About Selecting Temperature Sensors
More
RTD Probes for Liquids and Gases
Obtain more precise and reliable liquid and gas temperature measurements than thermocouple probes. Some of these probes meet DIN standards for accuracy, meaning they’re precise even with fast temperature changes.
IP68- and IP69K-rated probes have plug connections that can handle brief submersion and harsh washdowns.
For technical drawings and 3-D models, click on a part number.
Probes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Cables | ||||||||||
RTD Type | Temperature Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Environmental Rating | Specifications Met | Each | Each | ||
4-Pin Micro M12 Plug Connection—316L Stainless Steel Probe | |||||||||||
100 ohms | -40° to 300° | 2" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 0000000 | 0000000 | 000000 |
100 ohms | -40° to 300° | 2 3/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 3 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 5 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 6 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 7 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 9 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 10 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 13 3/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 14 1/8" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 22" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 6 1/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 6 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 10 1/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 10 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 14 1/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 14 1/8" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 22" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
Threaded RTD Probe Transmitters for Liquids and Gases
Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in transmitter, these RTDs don’t require a separate signal converter. They’re threaded, so they’re ready to install into containers, tanks, and pipes. These RTDs are made of 316 or 316L stainless steel, so they’re highly corrosion resistant. All are CE Marked as meeting European safety standards.
RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. They’re also UL listed and C-UL listed for American and Canadian safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | Probe Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Lg. | Dia. | Accuracy | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Choose a Temperature Range | Each | |
316 Stainless Steel Probe with Plastic Head (IP65) | |||||||||||||
100 ohms | 2 1/2" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 5 3/4" | 000000 | 0000000 | |
100 ohms | 4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 7 1/4" | 000000 | 000000 | |
100 ohms | 6" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 9 1/4" | 000000 | 000000 | |
100 ohms | 9" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 12 1/4" | 000000 | 000000 | |
100 ohms | 12" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 15 1/4" | 0000000 | 000000 |
Probe | Probe Connection | Probe Transmitters | Cables with Socket | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Communication Protocol | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe (IP67, IP68, IP69K) | |||||||||||||||||
1,000 ohms | 0° to 300° | 1 3/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 5,800 | 4-20mA | IO Link | 4 1/8" | 0000000 | 0000000 | 0000000 | 000000 |
1,000 ohms | 0° to 300° | 2" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 5" | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 0° to 300° | 3 15/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 7" | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 0° to 300° | 5 15/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 8 7/8" | 0000000 | 000000 | 0000000 | 00000 |
Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gases
Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're made of stainless steel, so they won't corrode from harsh cleaners and sanitizers. The housing is IP69K rated, meaning it withstands high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. They have a flange that will connect to sanitary quick-clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
Program these probes with the touch screen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet DIN EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | Probe Transmitters | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Plug Type | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe with 304 Stainless Steel Head (IP69K) | |||||||||||||||
For 1 1/2" Tube OD | |||||||||||||||
100 ohms | -55° to 480° | 2" | 5/16" | 1.988" | ±0.1% | 25 | 5-Pole Micro M12 | 8-35 | 580 | 4-20mA | 6 3/4" | 0000000 | 0000000 | 0000000 | 000000 |
Thermocouple and RTD Connection Heads
Attach these heads to your thermocouple or RTD probe to protect wiring from dust and moisture. The removable cap makes it easy to access your wiring when you need. Install an optional terminal block inside the head to keep your wiring organized.
Hazardous location connection heads are rated for use in Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 environments with flammable gases, combustible dust, and combustible fibers.
Probe Connection | Conduit Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Includes | Environment | Environmental Rating | Each | |
Aluminum | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | Hazardous Location | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 4X | 00000000 | 0000000 |
Stainless Steel | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | Hazardous Location | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 | 00000000 | 000000 |