About Selecting Temperature Sensors
More
Magnetic Thermocouple Probes for Surfaces




Often used where it’d be difficult to mount a standard probe, these probes stick onto magnetic surfaces to take temperature readings. They have a magnet that holds them firmly in place on motors, bearings, and other surfaces. A spring behind the probe protects the cable from strain that could cause it to fray or break. Pick the thermocouple type that best covers the temperature range you expect your surface to be. You should also make sure the thermocouple type you choose is compatible with the devices you plan to connect it to. They’re often used with temperature controllers, thermometers, and other temperature-reading devices.
Probes with wire leads offer more flexibility than probes with connectors already attached because you can either wire them to a terminal block or add your own connector. For installation, note that the red wire is negative.
Spring-loaded probes help keep readings accurate by making sure the tip stays in constant contact with the surface you're measuring. These probes are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
For technical drawings and 3-D models, click on a part number.
Probe | Cable | Wire | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Movement | Response Time, min. | Max. Temp., °F | Accuracy | Sensor Type | Lg., ft. | Material | Max. Temp., °F | Lead Lg. | Gauge | Holding Force, lbs. | Each | |
Type J | ||||||||||||||
Flat-Pin Mini Thermocouple Connector | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | __ | __ | 5 | 0000000 | 0000000 |
Round-Pin Thermocouple Connector | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | __ | __ | 5 | 0000000 | 000000 |
Wire Leads | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | 1/4" | 20 | 5 | 0000000 | 000000 |
1/2" | 1" | Spring Loaded | Not Rated | 1000° | ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 6 | Fiberglass | 1,000° | 1/4" | 24 | 16 | 0000000 | 000000 |
Type K | ||||||||||||||
Flat-Pin Mini Thermocouple Connector | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | __ | __ | 5 | 0000000 | 000000 |
Round-Pin Thermocouple Connector | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | __ | __ | 5 | 0000000 | 000000 |
Wire Leads | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | 1/4" | 20 | 5 | 0000000 | 000000 |
1/2" | 1" | Spring Loaded | Not Rated | 1000° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | Exposed | 6 | Fiberglass | 1,000° | 1/4" | 24 | 16 | 0000000 | 000000 |
Type T | ||||||||||||||
Flat-Pin Mini Thermocouple Connector | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | __ | __ | 5 | 0000000 | 000000 |
Round-Pin Thermocouple Connector | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | __ | __ | 5 | 0000000 | 000000 |
Wire Leads | ||||||||||||||
7/16" | 3/4" | Fixed | 1 | 800° | ±3% below 800° F | Grounded | 2 | FEP Plastic | 500° | 1/4" | 20 | 5 | 0000000 | 000000 |
Hand-Held Magnetic Thermocouple Probes for Surfaces


Measure temperatures around your facility by sticking these probes onto magnetic surfaces. They come attached to a cable that's ready to plug into a handheld thermometer. The handle provides a comfortable grip as you move from spot to spot. It also keeps your hands at a safe distance from hot surfaces as you use the probe. Thanks to their high-strength magnet, they'll stay firmly in place even in high-vibration spots, like on motors and bearings. For accurate readings, a spring pushes the probe tip forward, keeping the tip in constant contact with the surface you're measuring.
Pick the thermocouple type that best covers the temperature range you expect your surface to be. You should also make sure the thermocouple type you choose is compatible with the devices you plan to connect it to.
These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
For technical drawings and 3-D models, click on a part number.
Probe | Material | Cable | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Response Time, sec. | Max. Temp., °F | Accuracy | Magnet | Handle | Shaft | Sensor Type | Lg., ft. | Material | Max. Temp., °F | Holding Force, lbs. | Each | |
Type J | ||||||||||||||
Flat-Pin Mini Thermocouple Connector | ||||||||||||||
1 1/4" | 2" | 4.5 | 1000° | ±4° F between 32° to 533° F ±0.75% above 533° F | Alnico | Phenolic Plastic | 316 Stainless Steel | Ungrounded | 5 | PVC Plastic | 220° | 75 | 0000000 | 0000000 |
Type K | ||||||||||||||
Flat-Pin Mini Thermocouple Connector | ||||||||||||||
1 1/4" | 2" | 4.5 | 1000° | Not Rated below 32° F ±4° F between 32° to 533° F ±0.75% above 533° F | Alnico | Phenolic Plastic | 316 Stainless Steel | Ungrounded | 5 | PVC Plastic | 220° | 75 | 0000000 | 000000 |