility-level connections. The kits also include a clamp-on lead. Squeeze its jaws around covered wires to send a tracing signal without interrupting the circuit.
Tester Type | Measures | For Max. Dp., ft. | Alert Type | AC Voltage, V AC | DC Voltage, V DC | Includes | Lead Lg. | Batteries Included | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
Circuit Tracer | Buried Lines, Circuit Breakers, Circuit Shorts, Continuity, Data Cable Location, Fuses, Ground Faults, Wire Location | 3 | Light, Sound, Digital Display | 0 to 600 | 0 to 600 | Transmitter, Receiver, Fabric Carrying Case, Alligator Clips, Test Leads, Electrical Outlet Adapter | 32" | Yes | 00000000 | 0000000 | |
High-Resolution Circuit Tracer | Buried Lines, Circuit Breakers, Circuit Shorts, Continuity, Data Cable Location, Fuses, Ground Faults, Wire Location | 20 | Light, Sound, Digital Display | 0 to 600 | 0 to 600 | Transmitter, Clamp-On Current Transducer, Hard Carrying Case, Alligator Clips, Receiver with Sensitivity Adjustment, Batteries, Socket Adapter, Test Leads | 23 ft. | Yes | 00000000 | 00000000 |
Current Detectors
![]() |
Check for the presence of AC current and voltage without making direct contact with a wire. The detector has light and sound alerts that indicate current when it is held near the electrical component.
Electrical Safety Rating | Measures | AC Current | AC Voltage, V AC | Alert Type | Sensor End | Certification | Batteries Included | Each | ||
---|---|---|---|---|---|---|---|---|---|---|
CAT III, 600V | AC Current, AC Voltage | 200 mA to 1,000 amp | 12 to 600 | Light, Sound | Noncontact | C-UL Listed, UL Listed | Yes | 0000000 | 000000 |
Data Cable Testers with Digital Display
![]() |
A digital display helps you identify open, short, and miswired circuits in data cable. These testers have a built-in tone generator with selectable tones.
Measures Capacitance—Testers that measure capacitance can determine the length of coaxial and Ethernet cable.
Measures | For Cable Type | Digital Display Type | Alert Type | Features | Batteries Included | Each | ||
---|---|---|---|---|---|---|---|---|
Cable Location, Continuity | Coaxial, Ethernet, Telephone | LCD | Light, Sound | F-Type Male Coaxial Connector, RJ11/RJ12 Socket, RJ45 Socket | Yes | 0000000 | 000000 | |
Cable Location, Capacitance, Continuity | Coaxial, Ethernet, Telephone | LCD | Light, Sound | F-Type Male Coaxial Connector, RJ11/RJ12 Socket, RJ45 Socket | Yes | 0000000 | 000000 |
Fluke Vibrating Voltage Meters
![]() |
Detect voltage with three types of alerts for extra safety—light, sound, and vibration. There are LEDs that light up to show the approximate voltage level, and a digital LCD shows precise voltage measurements. Fluke meters are known for quality and durability.
Batteries | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Voltage Increments | Max. Resistance | Alert Type | Display Type | Display Features | Includes | Lead Lg. | Certification | Req. | Included | Each | ||
T+Pro | CAT IV, 600V | AC Voltage, Continuity, DC Voltage, Resistance | 12V, 24V, 48V, 120V, 208V, 240V, 277V, 480V, 600V | 10 kΩ | Light, Sound, Vibration | Digital, Light Indicator | Backlight | Test Leads | 34" | UL Listed, C-UL Listed | Yes | Yes | 0000000 | 0000000 |
Circuit Breaker Identifiers
![]() | ![]() |
120V AC | 80V AC to 300V AC |
Identify the circuit breaker connected to an electrical receptacle. The transmitter plugs into the receptacle and sends a signal through the cable to the receiver. Move the receiver over the breakers, and light and sound alerts indicate when you find the correct breaker.
Circuit Breaker Identifier Adapters—Circuit breaker identifier adapters trace breakers for light bulb sockets and switches.
Circuit Breaker Identifiers | Circuit Breaker Identifier Adapters | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Batteries | |||||||||||||
AC Voltage, V AC | Alert Type | Includes | Plug No. of Blades | Electrical Connection | Certification | Included | Size | No. Required | Each | Each | |||
120 | Light, Sound | Transmitter, Receiver, Test Probe | 3 | Straight Blade | UL Listed, C-UL Listed | No | 9V | 1 | 00000000 | 000000 | 00000000 | 000000 | |
80 to 300 | Light, Sound | Transmitter, Receiver, Alligator Clips, Socket Adapter, Test Leads, Test Probe, Electrical Outlet Adapter | 2 | Straight Blade | UL Listed, C-UL Listed | Yes | 9V | 1 | 00000000 | 000000 | ——— | 0 |
Line Break Detectors
![]() |
Test-Lead Sensor End with Replaceable Alligator Clips |
Check continuity in circuits. If there are no line breaks, light or sound alerts signal continuity.
Voltage Detectors
Confirm that voltage is present in receptacles, cables, and other electrical components. The detectors have light or sound alerts to indicate voltage.
Voltage Detectors
![]() | ![]() | ![]() |
Long-Reach-Tip Sensor End 6V DC to 50V DC | Noncontact Sensor End 12V AC to 1,000V AC | Noncontact Sensor End 50V AC to 1,000V AC |
Long-Reach-Tip Sensor End—Long-reach tips, tests leads with sheathed alligator clips, and test leads with needle tips must touch the electrical component you're testing to sense voltage.
Noncontact Sensor End—Noncontact detectors can sense voltage when brought near the electrical component.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Electrical Safety Rating | DC Voltage, V DC | AC Voltage, V AC | Measures | Alert Type | Certification | Req. | Included | Each | ||
Long-Reach Tip | — | 6 to 50 | — | DC Voltage | Light, Sound | UL Listed, C-UL Listed | No | — | 00000000 | 000000 | |
Noncontact | CAT IV, 600V | — | 12 to 1,000 | AC Voltage | Light, Sound | ETL Listed, C-ETL Listed | Yes | Yes | 00000000 | 00000 | |
Noncontact | CAT IV, 1,000V | — | 50 to 1,000 | AC Voltage | Light, Sound | UL Listed, C-UL Listed | Yes | Yes | 00000000 | 00000 |
Fluke Voltage Detectors
![]() |
Long-Reach-Tip Sensor End |
Long-Reach-Tip Sensor End—Long-reach tips, tests leads with sheathed alligator clips, and test leads with needle tips must touch the electrical component you're testing to sense voltage.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Mfr. Model No. | Electrical Safety Rating | AC Voltage, V AC | Measures | Alert Type | Certification | Req. | Included | Each | ||
Long-Reach Tip | 1AC-II | CAT IV, 1,000V | 90 to 1,000 | AC Voltage | Light, Sound | CSA Certified, CSA-US Certified | Yes | Yes | 0000000 | 000000 | |
Long-Reach Tip | 1LAC-II | CAT IV, 1,000V | 20 to 90 | AC Voltage | Light, Sound | CSA Certified, CSA-US Certified | Yes | Yes | 0000000 | 00000 |
High-Voltage Detectors
![]() |
Safely check for the presence of voltage in high-voltage equipment and lines. This noncontact detector checks for voltage by sensing electrostatic fields when brought near the electrical component. Light and sound alerts indicate voltage.
Hot Stick (48" Long)—For testing 1,500-122,000V AC, a hot stick is required (not included). It attaches to the high-voltage detector to extend your reach and detect voltage from a distance.
Batteries | |||||||||
---|---|---|---|---|---|---|---|---|---|
Sensor End | AC Voltage, V AC | Measures | Alert Type | Includes | Req. | Included | Each | ||
Noncontact | 30 to 122,000 | AC Voltage | Light, Sound | Carrying Case | Yes | Yes | 0000000 | 0000000 |
Voltage Detectors for Hard Hats
![]() |
Shown with Hard Hat (Sold Separately) |
![]() |
Clip these detectors to your hard hat to identify voltage and current from 360°. Without making physical contact, they flash light in the direction of the electrical threat and beep louder as you get closer to it. These lightweight detectors are comfortable to wear all day. They’re often used to identify live conductors, energized lines underground, and residual voltage.
Set the sensitivity level to determine when the detector alerts you. While the battery life varies depending on the number of alerts, a full charge can last up to five days. Recharge the battery with the included USB charging cable or a standard USB 2.0 Micro-B charger.
120V AC to 500 kV AC—120V AC-500kV AC detectors sense voltages as low as those in a power socket and as high as those in high-power transmission lines. Since they detect a wide range of voltages, they’re a helpful tool for rescue workers, electricians, and telecom workers. They can also connect to an app to notify emergency response services when there is a fall, injury, or no movement detected. The app is optional, and it requires a paid subscription. This safety feature makes these detectors a great option for those working alone.
2.4 kV AC to 500 kV AC—2.4kV AC to 500kV AC detectors identify a wide range of voltages found in high-power transmission lines, so they’re often used by linemen. However, they won’t detect the low voltage ranges found in telecom lines or small machinery.
Voltage Detectors | Replacement Hard Hat Clips | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Batteries | ||||||||||||||||
AC Voltage, kV AC | No. of Sensitivity Levels | AC Current, amp | Measures | Life, hr. | Included | Includes | Alert Type | Flammability Rating | Wt., oz. | Enclosure Rating | Features | Each | Each | |||
120 to 500 | 11 | 1 to 200 | AC Current, AC Voltage | 40 | Yes | Carrying Case, USB Charging Cable | Light, Sound | UL 94 V-0 | 0.95 | IP67 | App Connectivity | 0000000 | 0000000 | 0000000 | 00000 | |
2.4 to 500 | 7 | 1 to 200 | AC Current, AC Voltage | 80 | Yes | Carrying Case, USB Charging Cable | Light, Sound | UL 94 V-0 | 0.5 | IP67 | — | 0000000 | 000000 | ——— | 0 |