Choosing a Proximity Switch
More
Time-Delay Fiber-Optic Photoelectric Switches
Set these switches to delay activation by up to fifteen seconds after detecting an object. They have a highly flexible fiber-optic cable and small sensing end, making it easy to position these switches in hard to reach areas. They detect the presence or absence of an object moving at high speeds with a light beam. Adjust the intensity of the light beam to better detect shiny or translucent objects. The fiber-optic cable can be cut to length. All are rated NEMA 6P and IP67 for protection from corrosion, washdowns and temporary submersion.
Direct sensing switches detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
Receiver switches detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing switches.
For technical drawings and 3-D models, click on a part number.
Switches | Replacement Cables | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Beam Switch Operation | Max. Sensing Distance | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Input Voltage | Features | Timer Relay Function | Lg. | Wd. | Ht. | Conduit Trade Size | Each | Each | ||
With Wire Leads | |||||||||||||||
Direct Sensing Switches with Visible Light Beam | |||||||||||||||
On When Object Absent/On When Object Present | 1.8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 5 A @ 250 V AC, 5 A @ 30 V DC | 24V AC-250V AC/12V DC-250V DC | Relay, LED Alignment and Signal Strength Indicator | Delayed Off Delayed Start (Delay-on-Make) Interval Repeat Cycle Switch-On (Single-Shot) | 2 1/8" | 1 3/4" | 2 3/4" | 1/2 | 00000000 | 0000000 | 00000000 | 000000 |
Receiver Switches with Visible Light Beam | |||||||||||||||
On When Object Absent/On When Object Present | 4.9" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 5 A @ 250 V AC, 5 A @ 30 V DC | 24V AC-250V AC/12V DC-250V DC | Relay, LED Alignment and Signal Strength Indicator | Delayed Off Delayed Start (Delay-on-Make) Interval Repeat Cycle Switch-On (Single-Shot) | 2 1/8" | 1 3/4" | 2 3/4" | 1/2 | 00000000 | 000000 | 00000000 | 00000 |
Fiber-Optic Photoelectric Switches
The highly flexible fiber-optic cable and small sensing end make it easy to position these switches in hard to reach areas. They detect the presence or absence of an object moving at high speeds with a light beam. Adjust the intensity of the light beam to better detect shiny or translucent objects. The fiber-optic cable can be cut to length. All are rated NEMA 6P and IP67 for protection from corrosion, washdowns and temporary submersion.
Direct sensing switches detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
Receiver switches detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing switches.
For technical drawings and 3-D models, click on a part number.
Switches | Replacement Cables | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Beam Switch Operation | Max. Sensing Distance | Switch Starting Position | Industry Designation | Switching Current @ Voltage | Input Voltage | Features | Housing Material | Conduit Trade Size | Temp. Range, °F | Each | Each | ||
With Wire Leads | |||||||||||||
Direct Sensing Switches with Visible Light Beam | |||||||||||||
On When Object Absent/On When Object Present | 1.8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 5 A @ 250 V AC, 5 A @ 30 V DC | 24V AC-250V AC/12V DC-250V DC | Relay, LED Alignment and Signal Strength Indicator | Plastic | 1/2 | -10° to 130° | 00000000 | 0000000 | 00000000 | 000000 |
Receiver Switches with Visible Light Beam | |||||||||||||
On When Object Absent/On When Object Present | 4.9" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 5 A @ 250 V AC, 5 A @ 30 V DC | 24V AC-250V AC/12V DC-250V DC | Relay, LED Alignment and Signal Strength Indicator | Plastic | 1/2 | -10° to 130° | 00000000 | 000000 | 00000000 | 00000 |
DC Metallic-Object Proximity Switches
Micro
M12 Plug
Also known as inductive proximity switches, these detect metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. Sensing distance is based on the target material. The distance listed is for mild steel. They’re often used with programmable logic controllers (PLCs) and produce PNP or NPN signal output. To determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included).
Flush switches, also known as embeddable or shielded switches, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting switches at close range and can be mounted close together without causing interference. Projecting switches, also known as non-embeddable or unshielded switches, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches with the same diameter.
Switches with a plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the switch.
Switches with IO link can be configured remotely when connected to a PLC, a human-machine interface (HMI), or a computer.
IP67 and IP68 rated switches are protected from temporary submersion. NEMA 6P rated switches are protected from corrosion and washdowns.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
For technical drawings and 3-D models, click on a part number.
Switches | Cables with Sockets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | No. of Wire Leads | Lg., mm | Circuit Protection | Cable Lead Lg., ft. | Temperature Range, °F | Each | Each | ||
Nickel-Plated Brass Housing with Plastic Face (IP67 and NEMA 6P) | ||||||||||||||
Flush with 4-Pole Micro M12 Plug | ||||||||||||||
1 Off (Normally Open) | 12 | 4 | NPN | 10V DC-30V DC | 200mA | __ | 45 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 00000000 | 000000 | 0000000 | 000000 |
1 Off (Normally Open) | 18 | 5 | NPN | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 30 | 10 | NPN | 10V DC-30V DC | 200mA | __ | 48.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 On (Normally Closed) | 18 | 5 | NPN | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
Flush with 4-Pole Micro M12 Plug and IO Link | ||||||||||||||
1 Off (Normally Open) | 12 | 4 | PNP | 10V DC-30V DC | 200mA | __ | 45 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 00000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 18 | 5 | PNP | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 30 | 10 | PNP | 10V DC-30V DC | 200mA | __ | 48.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 On (Normally Closed) | 12 | 2 | PNP | 10V DC-30V DC | 200mA | __ | 60 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 00000000 | 00000 | 0000000 | 00000 |
1 On (Normally Closed) | 18 | 5 | PNP | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
Projecting with 4-Pole Micro M12 Plug | ||||||||||||||
1 Off (Normally Open) | 12 | 4 | NPN | 10V DC-30V DC | 200mA | __ | 60 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 00000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 18 | 8 | NPN | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 30 | 15 | NPN | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 On (Normally Closed) | 12 | 4 | NPN | 10V DC-30V DC | 200mA | __ | 60 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 00000000 | 00000 | 0000000 | 00000 |
Projecting with 4-Pole Micro M12 Plug and IO Link | ||||||||||||||
1 Off (Normally Open) | 12 | 4 | PNP | 10V DC-30V DC | 200mA | __ | 60 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 00000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 18 | 8 | PNP | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 Off (Normally Open) | 30 | 15 | PNP | 10V DC-30V DC | 200mA | __ | 63.5 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 0000000 | 00000 | 0000000 | 00000 |
1 On (Normally Closed) | 12 | 4 | PNP | 10V DC-30V DC | 200mA | __ | 60 | Overload Reverse Polarity Short Circuit | __ | -10° to 155° | 00000000 | 00000 | 0000000 | 00000 |
Stainless Steel Housing with Plastic Face (IP67 and NEMA 6P) | ||||||||||||||
Projecting with Wire Leads and IO Link | ||||||||||||||
1 On (Normally Closed) | 8 | 2.5 | PNP | 10V DC-30V DC | 200mA | 3 | 35 | Overload Reverse Polarity Short Circuit | 6 1/2 | -10° to 155° | 00000000 | 00000 | 000000 | 00 |
DC Metallic-Object Proximity Switches for Long Distances
Micro
M12 Plug
Sense objects from farther away than with other proximity switches that have the same diameter. Also known as inductive proximity switches, they remotely sense metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. Sensing distance is based on the type of material being sensed. The distance listed is for mild steel. They’re often used with programmable logic controllers (PLCs) and produce PNP signal output. Some automatically sense whether PNP or NPN signal output is needed.
Flush switches, also known as embeddable or shielded switches, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting switches at close range and can be mounted close together without causing interference.
Projecting switches, also known as non-embeddable or unshielded switches, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches with the same diameter.
Switches with a 4-pole Micro M12 plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the switch.
All are rated IP69K for protection from high-temperature, high-pressure washdowns. Some are also rated NEMA 6P, 13, and IP67 for protection from corrosion, oil/coolant spraying, and temporary submersion.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
For technical drawings and 3-D models, click on a part number.
Switches | Cables with Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | Max. Sensing Distance, mm | Dia., mm | Signal Output Type | Input Voltage | No. of Wire Leads | Lg., mm | Cable Lead Lg., ft. | Temperature Range, °F | Environmental Rating | Each | Each | ||
Stainless Steel Housing with Plastic Face | |||||||||||||
Flush with Wire Leads | |||||||||||||
1 Off (Normally Open) | 8 | 18 | PNP/NPN | 6V DC-48V DC | 3 | 66 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 0000000 | 000000 | 00 |
1 Off (Normally Open) | 15 | 30 | PNP/NPN | 6V DC-48V DC | 3 | 71 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 000000 | 00 |
Flush with 4-Pole Micro M12 Plug | |||||||||||||
1 Off (Normally Open) | 4 | 12 | PNP/NPN | 6V DC-48V DC | __ | 77 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 0000000 | 000000 |
1 Off (Normally Open) | 8 | 18 | PNP/NPN | 6V DC-48V DC | __ | 69 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) | 15 | 30 | PNP/NPN | 6V DC-48V DC | __ | 74 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 0000000 | 00000 |
Projecting with Wire Leads | |||||||||||||
1 Off (Normally Open) | 10 | 12 | PNP/NPN | 6V DC-48V DC | 3 | 73 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 000000 | 00 |
1 Off (Normally Open) | 16 | 18 | PNP/NPN | 6V DC-48V DC | 3 | 66 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 000000 | 00 |
1 Off (Normally Open) | 29 | 30 | PNP/NPN | 6V DC-48V DC | 3 | 71 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 000000 | 00 |
Projecting with 4-Pole Micro M12 Plug | |||||||||||||
1 Off (Normally Open) | 10 | 12 | PNP/NPN | 6V DC-48V DC | __ | 77 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) | 16 | 18 | PNP/NPN | 6V DC-48V DC | __ | 69 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) | 29 | 30 | PNP/NPN | 6V DC-48V DC | __ | 74 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 0000000 | 00000 |
Projecting with 4-Pole Micro M12 Plug, Computer Cord, and Software | |||||||||||||
1 Off (Normally Open) | 10 | 12 | PNP/NPN | 6V DC-48V DC | __ | 77 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | 0000000 | 000000 | 0000000 | 00000 |
AC Metallic-Object Proximity Switches for Long Distances
Micro
M12 Plug
Sense objects from farther away than with other proximity switches that have the same diameter. Also known as inductive proximity switches, they remotely sense metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. Sensing distance is based on the type of material being sensed. The distance listed is for mild steel. All are rated NEMA 6P, 13, IP67 and IP69K.
Flush switches, also known as embeddable or shielded switches, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting switches at close range and can be mounted close together without causing interference.
Projecting switches, also known as non-embeddable or unshielded switches, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush switches with the same diameter.
Switches with a 3-pole Micro M12 plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the switch.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number
For technical drawings and 3-D models, click on a part number.
Switches | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Input Voltage | Current Output | No. of Wire Leads | Lg., mm | Cable Lead Lg., ft. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | Each | ||
Stainless Steel Housing with Plastic Face | ||||||||||||||
Flush with Wire Leads | ||||||||||||||
1 Off (Normally Open) | 12 | 4 | 20V AC-132V AC | 200mA | 2 | 73 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 0000000 | 000000 | 00 |
1 Off (Normally Open) | 18 | 8 | 20V AC-132V AC | 200mA | 2 | 66 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 000000 | 00 |
1 Off (Normally Open) | 30 | 15 | 20V AC-132V AC | 200mA | 2 | 71 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 000000 | 00 |
Flush with 3-Pole Micro M12 Plug | ||||||||||||||
1 Off (Normally Open) | 12 | 4 | 20V AC-132V AC | 200mA | __ | 77 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 000000 | 00 |
1 Off (Normally Open) | 18 | 8 | 20V AC-132V AC | 200mA | __ | 69 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 0000000 | 000000 |
1 Off (Normally Open) | 30 | 15 | 20V AC-132V AC | 200mA | __ | 74 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
Projecting with Wire Leads | ||||||||||||||
1 Off (Normally Open) | 12 | 10 | 20V AC-132V AC | 200mA | 2 | 73 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 000000 | 00 |
1 Off (Normally Open) | 18 | 18 | 20V AC-132V AC | 200mA | 2 | 66 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 000000 | 00 |
1 Off (Normally Open) | 30 | 29 | 20V AC-132V AC | 200mA | 2 | 71 | 6 1/2 | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 000000 | 00 |
Projecting with 3-Pole Micro M12 Plug | ||||||||||||||
1 Off (Normally Open) | 12 | 10 | 20V AC-132V AC | 200mA | __ | 77 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) | 18 | 18 | 20V AC-132V AC | 200mA | __ | 69 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
1 Off (Normally Open) | 30 | 29 | 20V AC-132V AC | 200mA | __ | 74 | __ | -40° to 155° | NEMA 6P, NEMA 13, IP67, IP69K | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
Harsh Environment DC Universal-Object Proximity Switches
Micro
M12 Plug
Rated NEMA 6P, 12, IP68 and IP69K, these switches protect against corrosion and high-pressure, high-temperature washdowns. Also known as capacitive proximity switches, they remotely sense both metallic and nonmetallic objects but their strength is in sensing materials such as plastic, ceramic, and clear targets. They’re often used with programmable logic controllers (PLCs) and produce PNP or NPN signal output. To determine the signal output of a switch you are replacing, use Testers for Proximity and Photoelectric Switches (not included). They mount flush with the surface of any material, including metal, and are also known as embeddable or shielded switches. The 4-pole Micro M12 plug connects to cables with sockets (sold separately), allowing you to quickly connect and disconnect the switch.
Also available: If you don’t see the switch you need, please select 6693T999 and specify manufacturer and manufacturer part number.
For technical drawings and 3-D models, click on a part number.
Switch Starting Position | Dia., mm | Max. Sensing Distance, mm | Signal Output Type | Input Voltage | Current Output | Lg., mm | Circuit Protection | Temperature Range, °F | Environmental Rating | Each | |
Plastic Housing with Plastic Face | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
With 4-Pole Micro M12 Plug | |||||||||||
1 Off (Normally Open) and 1 On (Normally Closed) | 30 | 16 | PNP | 10V DC-40V DC | 200mA | 61 | Reverse Polarity Short Circuit | -20° to 185° | NEMA 6P, NEMA 12, IP68, IP69K | 0000000 | 0000000 |
1 Off (Normally Open) and 1 On (Normally Closed) | 30 | 16 | NPN | 10V DC-40V DC | 200mA | 61 | Reverse Polarity Short Circuit | -20° to 185° | NEMA 6P, NEMA 12, IP68, IP69K | 0000000 | 000000 |
Cable with Socket | 0000000 | Each | 000000 |