About Choosing a Heater
More
Portable Large-Space Gas Heaters
Built for big jobs, these are powerful space heaters.
All have a safety shut-off that cuts the gas supply if the flame goes out.
Propane heaters have a regulator with a NGO connection (the same connection between your gas grill and propane tank).
Heaters with a built-in thermostat allow you to control the temperature. On heaters controlled with a knob, turn the knob to adjust heat output.
Style A heaters use convection to circulate warm air. They have a pilot light ignition and do not require electricity.
Style B heaters have an electronic spark ignition and are good for drafty areas where a pilot light could be extinguished.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Inlet Thread Type | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Includes | Each | |
Propane Heaters with Knob | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | Not Rated | 20 | 4 | NGO | __ | __ | 16" | 19" | 22" | Steel | 20-ft. Hose | 0000000 | 0000000 |
A | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | Not Rated | 100 | 9.5 | NGO | __ | __ | 19" | 15" | 28" | Steel | 20-ft. Hose | 0000000 | 000000 |
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 125,000 | 16,660 cu. ft. @ 10° F 8,330 cu. ft. @ 20° F 5,550 cu. ft. @ 30° F 4,160 cu. ft. @ 40° F | 400 | 100 | 6 | NGO | 0.7 | 10" | 16" | 12" | 26" | Steel | 15-ft. Hose | 0000000 | 000000 |
Propane Heaters with Thermostat (40° to 105° F) | |||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 170,000 | 22,660 cu. ft. @ 10° F 11,330 cu. ft. @ 20° F 7,550 cu. ft. @ 30° F 5,660 cu. ft. @ 40° F | 625 | 100 | 8 | NGO | 2.1 | 4" | 16" | 9" | 24" | Steel | 10-ft. Hose | 0000000 | 000000 |
B | 400,000 | 53,330 cu. ft. @ 10° F 26,660 cu. ft. @ 20° F 17,770 cu. ft. @ 30° F 13,330 cu. ft. @ 40° F | 1,580 | 500 | 18.5 | NGO | 1.5 | 4" | 22" | 13" | 35" | Steel | 10-ft. Hose | 0000000 | 000000 |
Ceiling-Mount Large-Space Gas Heaters
Heat shops, garages, warehouses, and other large spaces with these heaters that can be suspended from the ceiling. They have an electronic spark ignition that makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Note: Heaters need to be vented to the outdoors. Vent pipe is not included.
Use with low-voltage thermostat (sold separately).
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Mounting Brackets | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Current, A | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Required Vent Dia. | Includes | Each | Pair | |||
Propane Heaters | |||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase (Wire Leads) | |||||||||||||||||
A | 36,000 | 4,800 cu. ft. @ 10° F 2,400 cu. ft. @ 20° F 1,600 cu. ft. @ 30° F 1,200 cu. ft. @ 40° F | 720 | 1/2 | NPT | Female | 3.7 | 10 | 13" | 27" | 22" | 3" | Mounting Bracket | 00000000 | 000000000 | 000000 | 00 |
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | 1,490 | 1/2 | NPT | Female | 4.7 | 12 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 0000000 |
A | 100,000 | 13,330 cu. ft. @ 10° F 6,660 cu. ft. @ 20° F 4,440 cu. ft. @ 30° F 3,330 cu. ft. @ 40° F | 1,980 | 1/2 | NPT | Female | 4.2 | 16 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
B | 143,000 | 19,130 cu. ft. @ 10° F 9,560 cu. ft. @ 20° F 6,370 cu. ft. @ 30° F 4,780 cu. ft. @ 40° F | 2,720 | 1/2 | NPT | Female | 2.5 | 14 | 26" | 43" | 33" | 4" | __ | 00000000 | 00000000 | 000000 | 00 |
C | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | 3,700 | 1/2 | NPT | Female | 7.7 | 19 | 41" | 26" | 35" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
C | 320,000 | 42,660 cu. ft. @ 10° F 21,330 cu. ft. @ 20° F 14,220 cu. ft. @ 30° F 10,660 cu. ft. @ 40° F | 5,440 | 3/4 | NPT | Female | 11.1 | 19 | 41" | 40" | 39" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
Low-Voltage Thermostat | 00000000 | Each | 000000 |
Direct Short-Range Gas Heaters
Built for outdoor use, these heaters warm people at worksites and other cold spots without access to electricity. Connect heaters to a propane tank and light with a match. They have a regulator with a NGO connection (the same connection between your gas grill and propane tank). All have a safety shut-off that cuts the gas supply if the flame goes out.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Burners | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Inlet Thread Type | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Each | |
Propane Heaters | ||||||||||||
External Lighter Ignition | ||||||||||||
1 | 15,000 | 440 sq. ft. @ 10° F 220 sq. ft. @ 20° F 150 sq. ft. @ 30° F 110 sq. ft. @ 40° F | 20 | 1 | NGO | 13" | 10" | 8" | Steel | Yes | 000000 | 000000 |
2 | 30,000 | 880 sq. ft. @ 10° F 440 sq. ft. @ 20° F 290 sq. ft. @ 30° F 220 sq. ft. @ 40° F | 20 | 1.5 | NGO | 16" | 17" | 7" | Steel | Yes | 000000 | 000000 |
3 | 45,000 | 1,320 sq. ft. @ 10° F 660 sq. ft. @ 20° F 450 sq. ft. @ 30° F 330 sq. ft. @ 40° F | 20 | 2 | NGO | 12" | 27" | 6" | Steel | Yes | 0000000 | 000000 |
Direct Long-Range Ceiling-Mount Gas Heaters
Our most powerful ceiling-mount direct heaters, these warm people in large spaces, such as warehouses. All have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Heaters with two burners allow for greater control over how much heat is generated—use one or both burners depending on your needs.
Heaters with a pilot light ignition do not require electricity. Heaters with an electronic spark ignition are good for drafty areas where a pilot light could be extinguished.
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 2 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 000000000 | 000000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 5 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 000000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Pilot Burners | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 2 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 00000000 | 000000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 5 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
Direct Long-Range Portable Gas Heaters
Place at large worksites and other well-ventilated areas. These heaters have a safety shut-off that cuts the gas supply if the flame goes out.
Propane heaters with a regulator have a NGO connection (the same connection between your gas grill and propane tank).
Barrier ring guard kits keep you from accidentally bumping into heaters. They are often used in areas with high foot traffic.
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Replacement Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Dia. | Housing Material | For Use Outdoors | Includes | Each | Each | ||
Pilot Light Ignition | |||||||||||||||||
35,000 | 1,020 sq. ft. @ 10° F 510 sq. ft. @ 20° F 340 sq. ft. @ 30° F 260 sq. ft. @ 40° F | 20 | 2 | __ | NGO | __ | 35" | 10" | 13" | __ | Steel | Yes | 20-ft. Hose with Regulator | 000000 | 0000000 | 0000000 | 000000 |
125,000 | 3,660 sq. ft. @ 10° F 1,830 sq. ft. @ 20° F 1,220 sq. ft. @ 30° F 910 sq. ft. @ 40° F | 40 | 6 | __ | NGO | __ | 35" | 15" | 15" | __ | Steel | Yes | 20-ft. Hose with Regulator | 0000000 | 000000 | 0000000 | 00000 |
200,000 | 5,860 cu. ft. @ 10° F 2,930 cu. ft. @ 20° F 1,950 cu. ft. @ 30° F 1,460 cu. ft. @ 40° F | 100 | 9 | 1/2 | NPT | Female | 50" | __ | __ | 18" | Steel | No | __ | 0000000 | 000000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
200,000 212,000 | 0000000 | 0000000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
Direct Long-Range Wall-Mount Gas Heaters
Use these powerful heaters to warm people in large spaces, such as warehouses. They have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption | Pipe Size | Thread Type | Gender | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temperature Setting, °F | Each | |
Propane Heaters | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
22,000 | 640 sq. ft. @ 10° F 320 sq. ft. @ 20° F 210 sq. ft. @ 30° F 160 sq. ft. @ 40° F | 1 | 1 lbs./hr. | 1/2 | NPT | Female | 9 | 7" | 30" | 13" | Steel | No | 35° to 75° | 00000000 | 0000000 |