Filter by
Switching Voltage
Switch Designation
Switch Starting Position
Switch 2nd Signal Starting Position
DFARS Specialty Metals
Export Control Classification Number (ECCN)
REACH
RoHS
Sequenced Latching Relays

These relays switch through a series of different circuit configurations every time they receive an input voltage. The input voltage latches them in position, so they don’t require a constant voltage to stay switched. Use them to control motors, pumps, and lighting. The covered terminals prevent contact with live connections. Mount to 35 mm DIN rail. Also known as step relays.
For technical drawings and 3-D models, click on a part number.
Switch Starting Position | Input Voltage | Control Power | Switching Current @ 120V AC | Max. Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Each | |
1 Circuit Controlled—SPST-NO | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
With 4 Terminals | ||||||||||
1st Signal—1 Off (Normally Open) 2nd Signal—1 On (Normally Closed) | 24V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 000000 |
1st Signal—1 Off (Normally Open) 2nd Signal—1 On (Normally Closed) | 120V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—1 Off (Normally Open) 2nd Signal—1 On (Normally Closed) | 240V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—1 Off (Normally Open) 2nd Signal—1 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—1 Off (Normally Open) 2nd Signal—1 On (Normally Closed) | 24V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
2 Circuits Controlled—DPST-1NO/1NC | ||||||||||
With 6 Terminals | ||||||||||
1st Signal—1 Off (Normally Open) and 1 On (Normally Closed) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) | 24V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—1 Off (Normally Open) and 1 On (Normally Closed) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) | 120V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—1 Off (Normally Open) and 1 On (Normally Closed) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) | 240V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—1 Off (Normally Open) and 1 On (Normally Closed) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—1 Off (Normally Open) and 1 On (Normally Closed) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) | 24V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
2 Circuits Controlled—DPST-NO | ||||||||||
With 6 Terminals | ||||||||||
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 24V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 120V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 240V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—2 On (Normally Closed) | 24V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 24V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 120V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 240V AC | 6.5VA | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 12V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |
1st Signal—2 Off (Normally Open) 2nd Signal—1 On (Normally Closed) and 1 Off (Normally Open) 3rd Signal—2 On (Normally Closed) | 24V DC | 5W | 16A | 277V AC | 1/2 hp @ 120 V AC | 3.3" | 0.7" | 2.4" | 00000000 | 00000 |