10 mm Panel-Mount Push-Button Switches
Install in 10 mm dia. cutouts. Simple to use, these switches actuate with a quick push. Color code your switches by choosing a different actuator color for each.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | Choose an Actuator Color | Each | |
Plastic with Solder Lugs | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | 3 | SPDT | 5 A @ 125 V AC, 3 A @ 250 V AC | 250V AC | 1/2" | 13/16" | 0000000 | 000000 |
Cam Panel-Mount Lever Switches
Thanks to their ability to handle higher current than switches with contact blocks, these switches are often found in applications from large motors to warehouse lighting systems. The cam pushes contacts more tightly together than contact blocks, allowing more electricity to flow through. However, they aren’t made to be rewired like switches with contact blocks are. These switches require you to grip and twist a lever to turn circuits on or off, so they won’t accidentally actuate if you bump into them. Mount them in a standard panel cutout diameter.
Choose a switch based on the complexity of your application. On/off switches have two positions. Changeover switches have three positions. They work well if you need to toggle between a primary power source and a backup generator. Selector switches have up to six positions. They give you the most control, allowing you to turn on or off multiple devices or different parts of your machine.
Legend plates (sold separately) give you a way to change your switch’s message.
For technical drawings and 3-D models, click on a part number.
Lever Switches | Legend Plates | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lever Lg. | No. of Circuits Controlled | Switch Action | No. of Terminals | Position Designation | Message | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | Each | Message | Each | ||
2 Position for 10 mm Panel Cutout Dia. | ||||||||||||||
On/Off with Screw Terminals | ||||||||||||||
1 1/2" | 2 | Stays Switched (Maintained) | 4 | Off-On | 0-1 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 3/8" | 0000000 | 000000 | Off-On | 0000000 | 00000 |
1 1/2" | 3 | Stays Switched (Maintained) | 6 | Off-On | 0-1 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 13/16" | 0000000 | 00000 | Off-On | 0000000 | 0000 |
1 13/16" | 2 | Stays Switched (Maintained) | 4 | Off-On | 0-1 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 5/16" | 0000000 | 00000 | Off-On | 0000000 | 0000 |
1 13/16" | 3 | Stays Switched (Maintained) | 6 | Off-On | 0-1 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 3/4" | 0000000 | 00000 | Off-On | 0000000 | 0000 |
1 13/16" | 3 | Stays Switched (Maintained) | 6 | Off-On | 0-1 | 25 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2" | 0000000 | 00000 | Off-On | 0000000 | 0000 |
3 Position for 10 mm Panel Cutout Dia. | ||||||||||||||
Changeover with Screw Terminals | ||||||||||||||
1 1/2" | 2 | Stays Switched (Maintained) | 6 | On-Off-On | 1-0-2 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 13/16" | 0000000 | 00000 | Hand-Off-Auto | 0000000 | 0000 |
1 1/2" | 3 | Stays Switched (Maintained) | 9 | On-Off-On | 1-0-2 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 3/16" | 0000000 | 00000 | Hand-Off-Auto | 0000000 | 0000 |
1 3/4" | 2 | Stays Switched (Maintained) | 6 | On-Off-On | 1-0-2 | 50 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 3 1/8" | 0000000 | 000000 | Hand-Off-Auto | 0000000 | 00000 |
1 3/4" | 2 | Stays Switched (Maintained) | 6 | On-Off-On | 1-0-2 | 63 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 3 1/8" | 0000000 | 000000 | Hand-Off-Auto | 0000000 | 00000 |
1 3/4" | 3 | Stays Switched (Maintained) | 9 | On-Off-On | 1-0-2 | 50 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 3 15/16" | 0000000 | 000000 | Hand-Off-Auto | 0000000 | 00000 |
1 3/4" | 3 | Stays Switched (Maintained) | 9 | On-Off-On | 1-0-2 | 63 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 3 15/16" | 0000000 | 000000 | Hand-Off-Auto | 0000000 | 00000 |
1 13/16" | 2 | Stays Switched (Maintained) | 6 | On-Off-On | 1-0-2 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 3/4" | 0000000 | 00000 | Hand-Off-Auto | 0000000 | 0000 |
1 13/16" | 2 | Stays Switched (Maintained) | 6 | On-Off-On | 1-0-2 | 25 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2" | 0000000 | 00000 | Hand-Off-Auto | 0000000 | 0000 |
1 13/16" | 3 | Stays Switched (Maintained) | 9 | On-Off-On | 1-0-2 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 1/4" | 0000000 | 00000 | Hand-Off-Auto | 0000000 | 0000 |
1 13/16" | 3 | Stays Switched (Maintained) | 9 | On-Off-On | 1-0-2 | 25 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 9/16" | 0000000 | 00000 | Hand-Off-Auto | 0000000 | 0000 |
Selector with Screw Terminals | ||||||||||||||
1 1/2" | 2 | Stays Switched (Maintained) | 6 | Off-On-On | 0-1-2 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 13/16" | 0000000 | 00000 | __ | 000000 | 00 |
1 1/2" | 3 | Stays Switched (Maintained) | 9 | Off-On-On | 0-1-2 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 3/16" | 0000000 | 00000 | __ | 000000 | 00 |
1 13/16" | 2 | Stays Switched (Maintained) | 6 | Off-On-On | 0-1-2 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 3/4" | 0000000 | 00000 | __ | 000000 | 00 |
1 13/16" | 2 | Stays Switched (Maintained) | 6 | Off-On-On | 0-1-2 | 25 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2" | 0000000 | 00000 | __ | 000000 | 00 |
1 13/16" | 3 | Stays Switched (Maintained) | 9 | Off-On-On | 0-1-2 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 1/4" | 0000000 | 00000 | __ | 000000 | 00 |
1 13/16" | 3 | Stays Switched (Maintained) | 9 | Off-On-On | 0-1-2 | 25 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 9/16" | 0000000 | 00000 | __ | 000000 | 00 |
4 Position for 10 mm Panel Cutout Dia. | ||||||||||||||
Selector with Screw Terminals | ||||||||||||||
1 1/2" | 1 | Stays Switched (Maintained) | 4 | Off-On-On-On | 0-1-2-3 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 13/16" | 0000000 | 00000 | __ | 000000 | 00 |
1 13/16" | 1 | Stays Switched (Maintained) | 4 | Off-On-On-On | 0-1-2-3 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 3/4" | 0000000 | 00000 | __ | 000000 | 00 |
5 Position for 10 mm Panel Cutout Dia. | ||||||||||||||
Selector with Screw Terminals | ||||||||||||||
1 1/2" | 1 | Stays Switched (Maintained) | 5 | Off-On-On-On-On | 0-1-2-3-4 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 1 13/16" | 0000000 | 00000 | __ | 000000 | 00 |
6 Position for 10 mm Panel Cutout Dia. | ||||||||||||||
Selector with Screw Terminals | ||||||||||||||
1 1/2" | 1 | Stays Switched (Maintained) | 6 | Off-On-On-On-On-On | 0-1-2-3-4-5 | 12 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 3/16" | 0000000 | 00000 | __ | 000000 | 00 |
1 13/16" | 1 | Stays Switched (Maintained) | 6 | Off-On-On-On-On-On | 0-1-2-3-4-5 | 20 A @ 600 V AC | 600V AC 600V DC | 1 1/8" | 2 1/4" | 0000000 | 00000 | __ | 000000 | 00 |
Push-Pull Switches
The lever sticks out further than a push button, making it easy to identify the position of these switches. They're often used in marine environments.
Switches with a sealed body provide extra protection from moisture and dirt.
Three-position switches close one contact when pulled to the middle position, and close two contacts when pulled all the way.
For technical drawings and 3-D models, click on a part number.
Wire Leads | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switch Position (Function) | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of | Lg. | Each | |
Brass Actuator with Screw Terminals | |||||||||||||
2 Positions | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 3 | SPST-NO | In (Off), Out (On) | 10 A @ 12 V DC | 24V DC | 3/4" | 2 1/8" | __ | __ | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | In (Off or On), Out (On or Off) | 10 A @ 12 V DC | 24V DC | 7/8" | 2 1/8" | __ | __ | 0000000 | 00000 |
3 Positions | |||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | In (Off), Center (On), Out (On) | 10 A @ 12 V DC | 24V DC | 3/4" | 2 7/8" | __ | __ | 0000000 | 00000 |
Brass Actuator with Wire Leads and Sealed Body | |||||||||||||
2 Positions | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | In (Off), Out (On) | 10 A @ 12 V DC | 24V DC | 7/8" | 2" | 2 | 8" | 0000000 | 00000 |
Panel-Mount Timer Switches
Install these switches in a panel cutout to automatically turn electrical equipment on or off after a set interval.
Switches with set time recall retain the last setting; push the button to start the timer over at the same interval, eliminating the need to reset the dial with every use.
Wire Leads | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | Input Voltage | Dia. | Dp. | For Panel Cutout Dia. | For Max. Panel Thick. | Wire Connection Type | No. of Terminals | No. of | Lg. | Each | |
Dial Reset | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 1 13/16" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
Push Reset with Set Time Recall | ||||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 min.-30 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-12 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 1 hrs.-60 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 2 hrs.-24 hrs. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 15 A @ 125 V AC/250 V AC | 5 min.-60 min. | 120V AC | 3 1/16" | 2 1/8" | 3/8" | 1/8" | Quick-Disconnect Terminals/Wire Leads | 2 | 2 | 8" | 0000000 | 000000 |
Panel-Mount Compact Disconnect Switches
Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included). They’re rated IP65 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 3PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 3PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 3PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 000000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 3PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 000000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
Yellow Plastic Housing with Red Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 3PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 3PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 3PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 3PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
Panel-Mount Disconnect Switches
Install these switches in a panel cutout. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All are UL listed, C-UL listed, and CE marked—they meet American, Canadian, and European safety standards.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
Terminal covers prevent contact with live terminals.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Environmental Rating | Each | |
Yellow Plastic Housing with Red Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 000000 |
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 00000 |
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 00000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
Gray Plastic Housing with Gray Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 00000 |
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 1/2" | 2 1/2" | 2" | IP40 | 00000000 | 00000 |
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 00000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/4" | 3 3/4" | 2 11/16" | IP40 | 00000000 | 000000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
25 | 600V AC | 3PST | Single (1 1/2 hp @ 240 V AC) Single (3/4 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
32 | 600V AC | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2" | IP40 | 00000000 | 00000 |
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (3 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (10 hp @ 240 V AC) Single (5 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 2 11/16" | IP40 | 00000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Single-Action Air Directional Control Valves
Manually control these valves by pushing or turning the actuator. Also known as 3-way or 3/2 valves, they create one action, such as extending a cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves block airflow until actuated.
Valves with hand return actuation stay actuated and go back to their starting position only when you move the actuator again.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | For Inlet Tube ID | For Outlet Tube ID | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | ||
Normally Closed Flow Positions | |||||||||||||||
Hand Return Actuation | |||||||||||||||
G | 3 | 1/16" | 1/16" | Barbed | 2.2 | 0.04 | 0-125 | 20 | 5/8" | 3/8" | 1 5/8" | 3/8" | Yes | 00000000 | 000000 |
Rotary Control Cables
Transmit rotary motion to operate valves, throttle controls, and HVAC damper controls. These cables are flexible, so you can weave them around obstructions to manipulate controls from a distance. They have a D-profile shaft on one end for installing a manual control knob and a set screw on the other end for securing to a shaft. Push the male end of the shaft through a panel cutout and secure with locknuts.
Cables with a plastic cover protect the core from bending. The cover also helps to prevent injury from the rotating cable.
Cables with sleeve bearings last longer than cables without them because the bearings support the connection between the coupling and core.
For technical drawings and 3-D models, click on a part number.
Maximum Torque @ | Cable | Male Fitting | Female Fitting | Panel-Mount Cables | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
12" Bend Radius, in.-lbs. | 50" Bend Radius, in.-lbs. | Overall Lg., ft. | OD | Core Dia. | Bend Radius | Shaft Dia. | For Panel Cutout Dia. | Lg. | For Shaft Dia. | Lg. | Fitting Material | Bearing Material | Temp. Range, °F | Each | |
Steel Cable Core | |||||||||||||||
7.5 | 7.5 | 1/2 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
7.5 | 7.5 | 1 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
7.5 | 7.5 | 1 1/2 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
7.5 | 7.5 | 2 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
7.5 | 7.5 | 3 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
24 | 26 | 1 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
24 | 26 | 1 1/2 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 2 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 3 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
Steel Cable Core with Plastic Cover | |||||||||||||||
24 | 26 | 1 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 1 1/2 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 2 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 3 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
Steel Cable Core with Plastic Cover and Sleeve Bearings | |||||||||||||||
24 | 26 | 3 | 0.39" | 0.188" | 4" | 1/4" | 3/8" | 2 1/2" | 1/4" | 2 7/16" | Zinc-Plated Steel | Bronze | 40° to 190° | 0000000 | 000000 |
24 | 26 | 4 | 0.39" | 0.188" | 4" | 1/4" | 3/8" | 2 1/2" | 1/4" | 2 7/16" | Zinc-Plated Steel | Bronze | 40° to 190° | 0000000 | 000000 |
24 | 26 | 6 | 0.39" | 0.188" | 4" | 1/4" | 3/8" | 2 1/2" | 1/4" | 2 7/16" | Zinc-Plated Steel | Bronze | 40° to 190° | 0000000 | 000000 |