No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Cover Color | Switching Current @ Voltage | Max. Voltage | Dia. | Environmental Rating | Each | |
Metal Actuator with Screw Terminals and Positive Force Contacts | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Chrome | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 0000000 |
Plastic Actuator with Screw Terminals | ||||||||||||
2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | Black | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
Plastic Actuator with Screw Terminals and Positive Force Contacts | ||||||||||||
1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | SPST-NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | SPST-NC | Yellow | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Black | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Green | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Yellow | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
Emergency Stop Outlet-Box-Mount Push-Button Switches
Immediately cut power with a single push. The large palm-sized buttons on these switches provide an easy target, so they're easy to use even while wearing gloves. When the button is depressed, the switch latches and can be locked in that position using a lockout or padlock with a 9/32” shackle diameter (not included). All have positive force contacts that will open the circuit when actuated even if a spring fails or the contacts stick. They're rated NEMA 13 and IP65 for protection from oil/coolant spraying and washdowns.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Cover Color | Switching Current @ Voltage | Max. Voltage | Dia. | Environmental Rating | Specifications Met | Each | |
Plastic Actuator with Screw Terminals | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 125 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | UL Listed, CSA Certified, CSA-US Certified, CE Marked, UL 508, EN 60947-5-5, IEC 60947-5-5 | 00000000 | 0000000 |
High-Amp Outlet-Box-Mount Key Switches
Able to withstand high currents, these switches can be used with motors and pumps. They require a key to turn circuits on or off, limiting access to sensitive equipment. All are keyed alike, so they open with the same key.
For technical drawings and 3-D models, click on a part number.
Key | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Horsepower @ Switching Voltage | Dia. | No. of Keys Included | Keying | Removal Position | Each | |
2 Position with Metal Base | |||||||||||||
Keyed Alike with Screw Terminals | |||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 20 A @ 120 V AC | 277V AC | 1 hp @ 120 V AC | 7/8" | 2 | Keyed Alike | Center | 000000 | 0000000 |
Outlet-Box-Mount Key Switches
Reset fire panels, or open electromagnetic locks, electric strikes, and automatic door openers. These switches require a key to turn circuits on or off, limiting access and preventing accidental activation. The lock is not included; use a 1 1/4" long mortise lock with a standard cam.
For technical drawings and 3-D models, click on a part number.
Wire Leads | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Max. Voltage | Dia. | No. of | Lg. | Includes | Each | ||
2 Position | ||||||||||||
With Wire Leads | ||||||||||||
2 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | 3 | SPDT | 250V AC | 1 3/16" | 3 | 5" | Screwdriver, Tamper-Resistant Screws | 3 A @ 125 V AC, 1 A @ 250 V AC | 00000000 | 0000000 |
2 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 250V AC | 1 3/16" | 3 | 5" | Screwdriver, Tamper-Resistant Screws | 3 A @ 125 V AC, 1 A @ 250 V AC | 00000000 | 000000 |
Multi-Way Wall-Mount Motion-Sensing Light Controls
Control lights on a single circuit from more than one motion-sensing switch. Also known as occupancy sensors, these controls turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. Use up to four controls on the same circuit to detect motion in large rooms. All have a time delay to turn lights off after a set time.
Coverage, sq. ft. | No. of Circuits Controlled | Max. No. per Circuit | Input Voltage | Wattage | For Outlet Box Type | Max. Mounting Ht., ft. | Color | Housing Material | Wire Connection Type | Specifications Met | Each | |
1,050 | 1 | 4 | 120V AC | 600 W @ 120 V AC | 1 Device (1 Gang) | 4 | White | Plastic | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
Wall-Mount Timer Switches
Use these switches in place of standard wall switches to automatically turn electrical equipment on or off after a set interval of time. They’re often used with lights.
Switches with override can bypass the automatic shut-off.
Set switches with beep and light signals to alert when the timer is almost done; the signals can also be turned off.
Switches with set time recall retain the last setting; hold the button down to restart the timer with that setting.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Choose a Knob Color | Each | |
Without Override | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 40 sec.-5 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 000000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
With Override | ||||||||
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 |
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Knob Color | Each | |
Without Override | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-5 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 000000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 4 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 0000000 | 00000 |
With Override | ||||||||
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-5 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 4 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
Replacement Knob | 0000000 | Each | 00000 |
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Color | CSA File Number | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 15 A @ 120 V AC | 2 hrs., 4 hrs., 8 hrs., 12 hrs. | 1 Device (1 Gang) | Wire Leads | White | __ | 00000000 | 000000 |
1 | 1 Off (Normally Open) | 15 A @ 120 V AC | 5 min., 10 min., 15 min., 30 min. | 1 Device (1 Gang) | Wire Leads | White | 003413_0_000 | 00000000 | 00000 |
Countdown LCD
and Set Time Recall
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Choose a Color | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 41 mA @ 24 V AC, 12 mA @ 24 V DC | __ | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 000000 | |
1 | 1 Off (Normally Open) | 6.6 A @ 120 V AC, 4.3 A @ 277 V AC | 1/6 hp @ 125 V AC | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 00000 |
Time-Delay Wall-Mount Timer Switches
Control two devices and delay the shut off of one device by up to one hour. These switches are often used with lights and fans for ventilation. All have an override that bypasses the automatic shut-off.
For technical drawings and 3-D models, click on a part number.
Color | No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time, min. | For Outlet Box Type | Wire Connection Type | Each | |
Ivory | 2 | 1 Off (Normally Open) | 4.1 A @ 120 V AC | 1/3 hp @ 120 V AC | 1-60 | 1 Device (1 Gang) | Wire Leads | 0000000 | 000000 |
White | 2 | 1 Off (Normally Open) | 4.1 A @ 120 V AC | 1/3 hp @ 120 V AC | 1-60 | 1 Device (1 Gang) | Wire Leads | 0000000 | 00000 |
Outlet-Box-Mount Time and Day Activated Switches
Switches fit single device (1 gang) outlet boxes. Program them to turn a device on and off at a set time and day. They’re often used with lamps and other small electrical loads.
24-hour switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
Seven-day switches can perform a different program each day of the week. Use the astronomical timing to turn lights on and off based on sunrise and sunset; this option can be used independently or in combination with timed programming.
No. of Circuits Controlled | Switching Current @ Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | Features | Industry Designation | For Outlet Box Type | Wire Connection Type | Wire Lead Lg. | Each | |
24-Hour Timing Cycle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 20 A @ 120 V AC | 24 per Day | 30 min. | Trippers | Captive | On/Off/Timer Selector | SPST | 1 Device (1 Gang) | Wire Leads | 6" | 000000 | 000000 |
7-Day Timing Cycle | ||||||||||||
1 | 15 A @ 120 V AC | 40 per Week | 1 min. | Push Button | __ | Astronomical Timing, Battery Backup, LCD Display | __ | 1 Device (1 Gang) | Wire Leads | 6" | 0000000 | 00000 |
Remote Test Stations for Smoke Detectors for HVAC Systems
Check that your HVAC smoke detector is working properly. Wire these test stations to your smoke detector controller to test difficult to access smoke detectors from a convenient location. Indicator lights show if your smoke detector is powered on, if it senses smoke, and if its sensors are too dirty to detect smoke and need cleaning. These test stations activate with the turn of a key so you don’t turn them on by accident.
Actuator Style | Switch Starting Position | No. of Terminals | Industry Designation | Voltage | Temp. Range, °F | Wire Connection Type | Wd. | Ht. | Mounting Hardware Included | Specifications Met | Each | |
Key | 1 Off (Normally Open) | 5 | SPST-NO | 24V AC, 24V DC, 120V AC, 230V AC | 32° to 130° | Screw Terminals | 3" | 4 3/4" | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 000000 |
Ready-to-Use Steel Outlet Boxes
These boxes come ready to use with receptacles and/or light switches installed. Use the included plug-in connectors with wire leads to connect the receptacles and/or light switches. See information about NEMA straight-blade receptacles.
Use outlet boxes with toggle or rocker switches to control lighting.
For technical drawings and 3-D models, click on a part number.
Wire Leads for Switches | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Industry Designation | No. of | Gauge | Industry Designation | Lg. | Switching Voltage | Switching Current | Ht. | Wd. | Dp. | No. of Knockouts | Knockout Trade Size | Material | Each | |
With 1 Toggle Switch | ||||||||||||||
1 Gang | 3 | 12 | THHN | 6" | 120V AC, 277V AC | 20A | 4" | 2 1/8" | 1 7/8" | 10 | 1/2 | Zinc-Plated Steel | 00000000 | 000000 |
With 1 Rocker Switch | ||||||||||||||
1 Gang | 3 | 12 | THHN | 6" | 120V AC, 277V AC | 15A | 4" | 2 1/8" | 1 7/8" | 10 | 1/2 | Zinc-Plated Steel | 00000000 | 00000 |
1 Gang | 3 | 12 | THHN | 6" | 120V AC, 277V AC | 20A | 4" | 2 1/8" | 1 7/8" | 10 | 1/2 | Zinc-Plated Steel | 00000000 | 00000 |
For Device Type | Each | |