Space-Saver Stairs
Also known as ship's ladders, these stairs have a 75° climbing angle to fit in pits, trenches, wells, and other tight spaces. Handrails extend 42" beyond the top landing for a walk-through exit. Steps are perforated for good slip resistance.
Note: Stairs meet OSHA dimensional standards. Users are responsible for checking local, state, and federal codes, including OSHA, for safe installation and operating practices.
Stairs | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Step | Handrail | Replacement Handrails | ||||||||||||||
Landing Ht. (A) | Wd. | Dp. (B) | Climbing Angle | No. of Steps | Dp. | Tread | Top Step Dp. | Cap., lbs. | Ht. | Color | Mounting Hardware Included | Assembled or Unassembled | Specifications Met | Each | Each | ||
Galvanized Steel | |||||||||||||||||
24" Wide Steps | |||||||||||||||||
3'8" to 4'7 1/2" | 29" | 23" | 75° | 4 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 0000000 | 000000 | 000000 |
4'7 1/2" to 5'7" | 29" | 26" | 75° | 5 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
5'7" to 6'6" | 29" | 29" | 75° | 6 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
6'6" to 7'6" | 29" | 32" | 75° | 7 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
7'6" to 8'6" | 29" | 35" | 75° | 8 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 000000 | 000000 | 0000000 | 000000 |
8'6" to 9'5" | 29" | 38" | 75° | 9 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
9'5" to 10'5" | 29" | 41" | 75° | 10 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
10'5" to 11'5" | 29" | 44" | 75° | 11 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
30" Wide Steps | |||||||||||||||||
3'8" to 4'7 1/2" | 35" | 23" | 75° | 4 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
4'7 1/2" to 5'7" | 35" | 26" | 75° | 5 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
5'7" to 6'6" | 35" | 29" | 75° | 6 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 000000 | 00000 |
6'6" to 7'6" | 35" | 32" | 75° | 7 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
7'6" to 8'6" | 35" | 35" | 75° | 8 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
8'6" to 9'5" | 35" | 38" | 75° | 9 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 | 0000000 | 000000 |
9'5" to 10'5" | 35" | 41" | 75° | 10 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
10'5" to 11'5" | 35" | 44" | 75° | 11 | 7" | Perforated | 12" | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3277, OSHA Compliant 29 CFR 1910.23 | 0000000 | 00000000 | 0000000 | 000000 |
Forward Descent Space-Saver Stairs
These stairs have offset steps that allow for a comfortable forward descent. Set at a steeper angle than our standard stairs, they require less floor space. Steps are perforated for good slip resistance.
Note: Stairs meet OSHA dimensional standards. Users are responsible for checking local, state, and federal codes, including OSHA, for safe installation and operating practices.
Also Available: Other landing heights (dimension A) from 3 1/2 feet up to 20 feet. Please select 7946T9 and specify height in inches. To determine the price, multiply your landing height in inches by $20.20 and add $362.28.
Overall | Step | Handrail | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Landing Ht. (A), ft. | Wd. | Dp. (B) | Climbing Angle | No. of Steps | Dp. | Tread | Cap., lbs. | Ht. | Color | Mounting Hardware Included | Assembled or Unassembled | Specifications Met | Each | |
Yellow Powder-Coated Steel | ||||||||||||||
9" Wide Steps | ||||||||||||||
4 | 23" | 26" | 68° | 6 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 000000000 |
5 | 23" | 31" | 68° | 7 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
6 | 23" | 36" | 68° | 8 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
7 | 23" | 40" | 68° | 10 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
8 | 23" | 45" | 68° | 11 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
9 | 23" | 50" | 68° | 12 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
10 | 23" | 55" | 68° | 14 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
11 | 23" | 60" | 68° | 15 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
12 | 23" | 65" | 68° | 16 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
13 | 23" | 70" | 68° | 18 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
14 | 23" | 74" | 68° | 19 | 10 1/2" | Perforated | 600 | 42" | Yellow | No | Unassembled | OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28, Cal/OSHA Compliant Title 8 Section 3234, NFPA 101 7.2.11, ANSI/ASSE A1264.1 | 0000000 | 00000000 |
Top-Mount Stairs
Mount these stairs to an elevated landing for easy access. They have adjustable mounting brackets to accommodate slight differences in landing heights. Steps are perforated to provide slip resistance that’s easy on your shoes.
Stairs that meet OSHA standards are intended for use in private facilities, such as factories and other industrial settings. Set at a steeper angle than IBC (International Building Code) stairs, they require less floor space.
Stairs that meet IBC standards are used in commercial buildings that may be accessed by the general public. With larger step dimensions and a shallower angle than OSHA stairs, they are easier to climb. In addition, the vertical space between steps is covered to prevent debris from falling through.
Note: Stairs meet OSHA or IBC dimensional standards. Users are responsible for checking local, state, and federal codes, including OSHA or IBC, for safe installation and operating practices.
Overall | Step | Handrail | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Landing Ht. (A) | Wd. | Dp. (B) | Climbing Angle | No. of Steps | Dp. | Tread | Cap., lbs. | Ht. | Color | Mounting Hardware Included | Assembled or Unassembled | Specifications Met | Each | |
Galvanized Steel | ||||||||||||||
30" Wide Steps | ||||||||||||||
3'2" to 3'8" | 43" | 3'3" to 3'7" | 35°-42° | 4 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 000000000 |
3'11" to 4'5" | 43" | 4'0" to 4'5" | 35°-42° | 5 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
4'6" to 5'1" | 43" | 5'0" to 5'4" | 35°-42° | 6 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
5'2" to 5'9" | 43" | 5'9" to 6'3" | 35°-42° | 7 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
5'10" to 6'6" | 43" | 6'7" to 7'1" | 35°-42° | 8 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
6'7" to 7'2" | 43" | 7'6" to 7'11" | 35°-42° | 9 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
7'3" to 7'11" | 43" | 8'3" to 8'9" | 35°-42° | 10 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
8'0" to 8'8" | 43" | 9'1" to 9'7" | 35°-42° | 11 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
8'9" to 9'5" | 43" | 9'11" to 10'5" | 35°-42° | 12 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
9'6" to 10'10" | 43" | 11'7" to 12'6" | 35°-42° | 14 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
36" Wide Steps | ||||||||||||||
3'0" to 3'6" | 47" | 4'8" to 4'11" | 28°-33° | 5 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
3'2" to 3'8" | 49" | 3'3" to 3'7" | 35°-42° | 4 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
3'7" to 4'0" | 47" | 5'7" to 5'11" | 28°-33° | 6 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
3'11" to 4'5" | 49" | 4'0" to 4'5" | 35°-42° | 5 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
4'1" to 4'7" | 47" | 6'6" to 6'10" | 28°-33° | 7 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
4'8" to 5'1" | 47" | 7'5" to 7'10" | 28°-33° | 8 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
5'2" to 5'9" | 49" | 5'9" to 6'3" | 35°-42° | 7 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
5'2" to 5'10" | 47" | 8'4" to 8'10" | 28°-33° | 9 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
6'0" to 7'0" | 47" | 10'1" to 10'9" | 28°-33° | 11 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
7'1" to 8'2" | 47" | 12'0" to 12'9" | 28°-33° | 13 | 11" | Perforated | 1,800 | 43 1/2" | Yellow | No | Unassembled | IBC Standards | 0000000 | 00000000 |
8'0" to 8'8" | 49" | 9'1" to 9'7" | 35°-42° | 11 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |
9'6" to 10'10" | 49" | 11'7" to 12'6" | 35°-42° | 14 | 9 1/2" | Perforated | 1,800 | 42" | Yellow | No | Unassembled | Cal/OSHA Compliant Title 8 Section 3214, Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 00000000 |