Thermocouple Connectors
Simplify connecting your thermocouple to thermometers and control panels—these connectors give your thermocouple a plug-in connection. To attach them to your thermocouple, first remove the panel on these connectors to expose the terminals. Then insert your thermocouple wire leads, tighten the terminals, and reattach the panel.
For technical drawings and 3-D models, click on a part number.
Material | Male | Female | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | For Max. Wire Gauge | Color | Distance Between Pins | Body | Contact | Pin Lg. | Each | Each | ||
Flat-Pin Mini Thermocouple Connector—400° F Max. Temp. | ||||||||||
Screw Terminals | ||||||||||
J | 24 | Black | 0.313" | Plastic | Iron | 1/2" | 0000000 | 00000 | 0000000 | 00000 |
Flat-Pin Mini Thermocouple Connector—800° F Max. Temp. | ||||||||||
Screw Terminals | ||||||||||
J | 24 | Red | 0.313" | Plastic | Iron | 1/2" | 0000000 | 0000 | 0000000 | 0000 |
Round-Pin Thermocouple Connector—400° F Max. Temp. | ||||||||||
Screw Terminals | ||||||||||
J | 14 | Black | 0.438" | Plastic | Iron | 9/16" | 0000000 | 0000 | 0000000 | 0000 |
Round-Pin Thermocouple Connector—800° F Max. Temp. | ||||||||||
Screw Terminals | ||||||||||
J | 14 | Red | 0.438" | Plastic | Iron | 9/16" | 0000000 | 00000 | 0000000 | 00000 |
Quick-Wire Thermocouple Connectors
No need to take these connectors apart to wire them—just insert your wire leads and tighten the terminals to quickly give your thermocouple a plug-in connection. Choose a connector with the same thermocouple type as the thermocouple you’re attaching. You should also make sure the equipment you’re plugging these connectors into is also compatible with the same thermocouple type.
For technical drawings and 3-D models, click on a part number.
Material | Male | Female | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | For Max. Wire Gauge | Color | Distance Between Pins | Body | Contact | Pin Lg. | Each | Each | ||
Round-Pin Thermocouple Connector—400° F Max. Temp. | ||||||||||
Screw Terminals | ||||||||||
J | 14 | Black | 0.438" | Plastic | Iron | 9/16" | 0000000 | 00000 | 0000000 | 00000 |
Round-Pin Thermocouple Connector—800° F Max. Temp. | ||||||||||
Screw Terminals | ||||||||||
J | 14 | Red | 0.438" | Plastic | Iron | 9/16" | 0000000 | 00000 | 0000000 | 00000 |
Round-Pin Thermocouple Connector—1,000° F Max. Temp. | ||||||||||
Screw Terminals | ||||||||||
J | 14 | White | 0.442" | Ceramic | Iron | 1/2" | 0000000 | 00000 | 0000000 | 00000 |
Panel-Mount Thermocouple Connection Strips
Create an easy way to plug in multiple thermocouples—these connection strips mount directly into your control panel. With at least two connections on each strip, you can plug in multiple thermocouples to monitor temperature at different points in your process. Each socket is numbered to help identify thermocouples and keep your wires organized. Choose a connection strip with a thermocouple type that matches the type of thermocouple you’re plugging in. You should also make sure the equipment you’re connecting it to is also compatible with the same thermocouple type.
Connection strips for flat-pin mini thermocouple connectors install from the rear of your panel. They snap into place with spring clips.
Connection strips for round-pin thermocouple connectors install from the front of your panel. Just tighten the screws on the front of the strip and T-nuts will hold it in place against your panel.
Add a mounting frame (sold separately) if your panel opening is larger than the cutout dimensions. When using a mounting frame, install your connection strip into the frame before attaching the entire assembly to your panel opening. Use the frame's mounting holes to secure your fasteners.
For technical drawings and 3-D models, click on a part number.
Connection Strips | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Panel Cutout | Material | Mounting Frames | ||||||||||
Thermocouple Type | No. of Connections | For Max. Wire Gauge | Wd. | Ht. | Color | Body | Contact | Fasteners Included | Each | Each | ||
Female Flat-Pin Mini Thermocouple Connector—400° Max. Temp. | ||||||||||||
Screw Terminals | ||||||||||||
J | 2 | 24 | 1 1/4" | 1" | Black | Plastic | Iron | Yes | 0000000 | 000000 | 0000000 | 000000 |
J | 4 | 24 | 2 5/8" | 1" | Black | Plastic | Iron | Yes | 0000000 | 00000 | 0000000 | 00000 |
J | 6 | 24 | 4" | 1" | Black | Plastic | Iron | Yes | 0000000 | 00000 | 0000000 | 00000 |
J | 8 | 24 | 5 3/8" | 1" | Black | Plastic | Iron | Yes | 0000000 | 00000 | 0000000 | 00000 |
Female Flat-Pin Mini Thermocouple Connector—800° Max. Temp. | ||||||||||||
Screw Terminals | ||||||||||||
J | 2 | 24 | 1 1/4" | 1" | Red | Plastic | Iron | Yes | 00000000 | 00000 | 0000000 | 00000 |
J | 4 | 24 | 2 5/8" | 1" | Red | Plastic | Iron | Yes | 00000000 | 00000 | 0000000 | 00000 |
J | 6 | 24 | 4" | 1" | Red | Plastic | Iron | Yes | 00000000 | 00000 | 0000000 | 00000 |
J | 8 | 24 | 5 3/8" | 1" | Red | Plastic | Iron | Yes | 00000000 | 000000 | 0000000 | 00000 |
Female Round-Pin Thermocouple Connector—400° Max. Temp. | ||||||||||||
Screw Terminals | ||||||||||||
J | 2 | 16 | 1 5/16" | 1 1/4" | Black | Plastic | Iron | Yes | 0000000 | 00000 | 0000000 | 00000 |
J | 4 | 16 | 2 13/16" | 1 1/4" | Black | Plastic | Iron | Yes | 0000000 | 00000 | 0000000 | 00000 |
J | 6 | 16 | 4 5/16" | 1 1/4" | Black | Plastic | Iron | Yes | 0000000 | 00000 | 0000000 | 00000 |
J | 8 | 16 | 5 13/16" | 1 1/4" | Black | Plastic | Iron | Yes | 0000000 | 00000 | 0000000 | 00000 |
J | 10 | 16 | 7 5/16" | 1 1/4" | Black | Plastic | Iron | Yes | 00000000 | 00000 | 0000000 | 00000 |
J | 12 | 16 | 8 13/16" | 1 1/4" | Black | Plastic | Iron | Yes | 00000000 | 000000 | 0000000 | 00000 |
Female Round-Pin Thermocouple Connector—800° Max. Temp. | ||||||||||||
Screw Terminals | ||||||||||||
J | 2 | 16 | 1 5/16" | 1 1/4" | Red | Plastic | Iron | Yes | 00000000 | 00000 | 0000000 | 00000 |
J | 4 | 16 | 2 13/16" | 1 1/4" | Red | Plastic | Iron | Yes | 00000000 | 00000 | 0000000 | 00000 |
J | 6 | 16 | 4 5/16" | 1 1/4" | Red | Plastic | Iron | Yes | 00000000 | 00000 | 0000000 | 00000 |
J | 8 | 16 | 5 13/16" | 1 1/4" | Red | Plastic | Iron | Yes | 00000000 | 000000 | 0000000 | 00000 |
J | 10 | 16 | 7 5/16" | 1 1/4" | Red | Plastic | Iron | Yes | 00000000 | 000000 | 0000000 | 00000 |
J | 12 | 16 | 8 13/16" | 1 1/4" | Red | Plastic | Iron | Yes | 00000000 | 000000 | 0000000 | 00000 |
Panel-Mount Thermocouple Connectors
Create a connection point on a control panel to plug in thermocouples. These connectors can be wired and installed entirely from the front of your panel.
For technical drawings and 3-D models, click on a part number.
Material | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | No. of Connections | For Max. Wire Gauge | For Panel Cutout Dia. | For Knockout Trade Size | Color | Body | Contact | Fasteners Included | Includes | Each | |
Female Flat-Pin Mini Thermocouple Connector—400° F Max. Temp. | |||||||||||
Screw Terminals | |||||||||||
J | 1 | 20 | 7/8", 1 1/8" | 1/2, 3/4 | Black | Plastic | Iron | Yes | Knockout Adapter | 0000000 | 000000 |
Female Flat-Pin Mini Thermocouple Connector—800° F Max. Temp. | |||||||||||
Screw Terminals | |||||||||||
J | 1 | 20 | 7/8", 1 1/8" | 1/2, 3/4 | Red | Plastic | Iron | Yes | Knockout Adapter | 00000000 | 00000 |
Female Round-Pin Thermocouple Connector—400° F Max. Temp. | |||||||||||
Screw Terminals | |||||||||||
J | 1 | 14 | 1 1/8" | 3/4 | Black | Plastic | Iron | Yes | __ | 0000000 | 00000 |
Female Round-Pin Thermocouple Connector—800° F Max. Temp. | |||||||||||
Screw Terminals | |||||||||||
J | 1 | 14 | 1 1/8" | 3/4 | Red | Plastic | Iron | Yes | __ | 00000000 | 00000 |
Female Round-Pin Thermocouple Connector—1,000° F Max. Temp. | |||||||||||
Screw Terminals | |||||||||||
J | 1 | 14 | 1 1/8" | 3/4 | White | Ceramic | Iron | Yes | __ | 00000000 | 00000 |
Thermocouple Connector Adapters
Convert round-pin thermocouple connectors to flat-pin mini thermocouple connectors.
For technical drawings and 3-D models, click on a part number.
Material | ||||||||
---|---|---|---|---|---|---|---|---|
Thermocouple Type | Max. Temperature, ° F | Color | Pin Lg. | Distance Between Pins | Body | Contact | Each | |
Female Round-Pin Thermocouple Connector × Male Flat-Pin Mini Thermocouple Connector | ||||||||
J | 400° | Black | 7/16" | 0.438" | Plastic | Iron | 0000000 | 000000 |
Threaded Thermocouple Connectors
Thread these connectors into a hole for an easy way to plug in a thermocouple. With the wire leads in the back, connect them to controllers, thermometers, and other temperature reading devices.
For technical drawings and 3-D models, click on a part number.
Process | Wire Lead | Material | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | No. of Connections | Temperature Range, °F | Pipe Size | Thread Type | Gender | Gauge | Lg. | Body | Cable | Cable Lg., ft. | Max. Cable Temperature, °F | Each | |
Female Flat-Pin Mini Thermocouple Connector | |||||||||||||
Wire Leads | |||||||||||||
J | 1 | -40° to 390° | 1/2 | NPT | Male | 24 | 2" | Stainless Steel | FEP Plastic | 10 | 400° | 0000000 | 0000000 |
Female Round-Pin Thermocouple Connector | |||||||||||||
Wire Leads | |||||||||||||
J | 1 | -40° to 390° | 3/4 | NPT | Male | 24 | 2" | Stainless Steel | FEP Plastic | 10 | 400° | 0000000 | 000000 |
Conduit-Mount Thermocouple Connection Strips
Already mounted in a conduit box, these connection strips save you the effort of modifying a panel for installation. With six connections on each strip, you can plug in multiple thermocouples to monitor temperature at different points in your process. The sockets are numbered to help you identify thermocouples and keep your wires organized.
To install, remove the connection strip from the conduit box, then pull your wiring through. Attach the box to your conduit, wire up the back of the connection strip, and reattach it to the conduit box. Then just plug your thermocouples into the strip.
For technical drawings and 3-D models, click on a part number.
Body | Material | Conduit Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | No. of Connections | For Max. Wire Gauge | Max. Temperature, °F | Lg. | Wd. | Ht. | Color | Body | Contact | Pipe Size | Thread Type | Gender | Each | |
Female Flat-Pin Mini Thermocouple Connector | ||||||||||||||
Screw Terminals | ||||||||||||||
J | 6 | 24 | 400° | 4 9/16" | 2 13/16" | 2 1/4" | Black | Aluminum | Iron | 3/4 | NPT | Female | 0000000 | 000000 |
Female Round-Pin Thermocouple Connector | ||||||||||||||
Screw Terminals | ||||||||||||||
J | 6 | 20 | 400° | 4 9/16" | 2 13/16" | 2 1/4" | Black | Aluminum | Iron | 3/4 | NPT | Female | 0000000 | 000000 |
Thermocouple Extension Wire with Connectors
Extend the reach of your thermocouple probe—plug-in connectors on both ends of this wire speed up installation.
Coiled wire stays neat and compact for easy storage. You can stretch it out to extend its reach.
Wire | Material | ||||||||
---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, °F | Lg., ft. | Gauge | Dia. | Insulation | Jacket | Max. Jacket Temperature, °F | Each | |
Straight Cable—Solid Wire | |||||||||
Flat-Pin Mini Male × Flat-Pin Mini Female Connector | |||||||||
J | -15° to 220° | 10 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 000000 |
J | -15° to 220° | 25 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
J | -15° to 220° | 50 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
Flat-Pin Mini Male × Flat-Pin Mini Male Connector | |||||||||
J | -15° to 220° | 10 | 24 | 0.17" | PVC | PVC | 220° | 0000000 | 00000 |
J | -15° to 220° | 25 | 24 | 0.17" | PVC | PVC | 220° | 0000000 | 00000 |
Round-Pin Male × Round-Pin Female Connector | |||||||||
J | -15° to 220° | 10 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
J | -15° to 220° | 25 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
J | -15° to 220° | 50 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
Coiled Cable—Stranded Wire | |||||||||
Flat-Pin Mini Male × Flat-Pin Mini Female Connector | |||||||||
J | -30° to 220° | 5 | 28 | 0.165" | PTFE | Polyurethane | 220° | 00000000 | 00000 |
Flat-Pin Mini Male × Flat-Pin Mini Male Connector | |||||||||
J | -30° to 220° | 5 | 28 | 0.165" | PTFE | Polyurethane | 220° | 0000000 | 00000 |
Armored Thermocouple Extension Wire with Connectors
With plug-in connectors on both ends, this wire extends the reach of your thermocouple. It’s protected by a stainless steel armor that also resists corrosion and wear. Made of thermocouple materials, it prevents signal loss.
Choose a wire that matches your thermocouple type. You should also make sure the equipment you're connecting it to is compatible with the same thermocouple type.
For technical drawings and 3-D models, click on a part number.
Wire | Material | ||||||||
---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, °F | Lg., ft. | Gauge | Dia. | Insulation | Jacket | Max. Insulation Temperature, °F | Each | |
Stranded Wire | |||||||||
Male Flat-Pin Mini Thermocouple Connector × Female Flat-Pin Mini Thermocouple Connector | |||||||||
J | 32° to 350° | 5 | 24 | 0.02" | PTFE | Stainless Steel | 350° | 0000000 | 000000 |
J | 32° to 350° | 10 | 24 | 0.02" | PTFE | Stainless Steel | 350° | 0000000 | 00000 |
J | 32° to 350° | 25 | 24 | 0.02" | PTFE | Stainless Steel | 350° | 0000000 | 000000 |
Male Round-Pin Thermocouple Connector × Female Round-Pin Thermocouple Connector | |||||||||
J | 32° to 350° | 5 | 24 | 0.02" | PTFE | Stainless Steel | 350° | 0000000 | 00000 |
J | 32° to 350° | 10 | 24 | 0.02" | PTFE | Stainless Steel | 350° | 0000000 | 00000 |
J | 32° to 350° | 25 | 24 | 0.02" | PTFE | Stainless Steel | 350° | 0000000 | 000000 |
Thermocouple Terminal Blocks
Connect thermocouple wires without soldering or splicing. The terminals on these terminal blocks are made from same materials as thermocouples to ensure no signal is lost. Also known as barrier strips, they shield connections from each other to keep them neat and minimize the chance of short circuits. Choose a terminal block that matches your thermocouple type. You should also make sure the equipment you’re connecting it to is also compatible with the same thermocouple type.
For easy wiring, each end is labeled positive or negative. Mount these terminal blocks to a panel or machine using the mounting holes.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits | For Wire Gauge | Wire Connection Type | Terminal Size | Terminal Ctr.-to-Ctr. | Lg. | Wd. | Ht. | Temp. Range, ° F | Mounting Location | Mounting Fasteners Included | Dia. | No. of | Specifications Met | Each | |
Type J | |||||||||||||||
2 | 16-14 | Screw Terminals | No. 6 | 7/16" | 2 3/8" | 1 5/16" | 1/2" | -55° to 300° | Surface | No | 0.17" | 4 | UL Listed | 0000000 | 000000 |
4 | 16-14 | Screw Terminals | No. 6 | 7/16" | 4 3/4" | 1 5/16" | 1/2" | -55° to 300° | Surface | No | 0.17" | 4 | UL Listed | 0000000 | 00000 |
6 | 16-14 | Screw Terminals | No. 6 | 7/16" | 7 1/8" | 1 5/16" | 1/2" | -55° to 300° | Surface | No | 0.17" | 4 | UL Listed | 0000000 | 00000 |
8 | 16-14 | Screw Terminals | No. 6 | 7/16" | 9 1/2" | 1 5/16" | 1/2" | -55° to 300° | Surface | No | 0.17" | 4 | UL Listed | 0000000 | 00000 |
10 | 16-14 | Screw Terminals | No. 6 | 7/16" | 11 7/8" | 1 5/16" | 1/2" | -55° to 300° | Surface | No | 0.17" | 4 | UL Listed | 0000000 | 00000 |
Thermocouple Spade Terminals
Easily connect thermocouple wire to screw terminals without completely removing the screw. The open end of these spade terminals allows you to loosen the screw and slide them under the screw’s head. They’re made from the same materials as thermocouples to make sure no signal is lost. You'll need to use two terminals per thermocouple, one for each wire. Make sure to match the material of each individual thermocouple wire to the material of the terminal.
Use a crimper (required but not included) to install your wire in the spade terminal.
For technical drawings and 3-D models, click on a part number.
Spade | |||||||||
---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | For Wire Gauge | For Screw Size | For Screw Size Decimal Equivalent | Wd. | Thick. | Max. Temperature, °F | Includes | Each | |
J | 22-18 | No. 6 | 0.138" | 0.3" | 0.03" | 300° | Five Constantan Copper Nickel Terminals, Five Iron Terminals | 0000000 | 000000 |