About Actuated On/Off Valves
More
Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
About Air Preparation
More
High-Force Linear Solenoids
High-force solenoids draw more power than our other open-frame solenoids, so they can deliver higher force. They also have a laminated rod that minimizes friction during operation.
Pull solenoids exert force when the rod retracts.
For technical drawings and 3-D models, click on a part number.
Length | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Voltage | Power Draw, Watts | On/Off Time, Minutes | Wd. | Ht. | Rod Dia. (R) | Each | |
For AC Voltage, 60 Hz | ||||||||||||
Pull | ||||||||||||
1" | 2.7" | 3.4" | 3.4" | 195 | 240V AC | 228 | 3/27 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 000000 |
Length | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Max. Stroke Lg. | Retracted | Extended | Overall | Force @ 50% Stroke Lg., oz. | Voltage | Power Draw, Watts | Wd. | Ht. | Rod Dia. (R) | Each | |
For AC Voltage, 60 Hz | |||||||||||
Pull | |||||||||||
1" | 2.7" | 3.4" | 3.4" | 105 | 240V AC | 49 | 1 7/8" | 2 1/8" | 0.49" | 000000 | 000000 |
Solenoid On/Off Valves
These solenoid valves operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Normally closed valves are closed unless actuated. Normally open valves are open unless actuated.
Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation. Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
All IP- or NEMA-rated valves stand up to dust and washdowns. NEMA 4X valves withstand corrosive liquid.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
- For Use With: Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton
- Specifications Met: UL Listed
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Each | |
Bronze Body with Wire Leads—Buna-N Rubber Seal | |||||||||
---|---|---|---|---|---|---|---|---|---|
NPT Female | |||||||||
1/4 | 2.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 0000000 |
3/8 | 2.3 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 000000 |
1/2 | 3.9 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 2 3/4" | 4 15/16" | NEMA 4X | 00000000 | 000000 |
3/4 | 5.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 1/4" | 5 1/4" | NEMA 4X | 00000000 | 000000 |
1 | 11.6 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 3 13/16" | 5 11/16" | NEMA 4X | 00000000 | 000000 |
1 1/4 | 12.1 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 4 1/4" | 6 5/16" | NEMA 4X | 00000000 | 000000 |
1 1/2 | 26 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 4 7/8" | 6 15/16" | NEMA 4X | 00000000 | 000000 |
2 | 48 | 125 psi @ 220° F | Pressure Drop Assisted | -40° to 220° | 5 7/8" | 7 9/16" | NEMA 4X | 00000000 | 00000000 |
- For Use With: Water, Oil, Air, Argon, Helium, Neon, Xenon, Krypton
- Specifications Met: See table
Valves | Replacement Solenoid Coils | Repair Kits for Flow-Control Valves | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Specifications Met | Each | Each | Each | |||
Brass Body with DIN Connection—Buna-N Rubber Seal | ||||||||||||||
NPT Female | ||||||||||||||
1/4 | 1.4 | 200 psi @ 70° F | Zero Pressure Drop | 15° to 195° | 2 1/4" | 3 1/2" | IP65, NEMA 4 | CE Marked | 00000000 | 0000000 | 0000000 | 000000 | 0000000 | 000000 |
1/4 | 1.4 | 300 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 2" | 3 5/8" | IP65, NEMA 4 | CE Marked | 00000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
3/8 | 1.4 | 200 psi @ 70° F | Zero Pressure Drop | 15° to 195° | 2 1/4" | 3 1/2" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
3/8 | 1.8 | 300 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 2" | 3 5/8" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
1/2 | 1.8 | 300 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 2 13/16" | 3 5/8" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
1/2 | 2.8 | 200 psi @ 70° F | Zero Pressure Drop | 15° to 195° | 2 3/4" | 4" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 00000000 | 00000 |
3/4 | 2.8 | 200 psi @ 70° F | Zero Pressure Drop | 15° to 195° | 2 3/4" | 4" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 00000000 | 00000 |
3/4 | 9.8 | 230 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 4 1/16" | 4 1/8" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
1 | 8.4 | 115 psi @ 70° F | Zero Pressure Drop | 15° to 195° | 4 1/16" | 4 1/4" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 00000000 | 00000 |
1 | 13 | 230 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 4 1/16" | 4 1/2" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
1 1/4 | 28 | 150 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 5 5/8" | 5" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
1 1/2 | 36 | 150 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 5 5/8" | 5" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
2 | 53 | 150 psi @ 70° F | Pressure Drop Assisted | 15° to 195° | 6 3/4" | 5 9/16" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
Brass Body with DIN Connection—Fluoroelastomer Rubber Seal | ||||||||||||||
NPT Female | ||||||||||||||
1 1/2 | 19 | 230 psi @ 280° F | Zero Pressure Drop | 15° to 280° | 5 1/16" | 5 1/8" | IP65, NEMA 4 | CE Marked | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |
- For Use With: Water, Air, Argon, Helium, Neon, Xenon, Krypton
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Each | |
Brass Body with DIN Connection—Buna-N Rubber Seal | |||||||||
---|---|---|---|---|---|---|---|---|---|
NPT Female | |||||||||
1/2 | 2.5 | 130 psi @ 140° F | Pressure Drop Assisted | 15° to 195° | 2 5/8" | 3 1/8" | IP65 | 00000000 | 0000000 |
3/4 | 5.9 | 130 psi @ 140° F | Pressure Drop Assisted | 15° to 195° | 3 1/8" | 3 5/8" | IP65 | 00000000 | 000000 |
Premium Solenoid On/Off Valves
- For Use With: Water, Air, Argon, Helium, Neon, Xenon, Krypton
- Seal Material: Buna-N Rubber
These top-of-the-line valves are comparable to Asco Red Hat 8210G Series and Parker Gold Ring 23C Series. They operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Normally closed valves are closed unless actuated.
Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Valves | Repair Kits | Replacement Solenoid Coils | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Each | Each | Each | |||
Brass Body with Wire Leads | |||||||||||||||
Normally Closed—240V AC | |||||||||||||||
3/8 | Female | NPT | 3 | 150 psi @ 180° F | Zero Pressure Drop | 35° to 180° | 2 3/4" | 3 13/16" | NEMA 4X | 0000000 | 0000000 | 00000000 | 0000000 | 000000 | 0000000 |
3/8 | Female | NPT | 3 | 150 psi @ 180° F | Pressure Drop Assisted | 35° to 180° | 2 3/4" | 3 3/8" | NEMA 4X | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
1/2 | Female | NPT | 4 | 150 psi @ 180° F | Zero Pressure Drop | 35° to 180° | 2 3/4" | 3 13/16" | NEMA 4X | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
1/2 | Female | NPT | 4 | 150 psi @ 180° F | Pressure Drop Assisted | 35° to 180° | 2 3/4" | 3 3/8" | NEMA 4X | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
3/4 | Female | NPT | 5 | 150 psi @ 180° F | Zero Pressure Drop | 35° to 180° | 2 13/16" | 4 1/8" | NEMA 4X | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
3/4 | Female | NPT | 5 | 125 psi @ 180° F | Pressure Drop Assisted | 35° to 180° | 2 13/16" | 3 11/16" | NEMA 4X | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
1 | Female | NPT | 13 | 150 psi @ 180° F | Pressure Drop Assisted | 35° to 180° | 3 3/4" | 5 5/8" | NEMA 4X | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
1 | Female | NPT | 13 | 125 psi @ 180° F | Zero Pressure Drop | 35° to 180° | 3 3/4" | 5 1/8" | __ | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
1 1/2 | Female | NPT | 22.5 | 125 psi @ 180° F | Zero Pressure Drop | 35° to 180° | 4 5/8" | 5 7/8" | __ | 0000000 | 000000 | 00000000 | 000000 | 000000 | 000000 |
2 | Female | NPT | 43 | 125 psi @ 180° F | Pressure Drop Assisted | 35° to 180° | 5 1/16" | 7 5/16" | __ | 0000000 | 000000 | 000000 | 000000 | 000000 | 000000 |
Solenoid On/Off Valves with Easy-Access Strainer for Detergent
- For Use With: Soap Solutions
- Seal Material: EPDM Rubber
A built-in strainer traps debris and allows you to replace the screen without disconnecting your pipeline. These valves operate on electricity to automatically start and stop flow.
All valves are normally closed unless actuated. They require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Mesh Size | Quick-Disconnect Tab Wd. | Each | |
Brass Body with Quick-Disconnect Terminals | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Normally Closed—240V AC | ||||||||||||
1/4 | Female | NPT | 1 | 125 psi @ 180° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 3/4" | 60 × 60 | 1/4" | 0000000 | 000000 |
3/8 | Female | NPT | 1 | 125 psi @ 180° F | Pressure Drop Assisted | 35° to 180° | 2 3/8" | 3 3/4" | 60 × 60 | 1/4" | 0000000 | 00000 |
Solenoid On/Off Valves for Natural Gas, Propane, and Butane
- For Use With: Natural Gas, Propane, Butane
- Seal Material: Buna-N Rubber
- Specifications Met: See Table
Install these valves in gas pipelines to control the flow of natural gas, propane, and butane to equipment. They operate on electricity to automatically start and stop flow.
Valves are normally closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
For technical drawings and 3-D models, click on a part number.
Valves | Repair Kits | Replacement Solenoid Coils | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Environmental Rating | Specifications Met | Each | Each | Each | |||
Aluminum Body with Wire Leads | |||||||||||||||
Normally Closed—240V AC | |||||||||||||||
1/2 | Female | NPT | 2 psi @ 125° F | Zero Pressure Drop | -40° to 125° | 2 3/4" | 4" | NEMA 4X | CSA Certified; FM Approved; UL Listed | 00000000 | 0000000 | 00000000 | 0000000 | 000000 | 0000000 |
1 | Female | NPT | 0.5 psi @ 125° F | Zero Pressure Drop | -40° to 125° | 5" | 6 13/16" | NEMA 4X | CSA Certified; UL Listed | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 000000 |
Solenoid Coils for Flow-Control Valves
Coils are original manufacturer replacements for Parker Hannifin, GC, ASCO, Granzow, Magnatrol and Fairchild valves. Match your valve’s part number to the compatible solenoid coil.
For Valve Manufacturer Model Number | Coil Material | Each | |
ASCO 8040 Series | |||
---|---|---|---|
240V AC | |||
8040C004-240V-AC, 8040C005-240V-AC | Copper | 00000000 | 0000000 |
ASCO 8210 Series | |||
240V AC | |||
8210G001-240V-AC, 8210G002-240V-AC, 8210G004-240V-AC, 8210G009-240V-AC | Copper | 000000 | 000000 |
8210G054-240V-AC, 8210G056-240V-AC | Copper | 000000 | 000000 |
8210G093-240V-AC, 8210G094-240V-AC, 8210G095-240V-AC | Copper | 000000 | 000000 |
Granzow E, H, W | |||
240V AC | |||
E2B59-000, E3B59-000, E4B59-000, H2B59-00Y, H3B59-00Y, H4B59-00Y, H5B59-00Y, H6B59-00Y, H8B59-00V, W5B59-000, W6B59-000, W7B59-000, W8B59-000, W9B59-000 | Copper | 0000000 | 00000 |
Parker Hannifin Gold Ring Series | |||
240V AC | |||
06F22C2140AAF4C15 | Brass | 0000000 | 00000 |
06F23C2140ACF4C15 | Brass | 0000000 | 00000 |
Single-Action Electrically Operated Air Directional Control Valves
These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated. Valves without an exhaust connection exhaust air to the atmosphere.
Normally closed valves block airflow until actuated.
Valves with spring return actuation go back to their original position when voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Lg. | Wd. | Ht. | Mount Type | Voltage | Each | ||
Single Solenoid—Spring Return Actuation | ||||||||||||||
G | 3 | 1/8 NPT | 1/8 NPT | __ | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/8" | Screw In | 240V AC | 00000000 | 0000000 |
H | 3 | 1/8 NPT | 1/8 NPT | Threaded | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/4" | Screw In | 240V AC | 00000000 | 000000 |
Two-Speed Two-Action Electrically Operated Air Directional Control Valves
Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
Valves with spring return actuation go back to their original position when voltage is removed. Valves with electric (solenoid) return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
Valves | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
O'all | Replacement Solenoids | |||||||||||||||
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Mount Type | Voltage | Each | Each | |||
Single Solenoid—Spring Return Actuation | ||||||||||||||||
C | 5 | 1/4 NPT | 1/4 NPT | 56 | 1 | 40-120 | Not Rated | 4 3/8" | 1 7/8" | 3 3/8" | Screw In | 240V AC | 00000000 | 0000000 | 000000 | 000000 |
Double Solenoid—Electric (Solenoid) Return Actuation | ||||||||||||||||
J | 5 | 1/4 NPT | 1/4 NPT | 56 | 1 | 40-120 | Not Rated | 5 7/8" | 1 7/8" | 3 3/8" | Screw In | 240V AC | 0000000 | 000000 | 000000 | 00 |
Timer-Operated Compressed Air Drain Valves
Set the electronic timer on these drain valves to open automatically at your specified time interval. They’re excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line.
Drain valves that meet NEMA 4X are rated for protection from dirt, washdowns, and corrosion.
Install optional strainers before drain valves to prevent damage from debris in your pipeline.
For technical drawings and 3-D models, click on a part number.
Inlet | Outlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Cycle Interval | Drain Time | Max. Temp., °F | Includes | Each | |
Brass Housing—NEMA 4X Enclosure | ||||||||||||||||
Electric Powered, 240V AC—Hardwire | ||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 2.9 | 200 | 4 1/8" | 6" | 3 3/4" | 0-50 min. | 1-15 sec. | 180° | Strainer | 0000000 | 0000000 |
Replacement Filter Screens for Optional Strainers | 0000000 | Each | 00000 |