Cable
Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -40° to 220° F
Yellow: -55° to 220° F - Insulation: TPE Rubber
SJEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | 0.29" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 10 A @ 86° F | 0.31" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.31" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.33" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.35" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 2 | 14/2 | 18 A @ 86° F | 0.34" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.36" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.39" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 2 | 12/2 | 25 A @ 86° F | 0.41" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.43" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.47" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.57" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.63" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.31" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.33" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.37" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.43" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.57" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 |
- Use For: Outdoors, Power Supply
- EPDM Rubber Outer Insulation: Ultra Flexible
Chlorinated Polyethylene Plastic Outer Insulation: Flexible - Temperature Range: See table
- Insulation:
Outer: See table
Inner: EPDM Rubber
Ultra-flexible cable is good for applications that require tight turns.
SJOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The outer insulation has good tensile strength.
Flame rated cable meets requirements for preventing the spread of flames based on a timed test. FT1 cable is suspended vertically during testing. FT2 cable is suspended horizontally during testing.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Outer Insulation Material | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | -40° to 190° | 0.29" | EPDM Rubber | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 10 A @ 86° F | -40° to 190° | 0.31" | EPDM Rubber | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
18 | 4 | 18/4 | 7 A @ 86° F | -40° to 190° | 0.33" | EPDM Rubber | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 13 A @ 86° F | -40° to 190° | 0.31" | EPDM Rubber | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 13 A @ 86° F | -40° to 190° | 0.33" | EPDM Rubber | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 86° F | -40° to 190° | 0.37" | EPDM Rubber | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 2 | 14/2 | 18 A @ 86° F | -40° to 190° | 0.34" | EPDM Rubber | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | -40° to 190° | 0.37" | EPDM Rubber | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | -40° to 190° | 0.41" | EPDM Rubber | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 2 | 12/2 | 25 A @ 86° F | -40° to 190° | 0.41" | EPDM Rubber | Black, White | UL Listed, CSA Certified | Bare Copper | 000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | -40° to 190° | 0.43" | EPDM Rubber | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | -40° to 190° | 0.48" | EPDM Rubber | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | -40° to 220° | 0.56" | Chlorinated Polyethylene Plastic | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | -40° to 190° | 0.58" | EPDM Rubber | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | -40° to 190° | 0.66" | EPDM Rubber | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | -55° to 220° | 0.31" | EPDM Rubber | Black, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
18 | 3 | 18/3 | 10 A @ 86° F | -55° to 220° | 0.32" | EPDM Rubber | Black, Green/Yellow, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 2 | 16/2 | 13 A @ 86° F | -55° to 220° | 0.32" | EPDM Rubber | Black, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 3 | 16/3 | 13 A @ 86° F | -55° to 220° | 0.34" | EPDM Rubber | Black, Green/Yellow, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
16 | 4 | 16/4 | 10 A @ 86° F | -55° to 220° | 0.37" | EPDM Rubber | Black, Green/Yellow, Red, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | -55° to 220° | 0.38" | EPDM Rubber | Black, Green/Yellow, White | UL Listed, CSA Certified, UL 2556 FT1 | Tin-Plated Copper | 0000000 | 0000 | 0000 |
Coiled Cable
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
Ultra-flexible cable extends and retracts more easily than flexible cable.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJOW and SOW have a multipurpose neoprene insulation. SJEOW and SEOW have a TPE rubber insulation that also withstands chemicals.
- Use For: Outdoors, Power Supply
- Ultra Flexible
- Temperature Range: -40° to 190° F
- Insulation:
Outer: Neoprene Rubber
Inner: EPDM Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | |
300V AC Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
18 | 2 | 18/2 | 10 A @ 86° F | 0.32" | 1.2" | Black | Black, White | UL Listed, CSA Certified | 00000000 | ||
18 | 3 | 18/3 | 7 A @ 86° F | 0.35" | 1.3" | Black | Black, Green, White | UL Listed, CSA Certified | 00000000 | ||
18 | 4 | 18/4 | 5 A @ 86° F | 0.38" | 1.3" | Black | Black, Green, Red, White | UL Listed, CSA Certified | 00000000 | ||
18 | 5 | 18/5 | 5 A @ 86° F | 0.44" | 1.6" | Black | Black, Green, Orange, Red, White | UL Listed, CSA Certified | 00000000 | ||
18 | 7 | 18/7 | 4 A @ 86° F | 0.5" | 1.9" | Black | Black, Blue, Brown, Green, Red, White, Yellow | UL Listed | 00000000 | ||
18 | 15 | 18/15 | 3 A @ 86° F | 0.58" | 2" | Black | Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow | __ | 00000000 | ||
16 | 2 | 16/2 | 13 A @ 86° F | 0.36" | 1.3" | Black | Black, White | UL Listed, CSA Certified | 00000000 | ||
16 | 3 | 16/3 | 10 A @ 86° F | 0.39" | 1.3" | Black | Black, Green, White | UL Listed, CSA Certified | 00000000 |
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
300V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18 | 2 | 18/2 | 10 A @ 86° F | 0.31" | 1.1" | Black | Black, White | UL Listed, CSA Certified | 0000000 | ||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.33" | 1.3" | Black | Black, Green, White | UL Listed, CSA Certified | 0000000 | ||||
18 | 4 | 18/4 | 7 A @ 86° F | 0.37" | 1.5" | Black | Black, Green, Red, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 2 | 16/2 | 13 A @ 86° F | 0.34" | 1.3" | Black | Black, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 3 | 16/3 | 13 A @ 86° F | 0.37" | 1.5" | Black | Black, Green, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 4 | 16/4 | 10 A @ 86° F | 0.4" | 1.6" | Black | Black, Green, Red, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 5 | 16/5 | 8 A @ 86° F | 0.42" | 1.59" | Black | Black, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 | ||||
16 | 6 | 16/6 | 7 A @ 86° F | 0.46" | 1.67" | Black | Black, Blue, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 |
Power Cords
Connect equipment and devices to a power supply.
SJEOW cords have an oil- and water-resistant insulation.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 6 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
16 | 13 | 125V AC | 9 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 00000 |
NEMA 5-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 6 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 9 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
Coiled Power Cords
These self-coiling cords stretch to full length and then return to their retracted length for tangle-free storage. The industry designation is SJEOW, so the insulation resists oil and water.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Retracted Lg., ft. | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 7 | 125V AC | 1 | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
Extension Cords for Harsh Environments
The insulation resists water, oil, and chemicals, so these cords withstand dirty and greasy environments.
Cords with a power-indicating light have a light on the socket that illuminates when the cord has power.
Cords with TPE insulation stay flexible even in extreme temperatures as low as -90° F.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Color | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
10 ft. | |||||||||||
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 000000 |
Blue | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.63" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 16 | 13 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 15 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
25 ft. | |||||||||||
Black | 14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Black | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 00000 |
Blue | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.63" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue with White Stripe | 14 | 15 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 00000 |
Green | 14 | 15 | 125V AC | With Power-Indicating Light | 0.39" | Rubber | SJOW | -40° to 190° | UL Listed | 0000000 | 000000 |
Green | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJOW | -40° to 190° | UL Listed | 0000000 | 000000 |
Yellow | 16 | 13 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 15 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 10 | 15 | 125V AC | With Power-Indicating Light | 0.56" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
50 ft. | |||||||||||
Black | 14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Black | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 000000 |
Blue | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.63" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue with White Stripe | 14 | 15 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 00000 |
Green | 14 | 15 | 125V AC | With Power-Indicating Light | 0.39" | Rubber | SJOW | -40° to 190° | UL Listed | 0000000 | 000000 |
Green | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJOW | -40° to 190° | UL Listed | 0000000 | 000000 |
Yellow | 16 | 13 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 15 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 10 | 15 | 125V AC | With Power-Indicating Light | 0.56" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
100 ft. | |||||||||||
Black | 14 | 13 | 125V AC | With Power-Indicating Light | 0.36" | Elastomer Plastic | SJOOW | -40° to 140° | ETL Listed | 0000000 | 00000 |
Black | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 000000 |
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 000000 |
Blue | 16 | 10 | 125V AC | Without Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue | 14 | 13 | 125V AC | Without Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.63" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue with White Stripe | 14 | 13 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 000000 |
Green | 14 | 13 | 125V AC | With Power-Indicating Light | 0.39" | Rubber | SJOW | -40° to 190° | UL Listed | 0000000 | 000000 |
Green | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJOW | -40° to 190° | UL Listed | 0000000 | 000000 |
Yellow | 16 | 10 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 13 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Yellow | 10 | 15 | 125V AC | With Power-Indicating Light | 0.56" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Extension Cords for Welding
Run power to welders in machine shops, garages, and other areas where these cords will be exposed to harsh conditions. These cords have either EPDM or PVC insulation that protects the cord's wires from weld slag and being dragged, kicked, and stepped on. Their insulation also won't crack or become brittle when exposed to oil, water, and weather. They also stay flexible across a wide range of temperatures. A power-indicating light on the socket illuminates when the cord has power.
NEMA 5-15 cords are for use with most tools, such as angle grinders and hammer drills, rated up to 125V AC. With an additional layer of CPE on top of the EPDM, they withstand higher temperatures than cords insulated with TPE or PVC. Even in temperatures up to 190° F, they won’t degrade from chemicals or lose their toughness.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
25 ft. | ||||||||||
12 | 15 | 125V AC | With Power-Indicating Light | 0.43" | EPDM Rubber, CPE Rubber | SJOOW | UL Listed, CSA Certified | Black | 0000000 | 000000 |
50 ft. | ||||||||||
12 | 15 | 125V AC | With Power-Indicating Light | 0.43" | EPDM Rubber, CPE Rubber | SJOOW | UL Listed, CSA Certified | Black | 0000000 | 000000 |
100 ft. | ||||||||||
12 | 15 | 125V AC | With Power-Indicating Light | 0.43" | EPDM Rubber, CPE Rubber | SJOOW | UL Listed, CSA Certified | Black | 0000000 | 000000 |
Multi-Outlet Extension Cords for Harsh Environments
Insulated to resist water, oil, and solvents, these cords withstand dirty and greasy environments.
Cords with a power-indicating light have a light on the socket that illuminates when the cord has power.
SJEOOW cords are more durable than STOW and SEOW cords.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | No. of Outlets | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||||
25 | 3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
50 | 3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJOOW | UL Listed | Black | 0000000 | 00000 |
50 | 3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 00000 |
50 | 3 | 10 | 15 | 125V AC | With Power-Indicating Light | 0.59" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
100 | 3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
100 | 3 | 10 | 15 | 125V AC | With Power-Indicating Light | 0.59" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
Abrasion-Resistant Multi-Outlet Extension Cords
Thick insulation protects the internal wires of these cords, so they can be used in high-traffic areas and over rough surfaces.
Cords with a power-indicating light have a light on the socket that illuminates when the cord has power.
SJEOW cords have an oil- and water-resistant insulation.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
25 ft. | |||||||||||
3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
50 ft. | |||||||||||
3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 00000 |
100 ft. | |||||||||||
3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
Locking Extension Cords for Harsh Environments
Keep power flowing in dirty areas with rubber-insulated cords that resist oil, water, and chemicals. A locking lever on the socket prevents your device from disconnecting. The socket also has a power-indicating light that illuminates when the cord has power.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
25 ft. | ||||||||||
14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 000000 |
12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 00000 |
50 ft. | ||||||||||
14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 00000 |
12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 00000 |
10 | 15 | 125V AC | With Power-Indicating Light | 0.58" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
100 ft. | ||||||||||
14 | 13 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 000000 |
12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
10 | 15 | 125V AC | With Power-Indicating Light | 0.58" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
GFCI Turn-Lock Extension Cords
Keep personnel safe from electric shock with these cords. Give the connectors a quarter turn to lock in place; they remain secure in high-vibration applications. All have a manual GFCI reset that prevents unexpected equipment start-up.
For technical drawings and 3-D models, click on a part number.
Lg., ft. | Wire Gauge | Current, A | Voltage | GFCI Location | Reset Type | Power-Indicating Light | Cord Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA L6-30 Plug × NEMA L6-30 Socket | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
25 | 10 | 30 | 250V AC | Inline | Manual | With Power-Indicating Light | TPE Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 0000000 |