About Selecting Temperature Sensors
More
RTD Probes for Liquids and Gases
Obtain more precise and reliable liquid and gas temperature measurements than thermocouple probes. Some of these probes meet DIN standards for accuracy, meaning they’re precise even with fast temperature changes.
IP68- and IP69K-rated probes have plug connections that can handle brief submersion and harsh washdowns.
For technical drawings and 3-D models, click on a part number.


Probes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Cables | ||||||||||
RTD Type | Temperature Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Environmental Rating | Specifications Met | Each | Each | ||
4-Pin Micro M12 Plug Connection—316L Stainless Steel Probe | |||||||||||
100 ohms | -40° to 300° | 2" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 0000000 | 0000000 | 000000 |
100 ohms | -40° to 300° | 2 3/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 3 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 5 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 6 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 7 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 9 7/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 10 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 13 3/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 14 1/8" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
100 ohms | -40° to 300° | 22" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 6 1/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 6 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 10 1/4" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 10 1/4" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 14 1/8" | 1/4" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 14 1/8" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | -40° to 300° | 22" | 3/8" | ±0.1% | 3 | IP68, IP69K | DIN EN 60751 Class A | 0000000 | 000000 | 0000000 | 00000 |
Threaded RTD Probe Transmitters for Liquids and Gases
Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in 4-20mA transmitter, these RTDs don’t require a separate signal converter. They have an NPT male probe connection, so they’re ready to screw into thermowells and other fittings on pipe and tanks. Made of 316 or 316L stainless steel, they resist corroding from harsh cleaning chemicals. This stainless steel also protects the RTD sensor inside from impact. They are also often installed in bores to measure the temperature of molds and dies. CE marked, they meet European safety standards.
Fixed RTDs can be used directly in liquid or steam because they’re welded to their fitting for a liquid-tight seal.
RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. UL and C-UL listed, they meet American and Canadian safety standards.
For technical drawings and 3-D models, click on a part number.

Probe Transmitters | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Probe Connection | Cables with Socket | ||||||||||||||||
RTD Type | Lg. | Dia. | Accuracy | Response Time, sec. | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Communication Protocol | Overall Lg. | Fitting Material | Temp. Range, °F | Each | Each | ||
Fixed 316L Stainless Steel Probe (IP67, IP68, IP69K) | ||||||||||||||||||
1,000 ohms | 11/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 5,800 | 4-20mA | IO Link | 4 1/8" | 316L Stainless Steel | 0° to 300° | 0000000 | 0000000 | 0000000 | 000000 |
1,000 ohms | 1 1/2" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 5" | 316L Stainless Steel | 0° to 300° | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 3 1/2" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 7" | 316L Stainless Steel | 0° to 300° | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 5 7/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 8 7/8" | 316L Stainless Steel | 0° to 300° | 0000000 | 000000 | 0000000 | 00000 |
Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gases
Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're made of stainless steel, so they won't corrode from harsh cleaners and sanitizers. The housing is IP69K rated, meaning it withstands high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. They have a flange that will connect to sanitary quick-clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
Program these probes with the touch screen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet DIN EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
For technical drawings and 3-D models, click on a part number.


Probe | Probe Transmitters | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Plug Type | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe with 304 Stainless Steel Head (IP69K) | |||||||||||||||
For 1 1/2" Tube OD | |||||||||||||||
100 ohms | -55° to 480° | 2" | 5/16" | 1.988" | ±0.1% | 25 | 5-Pole Micro M12 | 8-35 | 580 | 4-20mA | 6 3/4" | 0000000 | 0000000 | 0000000 | 000000 |