Submersible Liquid-Level Transmitters
Best for measuring liquid levels in applications where traditional mounting is difficult, these transmitters sit at the bottom of your tank. They sense liquid levels by measuring the pressure from the weight of the liquid above them. These transmitters continuously send measurements, so you can monitor the status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
Transmitters for liquids with solids have sink weights that keep the transmitter in place in applications with moving solids or agitated liquids.
For technical drawings and 3-D models, click on a part number.
For Pressure Range | Overall | Temp. Range, °F | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ft. of H2O | psi | Accuracy | Max. Pressure | Dia. | Lg. | Min. | Max. | Cable Lg., ft. | Input Voltage | For Container Type | Electrical Connection Type | Environmental Rating | Each | |
4-20mA Output Current | ||||||||||||||
For Liquids | ||||||||||||||
0-11.5 | 0-5 | ±0.5% | 7 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 0000000 |
0-23 | 0-10 | ±0.5% | 15 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-34 | 0-15 | ±0.5% | 22 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-46 | 0-20 | ±0.5% | 30 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
For Liquids with Solids | ||||||||||||||
0-11.5 | 0-5 | ±0.5% | 7 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-23 | 0-10 | ±0.5% | 15 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-34 | 0-15 | ±0.5% | 22 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-46 | 0-20 | ±0.5% | 30 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
Hazardous-Location Submersible Liquid-Level Transmitters
FM and C-FM approved, these transmitters safely measure liquid levels where explosive gas or dust may be present. Set them at the bottom of your tank in applications that make traditional mounting difficult. They sense liquid levels by measuring the pressure from the weight of the liquid above them. All continuously send measurements, so you can monitor status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
Transmitters for liquids with solids have an unobstructed sensing element that resists clogging and sludge buildup in water with particulate and sewage.
For technical drawings and 3-D models, click on a part number.
For Pressure Range | Overall | Temp. Range, °F | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ft. of H2O | psi | Accuracy | Max. Pressure | Lg. | Dia. | Min. | Max. | Cable Lg., ft. | Input Voltage | For Container Type | Electrical Connection | Environmental Rating | Each | |
4-20mA Output Current | ||||||||||||||
For Liquids | ||||||||||||||
0-3 | 0-1 | ±0.25% | 10 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 0000000 |
0-5 | 0-2 | ±0.25% | 20 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-10 | 0-4 | ±0.25% | 40 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-15 | 0-6 | ±0.25% | 60 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-30 | 0-13 | ±0.25% | 125 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
For Liquids with Solids | ||||||||||||||
0-3 | 0-1 | ±0.25% | 10 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-5 | 0-2 | ±0.25% | 20 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-10 | 0-4 | ±0.25% | 40 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-15 | 0-6 | ±0.25% | 60 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-30 | 0-13 | ±0.25% | 125 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |