About Industry Designation for Cable Insulation
More
About Extension Cords
More
About Wire and Cable
More
Cable

Use this general purpose cable to supply power to equipment.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range:
Black: -40° to 220° F
Yellow: -55° to 220° F - Insulation: TPE Rubber
SJEOOW cable has an oil-resistant outer and inner insulation, and water-resistant outer insulation. The TPE rubber insulation also withstands chemicals.
Flame rated FT2 cable meets requirements for preventing the spread of flames based on a timed test with horizontally suspended material.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Specifications Met | Wire Material | Length, ft. | 1-249 | 250-Up | |
Stranded Wire—Black Outer Insulation | |||||||||||
18 | 2 | 18/2 | 10 A @ 86° F | 0.29" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 00000 | 00000 | |
18 | 3 | 18/3 | 10 A @ 86° F | 0.31" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 2 | 16/2 | 13 A @ 86° F | 0.31" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.33" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 000 | |
16 | 4 | 16/4 | 10 A @ 86° F | 0.35" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 2 | 14/2 | 18 A @ 86° F | 0.34" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.36" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 15 A @ 86° F | 0.39" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 2 | 12/2 | 25 A @ 86° F | 0.41" | Black, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.43" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.47" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.57" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 4 | 10/4 | 25 A @ 86° F | 0.63" | Black, Green, Red, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
Stranded Wire—Yellow Outer Insulation | |||||||||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.31" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 000 | 000 | |
16 | 3 | 16/3 | 13 A @ 86° F | 0.33" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 18 A @ 86° F | 0.37" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.43" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.57" | Black, Green, White | UL Listed, CSA Certified, UL 2556 FT2 | Bare Copper | 0000000 | 0000 | 0000 |
Coiled Cable

After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with hand tools and other portable devices.
SJOW, SOW, SJEOW, and SEOW cable have an oil- and water-resistant outer insulation. SJEOW and SEOW have a TPE rubber insulation that also withstands chemicals.
- Use For: Outdoors, Power Supply
- Flexible
- Temperature Range: 0° to 175° F
- Insulation: TPE Rubber
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | 6 ft. Retracted Lg. | 8 ft. Retracted Lg. | |
300V AC Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18 | 2 | 18/2 | 10 A @ 86° F | 0.31" | 1.1" | Black | Black, White | UL Listed, CSA Certified | 0000000 | ||||
18 | 3 | 18/3 | 10 A @ 86° F | 0.33" | 1.3" | Black | Black, Green, White | UL Listed, CSA Certified | 0000000 | ||||
18 | 4 | 18/4 | 7 A @ 86° F | 0.37" | 1.5" | Black | Black, Green, Red, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 2 | 16/2 | 13 A @ 86° F | 0.34" | 1.3" | Black | Black, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 3 | 16/3 | 13 A @ 86° F | 0.37" | 1.5" | Black | Black, Green, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 4 | 16/4 | 10 A @ 86° F | 0.4" | 1.6" | Black | Black, Green, Red, White | UL Listed, CSA Certified | 0000000 | ||||
16 | 5 | 16/5 | 8 A @ 86° F | 0.42" | 1.59" | Black | Black, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 | ||||
16 | 6 | 16/6 | 7 A @ 86° F | 0.46" | 1.67" | Black | Black, Blue, Green, Orange, Red, White | UL Listed, C-UL Listed | 0000000 |
Power Cords



Connect equipment and devices to a power supply.
SJEOW cords have an oil- and water-resistant insulation.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 1-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 6 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
16 | 13 | 125V AC | 9 | 0.31" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 00000 |
NEMA 5-15 Plug × Wire Leads | |||||||||||
16 | 13 | 125V AC | 6 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
16 | 13 | 125V AC | 9 | 0.33" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
14 | 15 | 125V AC | 9 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 00000000 | 00000 |
Coiled Power Cords


These self-coiling cords stretch to full length and then return to their retracted length for tangle-free storage. The industry designation is SJEOW, so the insulation resists oil and water.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Retracted Lg., ft. | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
NEMA 5-15 Plug × Wire Leads | ||||||||||||
18 | 7 | 125V AC | 1 | 6 | 0.38" | Rubber | SJEOW | -55° to 220° | UL Listed | Black | 0000000 | 000000 |
Extension Cords for Harsh Environments



The insulation resists water, oil, and chemicals, so these cords withstand dirty and greasy environments.
Cords with a power-indicating light have a light on the socket that illuminates when the cord has power.
Cords with TPE insulation stay flexible even in extreme temperatures as low as -90° F.
For technical drawings and 3-D models, click on a part number.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Color | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
10 ft. | |||||||||||
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 000000 |
Blue | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.36" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.39" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.45" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 16 | 13 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 15 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
25 ft. | |||||||||||
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 00000 |
Blue | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.36" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.39" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.45" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue with White Stripe | 14 | 15 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 00000 |
Yellow | 16 | 13 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 15 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 10 | 15 | 125V AC | With Power-Indicating Light | 0.56" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
50 ft. | |||||||||||
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 000000 |
Blue | 16 | 13 | 125V AC | Without Power-Indicating Light | 0.36" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 14 | 15 | 125V AC | Without Power-Indicating Light | 0.39" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.45" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue with White Stripe | 14 | 15 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 00000 |
Yellow | 16 | 13 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 15 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 10 | 15 | 125V AC | With Power-Indicating Light | 0.56" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
100 ft. | |||||||||||
Black | 10 | 15 | 125V AC | With Power-Indicating Light | 0.63" | TPE Rubber | SJEOW | -90° to 220° | UL Listed | 0000000 | 000000 |
Blue | 16 | 10 | 125V AC | Without Power-Indicating Light | 0.36" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue | 14 | 13 | 125V AC | Without Power-Indicating Light | 0.39" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue | 12 | 15 | 125V AC | Without Power-Indicating Light | 0.45" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Blue with White Stripe | 14 | 13 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 000000 |
Yellow | 16 | 10 | 125V AC | With Power-Indicating Light | 0.31" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 00000 |
Yellow | 14 | 13 | 125V AC | With Power-Indicating Light | 0.38" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Yellow | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Yellow | 10 | 15 | 125V AC | With Power-Indicating Light | 0.56" | Rubber | SJEOW | -55° to 190° | UL Listed | 0000000 | 000000 |
Multi-Outlet Extension Cords for Harsh Environments



Insulated to resist water, oil, and solvents, these cords withstand dirty and greasy environments.
Cords with a power-indicating light have a light on the socket that illuminates when the cord has power.
SJEOOW cords are more durable than STOW and SEOW cords.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | No. of Outlets | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||||
25 | 3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
50 | 3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 00000 |
50 | 3 | 10 | 15 | 125V AC | With Power-Indicating Light | 0.59" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
100 | 3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.44" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
100 | 3 | 10 | 15 | 125V AC | With Power-Indicating Light | 0.59" | Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 000000 |
Abrasion-Resistant Multi-Outlet Extension Cords



Thick insulation protects the internal wires of these cords, so they can be used in high-traffic areas and over rough surfaces.
Cords with a power-indicating light have a light on the socket that illuminates when the cord has power.
SJEOW cords have an oil- and water-resistant insulation.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
25 ft. | |||||||||||
3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
50 ft. | |||||||||||
3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 00000 |
100 ft. | |||||||||||
3 | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
Locking Extension Cords for Harsh Environments



Keep power flowing in dirty areas with rubber-insulated cords that resist oil, water, and chemicals. A locking lever on the socket prevents your device from disconnecting. The socket also has a power-indicating light that illuminates when the cord has power.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
25 ft. | ||||||||||
14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 000000 |
12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 00000 |
50 ft. | ||||||||||
14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 00000 |
12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 00000 |
10 | 15 | 125V AC | With Power-Indicating Light | 0.58" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
100 ft. | ||||||||||
14 | 13 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 000000 |
12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
10 | 15 | 125V AC | With Power-Indicating Light | 0.58" | Rubber | SJEOW | UL Listed | Blue with Orange Stripe | 0000000 | 000000 |
GFCI Turn-Lock Extension Cords
Keep personnel safe from electric shock with these cords. Give the connectors a quarter turn to lock in place; they remain secure in high-vibration applications. All have a manual GFCI reset that prevents unexpected equipment start-up.
For technical drawings and 3-D models, click on a part number.


Lg., ft. | Wire Gauge | Current, A | Voltage | GFCI Location | Reset Type | Power-Indicating Light | Cord Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA L6-30 Plug × NEMA L6-30 Socket | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
25 | 10 | 30 | 240V AC | Inline | Manual | With Power-Indicating Light | TPE Rubber | SJEOOW | UL Listed | Yellow | 0000000 | 0000000 |