About NEMA Straight-Blade Plugs, Connectors, and Receptacles
More
About NEMA Plugs, Sockets, and Receptacles
More
Outlet Strips
Provide power to multiple devices with these outlet strips. A circuit breaker prevents damage from current overload and short circuits.
Use outlet strips with USB ports to charge mobile devices. Telephone connections connect to a land line. Coaxial connections connect to F-type coaxial cords for video.
90° elbow plugs fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
Outlet strips with 90° and 360° outlet orientation accommodate large plugs. The face of 360° outlets rotate a full circle.
Surge suppression outlet strips protect against damage from voltage spikes. Surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced; the higher the number, the better the protection.
Outlet strips with an audible alarm alert you when the strip is damaged and needs replacement.



No. of Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outlets | NEMA 5-15 | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||||
5 | 5 | 3" | 6 | 15 | 125V AC | Lighted Power Switch | Aluminum | 1175J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 0000000 |
6 | 6 | 1" | 4 | 15 | 125V AC | Lighted Power Switch | ABS Plastic | 790J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 00000 |
6 | 6 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch | Steel | 1340J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 00000 |
10 | 10 | 4" | 15 | 15 | 125V AC | Lighted Power Switch | Aluminum | 675J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 000000 |
11 | 11 | 6" | 15 | 15 | 125V AC | Lighted Power Switch | Aluminum | 675J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 000000 |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||||
7 | 7 | 1" | 7 | 15 | 125V AC | Power Switch | ABS Plastic | 2160J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 00000 |
8 | 8 | 2 1/4" | 6 | 15 | 125V AC | Lighted Power Switch | PVC Plastic | 675J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 00000 |




No. of Outlets | Outlet Center -to-Center (No.) | USB Connection Type (No.of Ports) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
5 | 1 1/2" (4) 1 5/8" (1) | A (1) C (1) | 6 | 15 | 120V AC | Lighted Power Switch | Steel | 2100J | Circuit Breaker, Surge Suppression | UL Listed, C-UL Listed | 0000000 | 000000 |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||||
4 | 1 7/8" (4) | A (4) | 5 | 15 | 120V AC | Power Switch, Power-Indicating Light, 360° Rotating Outlets | ABS Plastic | 1080J | Circuit Breaker, Surge Suppression | ETL Listed, C-ETL Listed | 0000000 | 00000 |
4 | 1 7/8" (4) | A (2) C (2) | 6 | 15 | 120V AC | Power Switch, Power-Indicating Light, 360° Rotating Outlets | ABS Plastic | 1080J | Circuit Breaker, Surge Suppression | ETL Listed, C-ETL Listed | 0000000 | 000000 |



Telephone | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Connection Type | No. of Jacks | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | |||||||||||||
6 | 1 1/2" (4) 1 3/4" (2) | RJ11 | 2 | 15 | 15 | 125V AC | Lighted Power Switch | Steel | 1340J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 000000 |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||||
8 | 2 1/4" (8) | RJ11 | 2 | 6 | 15 | 125V AC | Lighted Power Switch | PVC Plastic | 675J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 00000 |



Telephone | Coaxial | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Connection Type | No. of Jacks | Connection Type | No. of Jacks | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||||||
8 | 1 1/2" (5) 2 1/4" (3) | RJ11 | 3 | F-Type | 2 | 8 | 15 | 125V AC | Lighted Power Switch, Audible Alarm | ABS Plastic | 2160J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 000000 |
8 | 2 1/4" (8) | RJ11 | 2 | F-Type | 4 | 6 | 15 | 125V AC | Lighted Power Switch | PVC Plastic | 675J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 00000 |
Outlet Strips with Remote Switch




The power switch to these outlet strips is on an extension cord, so you can control power even when the strips are in hard to reach places, such as under a desk. A circuit breaker prevents damage from current overload and short circuits. Surge suppression protects devices from voltage spikes. The surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced.
90° elbow plugs fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
No. of Outlets | Outlet Ctr.-to-Ctr. | Power Cord Lg., ft. | Remote Switch Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Includes | Specifications Met | Color | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 1 1/4" | 6 | 3 1/2 | 15 | 120V AC | Lighted Power Switch on Cord | Aluminum | 1080J | Circuit Breaker, Surge Suppression | Mounting Clips | UL Listed, C-UL Listed | White | 00000000 | 0000000 |
6 | 1 1/4" | 15 | 3 1/2 | 15 | 120V AC | Lighted Power Switch on Cord | Aluminum | 1080J | Circuit Breaker, Surge Suppression | Mounting Clips | UL Listed, C-UL Listed | White | 00000000 | 000000 |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||||||
8 | 1 9/16" | 12 | 7 | 12 | 120V AC | Lighted Power Switch on Cord | Metal | 3840J | Circuit Breaker, Surge Suppression | Mounting Clips | __ | Gray | 00000000 | 000000 |
Outlet Strips with Master Outlet
Save energy by automatically turning off unused outlets—the master outlet controls the follower outlets and shuts off power to those outlets when a device plugged into the master is turned off. For example, plug a main device, such as a computer, into the master outlet; plug accessory devices, such as a monitor and printer, into the follower outlets. Turn the main device on and off to control power to the accessory devices. They also have independent outlets that are always on. Sliding outlet covers protect outlets from dust when not in use. Surge suppression protects devices from voltage spikes. The surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced. Telephone connections connect to a land line. Coaxial connections connect to F-type coaxial cords for video. A circuit breaker prevents damage from current overload and short circuits.



Telephone | Coaxial | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Connection Type | No. of Jacks | Connection Type | No. of Jacks | Cord Lg., ft. | Current, A | Voltage | Material | Surge Rating | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||||||
12 Total 1 Master 7 Followers 4 Independent | 1" (8) 2 1/4" (4) | RJ45 | 3 | F-Type | 2 | 8 | 15 | 125V AC | ABS Plastic | 2880J | Circuit Breaker, Surge Suppression | UL Listed C-UL Listed | 00000000 | 000000 |
Interference-Limiting Electronic Equipment Outlet Strips



A filter through the middle isolates two pairs of outlets, so high voltage equipment plugged into one pair won’t affect the other pair. This prevents equipment that generates signal interference, such as transformers, from interfering with sensitive equipment plugged into the other side of the outlet strip. The circuit breaker prevents damage from current overload and short circuits. The surge suppression protects against damage from voltage spikes. Use these outlet strips with computers, lab equipment, and other machines that have IEC connections.
No. of Outlets | Outlet Ctr.-to-Ctr. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Includes | Color | Each | |
IEC C13 Socket with IEC C14 Plug | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
4 | 2 1/16" | 9 | 240V AC | Lighted Power Switch | Metal | 680J | Circuit Breaker, Surge Suppression | 6 ft. Long IEC C14 Plug × IEC C13 Socket Power Cable | Gray | 0000000 | 0000000 |
Interference-Limiting Outlet Strips
Filters between the outlets on these strips protect computers and other sensitive equipment from external signals that interfere with the equipment’s performance. A circuit breaker prevents damage from current overload and short circuits. Surge suppression protects devices from voltage spikes. The surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced; the higher the number, the better the protection.



No. of Outlets | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Current, A | Voltage | Features | Surge Rating | Material | Protection Type | Circuit Breaker Trip Current, A | Specifications Met | Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch | 1450J | Steel | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 000000 |
4 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch | 3330J | Steel | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 00000 |
6 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch | 3300J | Steel | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 00000 |
8 | 1 1/2" | 12 | 15 | 125V AC | Lighted Power Switch | 3840J | Steel | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 000000 |



Telephone | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Outlet Ctr.-to-Ctr. | Connection Type | No. of Jacks | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Circuit Breaker Trip Current, A | Specifications Met | Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | |||||||||||||||
6 | 1 1/2" | RJ11 | 2 | 6 | 15 | 125V AC | Lighted Power Switch | Steel | 3300J | Circuit Breaker, Surge Suppression | 12 | UL Listed | Gray | 0000000 | 0000000 |
GFCI Outlet Strips




Keep personnel safe from electric shock with ground fault protection.
90° elbow plugs fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
Outlet strips with a circuit breaker prevent damage from current overload and short circuits.
Outlet strips with a manual reset prevent equipment from starting up unexpectedly after ground is established.
Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Protection Type | Reset Type | Specifications Met | Color | Each | |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
6 | 1 1/4" (4) 1 3/4" (2) | 9 | 15 | 125V AC | Test Button, Lighted Power Switch | Steel | Circuit Breaker, GFCI | Manual | UL Listed | Yellow | 0000000 | 0000000 |
8 | 1" (5) 2" (3) | 12 | 15 | 125V AC | Test Button, Lighted Power Switch | Steel | Circuit Breaker, GFCI | Manual | UL Listed | Yellow | 0000000 | 000000 |
8 | 1" (5) 2" (3) | 25 | 15 | 125V AC | Test Button, Lighted Power Switch | Steel | Circuit Breaker, GFCI | Manual | UL Listed | Yellow | 0000000 | 000000 |
Sure-Grip Outlet Strips
Also known as hospital-grade outlet strips, these outlets have an extra-tight fit to prevent plugs from detaching. They are marked with a green dot. A circuit breaker prevents damage from current overload and short circuits.
Surge suppression outlet strips protect against damage from voltage spikes. The surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced.



Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
6 | 1 1/2" (6) | 15 | 15 | 125V AC | Green Dot, Lighted Power Switch | Steel | 1050J | Circuit Breaker, Surge Suppression | UL Listed | 0000000 | 0000000 |
Outlet Splitters







Convert one outlet into multiple outlets.
Style D has a durable metal housing. It includes mounting hardware to attach to a receptacle.
Styles E-J have USB ports to charge mobile devices.
Style J has three hinged outlets that allows you to pivot outlets to the side, keeping cords close to the wall.
Splitters with surge suppression protect devices from voltage spikes. Surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced. The higher the number, the better the protection.




Style | No. of Outlets | Current, A | Voltage | Material | Surge Rating | Protection Type | Includes | Specifications Met | Choose a Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
C | 6 | 15 | 125V AC | Plastic | 750J | Surge Suppression | __ | UL Listed | Gray | 0000000 | 000000 |
D | 2 | 15 | 125V AC | Metal | 1410J | Surge Suppression | Mounting Hardware | ETL Listed, C-ETL Listed | 00000000 | 00000 |





Current, A | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Outlets | USB Connection Type (No. of Ports) | NEMA 5-15 Socket | USB Port | Voltage | Features | Material | Surge Rating | Protection Type | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||||
G | 3 | A (2) | 15 | 3.4 | 125V AC | __ | Plastic | 950J | Surge Suppression | ETL Listed, C-ETL Listed | White | 0000000 | 000000 |
H | 6 | A (1) C (1) | 15 | 2.1 3 | 125V AC | __ | Plastic | 950J | Surge Suppression | ETL Listed, C-ETL Listed | White | 0000000 | 00000 |
J | 6 | A (2) | 15 | 3.4 | 125V AC | Three Hinged Outlets, Three Side Outlets | Plastic | 1200J | Surge Suppression | ETL Listed, C-ETL Listed | White | 0000000 | 00000 |
Rack-Mount Outlet Strips

Mount these strips into standard 19” wide electronics racks, enclosures, and cabinets. All have a circuit breaker to prevent damage from current overload and short circuits.
Front outlets power external components. Rear outlets power components inside the cabinet.
Surge suppression outlet strips protect against damage from voltage spikes. Surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced; the higher the number, the better the protection.




Mounting Holes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outlets | Outlet Ctr.-to-Ctr. | Cord Lg., ft. | Current, A | Voltage | Features | Material | Surge Rating | Protection Type | Mounting Fasteners Included | No. of | Dia. | Specifications Met | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||||||
Outlet Strips with Rear Outlets | ||||||||||||||
6 | 1 1/2" | 6 | 15 | 125V AC | Lighted Power Switch, Power-Indicating Light | Steel | 1175J | Circuit Breaker, Surge Suppression | No | 4 | 0.25" | C-UL Recognized Component, UL Recognized Component | 0000000 | 0000000 |
6 | 1 1/2" | 15 | 15 | 125V AC | Lighted Power Switch, Power-Indicating Light | Steel | 1175J | Circuit Breaker, Surge Suppression | No | 4 | 0.25" | C-UL Recognized Component, UL Recognized Component | 0000000 | 000000 |
10 | 1 1/2" | 10 | 15 | 125V AC | Power Switch, Power-Indicating Light | Steel | 720J | Circuit Breaker, Surge Suppression | No | 4 | 0.25" | UL Listed, C-UL Listed | 0000000 | 000000 |
Outlet Strips with Front and Rear Outlets | ||||||||||||||
8 | 3 1/4" | 10 | 15 | 125V AC | Power Switch, Power-Indicating Light | Steel | 720J | Circuit Breaker, Surge Suppression | No | 4 | 0.25" | UL Listed, C-UL Listed | 0000000 | 000000 |
Outlet Adapters


Adapters with surge suppression protect against damage from voltage spikes. Surge rating indicates how much energy the outlet strip can absorb before it needs to be replaced.
For technical drawings and 3-D models, click on a part number.
No. of Outlets | Current, A | Voltage | Material | Surge Rating | Protection Type | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 15 | 125V AC | Plastic | 900J | Surge Suppression | ETL Listed, C-ETL Listed | White | 0000000 | 000000 |
Surge-Suppressing DIN-Rail Mount Straight-Blade Receptacles

Prevent damage to electronic equipment caused by spikes in voltage. Receptacles have an audible alarm to indicate a loss of surge protection. They mount to DIN rail to bring power closer to where you need it.
For technical drawings and 3-D models, click on a part number.

NEMA Style | Voltage | Current | Ht. | Wd. | Dp. | Wire Connection Type | For Wire Gauge | Receptacle Terminal Location | For DIN Rail Ht., mm | Features | Mounting Box Color | Color | Each | |
Grounded | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | 4.9" | 3.3" | 2.5" | Screw Terminals | 16-12 | Side | 35 | Audible Alarm, Power-Indicating Light | Gray | Gray | 0000000 | 0000000 |
Surge-Suppressing Straight-Blade Receptacles
Prevent damage to electronic equipment caused by spikes in voltage. An indicating light turns green when receptacles have power and are protected. A flashing red light and an audible alarm indicate power but no surge protection. Receptacles provide an extra-tight fit when mated with a plug to remain secure in high-vibration environments. They're also known as hospital-grade receptacles. All fit standard GFCI wall plates (not included).
For technical drawings and 3-D models, click on a part number.



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Audible Alarm with On/Off Switch, Green Dot, Power-Indicating Light | Ivory | 0000000 | 000000 |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Audible Alarm with On/Off Switch, Green Dot, Power-Indicating Light | Ivory | 000000 | 00000 |
Interference-Limiting Surge-Suppressing Straight-Blade Receptacles
Receptacles protect sensitive equipment from electromagnetic interference (EMI) and spikes in voltage. An isolated ground connection blocks EMI. The indicating light turns green when receptacles have power and are protected. A flashing red light and an audible alarm indicate power but no surge protection. When mated with a plug, receptacles provide an extra-tight fit to remain secure in high-vibration applications. Also known as hospital-grade receptacles. They fit standard GFCI wall plates (not included).
For technical drawings and 3-D models, click on a part number.



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Audible Alarm with On/Off Switch, Green Dot, Green Triangle, Isolated Ground Connection, Power-Indicating Light | Orange | 000000 | 0000000 |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Audible Alarm with On/Off Switch, Green Dot, Green Triangle, Isolated Ground Connection, Power-Indicating Light | Orange | 000000 | 000000 |