Hazardous-Location Submersible Liquid-Level Transmitters
FM and C-FM approved, these transmitters safely measure liquid levels where explosive gas or dust may be present. Set them at the bottom of your tank in applications that make traditional mounting difficult. They sense liquid levels by measuring the pressure from the weight of the liquid above them. All continuously send measurements, so you can monitor status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
Transmitters for liquids with solids have an unobstructed sensing element that resists clogging and sludge buildup in water with particulate and sewage.
For technical drawings and 3-D models, click on a part number.
For Pressure Range | Overall | Temp. Range, °F | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ft. of H2O | psi | Accuracy | Max. Pressure | Lg. | Dia. | Min. | Max. | Cable Lg., ft. | Input Voltage | For Container Type | Electrical Connection | Environmental Rating | Each | |
4-20mA Output Current | ||||||||||||||
For Liquids | ||||||||||||||
0-3 | 0-1 | ±0.25% | 10 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 0000000 |
0-5 | 0-2 | ±0.25% | 20 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-10 | 0-4 | ±0.25% | 40 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-15 | 0-6 | ±0.25% | 60 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-30 | 0-13 | ±0.25% | 125 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
For Liquids with Solids | ||||||||||||||
0-3 | 0-1 | ±0.25% | 10 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-5 | 0-2 | ±0.25% | 20 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-10 | 0-4 | ±0.25% | 40 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-15 | 0-6 | ±0.25% | 60 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-30 | 0-13 | ±0.25% | 125 psi @ 70° F | 5 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
Submersible Liquid-Level Transmitters
Best for measuring liquid levels in applications where traditional mounting is difficult, these transmitters sit at the bottom of your tank. They sense liquid levels by measuring the pressure from the weight of the liquid above them. These transmitters continuously send measurements, so you can monitor the status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
Transmitters for liquids with solids have sink weights that keep the transmitter in place in applications with moving solids or agitated liquids.
For technical drawings and 3-D models, click on a part number.
For Pressure Range | Overall | Temp. Range, °F | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ft. of H2O | psi | Accuracy | Max. Pressure | Dia. | Lg. | Min. | Max. | Cable Lg., ft. | Input Voltage | For Container Type | Electrical Connection Type | Environmental Rating | Each | |
4-20mA Output Current | ||||||||||||||
For Liquids | ||||||||||||||
0-11.5 | 0-5 | ±0.5% | 7 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 0000000 |
0-23 | 0-10 | ±0.5% | 15 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-34 | 0-15 | ±0.5% | 22 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-46 | 0-20 | ±0.5% | 30 psi @ 70° F | 1" | 5 5/8" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
For Liquids with Solids | ||||||||||||||
0-11.5 | 0-5 | ±0.5% | 7 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-23 | 0-10 | ±0.5% | 15 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 40 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-34 | 0-15 | ±0.5% | 22 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
0-46 | 0-20 | ±0.5% | 30 psi @ 70° F | 3 1/4" | 5 1/4" | 32° | 140° | 60 | 12-36V DC | Closed Tank, Open Tank | Wire Leads | IP68 | 0000000 | 000000 |
Float Liquid-Level Transmitters
Easy to set up and use, these transmitters measure liquid levels using a standard float gauge. They continuously send measurements to a receiving device, such as a programmable logic controller, so you can monitor status and manage components in your system.
For technical drawings and 3-D models, click on a part number.
Pipe | Overall | Temp. Range, °F | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tank Depth | Size | Thread Type | Gender | Max. Pressure | Dia. | Lg. | Min. | Max. | Cable Lg., ft. | Input Voltage | For Container Type | Electrical Connection Type | Specifications Met | Each | |
4-20mA Output Current | |||||||||||||||
Polypropylene Plastic Float | |||||||||||||||
19" | 1 1/2 | NPT | Male | 100 psi @ 70° F | 1 7/8" | 21" | -40° | 220° | 2 | 12-30V DC | Closed Tank, Open Tank | Wire Leads | CE Marked, C-UL Recognized Component, UL Recognized Component | 0000000 | 0000000 |
316 Stainless Steel Float | |||||||||||||||
24" | 2 | NPT | Male | 200 psi @ 70° F | 2 3/8" | 27" | -40° | 220° | 2 | 12-30V DC | Closed Tank, Open Tank | Wire Leads | CE Marked, C-UL Recognized Component, UL Recognized Component | 0000000 | 000000 |
Noncontact Liquid-Level Transmitters
Using high-frequency soundwaves, these transmitters measure the levels of corrosive, dirty, or sticky liquids without coming into contact with them. They’ll continuously send measurements, so you can monitor status and manage components in your system. Mount at the top of your tank. There should be no tank walls, agitators, or other objects in the path of the soundwaves.
Ultrasonic transmitters are often used to measure water, wastewater, chemicals, and oil but won’t work on vapors, foam, and other media that’s difficult to measure. The included fob allows you to connect your transmitter to your computer, where you'll download software that guides you through the setup process to make sure you get accurate readings. Ultrasonic transmitters with a button interface can be set up and calibrated without the fob. Transmitters with a switch can also signal your controller to turn components on or off when they reach a set level.
Radar transmitters are best for liquids that are tricky to measure because they work even if there’s condensation, foam, or other difficult conditions. They also measure the level of liquids with solids and small solids. In addition to the traditional 4-20 mA output, these transmitters can also send measurements to your Android smartphone or tablet using Bluetooth. There’s an app you can use to set up your transmitter and calibrate it for your system.
NEMA 6P rated transmitters protect against dust, weather, washdowns, corrosion, and submersion. IP68 rated transmitters seal out dust and water from temporary submersion.
For technical drawings and 3-D models, click on a part number.
Overall | Temp. Range, °F | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | For Liquid Level | Max. Pressure | Dia. | Lg. | Min. | Max. | Cable Lg., ft. | Input Voltage | Electrical Connection Type | Environmental Rating | Includes | Features | Each | |
NPT Male Pipe Connection | ||||||||||||||
0-5V DC/0-10V DC Output Signal | ||||||||||||||
1 | 0ft.-4ft. | 30 psi @ 70° F | 2" | 3 1/4" | -30° | 140° | 4 | 12-24V DC | Wire Leads | NEMA 6P | USB Configuration Fob | __ | 0000000 | 0000000 |
4-20mA Output Signal | ||||||||||||||
2 | 0ft.-19 1/2ft. | 30 psi @ 70° F | 4 3/8" | 7" | -30° | 140° | __ | 14-28V DC | Quick-Disconnect Terminals | IP68, NEMA 6P | USB Configuration Fob | Button Interface | 0000000 | 000000 |
3 | 0ft.-39ft. | 30 psi @ 70° F | 4 5/8" | 7" | -30° | 140° | __ | 14-28V DC | Quick-Disconnect Terminals | IP68, NEMA 6P | USB Configuration Fob | Button Interface | 0000000 | 00000000 |
4-20mA Output Signal with Switch | ||||||||||||||
1 | 0ft.-4ft. | 30 psi @ 70° F | 2" | 3 1/4" | -30° | 140° | 4 | 24V DC | Wire Leads | NEMA 6P | USB Configuration Fob | __ | 0000000 | 000000 |
1 | 0ft.-9 3/4ft. | 30 psi @ 70° F | 3" | 4 3/4" | -30° | 140° | 4 | 24V DC | Wire Leads | NEMA 6P | USB Configuration Fob | __ | 0000000 | 000000 |
2 | 1 1/2"-4 3/4ft. | 30 psi @ 70° F | 2 3/4" | 4" | -30° | 140° | 4 | 14-28V DC | Wire Leads | IP68, NEMA 6P | USB Configuration Fob | __ | 0000000 | 000000 |
2 | 4"-9 3/4ft. | 30 psi @ 70° F | 2 3/4" | 4" | -30° | 140° | 4 | 14-28V DC | Wire Leads | IP68, NEMA 6P | USB Configuration Fob | __ | 0000000 | 000000 |
Overall | Temp. Range, °F | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | For Liquid Level, ft. | Max. Pressure | Dia. | Lg. | Min. | Max. | Cable Lg., ft. | Input Voltage | Electrical Connection Type | Environmental Rating | Data Connection Type | Communication Protocol | Each | |
NPT Male Pipe Connection | ||||||||||||||
4-20mA Output Signal | ||||||||||||||
1 1/2 | 0-45 | 40 psi @ 70° F | 4" | 4 1/4" | -40° | 175° | 15 | 18-36V DC | Wire Leads | IP68 | Bluetooth | HART | 0000000 | 000000000 |
Connection Type | Each | |
4-pin USB Type A (Male) | 0000000 | 000000 |