About Motor Switches and Starters
More
Choosing an Electrical Switch
More
Enclosure Motor Switches
Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Ht. | Wd. | For DIN Rail Ht., mm | Mounting Dp. | Wire Connection Type | Environmental Rating | Each | |
Stays Switched (Maintained) | |||||||||||||
32 | 600V AC | 3 | Single (2 hp @ 240 V AC) Single (5 hp @ 480 V AC) Three (5 hp @ 240 V AC) Three (10 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 2.4" | 2.4" | 35 | 7 7/8"-14 5/8" | Screw Terminals | IP65 | 0000000 | 0000000 |
Panel-Mount Compact Disconnect Switches
Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included). They’re rated IP65 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 000000000 | 0000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 000000000 | 000000 |
Yellow Plastic Housing with Red Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 00000000 | 000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 00000000 | 000000 |
Enclosed Compact Disconnect Switches
Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Their polycarbonate housing protects the switch and resists denting, chipping, and cracking. Rated IP65, the housing also seals out water even in frequently washed down areas. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout, so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Yellow Plastic Housing with Red Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout | ||||||||
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 0000000 |
4 Circuits with Lockout | ||||||||
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
Panel-Mount Disconnect Switches
Install these switches in a panel cutout. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All are UL listed, C-UL listed, and CE marked—they meet American, Canadian, and European safety standards.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
Terminal covers prevent contact with live terminals.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Environmental Rating | Each | |
Yellow Plastic Housing with Red Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 000000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
Gray Plastic Housing with Gray Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 00000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
For Current, A | Specifications Met | Each | |
25/32 | UL Listed, CE Marked | 00000000 | 000000 |
Enclosed Disconnect Switches
Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Photovoltaic switches can be used with photovoltaic cells which convert sunlight into electricity.
For technical drawings and 3-D models, click on a part number.
Switching | Plastic Housing with Red Actuator | ||||||
---|---|---|---|---|---|---|---|
Current, A | Voltage | Industry Designation | Ht. | Wd. | Environmental Rating | Each | |
Stays Switched (Maintained) | |||||||
2 Circuits with Lockout/Photovoltaic | |||||||
32 | 800V DC | DPST | 11" | 7 1/2" | IP66, IP67, NEMA 3S, NEMA 6P, NEMA 12 | 0000000 | 0000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
Washdown Enclosed Disconnect Switches
The IP66 rated housing not only shields these switches from washdowns but also makes them durable enough to be mounted outside of an electrical panel. These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||
---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Each | |
Plastic Housing with Red Actuator | ||||||||
3 Circuits | ||||||||
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 0000000 |
3 Circuits with Lockout | ||||||||
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
Plastic Housing with Gray Actuator | ||||||||
3 Circuits | ||||||||
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
For Switching Current | Housing Color | Actuator Color | Ht. | Wd. | Dp. | Each | |
25A, 32A, 50A, 63A | Yellow | Red | 2 9/16" | 2 9/16" | 1 5/16" | 0000000 | 000000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
For Current, A | Specifications Met | Each | |
25/32 | UL Listed, CE Marked | 00000000 | 000000 |
Enclosure Disconnect Switches
Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position. Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail. UL listed, C-UL listed, and CE marked, these switches meet American, Canadian, and European safety standards.
Use optional sealing gaskets in washdown environments; they create an IP65 rated seal around the actuator.
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.
Switching | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Electrical Phase (hp) | Ht. | Wd. | For DIN Rail Ht., mm | Mounting Dp. | Environmental Rating | Each | |
Yellow Plastic Housing with Red Actuator | |||||||||
3 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 000000 |
4 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 000000 |
Gray Plastic Housing with Gray Actuator | |||||||||
3 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 |
For Switching Voltage, A | Each | |
25-63 | 0000000 | 00000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
For Current, A | Specifications Met | Each | |
25/32 | UL Listed, CE Marked | 00000000 | 000000 |
DIN-Rail Mount Disconnect Switches
Often used in electrical enclosures, these switches mount directly to DIN rails. They cut power and keep it isolated to stop equipment from starting up during inspection and maintenance. For an extra level of security, add a padlock (not included) to lock out the actuator lever in the Off position.
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control additional circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | For Max. Padlock Shackle Dia. | For DIN Rail Ht., mm | Wire Connection Type | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||||||
3 Circuits with Lockout | ||||||||||||
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
4 Circuits with Lockout | ||||||||||||
32 | 600V AC | Stays Switched (Maintained) | 4PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
32 | UL Listed, CE Marked | 00000000 | 000000 |
For Current, A | Specifications Met | Each | |
25/32 | UL Listed, CE Marked | 00000000 | 000000 |
DIN-Rail Mount Touch-Safe Screw Terminal Relays
Quickly and safely mount these relays on 35 mm DIN rail (also known as DIN 3). IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits.
Relays that control 3 and 4 circuits are built to IEC dimensional standards and are often called IEC contactors.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay. You can add one auxiliary contact to all of these relays. For relays with 12 terminals, you can add two side-mount auxiliary contacts.
For technical drawings and 3-D models, click on a part number.
Control | hp @ Switching Voltage | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Power | Switching Current @ Voltage (Load Type) | Max. Switching Voltage | Single Phase | Three Phase | Ht. | Wd. | Dp. | Each | |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||
With 1 Auxiliary Contact—1 Off (Normally Open) | |||||||||||
12 | 24V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 24V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 120V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 240V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 24V DC | 5.4W | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |
12 | 24V DC | 5.4W | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |
With 1 Auxiliary Contact—1 On (Normally Closed) | |||||||||||
12 | 24V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 24V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 120V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 120V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 240V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 00000 |
12 | 240V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 24V DC | 5.4W | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |
12 | 24V DC | 5.4W | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | |||||||||||
12 | 24V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 24V AC | 6.5VA | 32 A @ 600 V AC (Full Load) 55 A @ 600 V AC (Resistive Load) | 600 V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 30 hp @ 600 V AC | 3.5" | 2.4" | 3.5" | 000000000 | 000000 |
12 | 120V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 120V AC | 6.5VA | 32 A @ 600 V AC (Full Load) 55 A @ 600 V AC (Resistive Load) | 600 V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 30 hp @ 600 V AC | 3.5" | 2.4" | 3.5" | 000000000 | 000000 |
12 | 240V AC | 6.5VA | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 000000000 | 000000 |
12 | 240V AC | 6.5VA | 32 A @ 600 V AC (Full Load) 55 A @ 600 V AC (Resistive Load) | 600 V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 30 hp @ 600 V AC | 3.5" | 2.4" | 3.5" | 000000000 | 000000 |
12 | 24V DC | 5.4W | 17 A @ 600 V AC (Full Load) 32 A @ 600 V AC (Resistive Load) | 600 V AC | 1 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 00000000 | 000000 |
12 | 24V DC | 5.4W | 32 A @ 600 V AC (Full Load) 55 A @ 600 V AC (Resistive Load) | 600 V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 30 hp @ 600 V AC | 3.5" | 2.4" | 4.2" | 00000000 | 000000 |
Touch-Safe DIN-Rail Mount Infrequent-Cycle Relays
Operate equipment that cycles on and off from your control cabinet. Often called definite-purpose contactors, these relays meet UL 508 for use with air conditioning and heating. They mount directly to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. These relays have recessed terminals that prevent fingers and other objects from touching live circuits.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay.
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Max. Switching Voltage | Single Phase | Three Phase | Ht. | Wd. | Dp. | Each | |
Relays | ||||||||||||
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 000000 |
12 | 120V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 240V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
Relays with 1 Off (Normally Open) Auxiliary Contact | ||||||||||||
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 120V AC | 6.5VA | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.2" | 00000000 | 00000 |
12 | 24V DC | 5.4W | 30A | 32A | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 7 1/2 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 3.2" | 1.8" | 3.9" | 0000000 | 000000 |