About NEMA Straight-Blade Plugs, Connectors, and Receptacles
More
About NEMA Plugs, Sockets, and Receptacles
More
Choosing an Electrical Switch
More
Moisture-Resistant Insulation-Piercing Butt Splices
Connect wire without stripping—these splices pierce the insulation for quick installation. The pigtail connections have a gel seal to protect the connection from humidity, water, and dirt.
Pliers (sold separately) are recommended to install wire.
For technical drawings and 3-D models, click on a part number.


Splices | Pliers | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Wire Gauge | For Wire Type | Max. Insulation OD | Color | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Pkg. Qty. | Pkg. | Each | ||
26-22 | Solid | 0.06" | Clear, Yellow | Polycarbonate Plastic | Tin-Plated Copper | 30V AC | 285° | 25 | 0000000 | 000000 | 0000000 | 000000 |
26-19 | Solid | 0.08" | Clear, Yellow | Polypropylene Plastic | Tin-Plated Copper | 30V AC | 285° | 50 | 0000000 | 00000 | 0000000 | 00000 |



Splices | Pliers | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Wire Gauge | For Wire Type | Max. Insulation OD | Color | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Pkg. Qty. | Pkg. | Each | ||
26-19 | Solid | 0.06" | Clear, Red | Polycarbonate Plastic | Tin-Plated Copper | 30V AC | 285° | 25 | 0000000 | 00000 | 0000000 | 000000 |
26-19 | Solid | 0.08" | Clear, Red | Polypropylene Plastic | Tin-Plated Copper | 30V AC | 285° | 100 | 0000000 | 00000 | 0000000 | 00000 |
22-14 | Solid, Stranded | 0.15" | Blue, White | Nylon Plastic | Tin-Plated Brass | 600V AC | 220° | 10 | 0000000 | 00000 | 000000 | 00000 |
Insulation-Piercing Butt Splices



Snap these splices onto your wire and they’ll pierce the insulation without you having to strip it. Pliers (not included) are recommended to install wire. These splices are rated UL 94 V-2, so they meet flammability standards.
For Wire Gauge | For Wire Type | Max. Insulation OD | Color | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Specifications Met | Pkg. Qty. | Pkg. | |
2-Wire Pigtail, 3-Wire Pigtail Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
22-14 | Solid, Stranded | 0.15" | White | Nylon Plastic | Tin-Plated Brass | 600V AC 600V DC | 220° | UL Listed, CSA Certified, UL 94 V-2 | 10 | 0000000 | 00000 |
Submersible Insulation-Piercing Butt Splices


Pierce the insulation of wire without stripping it to make quick connections that are also sealed to keep out water. These splices have termination buttons on each end, so you can make independent connections on both sides. Since you connect each end independently, they’re often used as a disconnect point on equipment that you’ll be moving around. To install these splices, use a pair of pliers to press down on the button until it clicks.
On 2-wire splices, each button comes in one of three colors that correspond with wire gauge, making it easy to match your wire to the right connector.
4-wire splices have two entry points on both ends for twice as many independent connections as 2-wire splices.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | For Wire Type | Max. Insulation OD (For Wire Gauge) | Length | Color | Insulation | Insulation Material | Terminal Material | Maximum Voltage | Maximum Temperature, °F | Environmental Rating | Specifications Met | Each | |
2-Wire Inline Wire Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18-16 | Solid, Stranded | 0.13" (18-16) | 1.89" | Red | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 00000 |
16-14 × 18-16 | Solid, Stranded | 0.13" (16-14), 0.17" (18-16) | 1.89" | Blue and Red | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
14-12 × 18-16 | Solid, Stranded | 0.13" (14-12), 0.17" (18-16) | 1.89" | Yellow and Red | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
14-12 × 16-14 | Solid, Stranded | 0.15" (14-12), 0.17" (16-14) | 1.89" | Yellow and Blue | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
14-12 | Solid, Stranded | 0.17" (14-12) | 1.89" | Yellow | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
4-Wire Inline Wire Connection | |||||||||||||
22-20 | Solid, Stranded | 0.11" (22-20) | 1.43" | Blue | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP05, IP07, IP08 | UL Listed | 0000000 | 0000 |
Insulation-Piercing Wire Taps





Connect a tap wire to a main wire without stripping—these wire taps penetrate insulation. To install, squeeze the tap with standard pliers; a built-in U-shaped metal contact penetrates the insulation and grips the wire.
UL 94 V-2 or V-0 rated taps meet flammability standards.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Stranded | Solid | Color | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Specifications Met | Pkg. Qty. | Pkg. | |
Tap/Main Wire Connection | ||||||||||
22-16 | 22-16 | Red | Polypropylene Plastic | Tin-Plated Brass | 600V AC | 220° | UL Listed, CSA Certified, UL 94 V-2 | 25 | 0000000 | 000000 |
12-10 | 12-10 | Brown | Polypropylene Plastic | Tin-Plated Brass | 600V AC | 220° | UL Listed, CSA Certified, UL 94 V-2 | 25 | 0000000 | 00000 |
2-Wire Pigtail, Inline, Tap/Main Wire Connection | ||||||||||
22-18 | 18 | Red | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 220° | UL Listed, UL 94 V-0 | 50 | 0000000 | 00000 |
18-14 | 16 | Blue | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 220° | UL Listed, UL 94 V-0 | 50 | 0000000 | 00000 |
12-10 | __ | Yellow | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 220° | UL Listed, UL 94 V-0 | 50 | 0000000 | 00000 |
2-Wire Pigtail, Inline, Tap/Main, Double Run Wire Connection | ||||||||||
18-14 | 18-14 | Red | Polypropylene Plastic | Tin-Plated Brass | 32V AC 32V DC | 190° | __ | 25 | 0000000 | 0000 |
18-14 | 18-14 | White | Polypropylene Plastic | Tin-Plated Brass | 32V AC 32V DC | 190° | __ | 25 | 0000000 | 0000 |
12-10 | 12 | Yellow | Polypropylene Plastic | Tin-Plated Brass | 600V AC 600V DC | 190° | UL Listed | 25 | 0000000 | 00000 |
Moisture-Resistant Insulation-Piercing Wire Taps


Filled with gel, these taps seal out moisture. Use them to connect a tap wire to a main wire without stripping—they penetrate insulation. To install, squeeze the tap with standard pliers; a built-in U-shaped metal contact penetrates the insulation and grips the wire.
UL 94 V-2 rated taps meet flammability standards.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded | Solid | For Number of Wires | Max. Insulation OD | Color | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Specifications Met | Pkg. Qty. | Pkg. | |
Tap/Main Wire Connection | ||||||||||||
__ | 26-19 | 2 | 0.08" | Blue and Clear | Polypropylene Plastic | Tin-Plated Copper | 30V AC | 285° | __ | 50 | 0000000 | 000000 |
18-14 | 18-16 | __ | __ | Blue | Polypropylene Plastic | Tin-Plated Brass | 600V AC | 190° | UL Listed, CSA Certified, UL 94 V-2 | 10 | 0000000 | 00000 |
Tap-to-Connector Insulation-Piercing Wire Taps and Plugs


Tap a wire or add a finished terminal to the end of a wire. The parallel taps quickly connect to your wire without stripping the wire first. Squeeze the tap with standard pliers and the U-shaped contact pierces the insulation and grips the wire. Insert a snap plug into the parallel tap. Parallel tap and snap plug are sold separately.
For Wire Gauge | For Wire Type | Color | Gender | Dia. | Insulation | Insulation Material | Terminal Material | Max. Voltage | Max. Temperature, °F | Pkg. Qty. | Pkg. | |
Snap Plug | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
16-14 | Solid, Stranded | Blue | Male | 0.16" | Barrel Insulated | Nylon Plastic | Tin-Plated Copper | Not Rated | 220° | 10 | 000000 | 00000 |
Parallel Tap with Inline Wire Connection | ||||||||||||
18-14 | Solid, Stranded | Black | __ | __ | Fully Insulated | Polypropylene Plastic | Tin-Plated Copper | 32V AC | 190° | 10 | 000000 | 00000 |
Insulation-Piercing Crimp-On Wire Splicing Connectors

No wire stripping is required—these connectors pierce the insulation.
Gel-filled connectors protect your connection from corrosion, humidity, water, and dirt.
Crimper (sold separately) is required for wire installation.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | Min. Wire Combination | Max. Wire Combination | For Wire Type | Insulation Material | Terminal Material | Max. Voltage | Max. Current | Features | Pkg. Qty. | Pkg. | |
24-16 | Four 24-ga. Wires | Three 16-ga. Wires | Solid, Stranded | Polyolefin Plastic | Tin-Plated Bronze | 50V DC | 175 mA | __ | 100 | 000000 | 00000 |
24-16 | Four 24-ga. Wires | Three 16-ga. Wires | Solid, Stranded | Polyolefin Plastic | Tin-Plated Bronze | 50V DC | 175 mA | Gel Filled | 100 | 000000 | 00000 |
Crimper | 000000 | Each | 00000 |
M8 Ethernet Connectors
The threaded end of these M8 connectors keeps contaminants out and withstands vibration better than RJ45 ends on traditional Ethernet cords. They are often used with sensors, switches, and I/O modules. To protect against signal interference, these connectors are shielded. Connectors are Power over Ethernet (POE) enabled to carry data and power within one connector.
To view wiring diagrams, select a part number and click Product Detail.
Snap-on wire connections pierce wire insulation, eliminating the need for wire stripping. They maintain a secure hold in high-vibration applications.
These connectors are IP rated when mated. IP65 rated connectors protect against dust and low-pressure jets of water. IP67 rated connectors keep out dust and water from temporary submersion.
For technical drawings and 3-D models, click on a part number.


Number of Poles | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Shielding | Temperature Range, °F | Environmental Rating | Each | |
D-Coded—Category 5 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.24"-0.26" | Shielded | -40° to 185° | IP65, IP67 | 0000000 | 000000 |


Number of Poles | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Shielding | Temperature Range, °F | Environmental Rating | Each | |
D-Coded—Category 5 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.24"-0.26" | Shielded | -40° to 185° | IP65, IP67 | 0000000 | 000000 |
Micro M12 Screw-Together Ethernet Connectors
Unlike traditional RJ45 connectors found in data centers, these connectors stand up to rugged industrial environments since they tightly thread to devices with M12 connections, sealing out contaminants and resisting shaking loose from vibration. Use them to transfer high-speed data between sensors, switches, computers, IO modules, programmable logic controllers (PLCs), and other equipment. They can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. These connectors are often used with EtherNet/IP, Profinet, and EtherCAT systems. Since they’re shielded, they block signal interference from nearby devices, maintaining their speed and data integrity. Poles and keyways on the face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
When choosing an Ethernet connector, make sure you match or exceed your network’s category industry designation. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
A-coded and X-coded connectors send data faster than D-coded connectors, so they’re best for robotics and other systems that run multi-step programs.
Connectors with a snap-on wire connection pierce the wire’s insulation, which means you don’t need to strip it.
IP rated connectors keep out dust and can be used in wet areas when mated or capped. IP65 connectors can be lightly rinsed. IP67 connectors can be submerged temporarily.
Add caps to protect connectors and maintain their IP ratings when not in use.






Housing Thread | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Shielding | For Wire Gauge | For Cable OD | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
A-Code | |||||||||||||
8 | Shielded | 20 | 0.23"-0.31" | __ | 10 Gb/s | Nickel-Plated Brass | M12 | 1 | -10° to 185° | IP67 | C-UL Recognized Component, UL Recognized Component | 0000000 | 000000 |
D-Code | |||||||||||||
4 | Shielded | 26-22 | 0.18"-0.35" | Category 5 | 100 Mbps | Chrome-Plated Zinc | M12 | 1 | -40° to 185° | IP65, IP67 | __ | 000000 | 00000 |
X-Code | |||||||||||||
8 | Shielded | 26-22 | 0.2"-0.38" | Category 5E, Category 6, Category 6A | 10 Gb/s | Nickel-Plated Zinc | M12 | 1 | -40° to 185° | IP67 | __ | 0000000 | 00000 |

For Thread Size | Material | Includes | Each | |
For Plugs and Receptacles with External Threads | ||||
---|---|---|---|---|
M12 | Anodized Aluminum | Lanyard | 0000000 | 000000 |
Nano M8 Connectors
Also known as pico connectors, these are for low-current devices such as 8 mm and smaller proximity switches and photoelectric switches.
To view wiring diagrams, select a part number and click Product Detail.
Connectors with a snap-on wire connection pierce the insulation to eliminate the need for wire stripping. They maintain a secure hold in high-vibration applications. IP65 rated connectors protect against dust and low-pressure jets of water. IP67 rated connectors protect against dust and temporary submersion. Note: Sockets and female receptacles may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.



Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current, A | For Wire Gauge | For Cable OD | Color | Housing Material | Size | Pitch, mm | Max. Temp., °F | Environmental Rating | Each | |
3 | A | 0.2" | 32V AC/32V DC | 4 | 24-20 | 0.1"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP65, IP67 | 0000000 | 000000 |
4 | A | 0.2" | 32V AC/32V DC | 4 | 24-20 | 0.1"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP65, IP67 | 0000000 | 00000 |



Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current, A | For Wire Gauge | For Cable OD | Color | Housing Material | Size | Pitch, mm | Max. Temp., °F | Environmental Rating | Each | |
3 | A | 0.2" | 32V AC/32V DC | 4 | 24-20 | 0.1"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP65, IP67 | 0000000 | 000000 |
4 | A | 0.2" | 32V AC/32V DC | 3 | 24-20 | 0.14"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP65, IP67 | 0000000 | 00000 |
Latching Washdown RJ45 Connectors
Protect connections in washdown environments while maintaining access—these RJ45 plugs and adapters latch together securely, yet quickly detach. When mated, they’re rated IP65 and IP67 for protection against washdowns and temporary submersion. All are shielded to prevent electromagnetic interference.
Plugs have a snap-on wire connection that pierces the insulation to eliminate the need for wire stripping.

For Cable Industry Designation | Wire Connection Type | Number of Wires | For Cable OD | Housing Material | Color | Environmental Rating | Specifications Met | Each | |
Shielded | |||||||||
---|---|---|---|---|---|---|---|---|---|
Category 5E | Snap On | 8 | 0.26"-0.37" | Powder-Coated Zinc | Gray | IP65, IP67 | DNV-GL Type Approved | 000000 | 000000 |
Unshielded Snap-On Data Connectors

The snap-on wire connection pierces the insulation to eliminate the need for wire stripping. A color-coded wiring guide makes it easier to identify where to insert each wire.
For technical drawings and 3-D models, click on a part number.
Panel-Mount Straight-Blade Receptacles
Snap these receptacles into a cutout on an electrical panel—no screws or clips needed. They have snap-on terminals that pierce wire insulation, eliminating the need for wire stripping during wire installation.
For technical drawings and 3-D models, click on a part number.


For Wire | For Panel | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Wire Connection Type | Type | Gauge | Receptacle Terminal Location | Cutout Ht. | Cutout Wd. | Thick. | Features | Color | Each | |
Grounded | |||||||||||||
5-15 | 125V AC | 15A | Snap On | Solid | 14-12 | Back | 1" | 1" | 0.03"-0.07" | Mounting Tabs | Black | 000000 | 00000 |
Micro M12 Screw-Together Connectors
Because they tightly thread to M12 connections, these connectors won’t let contaminants in or come loose from vibration in rugged industrial environments and automated systems as they send power and signal or just power to your equipment. Their poles and keyways adhere to standard coding layouts, reducing the chance you’ll mismatch connectors.
A- and C-coded connectors send both power and signal, while K-, L-, S-, and T-coded connectors only send power. Choose A-coded connectors for AC and DC sensors, actuators, motors, light curtains, and other devices. They’re often used to connect equipment to IO Link controllers and within Profibus, DeviceNet, and other fieldbus systems. 90° elbow connectors run your cord along the side of equipment, so they fit behind machines and in tight spaces.
Connectors with a snap-on wire connection pierce the wire’s insulation, so you don’t need to strip it.IP67 and IP68 rated connectors can withstand brief submersion. Add caps to protect connectors and maintain their IP and NEMA ratings when not in use.
Note: Sockets and female receptacles may have extra holes on their face that are not used.
For technical drawings and 3-D models, click on a part number.



Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Max. Temp., °F | Environmental Rating | Each | |
4 | A | 0.3" | 32V AC/32V DC | 4A | 24-20 | 0.16"-0.2" | Nylon Plastic | M12 | 1 | Metric | 185° | IP67 | 0000000 | 000000 |
5 | A | 0.3" | 50V AC/50V DC | 4A | 22-20 | 0.19"-0.23" | Nylon Plastic | M12 | 1 | Metric | 185° | IP67 | 0000000 | 00000 |


Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Max. Temp., °F | Environmental Rating | Each | |
4 | A | 0.3" | 32V AC/32V DC | 4A | 24-20 | 0.16"-0.2" | Nylon Plastic | M12 | 1 | Metric | 185° | IP67 | 0000000 | 000000 |



Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Voltage | Current | Face Dia. | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Max. Temp., °F | Environmental Rating | Each | |
4 | A | 32V AC/32V DC | 4A | 0.3" | 24-20 | 0.16"-0.2" | Nylon Plastic | M12 | 1 | Metric | 185° | IP67 | 0000000 | 000000 |
5 | A | 50V AC/50V DC | 4A | 0.3" | 22-20 | 0.19"-0.23" | Nylon Plastic | M12 | 1 | Metric | 185° | IP67 | 0000000 | 00000 |
Shielded Snap-On Data Connectors



Protect equipment from electromagnetic interference. Connectors have a snap-on wire connection that pierces the insulation to eliminate the need for wire stripping. A color-coded wiring guide allows for quick cable termination.
Plugs with a cord grip offer strain relief and keep the cable securely attached in applications that require frequent movement, such as robotics.
Plugs with an adjustable-angle elbow let you choose a 0°-90° bend angle while installing. Good when space is tight around the port, you can rotate them into 32 positions.
Ethernet Connection Type | For Cable Industry Designation | Number of Wires | For Wire Type | For Cable OD | Angle | Housing Material | Color | Specifications Met | Environmental Rating | Features | Each | |
Straight | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
RJ45 | Category 5 | 4 | Solid, Stranded | 0.18"-0.34" | __ | Plastic | Black | UL 94 V-0, DNV-GL Type Approved | IP20 | Color-Coded Wire Guide, Cord Grip | 0000000 | 000000 |
RJ45 | Category 5E | 8 | Solid, Stranded | 0.18"-0.31" | __ | Plastic | Gray | UL Listed, C-UL Listed, DNV-GL Type Approved, LR Type Approved | IP20 | Color-Coded Wire Guide, Cord Grip | 0000000 | 00000 |
RJ45 | Category 6 | 8 | Solid, Stranded | 0.18"-0.34" | __ | Plastic | Black | UL 94 V-0, DNV-GL Type Approved | IP20 | Color-Coded Wire Guide, Cord Grip | 00000000 | 00000 |
RJ45 | Category 6A | 8 | Solid, Stranded | 0.22"-0.41" | __ | Nickel-Plated Zinc | __ | UL Listed, C-UL Listed | IP20 | Color-Coded Wire Guide | 0000000 | 00000 |
RJ45 | Category 8 | 8 | Solid, Stranded | 0.22"-0.41" | __ | Nickel-Plated Zinc | __ | UL Listed, C-UL Listed | IP20 | Color-Coded Wire Guide | 00000000 | 00000 |
Adjustable-Angle Elbow | ||||||||||||
RJ45 | Category 6A | 8 | Solid, Stranded | 0.22"-0.41" | 0°-90° | Nickel-Plated Zinc | __ | UL Listed, C-UL Listed | IP20 | Color-Coded Wire Guide | 0000000 | 00000 |
RJ45 | Category 8 | 8 | Solid, Stranded | 0.22"-0.41" | 0°-90° | Nickel-Plated Zinc | __ | UL Listed, C-UL Listed | IP20 | Color-Coded Wire Guide | 00000000 | 00000 |
Quick-Wire Sure-Grip Straight-Blade Plugs
Eliminate the need for wire stripping; snap-on terminals pierce the wire insulation. Access the wire connection by opening the hinged housing. Also known as hospital-grade plugs, these have an extra-tight fit when mated with sockets or receptacles to remain secure in high-vibration environments. The housing is impact-resistant plastic.
Note: The current rating of your plug should not exceed that of your socket or receptacle.
For technical drawings and 3-D models, click on a part number.



NEMA Style | Voltage | Current | Wire Connection Type | For Cable OD | Features | Environmental Rating | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Snap On | 0.3"-0.36" | Green Dot | IP20 | UL Listed, UL 498, CSA Certified, UL 94 HB, Fed. Spec. W-C-596G | White | 0000000 | 000000 |
Quick-Wire Hinged Straight-Blade Plugs and Sockets
Eliminate the need for wire stripping; snap-on terminals pierce the insulation. Access the wire connection by opening the hinged housing. Housing is impact-resistant plastic.
Note: The current rating of your plug should not exceed that of your socket.
For technical drawings and 3-D models, click on a part number.
Square D Load-Center Circuit Breakers





Series, 1
Tandem Pole

Match these circuit breakers to Square D breaker boxes or panel boards of the same manufacturer series. They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits. Because they are thermal-magnetic, these breakers trip two different ways. They either trip when heat is generated by sustained low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6mA. This minimizes the risk of electric shock to workers and equipment.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Current, A | Voltage | Frequency, Hz | Breakthrough Current | Mounting Location | Wire Connection Type | Wd. | Specifications Met | Each | |
QO Series | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 000000 |
20 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 0000000 | 00000 |
40 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 00000 |
2 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
20 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
60 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 00000 |
70 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 0000000 | 000000 |
3 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
20 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
30 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
40 | 120V AC/240V AC/48V DC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC 5,000 A @ 48 V DC | Breaker Box | Snap On | 2 1/4" | UL 489, UL Listed | 00000000 | 000000 |
QO Series with 6mA Ground Fault Sensitivity | |||||||||
1 Pole—Toggle Style | |||||||||
20 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 000000 |
30 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 3/4" | UL 489, UL Listed | 00000000 | 000000 |
2 Pole—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 000000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1 1/2" | UL 489, UL Listed | 00000000 | 000000 |
Homeline Series | |||||||||
1 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 000000000 | 00000 |
1 Pole with Tandem Circuit—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 00000 |
2 Pole—Toggle Style | |||||||||
15 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
40 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 00000000 | 00000 |
50 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 00000 |
60 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 00000 |
Homeline Series with 6mA Ground Fault Sensitivity | |||||||||
1 Pole—Toggle Style | |||||||||
20 | 120V AC | 50/60 | 10,000 A @ 120 V AC | Breaker Box | Snap On | 1" | UL 489, UL Listed | 00000000 | 000000 |
2 Pole—Toggle Style | |||||||||
20 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 000000 |
30 | 120V AC/240V AC | 50/60 | 10,000 A @ 120 V AC 10,000 A @ 240 V AC | Breaker Box | Snap On | 2" | UL 489, UL Listed | 000000000 | 000000 |
Thumb Light Switches



Install these switches inline on a lamp cord.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Action | Industry Designation | Color | Message (Location) | Message Color | Switching Current @ Voltage | Wire Connection Type | Specifications Met | Each | |
Rotary Actuator Style | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Stays Switched (Maintained) | SPST-NO | Brown | __ | __ | 3 A @ 125 V AC | Snap On | UL Listed, CSA Certified | 00000000 | 00000 |
Rocker Actuator Style | ||||||||||
1 | Stays Switched (Maintained) | SPST-NO | Black | Vertical Line (Top), Circle (Bottom) | White | 6 A @ 120 V AC | Snap On | UL Listed, C-UL Listed | 0000000 | 00000 |
1 | Stays Switched (Maintained) | SPST-NO | White | __ | __ | 6 A @ 120 V AC | Snap On | UL Listed, C-UL Listed | 0000000 | 00000 |