Miniature Remote-Reading Panel-Mount Thermometers
Install the small display in tight spaces and crowded instrument panels up to 10 feet from the probe.
Probe | Mtg. Holes | For Panel Cutout | Material | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | Lg. | Dia. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | Dp. | Housing | Probe | Batteries Included | Each | |
-40° to 300° F/ -40° to 150° C | 0.1/0.1 | ±1.8° F | 7/8" | 3/16" | 2 | 5/32" | No | 1 1/2" | 2 3/4" | 1 5/8" | 2 15/16" | 1" | Plastic | Stainless Steel | Yes | 0000000 | 000000 |
14° to 230° F/ -10° to 110° C | 0.1/0.1 | ±1° F | 20" | 3/16" | 2 | 3/8" | No | 3 3/4" | 4 3/4" | 3 5/16" | 4 3/4" | 1 1/4" | Plastic | Stainless Steel | Yes | 0000000 | 000000 |
Remote-Reading Panel-Mount Thermometers
Monitor the temperature of difficult-to-access system components from a distance. The probe is connected to a cable, so the dial can be mounted away from your system.
Thermometers that meet NSF/ANSI standards are for use in food processing and preparation areas.
Probe | Mtg. Holes | Material | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Panel Cutout Dia. | Flange OD | Bolt Circle Dia. | No. of | Dia. | Housing | Probe | Temperature Range | Specifications Met | Each | |
Front Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 0.312" | 3" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 000000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 4" | 3/8" | 3" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 120° F/-40° to 50° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 20 | 4" | 3/8" | 3" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | __ | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 0.312" | 3 1/2" | 3 1/2" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | __ | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
Back Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 0.314" | 3 1/2" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | 3 | 9/64" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 3.94" | 3/8" | 3 1/2" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 120° F/-40° to 50° C | __ | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | 3 | 11/64" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | __ | 00000000 | 00000 |
4 1/2" | 4 | 3 1/2" | 3/8" | 4 5/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | __ | 00000000 | 000000 |
4 1/2" | 4 | 3 1/2" | 3/8" | 4 5/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | __ | 00000000 | 000000 |
Bracket Mount | ||||||||||||||
2 1/2" | 4 | 2 1/2" | 3/8" | __ | __ | __ | 1 | 11/64" | Stainless Steel | Nickel Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
Remote-Reading Panel-Mount Freezer Thermometers with Audible Alarm
Protect temperature-sensitive materials in refrigerators and freezers with one of these thermometers that sound an alarm and flash the display when temperature rises above your activation point. Alarm requires a power supply (sold separately).
Probe | Mtg. Holes | For Panel Cutout | Input Voltage | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Actuation Point Temperature Range | Resolution | Accuracy | Cable Lg., ft. | Dia. | Lg. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | AC | DC | Electrical Connection | Frequency, Hz | Each | |
-25° F to 99° F/-32° C to 38° C | -15° F to 50° F/-26° C to 10° C | 1/1 | ±3° F | 6 | 3/8" | 7/8" | 2 | 7/32" | No | 3 7/8" | 2 7/8" | 5" | 3 1/8" | 10.5 to 28 | 12 to 28 | Wire Leads | 60 | 000000 | 0000000 |
12V AC Output/120V AC Input Power Supply | 0000000 | Each | 000000 |
High-Temperature Panel-Mount Thermometers
Often used to remotely monitor probe readings in high-temperature applications, these thermometers have a housing designed for installation in instrument and control panels. They interpret data from a thermocouple probe or RTD probe (sold separately).
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For Thermocouple Probe Type | For RTD Probe Type | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | Electrical Connection | Frequency, Hz | Each | |
-2° to 752° F | 1 | ±3.3° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 0000000 |
0° to 1,000° F | 1 | ±5.0° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
0° to 1,999° F | 1 | ±10.0° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
32° to 428° F | 1 | ±2.8° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-346° to 1,400° F/-210° to 760° C | 1 | ±3.7° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-157° to 752° F/-105° to 400° C | 1 | ±3.7° F | T | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-157° to 1,999° F/-105° to 1,372° C | 1 | ±3.7° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-58° to 200° F/-50° to 199° C | 0.1 | ±0.3° F | __ | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-58° to 1,562° F/-50° to 850° C | 1 | ±2.0° F | __ | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
Quick-Response Food and Beverage Panel-Mount Thermometers
A resistance temperature detector (RTD) probe responds to temperature change faster than dial thermometers.
For technical drawings and 3-D models, click on a part number.
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For RTD Probe Type | Cable Lg., ft. | Dia. | Lg. | Panel Cutout Dia. | AC Voltage | Electrical Connection | Response Time, sec. | Includes | Each | |
-40° to 250° F | 1 | ±2° F | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 0000000 |
-40° to 120° C | 1 | ±2° C | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 000000 |
Remote-Reading Magnetic-Back Thermometers with Calibration Certificate
Externally monitor the air temperature inside freezers, refrigerators, water baths, and incubators. These thermometers come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. They have a probe with a 10-ft. cable that connects to a magnetic-back external display. The probe is insulated in a bottle filled with mercury-free fluid to prevent false readings from rapid temperature changes such as opening freezer doors.
The display simultaneously shows the high, low, and current temperatures. These thermometers have a programmable alarm to indicate when temperature rises above or below your actuation point.
Material | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Accuracy | Resolution | Cable Lg., ft. | Probe Dia. | Response Time, sec. | Ht. | Wd. | Dp. | Housing | Probe | Cable | Fluid | Batteries Included | Each | |
For Use With Air | |||||||||||||||
-58° to 158° F/-50° to 70° C | ±0.9° F/±0.5° C | 0.1/0.1 | 10 | 3/16" | 60 | 4 1/4" | 2 1/2" | 5/8" | Plastic | Glass | PVC Plastic | Glycol | Yes | 0000000 | 000000 |
-58° to 158° F/-50° to 70° C | ±1.8° F/±1.0° C | 1/1 | 10 | 3/16" | 60 | 4 1/4" | 2 3/4" | 3/4" | Plastic | Glass | PVC Plastic | Glycol | Yes | 0000000 | 00000 |
Remote-Reading Magnetic-Back Thermometers
Remotely check temperature on the go. These thermometers have a magnetic-back display for temporary mounting and a thermocouple probe with a 5-ft. coiled cable.
Probe | Material | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range, ° F | Accuracy | Resolution | Thermocouple Probe Type | Lg. | Dia. | Response Time, sec. | Ht. | Wd. | Dp. | Housing | Probe | Cable | Batteries Included | Each | |
For Use With Liquids | |||||||||||||||
-100° to 700° | ±0.25% | 1 | T | 6" | 3/16" | 1 | 2 1/4" | 3" | 1 1/8" | Plastic | Stainless Steel | PVC Plastic | Yes | 00000000 | 0000000 |
-50° to 1000° | ±0.25% | 1 | K | 6" | 3/16" | 1 | 2 1/4" | 3" | 1 1/8" | Plastic | Stainless Steel | PVC Plastic | Yes | 00000000 | 000000 |
-50° to 1200° | ±0.25% | 1 | J | 6" | 3/16" | 1 | 2 1/4" | 3" | 1 1/8" | Plastic | Stainless Steel | PVC Plastic | Yes | 00000000 | 000000 |
Extended-Life Hand-Held Thermometers with Calibration Certificate
For a longer service life than thermocouple probes and more consistent readings over time, these thermometers have a resistance temperature detector (RTD) probe. They come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy.
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Specifications Met | Batteries Included | Each | |
For Use With Air, Gases, Liquids | |||||||||||
-148° to 572° F/-100° to 300° C | 0.01/0.01 | ±0.9° F/±0.5° C | 1 | 1 | 3 | 6" | 1/8" | CE Marked | Yes | 0000000 | 0000000 |
High-Temperature Hand-Held Thermometers with Calibration Certificate
These thermometers have a thermocouple probe that can handle extreme temperatures, and they come with a calibration certificate traceable to NIST that states they have passed a test for accuracy.
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Specifications Met | Batteries Included | Each | |
For Use With Air, Liquids | |||||||||||
-40° to 482° F/-40° to 250° C | 0.1/0.1, 1 | ±3.6° F/±2° C | 1 | 0.5 | 4 | 3/8" | 1/16" | CE Marked | Yes | 0000000 | 0000000 |
For Use With Surfaces | |||||||||||
-58° to 1472° F/-50° to 800° C | 0.1, 1/0.1, 1 | ±1.8° F/±1° C | 1 | 1 | 5.75 | 6" | 5/16" | CE Marked | Yes | 0000000 | 000000 |
High-Temperature Water-Resistant Hand-Held Thermometers
The thermocouple probe measures temperatures up to 500° F, and the thermometer housing is IP07 rated for protection from temporary submersion.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Environmental Rating | Specifications Met | Batteries Included | Each | |
For Use With Surfaces | ||||||||||||
-100° to 500° F/-73° to 260° C | 0.1, 1/0.1, 1 | -6.3° F to +2.7° F/-3.5° C to +1.5° C | 1 | 2 | 3 | 5 3/4" | 11/16" | IP07 | CE Marked | Yes | 00000000 | 0000000 |
Stainless Steel Replacement Probe | 00000000 | Each | 0000000 |
Remote-Reading Hand-Held Thermometers with Calibration Certificate
A remote probe extends your reach in hard-to-access areas. These thermometers come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy.
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Batteries Included | Each | ||
For Use With Air, Liquids | |||||||||||
A | -58° to 158° F/-50° to 70° C | 0.01/0.01 | ±0.6° F/±0.3° C | 2 | 1 | 5 | 6 1/4" | 1/8" | Yes | 0000000 | 0000000 |
B | -58° to 158° F/-50° to 70° C | 1/1 | ±1.8° F/±1° C | 1 | 10 | 10 | 7/8" | 3/16" | Yes | 0000000 | 00000 |
C | -58° to 302° F/-50° to 150° C | 0.0001, 0.001, 0.01, 0.1/0.0001, 0.001, 0.01, 0.1 | ±0.1° F/±0.05° C | 1 | 0.5 | 5 | 9" | 1/8" | Yes | 0000000 | 000000 |
D | -58° to 302° F/-50° to 150° C | 0.1/0.1 | ±1.8° F/±1.0° C | 1 | 10 | 1.5 | 7" | 1/8" | Yes | 0000000 | 00000 |
Replacement USB-A Probe for Style C (66" Lg.) | 0000000 | Each | 000000 |
Data-Logging Hand-Held Thermometers
Measure and store temperature readings and upload the data to a PC.
Thermometers with a USB output transfer data through your PC’s USB port.
For easy upload, thermometers with an SD memory card store readings in Excel format.
Thermometers | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Replacement Probes | |||||||||||||
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Features | Specifications Met | Batteries Included | Each | Each | ||
For Use With Air, Gases, Surfaces | ||||||||||||||
Thermometers | ||||||||||||||
1 | -22° to 158° F/ -30° to 70° C | 0.1/ 0.1 | ±1° F/ ±0.5° C | 30 | 3 | 3/4" | 3/16" | USB Output, Min./Max. Memory, LED Status Light | CE Marked | Yes | 0000000 | 0000000 | 0000000 | 000000 |
2 | -22° to 572° F/ -30° to 300° C | 0.1/ 0.1 | ±1.75° F/ ±0.90° C | 1.5 | 3 | 1/8" | 3/16" | Auto Power Off, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 |
Thermometers with SD Memory Card | ||||||||||||||
3 | -40° to 482° F/ -40° to 250° C | 0.1/ 0.1 | ±12.86° F/ ±7° C | 1 | 3 | 1/8" | 3/16" | Backlit Display, Built-In Stand, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 |
4 | -40° to 482° F/ -40° to 250° C | 0.1/ 0.1 | ±5.8° F/ ±4.4° C | 1 | 3 | 1/8" | 3/16" | Auto Power Off, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 |
12 | -40° to 482° F/ -40° to 250° C | 0.1/ 0.1 | ±1.8° F/ ±1° C | 1 | 3 | 1/8" | 3/16" | Auto Power Off, Backlit Display, Data Logging Capabilities | CE Marked | Yes | 0000000 | 00000000 | 0000000 | 00000 |
Fluke High-Accuracy Data-Logging Thermometers
Store up to 500 readings on these thermometers and determine temperature within ±0.75° F accuracy.
Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
The optional type K probe (sold separately) connects to your thermometer to measure temperatures up to 537° C or 1000° F.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Manufacturer Part No. | Specifications Met | Batteries Included | Each | |
Thermometers | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 53-2B | CE Marked, CSA Certified | Yes | 00000000 | 0000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 54-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Thermometers with NIST Certificate | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 53-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 54-2B | CE Marked, CSA Certified | Yes | 00000000 | 00000000 |
Optional Type K Probe (8 3/8" Lg.) | 00000000 | Each | 0000000 |
Extended-Life Data-Logging Thermometers
For more accurate and consistent readings than thermometers with thermocouple probes and a longer service life, this thermometer has a resistance temperature detector (RTD) probe. It logs up to 2,000 time- and date-stamped readings and uploads data to a PC through the USB port.
To conserve battery life, use the optional power adapter (sold separately).
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Length, ft. | Lg. | Dia. | Specifications Met | Batteries Included | Each | |
For Use With Air, Gases, Liquids, Solids, Surfaces | |||||||||||
-58° to 932° F/-50° to 500° C | 0.1/0.1 | ±0.1° F/±0.1° C | 1 | 10 | 5 | 4" | 3/16" | CE Marked | Yes | 00000000 | 000000000 |
Fluke High-Accuracy Hand-Held Thermometers
Designed for laboratory applications, these thermometers determine temperature within ±0.75° F accuracy.
Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
The optional type K probe (sold separately) connects to your thermometer to measure temperatures up to 537° C or 1000° F.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Manufacturer Part No. | Specifications Met | Batteries Included | Each | |
Thermometers | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 51-2 | CE Marked, CSA Certified | Yes | 00000000 | 0000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 52-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Thermometers with NIST Certificate | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 51-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 52-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Optional Type K Probe (8 3/8" Lg.) | 00000000 | Each | 0000000 |
Water-Resistant Hand-Held Thermometers
A water-resistant housing and rubberized keypad stand up to washdown conditions and outdoor use. Thermometer includes one immersion probe.
Probe | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Batteries Included | Each | |
For Use With Gases, Liquids | ||||||||||
-100° to 500° F/-73° to 260° C | 1/1 | ±1° F/±0.5° C | 1 | 1 | 3 | 3 1/2" | 3/16" | Yes | 00000000 | 0000000 |
Food and Beverage Hand-Held Thermometers
For use in food-processing applications, this thermometer meets NSF/ANSI standards and includes a thermocouple probe with a pointed tip to pierce dense meats and frozen foods. The housing meets IP07 for protection from temporary submersion.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Environmental Rating | Specifications Met | Batteries Included | Each | |
For Use With Air, Beverage, Food, Liquids, Solids | ||||||||||||
-100° to 500° F/-73° to 260° C | 0.1, 1/0.1, 1 | ±0.9° F/±0.5° C | 1 | 1 | 3 | 4" | 3/16" | IP07 | CE Marked, NSF/ANSI 2 | Yes | 00000000 | 0000000 |
Stainless Steel Replacement Probe | 00000000 | Each | 0000000 |