About Choosing a Heater
More
Portable Large-Space Gas Heaters
Built for big jobs, these are powerful space heaters.
All have a safety shut-off that cuts the gas supply if the flame goes out.
Heaters with a built-in thermostat allow you to control the temperature. On heaters controlled with a knob, turn the knob to adjust heat output.
Style A heaters use convection to circulate warm air. They have a pilot light ignition and do not require electricity.
Style B heaters have an electronic spark ignition and are good for drafty areas where a pilot light could be extinguished.
Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, cfh | Inlet Pipe Size | Inlet Thread Type | Inlet Gender | Tube Connection Type | Thread Type | For Tube OD | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Each | |
Natural Gas Heaters with Knob | ||||||||||||||||||
Pilot Light Ignition | ||||||||||||||||||
A | 100,000 | 13,300 cu. ft. @ 10° F 6,600 cu. ft. @ 20° F 4,400 cu. ft. @ 30° F 3,300 cu. ft. @ 40° F | Not Rated | 100 | __ | __ | Male | 37° Flared | UN/UNF (JIC) | 1/2" | __ | __ | 19" | 16" | 16" | Steel | 0000000 | 0000000 |
Natural Gas Heaters with Thermostat (40° to 105° F) | ||||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | ||||||||||||||||||
B | 155,000 | 20,660 cu. ft. @ 10° F 10,330 cu. ft. @ 20° F 6,880 cu. ft. @ 30° F 5,160 cu. ft. @ 40° F | 625 | 155 | 1/2 | NPT | Female | __ | __ | __ | 2.1 | 4" | 16" | 9" | 24" | Steel | 0000000 | 000000 |
Ceiling-Mount Large-Space Gas Heaters
Heat shops, garages, warehouses, and other large spaces with these heaters that can be suspended from the ceiling. They have an electronic spark ignition that makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Note: Heaters need to be vented to the outdoors. Vent pipe is not included.
Use with low-voltage thermostat (sold separately).
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Mounting Brackets | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Current, A | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Required Vent Dia. | Includes | Each | Pair | |||
Natural Gas Heaters | |||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase (Wire Leads) | |||||||||||||||||
A | 36,000 | 4,800 cu. ft. @ 10° F 2,400 cu. ft. @ 20° F 1,600 cu. ft. @ 30° F 1,200 cu. ft. @ 40° F | 720 | 1/2 | NPT | Female | 3.7 | 10 | 13" | 27" | 22" | 3" | Mounting Bracket | 00000000 | 000000000 | 000000 | 00 |
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | 1,490 | 1/2 | NPT | Female | 4.7 | 12 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 0000000 |
A | 100,000 | 13,330 cu. ft. @ 10° F 6,660 cu. ft. @ 20° F 4,440 cu. ft. @ 30° F 3,330 cu. ft. @ 40° F | 1,980 | 1/2 | NPT | Female | 4.2 | 16 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
B | 143,000 | 19,130 cu. ft. @ 10° F 9,560 cu. ft. @ 20° F 6,370 cu. ft. @ 30° F 4,780 cu. ft. @ 40° F | 2,720 | 1/2 | NPT | Female | 2.5 | 14 | 26" | 43" | 33" | 4" | __ | 00000000 | 00000000 | 000000 | 00 |
C | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | 3,700 | 1/2 | NPT | Female | 7.7 | 19 | 41" | 26" | 35" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
C | 320,000 | 42,660 cu. ft. @ 10° F 21,330 cu. ft. @ 20° F 14,220 cu. ft. @ 30° F 10,660 cu. ft. @ 40° F | 5,440 | 3/4 | NPT | Female | 11.1 | 19 | 41" | 40" | 39" | 6" | __ | 00000000 | 00000000 | 000000 | 00 |
Low-Voltage Thermostat | 00000000 | Each | 000000 |
Direct Long-Range Ceiling-Mount Gas Heaters
Our most powerful ceiling-mount direct heaters, these warm people in large spaces, such as warehouses. All have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Heaters with two burners allow for greater control over how much heat is generated—use one or both burners depending on your needs.
Heaters with a pilot light ignition do not require electricity. Heaters with an electronic spark ignition are good for drafty areas where a pilot light could be extinguished.
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 40 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 000000000 | 000000 |
60,000 | 2,050 sq. ft. @ 10° F 680 sq. ft. @ 20° F 510 sq. ft. @ 30° F 510 sq. ft. @ 40° F | 1 | 60 | 3/4 | NPT | Female | 15 | 12" | 46" | 20" | Steel | No | 50° to 90° | 00000000 | 000000 | 000000000 | 00000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 100 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 000000000 | 00000 |
120,000 | 4,100 sq. ft. @ 10° F 1,370 sq. ft. @ 20° F 1,020 sq. ft. @ 30° F 1,020 sq. ft. @ 40° F | 2 | 120 | 3/4 | NPT | Female | 36 | 11" | 83" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 000000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Pilot Burners | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 40 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 00000000 | 000000 |
60,000 | 2,050 sq. ft. @ 10° F 680 sq. ft. @ 20° F 510 sq. ft. @ 30° F 510 sq. ft. @ 40° F | 1 | 60 | 3/4 | NPT | Female | 15 | 12" | 46" | 20" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 100 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
120,000 | 4,100 sq. ft. @ 10° F 1,370 sq. ft. @ 20° F 1,020 sq. ft. @ 30° F 1,020 sq. ft. @ 40° F | 2 | 120 | 3/4 | NPT | Female | 36 | 11" | 83" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 00000000 | 00000 |
Direct Long-Range Wall-Mount Gas Heaters
Use these powerful heaters to warm people in large spaces, such as warehouses. They have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption | Pipe Size | Thread Type | Gender | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temperature Setting, °F | Each | |
Natural Gas Heaters | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
22,000 | 640 sq. ft. @ 10° F 320 sq. ft. @ 20° F 210 sq. ft. @ 30° F 160 sq. ft. @ 40° F | 1 | 25 cfh | 1/2 | NPT | Female | 9 | 7" | 30" | 13" | Steel | No | 35° to 75° | 00000000 | 0000000 |
Direct Long-Range Portable Gas Heaters
Place at large worksites and other well-ventilated areas. These heaters have a safety shut-off that cuts the gas supply if the flame goes out.
Barrier ring guard kits keep you from accidentally bumping into heaters. They are often used in areas with high foot traffic.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Replacement Thermocouples | |||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Dia. | Housing Material | For Use Outdoors | Each | Each | ||
Pilot Light Ignition | |||||||||||||||
125,000 | 3,660 sq. ft. @ 10° F 1,830 sq. ft. @ 20° F 1,220 sq. ft. @ 30° F 910 sq. ft. @ 40° F | 125 | 1/2 | NPT | Female | 35" | 15" | 15" | __ | Steel | Yes | 0000000 | 0000000 | 0000000 | 000000 |
212,000 | 6,210 sq. ft. @ 10° F 3,100 sq. ft. @ 20° F 2,070 sq. ft. @ 30° F 1,550 sq. ft. @ 40° F | 215 | 1/2 | NPT | Female | 50" | __ | __ | 18" | Steel | No | 0000000 | 000000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
200,000 212,000 | 0000000 | 0000000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 000000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |
For Heat Output, Btu/hr. | Each | |
125,000 | 0000000 | 00000 |