Line-Voltage Thermostats with Thermowell
Commonly used with line-voltage hydronic heaters, this thermostat senses the temperature of liquids. The thermowell protects the sensor.
Overall | Thermowell | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Thread Type | Pipe Size | Specifications Met | Each | |
For Air Conditioners and Heaters | |||||||||||
120V AC-240V AC | 10 | 100° to 240° | SPDT | 4 1/2" | 2 1/4" | 1 7/8" | NPT | 1/2 | UL Listed | 000000 | 0000000 |
Multi-Speed Line-Voltage Thermostats
Control one- and two-speed line-voltage HVAC systems. Set the thermostat to activate the device’s second speed when the temperature surpasses the setting for the first speed by 3.6° F to 9° F.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Temp. Differential, °F | For Use Outdoors | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
For Air Conditioners and Heaters | |||||||||||||
24V AC-250V AC | 15 | 32° to 140° | SPDT | 6" | 2 3/4" | 3 3/8" | 3.6° to 9° | Yes | Yes | IP65; NEMA 4 | CE Marked | 0000000 | 0000000 |
Line-Voltage Thermostats
Regulate line-voltage HVAC systems.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Mounting Fasteners Included | Specifications Met | Each | |
For Air Conditioners and Heaters | ||||||||||
24V AC-277V AC | 22 | 40° to 90° | SPDT | 4 3/4" | 3" | 1 3/8" | Yes | UL Listed | 0000000 | 0000000 |
Remote-Sensor Line-Voltage Thermostats with Thermowell
Commonly used with line-voltage hydronic heaters, this thermostat senses the temperature of liquids at a distance using the remote sensor. The thermowell protects the sensor.
Overall | Thermowell | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Sensor Cord Lg., ft. | Thread Type | Pipe Size | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Each | |
For Air Conditioners and Heaters | ||||||||||||||
120V AC-240V AC | 10 | 100° to 240° | SPDT | 4 1/2" | 2 1/4" | 1 7/8" | 8 | NPT | 1/2 | No | 1/4" | UL Listed | 000000 | 0000000 |
Remote-Sensor Line-Voltage Thermostats
Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Thermostats work with line-voltage HVAC systems.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Sensor Cord Lg., ft. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Each | ||
For Air Conditioners and Heaters | |||||||||||||
A | 120V AC-277V AC | 22 | -30° to 100° | SPDT | 5" | 2 1/4" | 1 5/8" | 8 | No | 1/8" | UL Listed | 0000000 | 0000000 |
B | 120V AC-277V AC | 22 | 40° to 110° | SPDT | 5 1/2" | 2 1/8" | 2 5/8" | 2 | No | 1/8" | UL Listed | 0000000 | 000000 |
DIN-Rail Mount Remote-Sensor Line-Voltage Thermostats
Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Thermostat works with line-voltage HVAC systems.
Remote-Sensor Hazardous Location Line-Voltage Thermostats
Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present. Thermostats are rated Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Sensor Cord Lg., ft. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | |||||||||||||
120V AC-277V AC | 22 | 20° to 80° | SPDT | 5 7/8" | 3" | 3 1/4" | 6 | No | 3/8" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | 0000000 | 0000000 |
Hazardous Location Line-Voltage Thermostats
Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present. Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | ||||||||||||
24V AC-277V AC | 22 | 50° to 90° | SPDT | 5 3/4" | 6 3/8" | 5 5/8" | No | 1/4" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 | 0000000 | 0000000 |
Washdown Line-Voltage Thermostats
Regulate temperatures in washdown areas for HVAC systems that use direct electrical power, such as air conditioners and heaters. Rated NEMA 4X, these thermostats protect against dirt, washdowns, and corrosion.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Electrical Connection Type | Ht. | Wd. | Dp. | For Use Outdoors | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | ||||||||||||||
120V AC-277V AC | 22 | 40° to 100° | SPDT | Hardwire | 6 7/8" | 3 1/8" | 4" | Yes | No | 5/32" | ETL Listed | NEMA 4X | 0000000 | 0000000 |
Enclosure Thermostats for Multiple Devices
Keep electronics in your enclosure from getting too hot or cold with these thermostats that control two devices at once. Clip them to a DIN rail to install.
Adjustable thermostats allow you to set custom temperatures.
Heating and cooling thermostats control heaters and fans or air conditioners. Thermostats with one actuation point, also known as changeover thermostats, switch between heating and cooling so one device is always running. When the temperature in your enclosure gets hotter than the temperature you set, the thermostat will turn on your fan or air conditioner. It goes back to heating once the temperature is reduced by the temperature difference. So for a thermostat with a temperature difference of 9° F, setting it at 60° F means it will heat the enclosure until it reaches 60° F, switch to cooling until it reaches 51° F, and then switch back to heating.
All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked. They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch on fire and won’t spread the fire by dripping. Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
Temperature | Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Setting, °F | Difference, °F | Tolerance, °F | Voltage | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Adjustable | ||||||||||
32° to 140° | 5.4° | ±1.8° | 24V DC | 2 5/8" | 2" | 1 13/16" | IP20 | CE Marked, UL 94 V-0 | 0000000 | 000000 |
40° to 140° | 7° | ±1.8° | 120V AC | 2 9/16" | 1 5/8" | 1 1/2" | IP20 | CE Marked, CSA Certified, CSA-US Certified, UL 94 V-0 | 0000000 | 00000 |
40° to 140° | 9° | -5.4° to 3.6° | 120V AC | 2 5/8" | 2" | 1 1/2" | IP20 | CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
40° to 140° | 9° | -5.4° to 3.6° | 240V AC | 2 5/8" | 2" | 1 1/2" | IP20 | CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0 | 0000000 | 00000 |
Remote Room-Monitoring Adjustable Thermostats
If ambient air temperature rises above or falls below an actuation point, this thermostat flashes the current temperature reading on the display and shows a “high” or “low” message. To actuate remote-mount buzzers (not included), it has two SPDT (single pole, double throw) relays that can each be set to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed). Switch has a built-in ambient temperature sensor.
12-volt DC power supply (not included) is required.
Remote temperature sensors (not included) let you monitor temperature up to 1,000 feet from the switch. Remote sensors can be used simultaneously with the switch’s built-in ambient temperature sensor for monitoring two areas.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Accuracy | Actuation Points | Voltage | Max. Housing Temp., °F | Housing Material | Ht. | Wd. | Dp. | Display | Digit Ht. | Resolution | Each | |
32° F to 122° F/0° C to 50° C | ±1° C/ ±2.0° F | 4 | 12V DC | 120° | Plastic | 4 3/4" | 6" | 1 1/4" | LCD | 1" | 1 | 0000000 | 0000000 |
Threaded Temperature Switches
Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. These switches have an adjustment dial to set the actuation point. All are SPDT (single pole, double throw). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Threaded Brass Probe—3/8 NPT Male | ||||||||||||
0° to 225° | Single | 15 A @ 125 V AC 15 A @ 250 V AC 20 A @ 480 V AC 2 A @ 30 V DC 500 mA @ 125 V DC | 9/16" | 2 1/8" | 1,897 | 3 5/16" | 3 13/32" | 2 13/16" | NEMA 1 | UL Listed; C-UL Listed; CE Marked | 00000000 | 0000000 |
200° to 425° | Single | 15 A @ 125 V AC 15 A @ 250 V AC 20 A @ 480 V AC 2 A @ 30 V DC 500 mA @ 125 V DC | 9/16" | 2 1/8" | 1,784 | 3 5/16" | 3 13/32" | 2 13/16" | NEMA 1 | UL Listed; C-UL Listed; CE Marked | 00000000 | 000000 |
Washdown Threaded Temperature Switches
Turn heating equipment on or off in washdown environments. To withstand splashing water, corrosive liquid, and dust, these switches have a housing that meets NEMA 4X. The threaded probe installs directly into tanks, pipelines, and other process components. Use the adjustment dial to set actuation points.
Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Probe | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Temp. Accuracy, °F | No. of Actuation Points | Actuation Tolerance | No. of Circuits Controlled | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Threaded Brass Probe—1/2 NPT Male | ||||||||||||||||
0° to 225° | __ | 1 | ±1% | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | 1,897 | 9 3/8" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 0000000 |
0° to 225° | ±5° | 2 | ±1% | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | 1,897 | 7 3/8" | 5 3/32" | 5 1/2" | NEMA 4X | UL Listed; C-UL Listed; CE Marked; FM Approved | 0000000 | 000000 |
200° to 425° | __ | 1 | ±1% | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | 1,784 | 9 3/8" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 000000 |
Hazardous Location Threaded Temperature Switches
Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
Switch with one actuation point has one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Switch with two actuation points has two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | No. of Actuation Points | Actuation Tolerance | No. of Circuits Controlled | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Material | Ht. | Wd. | Dp. | Environmental Rating | Each | |
Threaded Brass Probe—1/2 NPT Male | ||||||||||||||
0° to 225° | 1 | ±1% | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | Brass | 10" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 0000000 | 0000000 |
0° to 225° | 2 | ±1% | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 9/16" | 1 7/8" | Brass | 10" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 0000000 | 00000000 |
Wall-Mount Temperature Switches
(Single Pole, Double Throw)
Switch with Enclosed Housing
Turn heating equipment on or off at a specified temperature. Switches have a probe on a cable for remote temperature readings. Set the actuation point with the adjustment dial.
Switches that control one circuit are single pole, double throw (SPDT). They can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Use packing seals and fittings (sold separately) to seal the probe into threaded tanks and pipes.
Probe | Switches | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Max. Switching Current @ Voltage (Electrical Phase) | Dia. | Lg. | Material | Ht. | Wd. | Dp. | Fasteners Included | Environmental Rating | Each | |
SPDT—1 Circuit Controlled | |||||||||||
Enclosed Housing | |||||||||||
-130° to 120° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 4 1/2" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 0000000 |
0° to 150° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 6 7/8" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 000000 |
50° to 300° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 4 1/2" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 000000 |
150° to 650° | 15 A @ 125 V AC (Single) 15 A @ 250 V AC (Single) 15 A @ 480 V AC (Single) | 3/8" | 3 5/8" | Copper | 3 1/4" | 3 1/2" | 2 13/16" | No | NEMA 1 | 00000000 | 000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Washdown Wall-Mount Temperature Switches
Threaded
Copper Probe
Stainless
Steel Probe
To protect these switches from splashing water, corrosive liquid, and dust, the housing meets NEMA 4X for washdown conditions. Switches turn heating equipment on or off at a specified temperature. All have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
SPDT (Single pole, double throw) switches can be set to turn circuits from off to on (normally open) or from on to off (normally closed). Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male. Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Probe | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Temp. Accuracy | No. of Actuation Points | Electrical Phase | Max. Switching Current | Dia. | Lg. | Wire Connection Type | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
SPDT—1 Circuit Controlled | ||||||||||||||
Threaded Copper Probe—1/2 NPT Male | ||||||||||||||
30° to 250° F | ±3° F | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | Screw Terminals | 8 11/16" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 0000000 |
100° to 400° F | ±4° F | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 1/8" | Screw Terminals | 8 11/16" | 4" | 2 3/8" | NEMA 4X | UL Listed; C-UL Listed; CE Marked | 0000000 | 000000 |
SPDT—2 Circuit Controlled | ||||||||||||||
Unthreaded Stainless Steel Probe | ||||||||||||||
30° to 250° F | ±5° F | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | Screw Terminals | 6 11/16" | 5 5/32" | 5 1/2" | NEMA 4X | UL Listed; C-UL Listed; CE Marked; FM Approved | 0000000 | 000000 |
100° to 400° F | ±8° F | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 1/8" | Screw Terminals | 6 11/16" | 5 5/32" | 5 1/2" | NEMA 4X | UL Listed; C-UL Listed; CE Marked; FM Approved | 0000000 | 000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Hazardous Location Wall-Mount Temperature Switches
Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
Switch with one actuation point has one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
Switch with two actuation points has two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Temp. Accuracy, °F | No. of Actuation Points | Electrical Phase | Max. Switching Current | Dia. | Lg. | Ht. | Wd. | Dp. | Environmental Rating | Includes | Each | |
SPDT—1 Circuit Controlled | |||||||||||||
Threaded Stainless Steel Probe—1/2 NPT Male | |||||||||||||
30° to 250° | ±5° | 1 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | 1/2 × 3/4 NPT Adapter Bushing | 0000000 | 000000000 |
SPDT—2 Circuit Controlled | |||||||||||||
Unthreaded Stainless Steel Probe | |||||||||||||
30° to 250° | ±5° | 2 | Single | 15 A @ 125 V AC 15 A @ 250 V AC 15 A @ 480 V AC | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 NEMA 4X NEMA 7 NEMA 9 | __ | 0000000 | 00000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Surface-Mount Temperature Switches
Often used to control heat cable output, these switches maintain your surface’s temperature by turning equipment on or off when they reach a set temperature. They actuate when the temperature rises to the setpoint and reset when the temperature falls below the reset point. Since they're SPDT (single pole, double throw) switches, they control one circuit and can either be wired to turn one device from on to off (normally closed) or from off to on (normally open). Wire them normally closed to power a heater—when the temperature rises to the setpoint, the heater will turn off until the temperature falls below the reset point. Or wire them normally open to turn on alarms or other devices when the temperature rises above the setpoint. Their setpoint isn’t adjustable, so they’re easy to set up and there’s no risk of unintentional changes.
CSA and CSA-US certified, they meet Canadian and American safety standards.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | SPDT | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Actuation Point, °F | Actuation Tolerance | Approx. Difference Between Setpoint and Reset Point, °F | Max. Switching Current @ Voltage (Electrical Phase) | Ht. | Wd. | No. of | Dia. | Specifications Met | Each | |
Nonadjustable Rising Actuation Point | ||||||||||
47° | ±6° F | 10° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 0000000 |
60° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
75° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
105° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
200° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
Hazardous Location Surface-Mount Temperature Switches
Safe for use in chemical plants, refineries, and other hazardous locations, these switches maintain your surface’s temperature by turning equipment on or off when they reach a set temperature. They’re FM approved for use where flammable gases may be present. These switches actuate when the temperature rises to the setpoint and reset when the temperature falls below the reset point. Since they're SPDT (single pole, double throw) switches, they control one circuit and can either be wired to turn one device from on to off (normally closed) or from off to on (normally open). Wire them normally closed to power a heater—when the temperature rises to the setpoint, the heater will turn off until the temperature falls below the reset point. Or wire them normally open to turn on alarms or other devices when the temperature rises above the setpoint. Their setpoint isn’t adjustable, so they’re easy to set up and there’s no risk of unintentional changes.
CSA-US and CSA certified, they also meet American and Canadian safety standards.
Mounting Holes | SPDT | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Actuation Point, °F | Actuation Tolerance | Approx. Difference Between Setpoint and Reset Point, °F | Max. Switching Current @ Voltage (Electrical Phase) | Ht. | Wd. | No. of | Dia. | Environmental Rating | Specifications Met | Each | |
Nonadjustable Rising Actuation Point | |||||||||||
47° | ±6° F | 10° | 15 A @ 240 V AC (Single) | 2 7/8" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 0000000 |
60° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
75° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
105° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
200° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
Washdown Autotuning Temperature Controllers
The faceplate on these controllers is sealed to meet NEMA 4X and IP66 for protection in washdown environments with splashing water, corrosive liquid, and dust. The rear case meets IP20, which prevents objects about the size of a finger from coming into contact with a live circuit.
Because they have proportional-integral-derivative (PID) software, these controllers are ideal for turning heating equipment on and off in systems with rapid, unpredictable, and complex temperature changes. They help you achieve precise and stable temperature control with fuzzy logic that learns system behavior and automatically compensates for changes. Use the autotuning function to cycle and identify the ideal PID variables for your system to achieve the most precise control. These controllers read temperature with a highly sensitive thermocouple probe (sold separately) in critical process applications. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, and other settings.
Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
Mechanical relay outputs actuate circuits directly. Single pole, single throw (SPST) relays turn one circuit from off to on (normally open). Single pole, double throw (SPDT) relays can be set to turn the circuit from off to on (normally open) or from on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/8 DIN—For 3 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Alarm—Two Mechanical Relays | Heating—SPDT Alarm—SPST-NO | Heating—5 A @ 250 V AC Alarm—1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 0000000 |
1/4 DIN—For 3 3/4" × 3 3/4" Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Alarm—Two Mechanical Relays | Heating—SPDT Alarm—SPST-NO | Heating—3 A @ 250 V AC Alarm—1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
On/Off Temperature Controllers
The simplest temperature controllers—they turn devices fully on or off, with no middle state, at a given temperature. They’re best as alarms and for systems where temperature changes slowly, but they shouldn’t be used when precise temperature control is necessary. All automatically reset as the temperature fluctuates. To read the temperature, they use a highly sensitive thermocouple probe (not included). And their mechanical relay actuates circuits directly. Controllers are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Mount them into cutouts in instrument panels.
All meet American, Canadian, and European safety standards.
Controllers with a dial let you change the temperature actuation point with a turn. They fit into panels with 1/16 DIN cutouts. To mount them to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit these controllers, use DIN cutout adapters.
Controllers with a keypad let you quickly adjust the temperature actuation point, reset point, and other settings.
IP64 rated controllers protect against dust and splashing water.
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/16 DIN—For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | ||||||||||
32° to 1,110° F 0° to 600° C | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | IP40 | 0000000 | 0000000 |
32° to 2,190° F 0° to 1,200° C | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | IP40 | 0000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Temperature Control Range, °F | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Environmental Rating | Each | |
120V AC Input Voltage | |||||||||
For 1 1/8" Ht. × 2 13/16" Wd. Panel Cutout | |||||||||
32° to 990° | J, K, S | 1 | Heating—One Mechanical Relay | SPDT | 16 A @ 240 V AC | Automatic | IP64 | 0000000 | 0000000 |
240V AC Input Voltage | |||||||||
For 1 1/8" Ht. × 2 13/16" Wd. Panel Cutout | |||||||||
32° to 990° | J, K, S | 1 | Heating—One Mechanical Relay | SPDT | 16 A @ 240 V AC | Automatic | IP64 | 0000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | No. of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Washdown On/Off Temperature Controllers
Rated IP65 and NEMA 4X to seal out water and dust, these temperature controllers turn your equipment on and off in areas with frequent washdowns. They're the simplest type of temperature controller, so they switch your heater or other device fully on or off without a middle state when they reach a given temperature. These controllers work great as alarms and in systems that can't handle rapid switching or have slow temperature changes. However, you shouldn't use them in processes that require precise control over temperatures.
To read temperature, these controllers use a highly sensitive thermocouple or RTD probe (not included). Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Since these controllers reset automatically, they turn off and on again as the temperature fluctuates. Use the keypad to set the actuation point, reset point, and other settings. Mount them into instrument panel cutouts.
These controllers have UL recognized components and are CSA certified and CE marked, so they meet American, Canadian, and European safety standards.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 390° F 0° to 200° C | J | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
32° to 2,190° F 0° to 1,200° C | K | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 000000 |
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For RTD Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 1,470° F 0° to 800° C | 100 ohms | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
High-Limit Temperature Controllers
To protect equipment and personnel, these controllers shut down your machine when it gets too hot. Reset them manually to turn your machine on again. They're often used as a fail-safe system and for triggering alarms.
Set the actuation point and adjust other settings with the keypad. To read the temperature, these controllers use a highly sensitive thermocouple probe (sold separately). They have one or two mechanical relays that actuate circuits directly. Mount them into instrumentation panels with DIN cutouts.
Controllers that are SPDT (single pole, double throw) can turn one circuit from off to on (normally open) or on to off (normally closed).
Controllers that are SPST-NO (single pole, single throw) can turn one circuit from off to on (normally open).
Remote-reset controllers are best for hard-to-reach locations. To operate, you’ll need to wire the remote reset input terminals, and the sensor must be below the set temperature.
To mount 1/16 DIN controllers to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit 1/16 DIN controllers, add DIN cutout adapters.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Features | Each | |
1/16 DIN—For 1 3/4" Ht. x 1 3/4" Wd. Panel Cutout | ||||||||||
1 | Heating—One Mechanical Relay | SPDT | 2 A @ 240 V AC | Thermocouple | Manual | 90V AC to 264V AC | IP20, IP30 | Remote Reset | 0000000 | 0000000 |
2 | Heating—Two Mechanical Relays | SPST-NO SPDT | 2 A @ 240 V AC | Thermocouple | Manual | 90V AC to 264V AC | IP20, IP30 | __ | 0000000 | 000000 |
1/4 DIN—For 3 5/8" Ht. x 3 5/8" Wd. Panel Cutout | ||||||||||
2 | Heating—Two Mechanical Relays | SPDT | 2 A @ 240 V AC | Thermocouple | Manual | 90V AC to 250V AC | IP20, IP30 | Remote Reset | 0000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | Number of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Proportional Temperature Controllers
Cycle heaters on and off intermittently to maintain a set temperature in your system. These proportional controllers keep your heater on when your system is below the set temperature, and they turn it off in short cycles when your system nears the set temperature. The short cycles make them more precise and allow less temperature fluctuation than on/off controllers. Use them on electric heaters only—they don't work with valves or solenoids.
Turn the dial on these controllers to choose your set temperature. They use a highly sensitive thermocouple probe (not included) to read temperature. Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Install these controllers into instrument panels with DIN cutouts.
All controllers meet American, Canadian, and European safety standards.
To mount 1/16 DIN controllers to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit 1/16 DIN controllers, add DIN cutout adapters.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Temperature Control Range, °F | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Each | |
1/16 DIN—For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
35° to 390° | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | 0000000 | 0000000 |
35° to 750° | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | 0000000 | 000000 |
35° to 2,190° | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | 0000000 | 000000 |
50° to 850° | J | 1 | Heating—One Mechanical Relay | SPDT | 5 A @ 240 V AC | Automatic | 200V AC to 240V AC | 0000000 | 000000 |
1/4 DIN—For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
50° to 850° | J | 1 | Heating—One Mechanical Relay | SPDT | 5 A @ 240 V AC | Automatic | 90V AC to 264V AC | 0000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | Number of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Heat-Actuated Switches
Open or close a circuit when a fusible link melts. These switches are often used as a safety switch to shut off hydraulic equipment. Mount them to an electrical box indoors.
Replace the fusible link (sold separately) to reset the switch.
Heat-Actuated Switches | Fusible Links | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Fusible Link Melting Temperature | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Maximum Voltage | Each | Each | ||
With Quick-Disconnect Terminals | |||||||||||
135° F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 20 A @ 120 V AC | 120V AC | 000000 | 0000000 | 00000000 | 00000 |
155° F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 20 A @ 120 V AC | 120V AC | 000000 | 000000 | 00000000 | 0000 |
165° F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 20 A @ 120 V AC | 120V AC | 0000000 | 000000 | 0000000 | 0000 |
212° F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 20 A @ 120 V AC | 120V AC | 0000000 | 000000 | 0000000 | 0000 |
280° F | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 20 A @ 120 V AC | 120V AC | 0000000 | 000000 | 0000000 | 0000 |