We will reply to your message within an hour.
More
Reduce the knockout size in an outlet box or enclosure so you can attach a different size of conduit to it.
Join pieces of conduit.
Attach conduit to a knockout in an outlet box or enclosure.
Join different sizes of conduit.
Seal out moisture while reducing the knockout size in an outlet box or enclosure so you can attach a different size of conduit to it.
This impact- and crush-resistant conduit is also known as galvanized rigid conduit (GRC).
Also known as intermediate metallic conduit (IMC), this is lighter in weight than thick-wall (rigid) steel conduit, yet it has the same strength.
Also known as electrical metallic tubing (EMT), this conduit has thin walls that easily bend with a conduit bender and can be cut with a hacksaw.
Visually identify different runs of wire and cable along walls and ceilings with this conduit that has a painted exterior.
Also known as FMC, this conduit offers the crush resistance of metal combined with flexibility to handle bends in tight spaces.
When used with liquid-tight fittings, this conduit seals out liquid. The steel core provides crush resistance, and the cover is UV light resistant.
Run conduit in food areas—the cover can be cleaned and sterilized without weakening or splitting. This conduit meets NSF/ANSI standard 169 for special-purpose food equipment.
The toughest liquid-tight flexible metal conduit we offer, this resists oil, chemicals, and extreme temperature fluctuations.
In addition to resisting oil, this conduit resists lubricants and grease.
Even in temperatures as low as -50° F and as high as 220° F, this conduit stays flexible.
These fittings seal out liquids when connecting liquid-tight flexible metal conduit to a knockout in an outlet box or enclosure.
These fittings seal out liquid when used with continuous-flex liquid-tight plastic conduit.
Transition between types of conduit.
Route power, data, and control cable rated up to 600 volts AC/DC.
Protect wire and cable from dust, dirt, and oil/coolant dripping—this raceway is rated NEMA 12.
Gaskets on the covers and at connection points protect against dust as well as seeping oil and coolant.
This raceway system is also known as wireway and wire trough.
With a top that overhangs the cover, this raceway keeps out rain. It is rated NEMA 3R for protection from liquids and light splashing.
Create a permanent outlet system without opening walls. These outlet strips mount to a wall with clips and hardwire to an existing electrical system.