Choosing an Electrical Switch
More
Frame-Mounted Safety Switches

Also known as interlock switches, these ensure the safety of personnel by automatically shutting off power to machinery when an access door opens. Mount the switch to the door frame and mount a key to the door so that the key is inserted into the switch when the door is closed. When the door opens, the key is removed from the switch and the machine shuts down. They’re often used with machine guards for large robots.
All switches require an actuator key, but not all include one—check whether you need to pick out a separate actuator key. For some switch styles, you can also select the mounting orientation of the key. Flexible keys pivot at least 15°, making them easier to align with switches during installation.
Style A-G switches have positive-force, normally closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick.
Style J switches have extra safety controls to prevent you from getting trapped next to running machinery. They actuate with the turn of a portable key. Bring the key when you enter an enclosure to ensure machinery won’t start while you’re inside, even if the door closes behind you. As an added fail-safe, a rear release button lets you cut power from inside of enclosures if needed. These switches have light-up indicators that show when they're properly installed and whether they're actuated.
IP67 rated switches protect against temporary submersion. NEMA 4 rated switches protect against washdowns. NEMA 6 rated switches protect against both temporary submersion and washdowns.
For technical drawings and 3-D models, click on a part number.









Housing | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Ht. | Wd. | Dp. | Trade Size | Thread Size | Thread Type | Key Included | Environmental Rating | Each | |
Wire Lead Connection with Positive-Force Normally Closed Contacts | |||||||||||||||||
A | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | DPST-1NO/1NC | 8 A @ 120 V AC, 4 A @ 24 V DC | 250V AC 24V DC | 3.3" | 1.2" | 1.2" | __ | M16 | Metric | Yes | IP67 | 00000000 | 0000000 |
Screw Terminal Connection with Positive-Force Normally Closed Contacts | |||||||||||||||||
B | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 3" | 1" | 1.1" | 1/2 | __ | NPT | Yes | IP67, NEMA 6 | 00000000 | 000000 |
C | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC, 2 A @ 24 V DC | 250V AC 24V DC | 3.6" | 2.1" | 1.3" | 1/2 | __ | NPT | Yes | IP65, NEMA 4 | 00000000 | 000000 |
C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 3 | 3PST-1NO/2NC | 8 A @ 120 V AC, 4 A @ 24 V DC | 600V AC 250V DC | 3.5" | 2.1" | 1.2" | 1/2 | __ | NPT | Yes | IP67 | 00000000 | 000000 |
C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 4 A @ 230 V AC, 4 A @ 24 V DC | 500V AC 24V DC | 3.5" | 2" | 1.2" | __ | M16 | Metric | Yes | IP67 | 00000000 | 000000 |
D | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 6 A @ 120 V AC, 0.27 A @ 24 V DC | 240V AC 250V DC | 3.8" | 1.2" | 1.2" | 1/2 | __ | NPT | Yes | IP67 | 00000000 | 00000 |
E | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 8 A @ 230 V AC, 5 A @ 24 V DC | 400V AC 24V DC | 4.2" | 2" | 1.6" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
E | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 8 A @ 230 V AC, 5 A @ 24 V DC | 400V AC 24V DC | 4.2" | 2" | 1.6" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | __ | M20 | Metric | No | IP67 | 000000000 | 00000 |
F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | BSPP | No | IP67 | 000000000 | 000000 |
F | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | NPT | No | IP67 | 000000000 | 000000 |
F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | __ | M20 | Metric | No | IP67 | 000000000 | 00000 |
F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | BSPP | No | IP67 | 000000000 | 00000 |
F | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 2 A @ 400 V AC | 400V AC | 4.4" | 1.6" | 1.6" | 1/2 | __ | NPT | No | IP67 | 000000000 | 000000 |
Screw Terminal Connection with Positive-Force Normally Closed Contacts and Rotating Head | |||||||||||||||||
C | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 5 A @ 24 V DC | 400V AC 400V DC | 3.5" | 2" | 1.3" | 1/2 | __ | NPT | Yes | IP65 | 00000000 | 000000 |
D | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 10 A @ 120 V AC, 2.5 A @ 125 V DC | 240V AC 250V DC | 3.8" | 1.2" | 1.2" | __ | M20 | Metric | No | IP67 | 00000000 | 00000 |
G | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 10 A @ 230 V AC, 4 A @ 24 V DC | 250V AC 24V DC | 4.3" | 1.6" | 1.4" | __ | M20 | Metric | No | IP67 | 00000000 | 000000 |
Screw Terminal Connection with Rotating Head | |||||||||||||||||
H | 4 | 2 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 8 | 4PST-2NO/2NC | 2.5 A @ 120 V AC, 1 A @ 125 V DC | 120V AC 125V DC | 7.1" | 1.5" | 1.5" | 1/2 | __ | NPT | No | IP67 | 00000000 | 000000 |
Screw Terminal Connection with Rear Release Button, Portable Key, and LED Status Indicator | |||||||||||||||||
J | 6 | 2 Off (Normally Open) and 4 On (Normally Closed) | Stays Switched (Maintained) | 12 | 6PST-2NO/4NC | 3 A @ 240 V AC, 2.5 A @ 250 V DC | 240V AC 250V DC | 5.2" | 4.6" | 2.2" | __ | M20 | Metric | Yes | IP67 | 000000000 | 000000 |



O'all | |||||||
---|---|---|---|---|---|---|---|
Angle Range | Adjustability | Lg. | Wd. | Mounting Fasteners Included | Each | ||
Straight Keys | |||||||
For Style E | __ | __ | 80 mm | 32 mm | No | 00000000 | 000000 |
For Style F | __ | __ | 53.7 mm | 52.4 mm | No | 000000000 | 00000 |
For Style G | __ | __ | 86 mm | 32 mm | No | 00000000 | 00000 |
For Style H | __ | __ | 48.5 mm | 35 mm | No | 00000000 | 00000 |
For Style J | __ | __ | 61.5 mm | 40 mm | No | 000000000 | 00000 |
90° Angle Keys | |||||||
For Style E | __ | __ | 65.5 mm | 32 mm | No | 00000000 | 00000 |
For Style J | __ | __ | 45 mm | 40 mm | No | 000000000 | 00000 |
Flexible Keys | |||||||
For Style D | 0°-15° | Up/Down/Left/Right | 48.9 mm | 55 mm | No | 000000000 | 00000 |
For Style F | 0°-18° | Left/Right | 80.7 mm | 40 mm | No | 000000000 | 00000 |
For Style G | 0°-15° | Up/Down/Left/Right | 105 mm | 40 mm | No | 00000000 | 000000 |
For Style H | 0°-15° | Up/Down/Left/Right | 50.4 mm | 55 mm | No | 00000000 | 00000 |
For Style J | 0°-18° | Left/Right | 70 mm | 40 mm | No | 000000000 | 00000 |
Access-Delay Frame-Mounted Safety Switches




Delay access to hazardous areas until conditions are safe; use these switches with machines that take time to stop after they are turned off. Mount the switch to the door frame and mount the key to the door so that the key is inserted into the switch when the door is closed. When the door is pulled, the key is held in place with 225 lbs. of force until the switch receives a signal from a time-delay relay, motion sensor, or position sensor (not included) that the machine’s motion has stopped. After the motion has stopped, the key can be removed from the switch, releasing the access door. They’re often used with machine guards. All have positive-force, normally-closed contacts that will open a circuit when the switch is actuated even if a spring fails or the contacts stick. They’re rated for protection from washdowns and temporary submersion.
Style A and B have a key entry on the top and side of the switch.
Style C has a key entry on two opposite sides of the switch.
Emergency override keys (sold separately) bypass the access delay feature.
For technical drawings and 3-D models, click on a part number.
Housing | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Input Voltage | Holding Force, lbs. | Ht. | Wd. | Dp. | Wire Connection Type | Conduit Trade Size | Each | |
Positive-Force Normally Closed Contacts | ||||||||||||||||
A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 24V AC, 24V DC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 0000000 |
A | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | 3PST-1NO/2NC | 5 A @ 120 V AC, 2 A @ 24 V DC | 500V AC 250V DC | 110V AC | 225 | 4.7" | 2.3" | 1.4" | Screw Terminals | 1/2 | 0000000 | 000000 |
B | 3 | 1 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 14 | 3PST-1NO/2NC | 3 A @ 120 V AC, 2.5 A @ 24 V DC | 250V DC 240V AC | 24V DC | 225 | 3.7" | 3.5" | 1.4" | Screw Terminals | 1/2 | 0000000 | 000000 |
Positive-Force Normally Closed Contacts and Rotating Head | ||||||||||||||||
C | 4 | 2 Off (Normally Open) and 2 On (Normally Closed) | Stays Switched (Maintained) | 8 | 4PST-2NO/2NC | 4 A @ 120 V AC, 4 A @ 24 V DC | 240V AC 24V DC | 24V AC, 24V DC | 225 | 7.6" | 1.2" | 1.6" | Screw Terminals | 1/2 | 0000000 | 000000 |
Emergency Override Key for Style A | 0000000 | Each | 000000 |
22 mm Panel-Mount Build-Your-Own Metal Switches
Choose an actuator and contact block to make your own switch. All switches are IP and NEMA rated for protection from dust, washdown, and chemicals. For an easy way to tell switches apart without labels, choose them based on their actuator color.
Key actuators prevent accidental activation because they require a key to turn on and off. They are keyed alike, so they will all open with the same key.
For technical drawings and 3-D models, click on a part number.

Switch Action | Dia. | For Max. No. of Contact Blocks | Key Removal Position | Environmental Rating | Specifications Met | Actuator Color | Each | |
2 Positions | ||||||||
---|---|---|---|---|---|---|---|---|
Springs Back (Momentary) | 1 3/16" | 6 | Right | NEMA 4, NEMA 13, IP66 | UL Recognized Component, CSA Certified, CE Marked, CCC Marked, UL 508 | Black | 0000000 | 000000 |
Stays Switched (Maintained) | 1 3/16" | 6 | Left | NEMA 4, NEMA 13, IP66 | UL Recognized Component, CSA Certified, CE Marked, CCC Marked, UL 508 | Black | 0000000 | 00000 |
3 Positions | ||||||||
Springs Back (Momentary), Stays Switched (Maintained) | 1 3/16" | 6 | Left | NEMA 4, NEMA 13, IP66 | UL Recognized Component, CSA Certified, CE Marked, CCC Marked, UL 508 | Black | 0000000 | 00000 |
Stays Switched (Maintained) | 1 3/16" | 6 | Left | NEMA 4, NEMA 13, IP66 | UL Recognized Component, CSA Certified, CE Marked, CCC Marked, UL 508 | Black | 0000000 | 00000 |
Replacement Keys | 00000000 | Pkg. | 000000 |
For Actuator Style | No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Environmental Rating | Specifications Met | Each | |
Push Button, Lever, Key | 1 | 1 On (Normally Closed) | 2 | SPST-NC | IP20 | UL Listed, UL Recognized Component, CSA Certified, CE Marked, CCC Marked, UL 508 | 00000000 | 000000 |
Lever, Key | 1 | 1 Off (Normally Open) | 2 | SPST-NO | IP20 | UL Listed, UL Recognized Component, CSA Certified, CE Marked, CCC Marked, UL 508 | 00000000 | 00000 |
30 mm Panel-Mount Build-Your-Own Metal Switches
Choose an actuator and contact block to make your own switch. All switches are rated for protection from washdowns and oil/coolant spraying. NEMA 4X rated switches are also protected from corrosion. Use legend plates (not included) to label switches.
Key actuators are keyed alike, so they will all open with the same key.
Switch guards protect flush and projecting switches from accidental activation.
For technical drawings and 3-D models, click on a part number.

Switch Action | Switching Current @ Voltage | Max. Voltage | Dia. | For Max. No. of Contact Blocks | No. of Keys Included | Key Removal Position | Key Number | Environmental Rating | Each | |
2 Position | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Springs Back (Momentary) | 6 A @ 120 V AC, 5 A @ 24 V DC | 600V AC/600V DC | 1 1/8" | 4 | 2 | Left | 501CH | NEMA 4, NEMA 13 | 00000000 | 0000000 |
Stays Switched (Maintained) | 6 A @ 120 V AC, 5 A @ 24 V DC | 600V AC/600V DC | 1 1/8" | 4 | 2 | Left, Right | 501CH | NEMA 4, NEMA 13 | 00000000 | 000000 |
3 Position | ||||||||||
Springs Back (Momentary) | 6 A @ 120 V AC, 5 A @ 24 V DC | 600V AC/600V DC | 1 1/8" | 4 | 2 | Center | 501CH | NEMA 4, NEMA 13 | 00000000 | 000000 |
Stays Switched (Maintained) | 6 A @ 120 V AC, 5 A @ 24 V DC | 600V AC/600V DC | 1 1/8" | 4 | 2 | Center, Left, Right | 501CH | NEMA 4, NEMA 13 | 00000000 | 000000 |
Replacement Key | 00000000 | Each | 00000 |
22 mm Panel-Mount Key Switches
Limit access to sensitive equipment—these switches require a key to actuate. They're rated IP66, IP69K, NEMA 3S, NEMA 4X, and NEMA 13, and are UL and C-UL Recognized Components. Switches include enough contact blocks to control the number of circuits listed. Contact blocks are rated IP20 and are UL and C-UL Listed. Use BACO legend plates (not included) to label switches.
Mounting tools (sold separately) make it easier to install switches in crowded panels.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | No. of Keys Included | Key Removal Position | Manufacturer | Each | |
2 Position with Plastic Base | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | |||||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | Black | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 3/16" | 1 11/16" | 6 | 2 | Left | BACO Controls | 000000 | 000000 |
Vibration-Resistant 22 mm Panel-Mount Key Switches

To prevent accidental actuation and limit access to sensitive equipment, these switches require a key to turn circuits on or off. The contact block and actuator are all one piece, so they won’t separate in high-vibration applications. Install them in a standard panel cutout. They’re keyed alike, so they will all open with the same key.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of Keys Included | Key Removal Position | Each | |
2 Position with Plastic Base | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | Black | 0.6 A @ 120 V AC, 0.22 A @125 V DC | 240V AC 250V DC | 1 1/8" | 1 11/16" | 2 | Left | 0000000 | 000000 |
3 Position with Plastic Base | |||||||||||||
With Screw Terminals | |||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | Black | 0.6 A @ 120 V AC, 0.22 A @125 V DC | 240V AC 250V DC | 1 1/8" | 1 11/16" | 2 | Center | 0000000 | 00000 |
30 mm Panel-Mount Key Switches
These switches require a key to turn circuits on or off, limiting access to sensitive equipment. Rated NEMA 6, 13, and IP66, they're protected from washdowns and oil/coolant spraying. All are keyed alike, so they open with the same key. They include enough contact blocks to control the number of circuits listed.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | No. of Keys Included | Key Removal Position | Each | |
2 Position with Metal Base | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 5/16" | 1 5/8" | 4 | 2 | Left | 0000000 | 0000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 5/16" | 1 5/8" | 4 | 2 | Left | 0000000 | 000000 |
Replacement Key | 00000000 | Each | 000000 |
No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Environmental Rating | Specifications Met | Each | |
1 | 1 Off (Normally Open) | 2 | SPST-NO | IP20 | CSA Certified, EN 60947-1, EN 60947-5-1, EN 60947-5-4, IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4 | 0000000 | 000000 |
1 | 1 On (Normally Closed) | 2 | SPST-NC | IP20 | CSA Certified, EN 60947-1, EN 60947-5-1, EN 60947-5-4, IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4 | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 4 | DPST-1NO/1NC | IP20 | CSA Certified, EN 60947-1, EN 60947-5-1, EN 60947-5-4, IEC 60947-1, IEC 60947-5-1, IEC 60947-5-4 | 0000000 | 00000 |
Hazardous Location 30 mm Panel-Mount Key Switches
Designed for use near ignitable gases, fibers, and dust, these switches have a housing that seals in anything that could ignite flammable material. You’ll know they’re safe because they’re NEC Class 1, Division 2 Groups A-D and NEC Zone 1 Groups IIC-IIA certified for hazardous locations. These switches require a key to turn circuits on or off, preventing accidental actuation and limiting access to sensitive equipment. Since they’re keyed alike, all open with the same key. Install them in a standard panel cutout.
Switches that control two circuits come with a contact block for each circuit.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Key Removal Position | Each | |
2 Position with Plastic Base | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Screw Terminals | ||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left | 0000000 | 0000000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Right | 0000000 | 000000 |
3 Position with Plastic Base | ||||||||||||
Screw Terminals | ||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 6 A @ 120 V AC, 4 A @ 24 V DC | 500V AC/500V DC | 1 9/16" | 2 5/8" | 3 | Left, Center, Right | 0000000 | 000000 |

Key Number | Each | |
HW9Z-SKP | 0000000 | 000000 |
16 mm Panel-Mount Key Switches

Limit access to sensitive equipment—these switches require a key to actuate. Rated NEMA 4, 13, and IP65, they're protected from washdowns and oil/coolant spraying. All are keyed alike, so they open with the same key.
Mounting wrenches (sold separately) make it easier to install switches in crowded panels.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Quick-Disconnect Tab Wd. | No. of Keys Included | Key Removal Position | Each | |
2 Position with Plastic Base | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Quick-Disconnect Terminals | |||||||||||||||
1 | 1 Off (Normally Open) | Springs Back (Momentary) | 4 | SPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 3 | 0.11" | 2 | Center | 00000000 | 000000 |
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 4 | SPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 3 | 0.11" | 2 | Center, Right | 00000000 | 00000 |
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 6 | DPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 3 | 0.11" | 2 | Center, Right | 00000000 | 00000 |
3 Position with Plastic Base | |||||||||||||||
With Quick-Disconnect Terminals | |||||||||||||||
2 | 2 Off (Normally Open) | Springs Back (Momentary) | 6 | DPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 2 | 0.11" | 2 | Center | 00000000 | 00000 |
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 6 | DPST-NO | Black | 2.5 A @ 125 V AC, 6 A @ 24 V DC | 250V DC 250V AC | 11/16" | 1 11/16" | 2 | 0.11" | 2 | Left, Center, Right | 00000000 | 00000 |
Washdown 3/4" Panel-Mount Key Switches

Rated NEMA 4 or IP66, these switches are protected from washdowns. They require a key to turn circuits on or off, limiting access to sensitive equipment. All fit into a standard panel cutout.
Keyed alike switches all open with the same key.
For technical drawings and 3-D models, click on a part number.
Key Switches | Replacement Keys | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | No. of Keys Included | Key Removal Position | Environmental Rating | Each | Each | ||
2 Position with Metal Base | |||||||||||||||
Keyed Alike with Screw Terminals | |||||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 20 A @ 240 V AC | 690V AC | 7/8" | 2 5/8" | 2 | Center, Right | IP66 | 00000000 | 000000 | 000000 | 00000 |
Battery Disconnect Switches
Stop battery drain and prevent the theft or unauthorized use of equipment by disconnecting batteries when not in use.
Knob, key, and T-handle actuators can be removed to limit access to the switch.
Use remote-mount switches to cut power to your battery from a distance. Run a battery cable from the battery to the switch.

Max. Continuous Current | Key Removal Position | Material | Ht. | Dia. | No. of Mount. Holes | Mount. Hole Dia. | Includes | Each | |
100 A @ 12 V DC | Off | Brass/Copper | 2 1/2" | 2 1/4" | 2 | 0.19" | Two Keys | 0000000 | 000000 |