About Selecting Temperature Sensors
More
RTD Probes for Liquids and Gases
Obtain more precise and reliable liquid and gas temperature measurements than thermocouple probes. Some of these probes meet DIN standards for accuracy, meaning they’re precise even with fast temperature changes.
IP67-rated probes have plug connections that stand up to dust and temporary submersion. IP68- and IP69K-rated probes have plug connections that can handle brief submersion and harsh washdowns.
For technical drawings and 3-D models, click on a part number.
Probes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Cables | ||||||||||
RTD Type | Temperature Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Environmental Rating | Specifications Met | Each | Each | ||
4-Pin Micro M12 Plug Connection—316L Stainless Steel Probe | |||||||||||
100 ohms | -40° to 300° | 2" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 0000000 | 0000000 | 000000 |
100 ohms | -40° to 300° | 2 3/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 3 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 5 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 6 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 7 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 9 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 10 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 13 3/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 14 1/8" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 22" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 6 1/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 6 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 10 1/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 10 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 14 1/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 14 1/8" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 22" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Length | Max. Cable Temperature, °F | Environmental Rating | Specifications Met | Each | |
4-Pin Micro M12 Plug Connection—316 Stainless Steel Probe | |||||||||||
100 ohms | -145° to 1110° | 3 7/8" | 1/4" | ±0.1% | 34 | 6.5 ft. | 480° | IP67 | DIN EN 60751 Class A | 0000000 | 0000000 |
100 ohms | -145° to 1110° | 5 7/8" | 1/4" | ±0.1% | 34 | 6.5 ft. | 480° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
100 ohms | -145° to 1110° | 7 7/8" | 1/4" | ±0.1% | 34 | 6.5 ft. | 480° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
100 ohms | -145° to 1110° | 7 7/8" | 1/4" | ±0.1% | 34 | 32 ft. | 480° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
100 ohms | -145° to 1110° | 9 7/8" | 1/4" | ±0.1% | 34 | 6.5 ft. | 480° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
1,000 ohms | -55° to 480° | 2" | 1/4" | ±0.1% | 37 | 0.5 ft. | 480° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
4-Pin Micro M12 Plug Connection—316L Stainless Steel Probe | |||||||||||
100 ohms | -55° to 480° | 1 5/8" | 3/8" | ±0.1% | 39 | 6.5 ft. | 480° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
100 ohms | -40° to 190° | 1 3/4" | 1/4" | ±0.1% | 10 | 6.5 ft. | 190° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
100 ohms | -40° to 190° | 1 3/4" | 1/4" | ±0.1% | 10 | 16 ft. | 190° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
100 ohms | -40° to 190° | 2" | 3/8" | ±0.1% | 25 | 6.5 ft. | 190° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
100 ohms | -40° to 190° | 2" | 3/8" | ±0.1% | 25 | 16 ft. | 190° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
1,000 ohms | -40° to 190° | 1 3/4" | 1/4" | ±0.1% | 10 | 6.5 ft. | 190° | IP67 | DIN EN 60751 Class A | 0000000 | 00000 |
1,000 ohms | -40° to 190° | 2" | 3/8" | ±0.1% | 25 | 6.5 ft. | 190° | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
Bolt-On RTD Probes for Surfaces
For reliable temperature readings in high-vibration environments, these RTD probes bolt onto the surface of motors and other equipment.
Style A and B probes are rated IP67 for protection from dust and temporary submersion.
Probes that meet DIN EN 60751 adhere to industry standards for accuracy.
Probe | Cable | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | RTD Type | Temp. Range, °F | Bolt Hole Dia. | Lg. | Wd. | Thick. | Accuracy | Response Time, sec. | Lg., ft. | Material | Environmental Rating | Specifications Met | Each | |
Stainless Steel Probe | ||||||||||||||
A | 100 ohms | -40° to 190° | 1/2" | 2" | 7/16" | 5/16" | ±0.5% | 15 | 6 | Polyurethane Rubber | IP67 | DIN EN 60751 Class A | 0000000 | 0000000 |
Probe | Cable | Wire Lead | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | RTD Type | Temp. Range, °F | Bolt Hole Dia. | Lg. | Wd. | Thick. | Accuracy | Response Time, sec. | Lg., ft. | Material | Lg. | Gauge | No. of Wires | Environmental Rating | Specifications Met | Each | |
Stainless Steel Probe | |||||||||||||||||
B | 100 ohms | -40° to 190° | 1/4" | 1 13/16" | 7/16" | 5/16" | ±0.5% | 39 | 6 | Polyurethane Rubber | 1" | 22 | 4 | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
Adhesive-Back RTD Probes for Surfaces
About the thickness of a dime, these RTD probes stick to surfaces in tight spaces to measure temperature.
Probes that meet DIN EN 60751 adhere to industry standards for accuracy. Probes that meet MIL-STD-108 are submersible, so they can monitor the temperature of water in tanks or containers.
Probe | Cable | Wire Lead | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Lg. | Wd. | Thick. | Accuracy | Response Time, sec. | Lg., ft. | Material | Lg. | Gauge | No. of Wires | Specifications Met | Each | |
Wire Leads Connection—Platinum Probe | ||||||||||||||
100 ohms | -4° to 300° | 9/16" | 3/16" | 1/16" | ±0.12% | 1.3 | 3 | Silicone Rubber | 1/2" | 28 | 3 | DIN EN 60751 Class B; MIL-STD-108 | 0000000 | 0000000 |
1,000 ohms | -4° to 300° | 9/16" | 3/16" | 1/16" | ±0.12% | 1.3 | 3 | Silicone Rubber | 1/2" | 28 | 3 | MIL-STD-108 | 0000000 | 000000 |
Threaded RTD Probes for Surfaces
Thread these RTD probes into threaded holes in molds, dies, and other objects to measure their temperature.
Style A and B probes are rated IP67 for protection from dust and temporary submersion.
Probes that meet DIN EN 60751 adhere to industry standards for accuracy.
Thread | Probe | Cable | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Size | Pitch, mm | Lg. | Wd. | Thick. | Accuracy | Response Time, sec. | Lg., ft. | Material | Environmental Rating | Specifications Met | Each | ||
Stainless Steel Probe | |||||||||||||||
A | 100 ohms | -20° to 350° | M5 | 0.8 | 15/16" | 5/16" | 3/16" | ±0.5% | 8 | 6 | Silicone Rubber | IP67 | DIN EN 60751 Class A | 0000000 | 0000000 |
A | 100 ohms | -20° to 350° | M6 | 1 | 15/16" | 5/16" | 3/16" | ±0.5% | 8 | 6 | Silicone Rubber | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
A | 100 ohms | -40° to 190° | M5 | 0.8 | 15/16" | 5/16" | 3/16" | ±0.5% | 8 | 6 | Polyurethane Rubber | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
A | 100 ohms | -40° to 190° | M6 | 1 | 15/16" | 5/16" | 3/16" | ±0.5% | 9 | 6 | Polyurethane Rubber | IP67 | DIN EN 60751 Class A | 0000000 | 000000 |
Thread | Probe | Cable | Wire Lead | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Size | Pitch, mm | Lg. | Wd. | Thick. | Accuracy | Response Time, sec. | Lg., ft. | Material | Lg. | Gauge | No. of Wires | Environmental Rating | Specifications Met | Each | ||
Stainless Steel Probe | ||||||||||||||||||
B | 100 ohms | -20° to 300° | M12 | 1.5 | 1 3/16" | 3/8" | 11/16" | ±0.5% | 12 | 16 | Silicone Rubber | 1" | 22 | 4 | IP67 | DIN EN 60751 Class A | 0000000 | 0000000 |
Threaded RTD Probe Transmitters for Liquids and Gases
Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in transmitter, these RTDs don’t require a separate signal converter. They’re threaded, so they’re ready to install into containers, tanks, and pipes. These RTDs are made of 316 or 316L stainless steel, so they’re highly corrosion resistant. All are CE Marked as meeting European safety standards.
RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. They’re also UL listed and C-UL listed for American and Canadian safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | Probe Connection | Probe Transmitters | Cables with Socket | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Communication Protocol | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe (IP67, IP68, IP69K) | |||||||||||||||||
1,000 ohms | 0° to 300° | 1 3/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 5,800 | 4-20mA | IO Link | 4 1/8" | 0000000 | 0000000 | 0000000 | 000000 |
1,000 ohms | 0° to 300° | 2" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 5" | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 0° to 300° | 3 15/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 7" | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 0° to 300° | 5 15/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 8 7/8" | 0000000 | 000000 | 0000000 | 00000 |
Threaded RTD Probe Transmitters with Digital Display for Liquids and Gases
View temperature readings and adjust settings directly on these RTD probe transmitters. To communicate with programmable logic controllers (PLCs), they have a built-in transmitter with two outputs. One output can send a digital switching signal or use IO Link protocol with the addition of an IO Link controller (not included). The other can send a digital switching signal or a 4-20mA analog signal. The different output options make these RTDs good for a wide range of uses, including operating far away from a controller, taking automated measurements, and providing inputs to switching applications. All have an NPT threaded fitting welded onto the probe, so they’re ready to screw into containers, tanks, and pipes. Probe length is fixed. Made of 316L stainless steel, they are highly corrosion resistant.
These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. UL Listed, C-UL Listed, and CE Marked, all meet American, Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | Configurable Digital Output | Configurable Analog/Digital Output | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Plug Type | Probe Connection Pipe Size | Max. Pressure, psi | No. of | Communication Protocol | Signal Type | No. of | Current | Signal Type | Overall Lg. | Each | |
NPT Male Probe Connection | |||||||||||||||||
316L Stainless Steel Probe with Plastic Head (IP67) | |||||||||||||||||
1,000 ohms | -55° to 300° | 1/2" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/4 | 5,800 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 4 7/8" | 0000000 | 0000000 |
1,000 ohms | -55° to 300° | 1/2" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 4,350 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 4 7/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 1 1/4" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/4 | 5,800 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 5 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 1 1/4" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 4,350 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 5 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 3 1/4" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 3,625 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 7 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 5 3/16" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 3,625 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 9 1/2" | 0000000 | 000000 |
Cable Lead Lg., ft. | Voltage | Current | Face Diameter | Each | |
12 | 250V AC/250V DC | 4A | 0.3" | 0000000 | 000000 |
RTD Transmitters
Convert signals from your RTD probe into signal types that data loggers, controllers, and other instruments can read.
Thread-in transmitters automatically recognize the probe type, so you don’t need to program them to match. They communicate via IO Link, which lets you change settings, read measurements, and receive error messages remotely when connected to a PLC via an IO Link controller (not included).
For technical drawings and 3-D models, click on a part number.
For RTD Probe Type | Temperature Range, °F | Dia. | Dp. | DC Voltage | Output Current | Output Voltage | Communication Protocol | Housing Material | Environmental Rating | Each | |
4-Pole Micro M12 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
100 ohms/1,000 ohms | -55° to 300° | 3/4" | 2" | 20-32 | 4-20mA | __ | IO Link | Plastic | IP67 | 00000000 | 0000000 |
100 ohms/1,000 ohms | 32° to 212° | 3/4" | 2" | 20-32 | 4-20mA | __ | IO Link | Plastic | IP67 | 00000000 | 000000 |
100 ohms/1,000 ohms | 32° to 212° | 3/4" | 2" | 18-32 | __ | 0-10V DC | IO Link | Plastic | IP67 | 00000000 | 000000 |