Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Fast-Switching Single-Action Electrically Operated Air Directional Control Valves
Run through equipment cycles up to 30% faster than with standard valves. They create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed. Also known as 3-way and 3/2 valves.
Normally open valves allow airflow until actuated. Normally closed valves block airflow until actuated.
Mufflers (sold separately) reduce exhaust noise.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Valves | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mufflers | ||||||||||||||||
No. of Flow Ports | For Inlet Tube OD, mm | For Outlet Tube OD, mm | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg., mm | Wd., mm | Ht., mm | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | Each | ||
Normally Open Flow Positions | |||||||||||||||||
3 | 4 | 4 | 5.763 | 0.102 | -13 to 116 | 26.5 | 24V DC | 73 | 10 | 34 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 0000000 | 0000000 | 000000 |
3 | 8 | 8 | 22.994 | 0.407 | -13 to 116 | 26.5 | 24V DC | 114.6 | 18 | 52 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
Normally Closed Flow Positions | |||||||||||||||||
3 | 4 | 4 | 5.763 | 0.102 | -13 to 116 | 26.5 | 24V DC | 73 | 10 | 34 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
3 | 6 | 6 | 11.469 | 0.203 | -13 to 116 | 26.5 | 24V DC | 94.5 | 14 | 45 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
3 | 8 | 8 | 22.994 | 0.407 | -13 to 116 | 26.5 | 24V DC | 114.6 | 18 | 56 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg., mm | Wd., mm | Ht., mm | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
Normally Open Flow Positions | |||||||||||||||
3 | 1/8 BSPP | 1/8 BSPP | 11.469 | 0.203 | -13 to 116 | 26.5 | 24V DC | 34 | 10 | 73 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 0000000 |
Mounting Brackets for Threaded Valves | 0000000 | Each | 00000 |
Two-Speed Two-Action Electrically Operated Air Directional Control Valves
Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
Valves with spring return actuation go back to their original position when voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Mount Type | Choose a Voltage | Each | ||
Single Solenoid—Spring Return Actuation | ||||||||||||||
A | 5 | 10-32 UNF | 10-32 UNF | 8.2 | 0.26 | 44-150 | Not Rated | 3 7/8" | 5/8" | 1 7/8" | Screw In | 0000000 | 0000000 |
Fast-Switching Two-Speed Two-Action Electrically
Operated Air Directional Control Valves
Run through equipment cycles up to 30% faster than with standard valves. These valves shift between flow positions in 1.7 ms. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Thread Size | Outlet Thread Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Wire Connection Type | Lg., mm | Wd., mm | Ht., mm | Environmental Rating | Specifications Met | Each | |
Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust | |||||||||||||||
5 | M7 × 1 mm | M7 × 1 mm | 5.141 | 0.091 | -13 to 116 | 26.5 | 24V DC | Wire Leads | 84 | 10 | 34 | IP65 | CE Marked, UL Recognized Component, C-UL Recognized Component | 0000000 | 0000000 |
Modular Air Directional Control Valves with Air Manifolds
Mount valves to a single-station base or to a manifold, which allows a single pressure source for multiple valves, then add or remove valves as your needs change. Valves with the same style can be used on the same manifold. For example, you can put a Style B, 2-position, spring-return valve and a Style B, 3-position, solenoid-return valve on the same manifold.
4-way valves create two actions, such as extending and retracting a double-acting cylinder.
5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. 5/3 (exhaust center) valves exhaust all air pressure in the off position, allowing equipment to return to the neutral position. 5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
Valves with spring return actuation go back to their original position when voltage is removed. Valves with electric (solenoid) return actuation go back to their original position when voltage moves from the first solenoid to the second solenoid.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Valves | No. of Flow Ports | No. of Flow Positions | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Wire Connection Type | Lg. | Wd. | Ht. | Mounting Fasteners Included | Choose a Voltage | Each | |
5/2 Flow Pattern | |||||||||||||||
Single Solenoid—Spring Return Actuation | |||||||||||||||
B | 1 | 5 | 2 | 8 | 0.24 | 21 to 101 | Not Rated | Wire Leads | 2 5/8" | 3/8" | 1 1/8" | Yes | 00000000 | 000000 | |
Double Solenoid—Electric (Solenoid) Return Actuation | |||||||||||||||
B | 1 | 5 | 2 | 8 | 0.24 | 21 to 101 | Not Rated | Wire Leads | 3 1/2" | 3/8" | 1 1/8" | Yes | 00000000 | 00000 | |
5/3 (Closed Center) Flow Pattern | |||||||||||||||
Double Solenoid—Electric (Solenoid) Return Actuation | |||||||||||||||
B | 1 | 5 | 3 | 6 | 0.18 | 29 to 101 | Not Rated | Wire Leads | 3 7/8" | 3/8" | 1 1/8" | Yes | 00000000 | 00000 | |
5/3 (Exhaust Center) Flow Pattern | |||||||||||||||
Double Solenoid—Electric (Solenoid) Return Actuation | |||||||||||||||
B | 1 | 5 | 3 | 6 | 0.18 | 29 to 101 | Not Rated | Wire Leads | 3 7/8" | 3/8" | 1 1/8" | Yes | 00000000 | 00000 | |
5/3 (Pressure Center) Flow Pattern | |||||||||||||||
Double Solenoid—Electric (Solenoid) Return Actuation | |||||||||||||||
B | 1 | 5 | 3 | 8 | 0.24 | 29 to 101 | Not Rated | Wire Leads | 3 7/8" | 3/8" | 1 1/8" | Yes | 00000000 | 00000 |