Multi-Speed Line-Voltage Thermostats

Control one- and two-speed line-voltage HVAC systems. Set the thermostat to activate the device’s second speed when the temperature surpasses the setting for the first speed by 3.6° F to 9° F.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Temp. Differential, °F | For Use Outdoors | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
For Air Conditioners and Heaters | |||||||||||||
24V AC-250V AC | 15 | 32° to 140° | SPDT | 6" | 2 3/4" | 3 3/8" | 3.6° to 9° | Yes | Yes | IP65; NEMA 4 | CE Marked | 0000000 | 0000000 |
Electronic Temperature Switches with Digital Display


Micro
M12 Plug
A digital display makes it easy to monitor the temperature and control when these switches turn heating equipment on and off. They have an adjustable reset, so you can change the temperature range between when they activate and deactivate, commonly referred to as deadband and differential. Use the keypad to adjust the setpoint and reset point anywhere on the setpoint range. They produce an electronic signal that is often used to communicate with a programmable logic controller (PLC), so they're common in control and automation applications. Install them directly into tanks, pipelines, and other process components using their threaded probe.
These switches have a micro M12 plug, so you can quickly connect and disconnect them.
Rated IP65 and IP67, these switches protect against dust and water from washdowns and temporary submersion. They’re also UL listed, C-UL listed, and CE marked, so they meet U.S., Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Approx. Difference Between Setpoint and Reset Point | Temp. Accuracy | Actuation Tolerance | Signal Output Type | Max. Switching Current @ Voltage | Dia. | Lg. | Max. Pressure, psi | Plug Type | Environmental Rating | Specifications Met | Each | |
2 Circuits Controlled—2 Off (Normally Open) or 2 On (Normally Closed) | |||||||||||||
Threaded Stainless Steel Probe—1/4 NPT Male | |||||||||||||
0º to 170° F / -20º to 80° C | Adjustable | ±0.6° F / ±0.9° C | ±0.5% | PNP | 250 mA @ 35 V DC | 1/4" | 1" | 2,100 | 4-Pole Micro M12 | IP65, IP67 | UL Listed; C-UL Listed; CE Marked | 0000000 | 0000000 |
0º to 240° F / -20º to 120° C | Adjustable | ±0.8° F / ±1° C | ±0.5% | PNP | 250 mA @ 35 V DC | 1/4" | 6" | 725 | 4-Pole Micro M12 | IP65, IP67 | UL Listed; C-UL Listed; CE Marked | 0000000 | 000000 |
Washdown On/Off Temperature Controllers

Rated IP65 and NEMA 4X to seal out water and dust, these temperature controllers turn your equipment on and off in areas with frequent washdowns. They're the simplest type of temperature controller, so they switch your heater or other device fully on or off without a middle state when they reach a given temperature. These controllers work great as alarms and in systems that can't handle rapid switching or have slow temperature changes. However, you shouldn't use them in processes that require precise control over temperatures.
To read temperature, these controllers use a highly sensitive thermocouple or RTD probe (not included). Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Since these controllers reset automatically, they turn off and on again as the temperature fluctuates. Use the keypad to set the actuation point, reset point, and other settings. Mount them into instrument panel cutouts.
These controllers have UL recognized components and are CSA certified and CE marked, so they meet American, Canadian, and European safety standards.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 390° F 0° to 200° C | J | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
32° to 2,190° F 0° to 1,200° C | K | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 000000 |
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For RTD Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 1,470° F 0° to 800° C | 100 ohms | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
Electronic Insertion Flow Switches
Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter (sold separately) and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. These switches are accurate in any mounting orientation.
IP65 rated switches protect against dust and washdowns. IP67 rated switches withstand temporary submersion.
For technical drawings and 3-D models, click on a part number.

Set Point Range | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Pipe Size | For Liquids, gpm | For Gases, scfm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Body Ht. | Probe Lg. | Environmental Rating | Specifications Met | Each | |
304 Stainless Steel Body | |||||||||||
One Digital NPN Signal Output | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 19 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 0000000 |
One Digital PNP Signal Output | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 18 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Two Digital NPN Signal Outputs | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 19 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Two Digital PNP Signal Outputs | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 18 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |