About Choosing a Heater
More
Portable Large-Space Gas Heaters
Built for big jobs, these are powerful space heaters.
All have a safety shut-off that cuts the gas supply if the flame goes out.
Propane heaters have a regulator with a NGO connection (the same connection between your gas grill and propane tank).
Heaters with a built-in thermostat allow you to control the temperature. On heaters controlled with a knob, turn the knob to adjust heat output.
Style A heaters use convection to circulate warm air. They have a pilot light ignition and do not require electricity.
Style B heaters have an electronic spark ignition and are good for drafty areas where a pilot light could be extinguished.
Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, cfh | Inlet Pipe Size | Inlet Thread Type | Inlet Gender | Tube Connection Type | Thread Type | For Tube OD | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Each | |
Natural Gas Heaters with Knob | ||||||||||||||||||
Pilot Light Ignition | ||||||||||||||||||
A | 100,000 | 13,300 cu. ft. @ 10° F 6,600 cu. ft. @ 20° F 4,400 cu. ft. @ 30° F 3,300 cu. ft. @ 40° F | Not Rated | 100 | __ | __ | Male | 37° Flared | UN/UNF (JIC) | 1/2" | __ | __ | 19" | 16" | 16" | Steel | 0000000 | 0000000 |
Natural Gas Heaters with Thermostat (40° to 105° F) | ||||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | ||||||||||||||||||
B | 155,000 | 20,660 cu. ft. @ 10° F 10,330 cu. ft. @ 20° F 6,880 cu. ft. @ 30° F 5,160 cu. ft. @ 40° F | 625 | 155 | 1/2 | NPT | Female | __ | __ | __ | 2.1 | 4" | 16" | 9" | 24" | Steel | 0000000 | 000000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Required Propane Tank Size, lbs. | Max. Fuel Consumption, lbs./hr. | Inlet Thread Type | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Includes | Each | |
Propane Heaters with Knob | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | Not Rated | 20 | 4 | NGO | __ | __ | 16" | 19" | 22" | Steel | 20-ft. Hose | 0000000 | 0000000 |
A | 200,000 | 26,660 cu. ft. @ 10° F 13,330 cu. ft. @ 20° F 8,880 cu. ft. @ 30° F 6,660 cu. ft. @ 40° F | Not Rated | 100 | 9.5 | NGO | __ | __ | 19" | 15" | 28" | Steel | 20-ft. Hose | 0000000 | 000000 |
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 125,000 | 16,660 cu. ft. @ 10° F 8,330 cu. ft. @ 20° F 5,550 cu. ft. @ 30° F 4,160 cu. ft. @ 40° F | 400 | 100 | 6 | NGO | 0.7 | 10" | 16" | 12" | 26" | Steel | 15-ft. Hose | 0000000 | 000000 |
Propane Heaters with Thermostat (40° to 105° F) | |||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
B | 170,000 | 22,660 cu. ft. @ 10° F 11,330 cu. ft. @ 20° F 7,550 cu. ft. @ 30° F 5,660 cu. ft. @ 40° F | 625 | 100 | 8 | NGO | 2.1 | 4" | 16" | 9" | 24" | Steel | 10-ft. Hose | 0000000 | 000000 |
B | 400,000 | 53,330 cu. ft. @ 10° F 26,660 cu. ft. @ 20° F 17,770 cu. ft. @ 30° F 13,330 cu. ft. @ 40° F | 1,580 | 500 | 18.5 | NGO | 1.5 | 4" | 22" | 13" | 35" | Steel | 10-ft. Hose | 0000000 | 000000 |
Mobile Large-Space Kerosene and Diesel Heaters
Roll these powerful space heaters to where you need heat for big jobs. All have a built-in thermostat.
The electronic spark ignition makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Air Filters | ||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, gph | Fuel Tank Capacity, gal. | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Temperature Setting, °F | Each | Each | ||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
125,000 | 16,660 cu. ft. @ 10° F 8,330 cu. ft. @ 20° F 5,550 cu. ft. @ 30° F 4,160 cu. ft. @ 40° F | 520 | 1 | 10 | 2.5 | 4" | 25" | 23" | 38" | Steel | 40° to 105° | 000000 | 0000000 | 0000000 | 000000 |
175,000 | 23,330 cu. ft. @ 10° F 11,660 cu. ft. @ 20° F 7,770 cu. ft. @ 30° F 5,830 cu. ft. @ 40° F | 600 | 1.3 | 13 | 3.2 | 4" | 27" | 24" | 44" | Steel | 40° to 105° | 0000000 | 000000 | 0000000 | 00000 |
650,000 | 86,660 cu. ft. @ 10° F 43,330 cu. ft. @ 20° F 28,880 cu. ft. @ 30° F 21,660 cu. ft. @ 40° F | 3,600 | 5 | 50 | 7.1 | 4" | 49" | 31" | 70" | Steel | 40° to 105° | 0000000 | 00000000 | 000000 | 00 |
Ceiling-Mount Large-Space Gas Heaters
Heat shops, garages, warehouses, and other large spaces with these heaters that can be suspended from the ceiling. They have an electronic spark ignition that makes them good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Note: Heaters need to be vented to the outdoors. Vent pipe is not included.
Use with low-voltage thermostat (sold separately).
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Overall | Mounting Brackets | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Current, A | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Required Vent Dia. | Includes | Each | Pair | |||
Natural Gas Heaters | |||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase (Wire Leads) | |||||||||||||||||
A | 36,000 | 4,800 cu. ft. @ 10° F 2,400 cu. ft. @ 20° F 1,600 cu. ft. @ 30° F 1,200 cu. ft. @ 40° F | 720 | 1/2 | NPT | Female | 3.7 | 10 | 13" | 27" | 22" | 3" | Mounting Bracket | 00000000 | 000000000 | 000000 | 00 |
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | 1,490 | 1/2 | NPT | Female | 4.7 | 12 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 0000000 |
A | 100,000 | 13,330 cu. ft. @ 10° F 6,660 cu. ft. @ 20° F 4,440 cu. ft. @ 30° F 3,330 cu. ft. @ 40° F | 1,980 | 1/2 | NPT | Female | 4.2 | 16 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
B | 143,000 | 19,130 cu. ft. @ 10° F 9,560 cu. ft. @ 20° F 6,370 cu. ft. @ 30° F 4,780 cu. ft. @ 40° F | 2,720 | 1/2 | NPT | Female | 2.5 | 14 | 26" | 43" | 33" | 4" | __ | 00000000 | 00000000 | 000000 | 00 |
Propane Heaters | |||||||||||||||||
Electronic Spark Ignition—120V AC, Single Phase (Wire Leads) | |||||||||||||||||
A | 36,000 | 4,800 cu. ft. @ 10° F 2,400 cu. ft. @ 20° F 1,600 cu. ft. @ 30° F 1,200 cu. ft. @ 40° F | 720 | 1/2 | NPT | Female | 3.7 | 10 | 13" | 27" | 22" | 3" | Mounting Bracket | 00000000 | 00000000 | 000000 | 00 |
A | 80,000 | 10,660 cu. ft. @ 10° F 5,330 cu. ft. @ 20° F 3,550 cu. ft. @ 30° F 2,660 cu. ft. @ 40° F | 1,490 | 1/2 | NPT | Female | 4.7 | 12 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
A | 100,000 | 13,330 cu. ft. @ 10° F 6,660 cu. ft. @ 20° F 4,440 cu. ft. @ 30° F 3,330 cu. ft. @ 40° F | 1,980 | 1/2 | NPT | Female | 4.2 | 16 | 21" | 36" | 31" | 4" | __ | 00000000 | 00000000 | 0000000 | 000000 |
B | 143,000 | 19,130 cu. ft. @ 10° F 9,560 cu. ft. @ 20° F 6,370 cu. ft. @ 30° F 4,780 cu. ft. @ 40° F | 2,720 | 1/2 | NPT | Female | 2.5 | 14 | 26" | 43" | 33" | 4" | __ | 00000000 | 00000000 | 000000 | 00 |
Low-Voltage Thermostat | 00000000 | Each | 000000 |
Portable Large-Space Kerosene and Diesel Heaters
Built for big jobs, this is a powerful space heater. It has a built-in thermostat.
The electronic spark ignition makes it good for drafty areas where a pilot light could be extinguished. The safety shut-off cuts the gas supply if the flame goes out.
Heaters | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Air Filters | ||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Max. Fuel Consumption, gph | Fuel Tank Capacity, gal. | Current, A | Cord Lg. | Ht. | Wd. | Dp. | Housing Material | Temperature Setting, °F | Each | Each | ||
Electronic Spark Ignition—120V AC, Single Phase, Three-Prong Plug (NEMA 5-15) | |||||||||||||||
75,000 | 10,000 cu. ft. @ 10° F 5,000 cu. ft. @ 20° F 3,330 cu. ft. @ 30° F 2,500 cu. ft. @ 40° F | 265 | 0.6 | 5 | 1.6 | 4" | 17" | 12" | 32" | Steel | 40° to 105° | 000000 | 0000000 | 0000000 | 000000 |
Horizontal Flow Large-Space Steam and Water Heaters
Evenly warm a large space using steam and water from your existing boilers. Heat output is based on steam at 2 psi.
Control with a line-voltage thermostat (not included).
Inlet | Outlet | Steam | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temperature, °F | Current, A | Ht. | Wd. | Dp. | Housing Material | Each | |
120V AC, Single Phase—Wire Leads | |||||||||||||||||
Ceiling Mount | |||||||||||||||||
24,000 | 3,200 cu. ft. @ 10° F 1,600 cu. ft. @ 20° F 1,060 cu. ft. @ 30° F 800 cu. ft. @ 40° F | 370 | 3/4 | NPT | Female | 3/4 | NPT | Female | 150 | 375° | 1.6 | 13" | 13" | 11" | Steel | 0000000 | 0000000 |
47,000 | 6,260 cu. ft. @ 10° F 3,130 cu. ft. @ 20° F 2,080 cu. ft. @ 30° F 1,560 cu. ft. @ 40° F | 730 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 2.2 | 17" | 18" | 15" | Steel | 0000000 | 00000000 |
63,000 | 8,400 cu. ft. @ 10° F 4,200 cu. ft. @ 20° F 2,800 cu. ft. @ 30° F 2,100 cu. ft. @ 40° F | 1,120 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 2.2 | 21" | 22" | 17" | Steel | 0000000 | 00000000 |
86,000 | 11,460 cu. ft. @ 10° F 5,730 cu. ft. @ 20° F 3,820 cu. ft. @ 30° F 2,860 cu. ft. @ 40° F | 1,340 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 2.3 | 21" | 22" | 17" | Steel | 0000000 | 00000000 |
121,000 | 16,130 cu. ft. @ 10° F 8,060 cu. ft. @ 20° F 5,370 cu. ft. @ 30° F 4,030 cu. ft. @ 40° F | 1,775 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 2.8 | 25" | 26" | 17" | Steel | 0000000 | 00000000 |
165,000 | 22,000 cu. ft. @ 10° F 11,000 cu. ft. @ 20° F 7,330 cu. ft. @ 30° F 5,500 cu. ft. @ 40° F | 3,240 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 5.4 | 31" | 31" | 18" | Steel | 0000000 | 00000000 |
193,000 | 25,730 cu. ft. @ 10° F 12,860 cu. ft. @ 20° F 8,570 cu. ft. @ 30° F 6,430 cu. ft. @ 40° F | 2,900 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 5.4 | 31" | 31" | 18" | Steel | 0000000 | 00000000 |
258,000 | 34,400 cu. ft. @ 10° F 17,200 cu. ft. @ 20° F 11,460 cu. ft. @ 30° F 8,600 cu. ft. @ 40° F | 4,560 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 7.5 | 39" | 39" | 23" | Steel | 0000000 | 00000000 |
340,000 | 45,330 cu. ft. @ 10° F 22,660 cu. ft. @ 20° F 15,110 cu. ft. @ 30° F 11,330 cu. ft. @ 40° F | 5,130 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 7.5 | 39" | 45" | 23" | Steel | 0000000 | 00000000 |
240V AC/460V AC, Three Phase—Wire Leads | |||||||||||||||||
Ceiling Mount | |||||||||||||||||
340,000 | 45,330 cu. ft. @ 10° F 22,660 cu. ft. @ 20° F 15,110 cu. ft. @ 30° F 11,330 cu. ft. @ 40° F | 5,130 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 150 | 375° | 7.5 | 39" | 45" | 23" | Steel | 000000 | 00000000 |
Vertical Flow Large-Space Steam and Water Heaters
Focus warm air in a specific spot using steam and water from your existing boilers. Heat output is based on steam at 2 psi.
Control with a line-voltage thermostat (not included).
Inlet | Outlet | Steam | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temperature, °F | Current, A | Ht. | Dia. | Housing Material | Each | |
120V AC, Single Phase—Wire Leads | ||||||||||||||||
Ceiling Mount | ||||||||||||||||
59,000 | 7,860 cu. ft. @ 10° F 3,930 cu. ft. @ 20° F 2,620 cu. ft. @ 30° F 1,960 cu. ft. @ 40° F | 1,155 | 1 1/4 | NPT | Male | 1 1/4 | NPT | Male | 30 | 375° | 1.9 | 10" | 25" | Steel | 000000 | 000000000 |
95,000 | 12,660 cu. ft. @ 10° F 6,330 cu. ft. @ 20° F 4,220 cu. ft. @ 30° F 3,160 cu. ft. @ 40° F | 1,665 | 1 1/4 | NPT | Male | 1 1/4 | NPT | Male | 30 | 375° | 2.4 | 11" | 25" | Steel | 000000 | 00000000 |
139,000 | 18,530 cu. ft. @ 10° F 9,260 cu. ft. @ 20° F 6,170 cu. ft. @ 30° F 4,630 cu. ft. @ 40° F | 2,660 | 1 1/2 | NPT | Male | 1 | NPT | Male | 30 | 375° | 2.8 | 10" | 35" | Steel | 000000 | 00000000 |
161,000 | 21,460 cu. ft. @ 10° F 10,730 cu. ft. @ 20° F 7,150 cu. ft. @ 30° F 5,360 cu. ft. @ 40° F | 2,940 | 1 1/2 | NPT | Male | 1 | NPT | Male | 30 | 375° | 5.4 | 12" | 35" | Steel | 000000 | 00000000 |
193,000 | 25,730 cu. ft. @ 10° F 12,860 cu. ft. @ 20° F 8,570 cu. ft. @ 30° F 6,430 cu. ft. @ 40° F | 3,500 | 1 1/2 | NPT | Male | 1 | NPT | Male | 30 | 375° | 5.4 | 13" | 35" | Steel | 000000 | 00000000 |
247,000 | 32,930 cu. ft. @ 10° F 16,460 cu. ft. @ 20° F 10,970 cu. ft. @ 30° F 8,230 cu. ft. @ 40° F | 4,820 | 2 | NPT | Male | 1 1/4 | NPT | Male | 30 | 375° | 7.5 | 16" | 35" | Steel | 000000 | 00000000 |
279,000 | 37,200 cu. ft. @ 10° F 18,600 cu. ft. @ 20° F 12,400 cu. ft. @ 30° F 9,300 cu. ft. @ 40° F | 5,460 | 2 | NPT | Male | 1 1/4 | NPT | Male | 30 | 375° | 7.5 | 18" | 35" | Steel | 000000 | 00000000 |
240V AC, 460V AC, Three Phase—Wire Leads | ||||||||||||||||
Ceiling Mount | ||||||||||||||||
385,000 | 51,330 cu. ft. @ 10° F 25,660 cu. ft. @ 20° F 17,110 cu. ft. @ 30° F 12,830 cu. ft. @ 40° F | 7,680 | 2 1/2 | NPT | Male | 1 1/2 | NPT | Male | 30 | 375° | 4 | 18" | 44" | Steel | 0000000 | 00000000 |
500,000 | 66,660 cu. ft. @ 10° F 33,330 cu. ft. @ 20° F 22,220 cu. ft. @ 30° F 16,660 cu. ft. @ 40° F | 10,390 | 2 1/2 | NPT | Male | 1 1/2 | NPT | Male | 30 | 375° | 5.2 | 23" | 44" | Steel | 0000000 | 00000000 |
Horizontal Flow Hazardous Location Large-Space Steam and Water Heaters
Evenly warm a large space with steam and water from your existing boilers. Use indoors where flammable gases, vapors, dust, and fibers are present—they meet Class I, Divisions 1 and 2, Group D; Class II, Divisions 1 and 2, Groups F and G; and Class III, Divisions 1 and 2. Heat output is based on steam at 2 psi.
Control with a line-voltage thermostat (not included).
Inlet | Outlet | Steam | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temperature, °F | Current, A | Ht. | Wd. | Dp. | Housing Material | Each | |
120V AC, Single Phase—Wire Leads | |||||||||||||||||
Ceiling Mount | |||||||||||||||||
24,000 | 3,200 cu. ft. @ 10° F 1,600 cu. ft. @ 20° F 1,060 cu. ft. @ 30° F 800 cu. ft. @ 40° F | 370 | 3/4 | NPT | Female | 3/4 | NPT | Female | 85 | 325° | 3.1 | 13" | 13" | 19" | Steel | 0000000 | 000000000 |
47,000 | 6,260 cu. ft. @ 10° F 3,130 cu. ft. @ 20° F 2,080 cu. ft. @ 30° F 1,560 cu. ft. @ 40° F | 730 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 3.1 | 17" | 18" | 21" | Steel | 0000000 | 00000000 |
63,000 | 8,400 cu. ft. @ 10° F 4,200 cu. ft. @ 20° F 2,800 cu. ft. @ 30° F 2,100 cu. ft. @ 40° F | 1,120 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 3.1 | 21" | 22" | 21" | Steel | 0000000 | 00000000 |
86,000 | 11,460 cu. ft. @ 10° F 5,730 cu. ft. @ 20° F 3,820 cu. ft. @ 30° F 2,860 cu. ft. @ 40° F | 1,340 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 3.1 | 21" | 22" | 21" | Steel | 0000000 | 00000000 |
121,000 | 16,130 cu. ft. @ 10° F 8,060 cu. ft. @ 20° F 5,370 cu. ft. @ 30° F 4,030 cu. ft. @ 40° F | 1,775 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 4.1 | 25" | 26" | 23" | Steel | 0000000 | 00000000 |
165,000 | 22,000 cu. ft. @ 10° F 11,000 cu. ft. @ 20° F 7,330 cu. ft. @ 30° F 5,500 cu. ft. @ 40° F | 3,240 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 7.2 | 31" | 31" | 25" | Steel | 0000000 | 00000000 |
193,000 | 25,730 cu. ft. @ 10° F 12,860 cu. ft. @ 20° F 8,570 cu. ft. @ 30° F 6,430 cu. ft. @ 40° F | 2,900 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 7.2 | 31" | 31" | 25" | Steel | 0000000 | 00000000 |
258,000 | 34,400 cu. ft. @ 10° F 17,200 cu. ft. @ 20° F 11,460 cu. ft. @ 30° F 8,600 cu. ft. @ 40° F | 4,560 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 5.8 | 39" | 39" | 28" | Steel | 0000000 | 00000000 |
340,000 | 45,330 cu. ft. @ 10° F 22,660 cu. ft. @ 20° F 15,110 cu. ft. @ 30° F 11,330 cu. ft. @ 40° F | 5,130 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 85 | 325° | 5.8 | 39" | 45" | 28" | Steel | 0000000 | 00000000 |
Horizontal Flow Hazardous Location Large-Space Steam Heaters
Use steam from your existing boilers to evenly warm a large space. These heaters are for indoor use where flammable gases, vapors, and dust are present—they have an explosion-proof motor that is UL listed and CSA certified for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G. Heat output is based on steam at 2 psi.
Control with a line-voltage thermostat (not included).
Inlet | Outlet | Steam | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temperature, °F | Current, A | Ht. | Wd. | Dp. | Housing Material | Each | |
120V AC/240V AC, Single Phase—Wire Leads | |||||||||||||||||
Ceiling Mount | |||||||||||||||||
70,600 | 9,410 cu. ft. @ 10° F 4,700 cu. ft. @ 20° F 3,130 cu. ft. @ 30° F 2,350 cu. ft. @ 40° F | 1,265 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 200 | 600° | 2.5 | 18" | 16" | 21" | Steel | 0000000 | 000000000 |
106,000 | 14,130 cu. ft. @ 10° F 7,060 cu. ft. @ 20° F 4,710 cu. ft. @ 30° F 3,530 cu. ft. @ 40° F | 1,940 | 2 | NPT | Female | 2 | NPT | Female | 200 | 600° | 2.5 | 21" | 19" | 21" | Steel | 0000000 | 00000000 |
157,300 | 20,970 cu. ft. @ 10° F 10,480 cu. ft. @ 20° F 6,990 cu. ft. @ 30° F 5,240 cu. ft. @ 40° F | 2,890 | 2 | NPT | Female | 2 | NPT | Female | 200 | 600° | 3.7 | 25" | 22" | 25" | Steel | 0000000 | 00000000 |
267,800 | 35,700 cu. ft. @ 10° F 17,850 cu. ft. @ 20° F 11,900 cu. ft. @ 30° F 8,920 cu. ft. @ 40° F | 4,770 | 2 1/2 | NPT | Female | 2 1/2 | NPT | Female | 200 | 600° | 4 | 33" | 29" | 25" | Steel | 0000000 | 00000000 |
Vertical Flow Hazardous Location Large-Space Steam and Water Heaters
Focus warm air in a specific spot using steam and water from your existing boilers. Use indoors where flammable gases, vapors, dust, and fibers are present—they meet Class I, Divisions 1 and 2, Group D; Class II, Divisions 1 and 2, Groups F and G; and Class III, Divisions 1 and 2. Heat output is based on steam at 2 psi.
Control with a line-voltage thermostat (not included).
Inlet | Outlet | Steam | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | Airflow, cfm | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Temperature, °F | Current, A | Ht. | Dia. | Housing Material | Each | |
120V AC, Single Phase—Wire Leads | ||||||||||||||||
Ceiling Mount | ||||||||||||||||
59,000 | 7,860 cu. ft. @ 10° F 3,930 cu. ft. @ 20° F 2,620 cu. ft. @ 30° F 1,960 cu. ft. @ 40° F | 1,155 | 1 1/4 | NPT | Male | 1 1/4 | NPT | Male | 85 | 325° | 4.1 | 10" | 25" | Steel | 0000000 | 000000000 |
95,000 | 12,660 cu. ft. @ 10° F 6,330 cu. ft. @ 20° F 4,220 cu. ft. @ 30° F 3,160 cu. ft. @ 40° F | 1,665 | 1 1/4 | NPT | Male | 1 1/4 | NPT | Male | 85 | 325° | 4.1 | 11" | 25" | Steel | 0000000 | 00000000 |
139,000 | 18,530 cu. ft. @ 10° F 9,260 cu. ft. @ 20° F 6,170 cu. ft. @ 30° F 4,630 cu. ft. @ 40° F | 2,660 | 1 1/2 | NPT | Male | 1 | NPT | Male | 85 | 325° | 4.1 | 10" | 35" | Steel | 0000000 | 00000000 |
161,000 | 21,460 cu. ft. @ 10° F 10,730 cu. ft. @ 20° F 7,150 cu. ft. @ 30° F 5,360 cu. ft. @ 40° F | 2,940 | 1 1/2 | NPT | Male | 1 | NPT | Male | 85 | 325° | 7.2 | 18" | 35" | Steel | 0000000 | 00000000 |
193,000 | 25,730 cu. ft. @ 10° F 12,860 cu. ft. @ 20° F 8,570 cu. ft. @ 30° F 6,430 cu. ft. @ 40° F | 3,500 | 1 1/2 | NPT | Male | 1 | NPT | Male | 85 | 325° | 7.2 | 18" | 35" | Steel | 0000000 | 00000000 |
279,000 | 37,200 cu. ft. @ 10° F 18,600 cu. ft. @ 20° F 12,400 cu. ft. @ 30° F 9,300 cu. ft. @ 40° F | 5,460 | 2 | NPT | Male | 1 1/4 | NPT | Male | 85 | 325° | 5.8 | 18" | 35" | Steel | 0000000 | 00000000 |
Enclosure Heaters
Warm the air in your enclosure to keep electrical components at the ideal operating temperature. These heaters also reduce humidity, preventing condensation that causes corrosion and short circuits. The fan blows hot air upward so it heats the enclosure evenly.
Heaters with thermostat are adjustable, so you can decide when the heater turns on and off.
All heaters meet American, Canadian, and European safety standards.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temp. Change | Wattage, W | Current, A | Heating Method | Temp. Setting, °F | Ht. | Wd. | Dp. | Surface Temp., °F | Housing Material | Mounting Hole Location | Specifications Met | Each | |
120V AC | ||||||||||||||
300 | 40 cu. ft. @ 10° F 20 cu. ft. @ 20° F 15 cu. ft. @ 30° F 10 cu. ft. @ 40° F | 100 | 0.83 | Fan | 0° to 100° | 6" | 4" | 4" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 0000000 |
600 | 90 cu. ft. @ 10° F 45 cu. ft. @ 20° F 30 cu. ft. @ 30° F 20 cu. ft. @ 40° F | 200 | 1.67 | Fan | 0° to 100° | 6" | 4" | 4" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 000000 |
1,300 | 180 cu. ft. @ 10° F 90 cu. ft. @ 20° F 60 cu. ft. @ 30° F 45 cu. ft. @ 40° F | 400 | 3.33 | Fan | 0° to 100° | 8" | 5" | 5" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 000000 |
2,700 | 360 cu. ft. @ 10° F 180 cu. ft. @ 20° F 120 cu. ft. @ 30° F 90 cu. ft. @ 40° F | 800 | 6.67 | Fan | 0° to 100° | 8" | 5" | 5" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 000000 |
240V AC | ||||||||||||||
300 | 40 cu. ft. @ 10° F 20 cu. ft. @ 20° F 15 cu. ft. @ 30° F 10 cu. ft. @ 40° F | 100 | 0.42 | Fan | 0° to 100° | 6" | 4" | 4" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 000000 |
600 | 90 cu. ft. @ 10° F 45 cu. ft. @ 20° F 30 cu. ft. @ 30° F 20 cu. ft. @ 40° F | 200 | 0.83 | Fan | 0° to 100° | 6" | 4" | 4" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 000000 |
1,300 | 180 cu. ft. @ 10° F 90 cu. ft. @ 20° F 60 cu. ft. @ 30° F 45 cu. ft. @ 40° F | 400 | 1.67 | Fan | 0° to 100° | 8" | 5" | 5" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 000000 |
2,700 | 360 cu. ft. @ 10° F 180 cu. ft. @ 20° F 120 cu. ft. @ 30° F 90 cu. ft. @ 40° F | 800 | 3.33 | Fan | 0° to 100° | 8" | 5" | 5" | Not Rated | Aluminum | Side | CE Marked, CSA Certified, UL Recognized Component | 000000000 | 000000 |
Low-Profile Enclosure Heaters
Radiate heat inside narrow spaces to keep equipment warm and dry. These slim heaters fit where standard ones don’t. They protect equipment from premature failure caused by cold, condensation, and humidity.
Heaters with a thermostat automatically turn on and off to maintain the set temperature range. Heaters with a nonadjustable thermostat have a set range that you cannot adjust.
For technical drawings and 3-D models, click on a part number.
Overall | Mounting | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temp. Change | Wattage, W | Watt Density, W/sq. in. | Current, A | Radiant Heater Type | Lg. | Wd. | Ht. | Surface Temp., °F | Fasteners Included | No. of Holes | Hole Dia. | Hole Ctr.-to-Ctr. | Flange Ht. | Each | |
120V AC—Wire Leads | ||||||||||||||||
40° to 60° F Temperature Setting Range | ||||||||||||||||
200 | 26 cu. ft. @ 10° F 13 cu. ft. @ 20° F 8 cu. ft. @ 30° F 6 cu. ft. @ 40° F | 60 | 5 | 0.52 | Enclosed | 6" | 2" | 9/16" | 65° | No | 2 | 1/4" | 4" | 1/2" | 0000000 | 0000000 |
400 | 53 cu. ft. @ 10° F 26 cu. ft. @ 20° F 17 cu. ft. @ 30° F 13 cu. ft. @ 40° F | 120 | 5 | 1.04 | Enclosed | 12" | 2" | 9/16" | 65° | No | 2 | 1/4" | 10" | 1/2" | 0000000 | 000000 |
105° to 140° F Temperature Setting Range | ||||||||||||||||
200 | 26 cu. ft. @ 10° F 13 cu. ft. @ 20° F 8 cu. ft. @ 30° F 6 cu. ft. @ 40° F | 60 | 5 | 0.52 | Enclosed | 6" | 2" | 9/16" | 145° | No | 2 | 1/4" | 4" | 1/2" | 0000000 | 000000 |
400 | 53 cu. ft. @ 10° F 26 cu. ft. @ 20° F 17 cu. ft. @ 30° F 13 cu. ft. @ 40° F | 120 | 5 | 1.04 | Enclosed | 12" | 2" | 9/16" | 145° | No | 2 | 1/4" | 10" | 1/2" | 0000000 | 000000 |
150° to 180° F Temperature Setting Range | ||||||||||||||||
200 | 26 cu. ft. @ 10° F 13 cu. ft. @ 20° F 8 cu. ft. @ 30° F 6 cu. ft. @ 40° F | 60 | 5 | 0.52 | Enclosed | 6" | 2" | 9/16" | 180° | No | 2 | 1/4" | 4" | 1/2" | 0000000 | 000000 |
400 | 53 cu. ft. @ 10° F 26 cu. ft. @ 20° F 17 cu. ft. @ 30° F 13 cu. ft. @ 40° F | 120 | 5 | 1.04 | Enclosed | 12" | 2" | 9/16" | 180° | No | 2 | 1/4" | 10" | 1/2" | 0000000 | 000000 |
Direct Long-Range Ceiling-Mount Gas Heaters
Our most powerful ceiling-mount direct heaters, these warm people in large spaces, such as warehouses. All have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Heaters with two burners allow for greater control over how much heat is generated—use one or both burners depending on your needs.
Heaters with a pilot light ignition do not require electricity. Heaters with an electronic spark ignition are good for drafty areas where a pilot light could be extinguished.
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 40 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 000000000 | 000000 |
60,000 | 2,050 sq. ft. @ 10° F 680 sq. ft. @ 20° F 510 sq. ft. @ 30° F 510 sq. ft. @ 40° F | 1 | 60 | 3/4 | NPT | Female | 15 | 12" | 46" | 20" | Steel | No | 50° to 90° | 00000000 | 000000 | 000000000 | 00000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 100 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 000000000 | 00000 |
120,000 | 4,100 sq. ft. @ 10° F 1,370 sq. ft. @ 20° F 1,020 sq. ft. @ 30° F 1,020 sq. ft. @ 40° F | 2 | 120 | 3/4 | NPT | Female | 36 | 11" | 83" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 000000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Pilot Burners | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, cfh | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 40 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 00000000 | 000000 |
60,000 | 2,050 sq. ft. @ 10° F 680 sq. ft. @ 20° F 510 sq. ft. @ 30° F 510 sq. ft. @ 40° F | 1 | 60 | 3/4 | NPT | Female | 15 | 12" | 46" | 20" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 100 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
120,000 | 4,100 sq. ft. @ 10° F 1,370 sq. ft. @ 20° F 1,020 sq. ft. @ 30° F 1,020 sq. ft. @ 40° F | 2 | 120 | 3/4 | NPT | Female | 36 | 11" | 83" | 22" | Steel | No | 50° to 90° | 00000000 | 00000000 | 00000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Thermocouples | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 2 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 000000000 | 000000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 5 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 000000000 | 00000 |
Heaters | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | O'all | Repl. Pilot Burners | |||||||||||||||
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption, lbs./hr. | Pipe Size | Thread Type | Gender | Max. Mount. Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temp. Setting, °F | Each | Each | ||
40,000 | 1,170 sq. ft. @ 10° F 390 sq. ft. @ 20° F 290 sq. ft. @ 30° F 290 sq. ft. @ 40° F | 1 | 2 | 3/4 | NPT | Female | 12 | 12" | 31" | 20" | Steel | No | 50° to 90° | 00000000 | 0000000 | 00000000 | 000000 |
100,000 | 2,930 sq. ft. @ 10° F 980 sq. ft. @ 20° F 730 sq. ft. @ 30° F 730 sq. ft. @ 40° F | 2 | 5 | 3/4 | NPT | Female | 28 | 11" | 61" | 22" | Steel | No | 50° to 90° | 00000000 | 000000 | 00000000 | 00000 |
Direct Long-Range Wall-Mount Gas Heaters
Use these powerful heaters to warm people in large spaces, such as warehouses. They have a safety shut-off that cuts the gas supply if the flame goes out. They include a wall-mount thermostat.
Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heat Output, Btu/hr. | Max. Area Heated @ Temperature Change | No. of Burners | Max. Fuel Consumption | Pipe Size | Thread Type | Gender | Max. Mounting Ht., ft. | Ht. | Wd. | Dp. | Housing Material | For Use Outdoors | Temperature Setting, °F | Each | |
Natural Gas Heaters | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
22,000 | 640 sq. ft. @ 10° F 320 sq. ft. @ 20° F 210 sq. ft. @ 30° F 160 sq. ft. @ 40° F | 1 | 25 cfh | 1/2 | NPT | Female | 9 | 7" | 30" | 13" | Steel | No | 35° to 75° | 00000000 | 0000000 |
Propane Heaters | |||||||||||||||
Pilot Light Ignition | |||||||||||||||
22,000 | 640 sq. ft. @ 10° F 320 sq. ft. @ 20° F 210 sq. ft. @ 30° F 160 sq. ft. @ 40° F | 1 | 1 lbs./hr. | 1/2 | NPT | Female | 9 | 7" | 30" | 13" | Steel | No | 35° to 75° | 00000000 | 000000 |