Filter by
Direction of Force
Rod Return Type
Voltage Type
Direction of Operation
Duty Cycle
Torque @ Half Rotary Stroke
Mounting Position
Torque @ Full Rotary Stroke
Current
Rod End Type
Electrical Connection
Resistance
DFARS Specialty Metals
Export Control Classification Number (ECCN)
REACH
RoHS
Mounting Thread Size
Body Material
Maximum Temperature
Insulation Class
Rotary Solenoids

Convert electricity into rotational motion to actuate switches, valves, and locks. These solenoids have a built-in spring that returns the rod to its original position, making them good for use in valves that require precision to fully open or close.
Intermittent-use solenoids are designed to run for seconds or minutes at a time with rest in between. Continuous-use solenoids can operate for hours or days at a time without overheating.
For technical drawings and 3-D models, click on a part number.
Intermittent Use

Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
Max. Stroke Rotation | Torque @ 50% Rotation, in.-oz. | Direction of Force | Power Draw, Watts | On/Off Time, Minutes | Dia. | Lg. | Rod Dia. (R) | Each | |
12V DC | |||||||||
40° | 11.2 | Counterclockwise | 36 | 1/3 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 0000000 |
40° | 17 | Counterclockwise | 40 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 24 | Counterclockwise | 44 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 41 | Counterclockwise | 48 | 3.5/10.5 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 |
24V DC | |||||||||
40° | 11.2 | Counterclockwise | 36 | 1/3 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 000000 |
40° | 17 | Counterclockwise | 40 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 24 | Counterclockwise | 44 | 1.5/4.5 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 41 | Counterclockwise | 48 | 3.5/10.5 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 |
Continuous Use

Overall | ||||||||
---|---|---|---|---|---|---|---|---|
Max. Stroke Rotation | Torque @ 50% Rotation, in.-oz. | Direction of Force | Power Draw, Watts | Dia. | Lg. | Rod Dia. (R) | Each | |
12V DC | ||||||||
40° | 2.8 | Counterclockwise | 9 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 0000000 |
40° | 6.8 | Counterclockwise | 10 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 9.5 | Counterclockwise | 11 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 16 | Counterclockwise | 12 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 |
24V DC | ||||||||
40° | 2.8 | Counterclockwise | 9 | 1 1/2" | 1 3/4" | 0.19" | 0000000 | 000000 |
40° | 6.8 | Counterclockwise | 10 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 9.5 | Counterclockwise | 11 | 2" | 2 1/4" | 0.24" | 0000000 | 000000 |
40° | 16 | Counterclockwise | 12 | 2 3/4" | 2 1/4" | 0.24" | 0000000 | 000000 |