How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Solder-Connect Fittings for Copper Tubing
- Temperature Range: 32° to 200° F
Solder these fittings to copper tubing or the tube end of another fitting for a permanent, leak-tight connection. They are also known as sweat fittings. Fittings have good corrosion resistance. To adhere to safety standards for drinking water systems, use fittings that meet NSF/ANSI 61 or EN 1057.
Copper tube size is the accepted designation of the copper tubing industry, not the actual tube OD.
For technical drawings and 3-D models, click on a part number.
- For Use With: Drinking Water
- Tubing: Use with K, M, L copper
- Specifications Met: See table
Fittings with flange end bolt to equipment or another same-size flange to create an access point within a line.
Copper Tube Size | For Tube OD | Flange OD | Bolt Circle Dia. | Number of Bolt Holes | Bolt Hole Diameter | For Bolt Diameter | Bolts Included | Material | Max. Pressure | Specifications Met | Each | |
1 | 1 1/8" | 4 1/4" | 3 1/8" | 4 | 5/8" | 1/2" | No | Brass | 400 psi @ 72° F | ASME B16.18, NSF/ANSI 61 | 00000000 | 000000 |
1 1/4 | 1 3/8" | 4 5/8" | 3 1/2" | 4 | 5/8" | 1/2" | No | Brass | 400 psi @ 72° F | ASME B16.18, NSF/ANSI 61 | 00000000 | 000000 |
1 1/2 | 1 5/8" | 5" | 3 7/8" | 4 | 5/8" | 1/2" | No | Brass | 400 psi @ 72° F | ASME B16.18, NSF/ANSI 61 | 00000000 | 000000 |
2 | 2 1/8" | 6" | 4 3/4" | 4 | 3/4" | 5/8" | No | Brass | 300 psi @ 72° F | ASME B16.18, NSF/ANSI 61 | 00000000 | 000000 |
- For Use With: Drinking Water
- Tubing: See table
- Specifications Met: See table
Fittings that meet ASTM B379 comply with international standards for tube fitting specifications.
(Web) Table Pivot | Copper Tube Size | For Tube OD | Material | Max. Pressure | For Copper Tube Type | Specifications Met | Each | |
1 | 1/8 | 1/4" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 00000 |
1 | 1/4 | 3/8" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 000 |
1 | 3/8 | 1/2" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 0000 |
1 | 1/2 | 5/8" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 000 |
1 | 5/8 | 3/4" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 0000 |
1 | 3/4 | 7/8" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 000 |
1 | 1 | 1 1/8" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 0000 |
1 | 1 1/4 | 1 3/8" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 0000 |
1 | 1 1/2 | 1 5/8" | Copper | 400 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 0000 |
2 | 2 | 2 1/8" | Copper | 300 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 0000000 | 0000 |
2 | 2 1/2 | 2 5/8" | Copper | 300 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 00000 |
3 | 3 | 3 1/8" | Copper | 300 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 00000 |
3 | 3 1/2 | 3 5/8" | Copper | 300 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 00000 |
4 | 4 | 4 1/8" | Copper | 200 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 00000 |
5 | 5 | 5 1/8" | Copper | 200 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 000000 |
6 | 6 | 6 1/8" | Copper | 200 psi @ 72° F | K, M, L | ASME B16.22, MSS-SP104, NSF/ANSI 61 | 00000000 | 000000 |
10 | __ | 10mm | Copper | 800 psi @ 72° F | M | ASTM B379, DVGW GW 8, EN 1057 | 00000000 | 0000 |
10 | __ | 12mm | Copper | 700 psi @ 72° F | M | ASTM B379, DVGW GW 8, EN 1057 | 00000000 | 0000 |
10 | __ | 14mm | Copper | 600 psi @ 72° F | M | ASTM B379, DVGW GW 8, EN 1057 | 00000000 | 0000 |
- For Use With: Drinking Water
- Tubing: Use with K, M, L copper
- Specifications Met: ASME B16.22, MSS-SP104, NSF/ANSI 61
USB Connectors
Often used to prototype or replace damaged connections, these connectors allow you to access and connect to individual USB pins. They are shielded, so they reduce electrical interference from nearby equipment and devices.
Connectors with a solder connection prevent individual strands of wire from fraying while creating a secure connection.
Connectors with a circuit board connection can either be soldered for a permanent connection, or they can be used with circuit board headers for a temporary connection.
For technical drawings and 3-D models, click on a part number.
USB Standard | Transmission Speed, Mbps | For Wire Gauge | For Cable OD, mm | Housing Material | Color | Each | |
Shielded | |||||||
---|---|---|---|---|---|---|---|
2.0 | 480 | 24 | 4.1-4.4 | Plastic | Black | 0000000 | 000000 |
USB Standard | Transmission Speed, Gb/s | Wd. | Lg. | Hole Center-to-Center | Housing Material | Color | Each | |
Shielded | ||||||||
---|---|---|---|---|---|---|---|---|
3.2 Gen 1 | 5 | 5/8" | 15/16" | 0.1" | Steel | Red | 0000000 | 00000 |