Remote-Sensor Hazardous Location Line-Voltage Thermostats
Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present. Thermostats are rated Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Sensor Cord Lg., ft. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | |||||||||||||
120V AC-277V AC | 22 | 20° to 80° | SPDT | 5 7/8" | 3" | 3 1/4" | 6 | No | 3/8" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | 0000000 | 0000000 |
Hazardous Location Line-Voltage Thermostats
Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present. Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Temp. Setting, °F | Switch Type | Ht. | Wd. | Dp. | Mounting Fasteners Included | Mounting Hole Dia. | Specifications Met | Environmental Rating | Each | |
For Air Conditioners and Heaters | ||||||||||||
24V AC-277V AC | 22 | 50° to 90° | SPDT | 5 3/4" | 6 3/8" | 5 5/8" | No | 1/4" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 | 0000000 | 0000000 |
24V AC-277V AC | 22 | 50° to 90° | DPDT | 5 3/4" | 6 3/8" | 5 5/8" | No | 1/4" | UL Listed, CSA Certified | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 | 0000000 | 000000 |
Enclosure Thermostats for Multiple Devices
Keep electronics in your enclosure from getting too hot or cold with these thermostats that control two devices at once. Clip them to a DIN rail to install.
Adjustable thermostats allow you to set custom temperatures.
Heating and cooling thermostats control heaters and fans or air conditioners. Thermostats with one actuation point, also known as changeover thermostats, switch between heating and cooling so one device is always running. When the temperature in your enclosure gets hotter than the temperature you set, the thermostat will turn on your fan or air conditioner. It goes back to heating once the temperature is reduced by the temperature difference. So for a thermostat with a temperature difference of 9° F, setting it at 60° F means it will heat the enclosure until it reaches 60° F, switch to cooling until it reaches 51° F, and then switch back to heating.
Heating and cooling thermostats with two actuation points control two devices independently. When your enclosure temperature is within the set range, neither device is powered, so they’re more efficient than changeover thermostats. For each device, temperature setting is the high end of the temperature range, and temperature difference is the size of the range. For a thermostat with temperature settings of 59° and 95° F and an 18° F temperature difference, the heater will switch on when your enclosure is colder than 41° F and turn off when it reaches 59° F. The fan or other cooling device will switch on when the temperature goes above 95° F and turn off once the enclosure cools to 77° F.
Cooling thermostats regulate two cooling devices, such as a fan and an air conditioner, for two-stage cooling. Use only one device for cooling in mild temperatures or both for extreme heat. These thermostats switch your equipment on when the enclosure is hotter than the temperature setting. Once the temperature is reduced by the temperature difference, it will switch off. For example, a thermostat set at 77° F for a fan and 140° F for an air conditioner will power both devices when the enclosure is over 140° F. With a temperature difference of 18° F, the air conditioner will switch off when the temperature goes below 122° F. The fan will run until the temperature reaches 59° F, and switch back on if it heats up to 77° F or hotter.
All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked. They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch on fire and won’t spread the fire by dripping. Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
Temperature | Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Setting, °F | Difference, °F | Tolerance, °F | Voltage | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Adjustable | ||||||||||
40° to 140° | 7° | ±1.8° | 120V AC | 2 9/16" | 1 5/8" | 1 1/2" | IP20 | CE Marked, CSA Certified, CSA-US Certified, UL 94 V-0 | 0000000 | 000000 |
Heating Temperature | Cooling Temperature | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Setting | Difference | Tolerance | Setting | Difference | Tolerance | Voltage | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Adjustable | |||||||||||||
14° F to 122° F | 12.6° F | ±7° F | 68° F to 176° F | 12.6° F | ±7° F | 120V AC/240V AC | 2 5/8" | 2" | 1 13/16" | IP20 | CSA Certified, CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0, VDE Certified | 0000000 | 000000 |
32° F to 140° F | 12.6° F | ±7° F | 32° F to 140° F | 12.6° F | ±7° F | 120V AC/240V AC | 2 5/8" | 2" | 1 13/16" | IP20 | CSA Certified, CE Marked, UL Recognized Component, C-UL Recognized Component, UL 94 V-0, VDE Certified | 0000000 | 00000 |
Cooling Temperature | Cooling Temperature | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Setting | Difference | Tolerance | Setting | Difference | Tolerance | Voltage | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
Adjustable | |||||||||||||
32° F to 140° F | 12.6° F | ±7° F | 32° F to 140° F | 12.6° F | ±7° F | 120V AC/240V AC | 2 5/8" | 2" | 1 13/16" | IP20 | CSA Certified, CE Marked, VDE Certified, C-UL Recognized Component, UL 94 V-0, UL Recognized Component | 0000000 | 000000 |
Enclosure Thermostats
Control a single heating or cooling device in your enclosure to keep electronics at a safe operating temperature. Clip them on to a DIN rail and connect them to your heater, fan, or air conditioner.
All these thermostats meet American, Canadian, or European safety standards. They have an IP20 rating—to prevent shocks, fingers won’t fit inside. They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
Adjustable thermostats let you set the temperature you need.
These thermostats keep the air in your enclosure within a set range. Temperature setting is the high end of the range for both heating and cooling thermostats. Heating thermostats are normally closed—when the air in your enclosure reaches the temperature setting, the thermostat will turn the heater off. Cooling thermostats are normally open, so they’ll switch your fan or air conditioner on when the air in your enclosure reaches the temperature setting.
Temperature difference is the difference between the temperature when the thermostat turns your device on and when it turns off. For a heater thermostat with a temperature setting of 50° and an 18° temperature difference, the thermostat will switch your heater on when the temperature goes below 32° and off once the temperature reaches 50°. Thermostats with a lower temperature difference maintain a narrower range of temperatures, but they use more power because they switch on and off more frequently.
For technical drawings and 3-D models, click on a part number.
Temperature | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Setting | Difference | Tolerance | Voltage | Current, A | For DIN Rail Ht., mm | Ht. | Wd. | Dp. | Environmental Rating | Specifications Met | Each | |
For Cooling | ||||||||||||
Adjustable | ||||||||||||
14° to 122° F | 12.6° F | ±7° F | 120V AC/240V AC | 16 | 35 | 2.4" | 1.3" | 1.6" | IP20 | CE Marked, CSA Certified, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 0000000 | 000000 |
32° to 140° F | 12.6° F | ±7° F | 120V AC/240V AC | 16 | 35 | 2.4" | 1.3" | 1.6" | IP20 | CE Marked, CSA Certified, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 00000000 | 00000 |
For Heating | ||||||||||||
Adjustable | ||||||||||||
14° to 122° F | 12.6° F | ±7° F | 120V AC/240V AC | 16 | 35 | 2.4" | 1.3" | 1.6" | IP20 | CE Marked, CSA Certified, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 0000000 | 00000 |
32° to 140° F | 12.6° F | ±7° F | 120V AC/240V AC | 16 | 35 | 2.4" | 1.3" | 1.6" | IP20 | CE Marked, CSA Certified, UL 94 V-0, UL Recognized Component, C-UL Recognized Component, VDE Certified | 000000 | 00000 |
Snap-Action Thermostats
Also known as snap discs, these thermostats switch on cooling systems or switch off heating systems when equipment gets too hot. Each thermostat has five temperature options for switch activation; choose the one that best suits your application.
Unlike heat-actuated switches, these thermostats reset automatically, saving you the effort of replacing a melted fusible link. To calculate their reset temperature, subtract their differential temperature from the temperature you set them at. For example, a thermostat set at 100° F with a 20° F differential will reset at 80° F.
Normally open thermostats are also known as low-limit thermostats—they turn on at a set temperature. They’re good for use with fans and blowers.
Normally closed thermostats are also known as high-limit thermostats—they turn off at a set temperature. They’re often used with electric water heaters, stoves, and furnaces.
Overall | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Setting | Temperature Differential | Switch Type | Switch Starting Position | Voltage | Current | Wire Connection Type | Terminal Size | Face Dia. | Ht. | Wd. | Dp. | Hole Dia. (No. of) | Fasteners Included | Each | |
Close at Temperature Setting | |||||||||||||||
90° F, 100° F, 110° F, 120° F, 130° F | 20° F | SPST | 1 Off (Normally Open) | 120V AC/240V AC | 25A | Quick-Disconnect Terminals | 1/4" | 3/4" | 1 3/4" | 2" | 1 3/8" | 3/16" (2) | No | 0000000 | 000000 |
140° F, 150° F, 160° F, 170° F, 180° F | 20° F | SPST | 1 Off (Normally Open) | 120V AC/240V AC | 25A | Quick-Disconnect Terminals | 1/4" | 3/4" | 1 3/4" | 2" | 1 3/8" | 3/16" (2) | No | 0000000 | 00000 |
Open at Temperature Setting | |||||||||||||||
135° F, 145° F, 155° F, 165° F, 175° F | 20° F | SPST | 1 On (Normally Closed) | 120V AC/240V AC | 25A | Quick-Disconnect Terminals | 1/4" | 3/4" | 1 3/4" | 2" | 1 3/8" | 3/16" (2) | No | 0000000 | 00000 |
135° F, 145° F, 155° F, 165° F, 175° F | 40° F | SPST | 1 On (Normally Closed) | 120V AC/240V AC | 25A | Quick-Disconnect Terminals | 1/4" | 3/4" | 1 3/4" | 2" | 1 3/8" | 3/16" (2) | No | 0000000 | 00000 |
175° F, 185° F, 195° F, 205° F, 215° F | 40° F | SPST | 1 On (Normally Closed) | 120V AC/240V AC | 25A | Quick-Disconnect Terminals | 1/4" | 3/4" | 1 3/4" | 2" | 1 3/8" | 3/16" (2) | No | 0000000 | 00000 |
210° F, 220° F, 230° F, 240° F, 250° F | 40° F | SPST | 1 On (Normally Closed) | 120V AC/240V AC | 25A | Quick-Disconnect Terminals | 1/4" | 3/4" | 1 3/4" | 2" | 1 3/8" | 3/16" (2) | No | 0000000 | 00000 |
250° F, 260° F, 270° F, 280° F, 290° F | 40° F | SPST | 1 On (Normally Closed) | 120V AC/240V AC | 25A | Quick-Disconnect Terminals | 1/4" | 3/4" | 1 3/4" | 2" | 1 3/8" | 3/16" (2) | No | 0000000 | 00000 |
Ceiling Fan Speed Controls
Convert one or more single-speed ceiling fans to variable speed.
Controls with a switch can be turned on and off without adjusting the speed, reducing wear on the motor. Unlike knob-only controls, you can use use the switch to quickly start and stop fans without changing your settings.
Connect knob-only and slide bar/switch controls in a single-gang switch box.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Max. Current, A | Voltage | Electrical Connection Type | Material | Color | Ht. | Wd. | Specifications Met | Mounting Fasteners Included | Each | |
Knob Control | ||||||||||
2.5 | 120V AC | Hardwire | Aluminum | Silver | 4 1/2" | 2 7/8" | CSA Certified, UL Listed | Yes | 0000000 | 000000 |
5 | 120V AC | Hardwire | Aluminum | Silver | 4 1/2" | 2 7/8" | CSA Certified, UL Listed | Yes | 0000000 | 00000 |
10 | 120V AC | Hardwire | Aluminum | Silver | 4 1/4" | 4 1/4" | CSA Certified, UL Listed | Yes | 0000000 | 00000 |
15 | 120V AC | Hardwire | Aluminum | Silver | 4 1/4" | 4 1/4" | CSA Certified, UL Listed | Yes | 0000000 | 000000 |
Slide Bar/Switch Control | ||||||||||
5 | 120V AC | Hardwire | Plastic | White | 4 1/8" | 2 1/8" | CSA Certified, UL Listed | Yes | 0000000 | 000000 |
Compact Threaded Temperature Switches
Since these switches don’t have a housing above the probe, they are often used in tight spaces and low-clearance areas. The threaded probe installs directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Use the adjustment screw to set the actuation point. All switches are SPST (single pole, single throw) and control one circuit.
Normally open switches turn the circuit from off to on.
Normally closed switches turn the circuit from on to off.
For technical drawings and 3-D models, click on a part number.
Probe | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Temp. Range, °F | Actuation Tolerance | Electrical Phase | Max. Switching Current @ Voltage | Dia. | Lg. | Material | Insulation Material | Each | |
1 Off (Normally Open) | ||||||||||
NPT Male Threaded | ||||||||||
1/2 | -100° to 600° | ±2% | Single | 10 A @ 120 V AC 5 A @ 240 V AC 2 A @ 120 V DC | 5/8" | 3" | Stainless Steel | Fiberglass | 0000000 | 0000000 |
NPT Male × NPT Male Threaded | ||||||||||
1/2 × 1/2 | -100° to 600° | ±2% | Single | 10 A @ 120 V AC 5 A @ 240 V AC 2 A @ 120 V DC | 5/8" | 3" | Stainless Steel | Fiberglass | 0000000 | 000000 |
1 On (Normally Closed) | ||||||||||
NPT Male Threaded | ||||||||||
1/2 | -100° to 600° | ±2% | Single | 10 A @ 120 V AC 5 A @ 240 V AC 2 A @ 120 V DC | 5/8" | 3" | Stainless Steel | Fiberglass | 0000000 | 000000 |
NPT Male × NPT Male Threaded | ||||||||||
1/2 × 1/2 | -100° to 600° | ±2% | Single | 10 A @ 120 V AC 5 A @ 240 V AC 2 A @ 120 V DC | 5/8" | 3" | Stainless Steel | Fiberglass | 0000000 | 000000 |
Wall-Mount Temperature Switches
(Double Pole, Single Throw)
Switch with Enclosed Housing
Turn heating equipment on or off at a specified temperature. Switches have a probe on a cable for remote temperature readings. Set the actuation point with the adjustment dial.
Switches that control two circuits are double pole, single throw (DPST). They turn two circuits from on to off (normally closed).
Switches with an open housing are often added to existing enclosures or custom installations.
Switches with a pilot light indicate when the switch is on.
Use packing seals and fittings (sold separately) to seal the probe into threaded tanks and pipes.
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Max. Switching Current @ Voltage (Electrical Phase) | Dia. | Lg. | Material | Ht. | Wd. | Dp. | Fasteners Included | Environmental Rating | Each | |
Switches | |||||||||||
DPST—2 Circuit Controlled | |||||||||||
Open Housing | |||||||||||
60° to 250° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 1/4" | 5 5/32" | Copper | 4 1/16" | 2 5/8" | 3 1/16" | No | __ | 0000000 | 0000000 |
200° to 550° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 5/16" | 4 1/2" | Copper | 4 1/16" | 2 5/8" | 3 1/16" | No | __ | 0000000 | 000000 |
Enclosed Housing | |||||||||||
0° to 100° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 3/8" | 4 3/16" | Copper | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
60° to 250° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 1/4" | 5 5/32" | Copper | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
200° to 550° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 5/16" | 4 7/8" | Copper | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
300° to 700° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 3/16" | 13" | Nickel | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
Switches with Pilot Light | |||||||||||
DPST—2 Circuit Controlled | |||||||||||
Open Housing | |||||||||||
60° to 250° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 1/4" | 5 5/32" | Copper | 4 1/16" | 2 5/8" | 3 1/16" | No | __ | 0000000 | 000000 |
200° to 550° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 5/16" | 4 1/2" | Copper | 4 1/16" | 2 5/8" | 3 1/16" | No | __ | 0000000 | 000000 |
Enclosed Housing | |||||||||||
0° to 100° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 3/8" | 4 3/16" | Copper | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
60° to 250° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 1/4" | 5 5/32" | Copper | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
200° to 550° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 5/16" | 4 7/8" | Copper | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
300° to 700° | 30 A @ 120 V AC (Single) 30 A @ 277 V AC (Three) | 3/16" | 13" | Nickel | 5 3/4" | 3" | 3 1/8" | No | NEMA 1 | 0000000 | 000000 |
Packing Seals and Fittings | 0000000 | Each | 000000 |
Hazardous Location Surface-Mount Temperature Switches
Safe for use in chemical plants, refineries, and other hazardous locations, these switches maintain your surface’s temperature by turning equipment on or off when they reach a set temperature. They’re FM approved for use where flammable gases may be present. These switches actuate when the temperature rises to the setpoint and reset when the temperature falls below the reset point. Since they're SPDT (single pole, double throw) switches, they control one circuit and can either be wired to turn one device from on to off (normally closed) or from off to on (normally open). Wire them normally closed to power a heater—when the temperature rises to the setpoint, the heater will turn off until the temperature falls below the reset point. Or wire them normally open to turn on alarms or other devices when the temperature rises above the setpoint. Their setpoint isn’t adjustable, so they’re easy to set up and there’s no risk of unintentional changes.
CSA-US and CSA certified, they also meet American and Canadian safety standards.
Mounting Holes | SPDT | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Actuation Point, °F | Actuation Tolerance | Approx. Difference Between Setpoint and Reset Point, °F | Max. Switching Current @ Voltage (Electrical Phase) | Ht. | Wd. | No. of | Dia. | Environmental Rating | Specifications Met | Each | |
Nonadjustable Rising Actuation Point | |||||||||||
47° | ±6° F | 10° | 15 A @ 240 V AC (Single) | 2 7/8" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 0000000 |
60° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
75° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
105° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
200° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 2 15/16" | 2" | 2 | 11/64" | NEC Class I Division 2 Groups A, B, C, D | CSA-US Certified, CSA Certified, FM Approved | 0000000 | 000000 |
Surface-Mount Temperature Switches
Often used to control heat cable output, these switches maintain your surface’s temperature by turning equipment on or off when they reach a set temperature. They actuate when the temperature rises to the setpoint and reset when the temperature falls below the reset point. Since they're SPDT (single pole, double throw) switches, they control one circuit and can either be wired to turn one device from on to off (normally closed) or from off to on (normally open). Wire them normally closed to power a heater—when the temperature rises to the setpoint, the heater will turn off until the temperature falls below the reset point. Or wire them normally open to turn on alarms or other devices when the temperature rises above the setpoint. Their setpoint isn’t adjustable, so they’re easy to set up and there’s no risk of unintentional changes.
CSA and CSA-US certified, they meet Canadian and American safety standards.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | SPDT | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Actuation Point, °F | Actuation Tolerance | Approx. Difference Between Setpoint and Reset Point, °F | Max. Switching Current @ Voltage (Electrical Phase) | Ht. | Wd. | No. of | Dia. | Specifications Met | Each | |
Nonadjustable Rising Actuation Point | ||||||||||
47° | ±6° F | 10° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 0000000 |
60° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
75° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
105° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
200° | ±6° F | 15° | 15 A @ 240 V AC (Single) | 1 1/8" | 2" | 2 | 3/16" | CSA Certified, CSA-US Certified | 0000000 | 000000 |
Insertion Temperature Switches
Install the probe directly into drilled and reamed holes to turn heating equipment on or off at a specified temperature. Use the adjustment screw to set the actuation point. All switches are SPST (single pole, single throw) and control one circuit.
Normally open switches turn the circuit from off to on.
Normally closed switches turn the circuit from on to off.
For technical drawings and 3-D models, click on a part number.
Probe | Material | ||||||||
---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Temp. Range, °F | Actuation Tolerance | Max. Switching Current | Electrical Phase | Insulation | Probe | Each | |
1 Off (Normally Open) | |||||||||
3 5/8" | 5/8" | -100° to 600° | ±2% | 10 A @ 120 V AC 5 A @ 240 V AC 2 A @ 120 V DC | Single | Fiberglass | Stainless Steel | 0000000 | 000000 |
1 On (Normally Closed) | |||||||||
3 5/8" | 5/8" | -100° to 600° | ±2% | 10 A @ 120 V AC 5 A @ 240 V AC 2 A @ 120 V DC | Single | Fiberglass | Stainless Steel | 0000000 | 00000 |
Washdown Autotuning Temperature Controllers
The faceplate on these controllers is sealed to meet NEMA 4X and IP66 for protection in washdown environments with splashing water, corrosive liquid, and dust. The rear case meets IP20, which prevents objects about the size of a finger from coming into contact with a live circuit.
Because they have proportional-integral-derivative (PID) software, these controllers are ideal for turning heating equipment on and off in systems with rapid, unpredictable, and complex temperature changes. They help you achieve precise and stable temperature control with fuzzy logic that learns system behavior and automatically compensates for changes. Use the autotuning function to cycle and identify the ideal PID variables for your system to achieve the most precise control. These controllers read temperature with a highly sensitive thermocouple probe (sold separately) in critical process applications. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, and other settings.
Controllers with automatic reset switch off and on again automatically as the temperature fluctuates. Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
Mechanical relay outputs actuate circuits directly. Single pole, single throw (SPST) relays turn one circuit from off to on (normally open). Solid state relay outputs send a pulse signal to directly control an external solid-state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays.
Analog signal outputs send 4-20 mA current to actuate equipment on a current loop. They are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
DIN-rail/surface-mount adapters (sold separately) mount 1/16 DIN controllers to a surface.
DIN cutout adapters (sold separately) convert larger cutouts to fit 1/16 DIN controllers.
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN—For 7/8" × 1 3/4" Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | Heating—SPST-NO | Heating—3 A @ 220 V AC | Thermocouple | Automatic | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 0000000 |
1/16 DIN—For 1 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Alarm—Two Mechanical Relays | Heating—SPST-NO Alarm—SPST-NO | Heating—3 A @ 250 V AC Alarm—1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN—For 7/8" × 1 3/4" Panel Cutout | |||||||||
1 | Heating—One 15V DC Solid State Relay Drive | __ | __ | Thermocouple | Automatic | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 0000000 |
1/16 DIN—For 1 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One 12V DC Solid State Relay Drive Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/16 DIN—For 1 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 0000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | No. of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
On/Off Temperature Controllers
The simplest temperature controllers—they turn devices fully on or off, with no middle state, at a given temperature. They’re best as alarms and for systems where temperature changes slowly, but they shouldn’t be used when precise temperature control is necessary. All automatically reset as the temperature fluctuates. To read the temperature, they use a highly sensitive thermocouple probe (not included). And their mechanical relay actuates circuits directly. Controllers are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Mount them into cutouts in instrument panels.
All meet American, Canadian, and European safety standards.
Controllers with a dial let you change the temperature actuation point with a turn. They fit into panels with 1/16 DIN cutouts. To mount them to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit these controllers, use DIN cutout adapters.
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/16 DIN—For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | ||||||||||
32° to 1,110° F 0° to 600° C | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | IP40 | 0000000 | 0000000 |
32° to 2,190° F 0° to 1,200° C | K | 1 | Heating—One Mechanical Relay | SPDT | 3 A @ 250 V AC | Automatic | 100V AC to 240V AC | IP40 | 0000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | No. of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Washdown On/Off Temperature Controllers
Rated IP65 and NEMA 4X to seal out water and dust, these temperature controllers turn your equipment on and off in areas with frequent washdowns. They're the simplest type of temperature controller, so they switch your heater or other device fully on or off without a middle state when they reach a given temperature. These controllers work great as alarms and in systems that can't handle rapid switching or have slow temperature changes. However, you shouldn't use them in processes that require precise control over temperatures.
To read temperature, these controllers use a highly sensitive thermocouple or RTD probe (not included). Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Since these controllers reset automatically, they turn off and on again as the temperature fluctuates. Use the keypad to set the actuation point, reset point, and other settings. Mount them into instrument panel cutouts.
These controllers have UL recognized components and are CSA certified and CE marked, so they meet American, Canadian, and European safety standards.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 390° F 0° to 200° C | J | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
32° to 2,190° F 0° to 1,200° C | K | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 000000 |
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For RTD Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 1,470° F 0° to 800° C | 100 ohms | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
High-Limit Temperature Controllers
To protect equipment and personnel, these controllers shut down your machine when it gets too hot. Reset them manually to turn your machine on again. They're often used as a fail-safe system and for triggering alarms.
Set the actuation point and adjust other settings with the keypad. To read the temperature, these controllers use a highly sensitive thermocouple probe (sold separately). They have one or two mechanical relays that actuate circuits directly. Mount them into instrumentation panels with DIN cutouts.
Controllers that are SPDT (single pole, double throw) can turn one circuit from off to on (normally open) or on to off (normally closed).
Controllers that are SPST-NO (single pole, single throw) can turn one circuit from off to on (normally open).
To mount 1/16 DIN controllers to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit 1/16 DIN controllers, add DIN cutout adapters.
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/16 DIN—For 1 3/4" Ht. x 1 3/4" Wd. Panel Cutout | |||||||||
2 | Heating—Two Mechanical Relays | SPST-NO SPDT | 2 A @ 240 V AC | Thermocouple | Manual | 90V AC to 264V AC | IP20, IP30 | 0000000 | 0000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | Number of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |