About Sump, Water-Removal, Condensate, and Submersible Pumps
More
How to Prime Your Pump
More
How to Determine Feet of Head
More
Submersible Pumps for Water





Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | Plug | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 6 | 3 5/8" | 2 7/8" | 3 1/2" | 0000000 | 0000000 |
A | Plug | 5 | 4 | 2.2 | 12.2 | 35° to 120° | 1/40 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4 1/4" | 2 7/8" | 4 7/8" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
B | Plug | 5.6 | 4.3 | 0.8 | 11.1 | 35° to 85° | 1/15 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4" | 3 7/8" | 5 3/8" | 0000000 | 000000 |
B | Plug | 8.9 | 6.9 | 2.5 | 13 | 35° to 85° | 1/10 hp | 1.2 | Screened | 1/2 | NPT | Male | 6 | 4 1/2" | 4" | 5 5/8" | 0000000 | 000000 |
115V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||
B | Plug | 3.5 | 1.5 | __ | 7.1 | 35° to 85° | 1/25 hp | 0.5 | Screened | 1/4 | NPT | Male | 6 | 3 7/8" | 3 1/2" | 4 5/8" | 0000000 | 00000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Plug | 3.5 | 2.5 | __ | 10.2 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 18 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Hardwire | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 0.7 | Screened | 1/4 | NPT | Male | 12 | 4 5/8" | 5" | 5" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
D | Plug | 7.9 | 6.6 | 3.4 | 13.4 | 35° to 120° | 1/28 hp | 1.4 | Screened | 3/8 | NPT | Male | 6 | 4" | 4" | 4 5/8" | 0000000 | 0000000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
E | Plug | 20 | 12 | 4 | 15 | 35° to 85° | 1/15 hp | 1 | Screened | 3/4 | NPT | Male | 15 | 5 1/4" | 3 3/4" | 6 3/8" | 00000000 | 0000000 |
Submersible/Open-Air Pumps for Water

These pumps can be submerged or connected remotely to a pipe in your line. Use them to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
2.8 | 1.7 | 7 | 35° to 120° | 1/125 hp | 0.6 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 3 3/8" | 3 3/4" | 2 3/4" | 0000000 | 0000000 |
Impact-Resistant Submersible Pumps for Water


The durable epoxy-coated aluminum housing handles hard knocks in rough waters. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
A | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/200 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 3.5 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 0.4 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 1.6 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 0000000 | 000000 |
Impact-Resistant Submersible/Open-Air Pumps for Water


Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Features | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 1.1 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 4 1/8" | 4 5/8" | __ | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 000000 | 000000 |
B | 8.3 | 5.6 | 3.5 | 17.3 | 35° to 120° | 1/15 hp | 3.2 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 0.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 0000000 | 000000 |
B | 10 | 8.6 | 6.9 | 21 | 35° to 120° | 1/15 hp | 1.4 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 0000000 | 000000 |
Extended-Life Submersible/Open-Air Pumps for Water

These pumps can be submerged or connected remotely to a pipe in your line. Magnets turn the impeller so there's no shaft seal to wear out. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube ID | Tube Connection Type | For Tube ID | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug | 2.3 | 2 | 1.5 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 3/8" | Barbed | 3/8" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 1/2" | Barbed | 1/2" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 000000 |
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | 1/4 | NPT | Male | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
Extended-Life Submersible Pumps for Water

Magnets turn the impeller so there's no shaft seal to wear out. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Screened | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 3 7/8" | 0000000 | 0000000 |
Submersible Pumps for Chemicals


These pumps circulate solvent-based parts-washing solutions. Submerge in solutions that are UL classified as PJQU (flash point no lower than 100° F). Pumps must be wired to a plug (not included) to activate. Do not run dry. Not for use in heated parts washer applications.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 3 Ft. of Head | @ 5 Ft. of Head | @ 7 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
A | 5 | 4.3 | 3.4 | 2.5 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 0000000 | 0000000 |
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 000000 |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
A | 2.8 | 2.3 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 4 1/4" | 2 3/4" | 3 1/4" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 0.6 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 000000 |
Submersible Pumps for Salt Water

Circulate salt water in submerged and open-air applications. These pumps use magnets to turn the impellers so there is no shaft seal to wear out. They must be wired to a plug (not included) to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
5 | 3.8 | 13 | 35° to 130° | 1/50 hp | 0.9 | 3/8 × 3/4 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 6 1/8" | 4 7/8" | 00000000 | 0000000 |
8.5 | 8 | 19 | 35° to 130° | 1/20 hp | 2 | 3/4 | NPT | Female | 1/2 | NPT | Male | 4 7/8" | 7 3/8" | 4 3/4" | 00000000 | 000000 |
Clog-Resistant Sump Pumps for Water

The intake is 2” from the base of the pump to prevent dirt at the bottom of your sump pit from clogging the pump. The float switch is wired to the pump. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 8 ft. Cord | ||||||||||||||||||
57 | 45 | 28 | 18 | 9" | 4" | 40° to 120° | 1/3 hp | 3.8 | 1 1/2 | NPT | Female | 11" | 18" | 12" | 10" | 8" | 0000000 | 0000000 |
65 | 52 | 35 | 20 | 9" | 4" | 40° to 120° | 1/2 hp | 4 | 1 1/2 | NPT | Female | 11" | 18" | 12" | 10" | 8" | 0000000 | 000000 |
81 | 66 | 49 | 22 | 9" | 4" | 40° to 120° | 1 hp | 9.8 | 1 1/2 | NPT | Female | 11" | 18" | 12" | 10" | 8" | 0000000 | 000000 |
Sump Pumps without Switch for Water

These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Pumps remove accumulated water from sump pits, loading docks, and cooling towers. They have a cast iron housing that stands up to demanding environments. Use with debris-free water. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||
46 | 29 | 13 | 18 | 35° to 120° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 8" | 10" | 8" | 0000000 | 0000000 |
Plug with 25 ft. Cord | ||||||||||||||||
46 | 29 | 13 | 18 | 35° to 120° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 8" | 10" | 8" | 0000000 | 000000 |
Extended-Life Pressure-Activated Sump Pumps for Water

Since the switch activates on increasing pressure caused by rising water levels, these pumps have no external moving parts to catch on sump pit walls. Use them to remove accumulated water from sump pits, loading docks, and cooling towers. With cast iron housing, these pumps can stand up to demanding environments. They should be used with debris-free water. Submerge while in use and do not run dry.
Switch maintenance kits (sold separately) include a bracket, a diaphragm O-ring, a screw, and a switch.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Housing Material | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||||
46 | 29 | 13 | 18 | Cast Iron | 10" | 4" | 35° to 120° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 6" | 10" | 9" | 0000000 | 0000000 |
Switch Maintenance Kit | 0000000 | Each | 000000 |
Sump Pumps with Basin for Water
Convenient for applications where a sump pit is impractical, these pumps include a basin with a vent on top. Pumps have a switch that activates on increasing pressure caused by rising water levels. Use with debris-free water.

Max. Flow Rate, gpm | Level | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Turn On | Turn Off | Cap., gal. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
46 | 29 | 12 | 18 | 7" | 3" | 3 1/2 | 35° to 125° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 11" | 15" | 15" | 00000000 | 0000000 |
46 | 29 | 12 | 18 | 10" | 4" | 5 | 35° to 125° | 1/3 hp | 9 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 16" | 15" | 15" | 00000000 | 000000 |
Sump Pumps for Sewage Water with Replaceable Float Switch

The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Equipped with a large intake and rugged impeller, these pumps transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 19" | 11" | 35° to 140° | 2/5 hp | 8 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 0000000 |
120 | 100 | 80 | 25 | 2" | 19" | 11" | 35° to 140° | 1/2 hp | 11 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 000000 |
Float-Switch Activated Sump Pumps for Sewage Water

Equipped with a large intake and a rugged impeller, this pump transfers raw sewage water with solids up to 2" in diameter. It has a cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 13" | 8" | 35° to 140° | 4/10 hp | 8 | Open | 2 | NPT | Female | 18" | 30" | 14 1/2" | 11" | 9" | 00000000 | 0000000 |
Sump Pumps with Basin for Sewage Water

Convenient for applications where a sump pit is impractical, these pumps include a basin with a vent on top. They handle raw sewage water with solids up to 2" in diameter. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump.
Max. Flow Rate, gpm | Level | Discharge | O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Feet of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Cap., gal. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
125 | 100 | 65 | __ | 20 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 2/5 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 0000000 |
140 | 119 | 91 | 55 | 24 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 1/2 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 000000 |
144 | 126 | 105 | 74 | 28 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 3/4 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 00000000 |
Compact Water-Removal Pumps
Also known as bilge pumps, these remove fresh and salt water from spots where other pumps don’t fit. They have an internal sensor, so they turn on when they detect water and turn off when the water is removed. Pumps are fully submersible. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on.
Pumps for 12 volts DC work with 12-volt batteries.
Pumps for 120 volts AC are for use in debris-free water.

Max. Flow Rate, gpm | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current, A | For Tube ID | Gender | Dia. | Ht. | Each | |
ABS Plastic Housing | |||||||||||||
Hardwire with 2 ft. Cord | |||||||||||||
5 | 1 | 11 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 1.6 | 3/4" | Male | 3" | 4" | 0000000 | 000000 |
10 | 3 | 10 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 3.7 | 1", 1 1/8" | Male | 3" | 5" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current | Pipe Size | Thread Type | Gender | Dia. | Ht. | Includes | Each | |
ABS Plastic Housing | |||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 0000000 |
Plug with 24 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 000000 |
Heavy Duty Battery-Operated Water-Removal Pumps

This pump has an impact-resistant aluminum housing and handles larger solids than other battery-operated water-removal pumps. Attach it to a 12-volt battery to remove water in locations without power. Pump is gravity fed and requires an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Discharge | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 Ft. of Head, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Ht. | Each | |
12V DC—With Thermal Overload Protection | |||||||||||||
41 | 20 | 1/4" | 1/4" | 35° to 190° | 1/3 hp | 30 | 1 1/2 | NPT | Female | 9 37/64" | 22 3/64" | 000000 | 000000000 |
Steel Drums
All drums are UN-compliant for shipping.

Cap., gal. | Dia. | Ht. | Bottom ID | Gauge | Weight Cap., lbs. | Color | Seal Material | Closing Ring Material | Space Saving Features | Shipping Standard | Each | |
Painted Steel | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
30 | 19 1/2" | 29" | 18 1/4" | 18 | 500 | Black | EPDM Rubber | Steel | Stackable | UN1A2/X235/S, UN1A2/Y1.5/150 | 0000000 | 0000000 |
16 | 15" | 27 1/4" | 14" | 20 | 425 | Black | EPDM Rubber | Steel | Stackable | UN1A2/X200/S, UN1A2/Y1.5/150 | 0000000 | 000000 |
Replacement Parts for Parts Washers
Replace parts such as pumps, hose, and fusible links on your parts washer.

For Manufacturer | For Manufacturer Model No. | Each | |
Fountain | CleanMaster 200, CleanMaster 230, CleanMaster 440, EcoMaster 230S, EcoMaster 235 | 0000000 | 0000000 |

For Manufacturer | For Manufacturer Model No. | Lg. | Each | |
Metal | ||||
---|---|---|---|---|
Fountain | CleanMaster 230 | 15" | 0000000 | 000000 |
Graymills | Handi-Kleen PL36-A, Handi-Kleen PL36-FB, Solvent Drum Mount DMS232, Solvent Drum Mount DMS236, Solvent Drum Mount DMD232, Solvent Drum Mount DMD236, Handi-Kleen PL36-GG, Handi-Kleen PL364-A | 30" | 0000000 | 00000 |

For Manufacturer | For Manufacturer Model No. | Each | |
Fusible Link | |||
---|---|---|---|
Graymills | Handi-Kleen PL36-A, Handi-Kleen PL36-GG | 0000000 | 000000 |