Probe | Conduit Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Overall Lg. | Each | |
316 Stainless Steel Probe with Plastic Head | |||||||||||||
For 1 1/2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 1.984" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 0000000 |
For 2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 2.516" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 000000 |
Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gases
Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're made of stainless steel, so they won't corrode from harsh cleaners and sanitizers. The housing is IP69K rated, meaning it withstands high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. They have a flange that will connect to sanitary quick-clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
Program these probes with the touch screen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet DIN EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | Probe Transmitters | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Plug Type | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe with 304 Stainless Steel Head (IP69K) | |||||||||||||||
For 1 1/2" Tube OD | |||||||||||||||
100 ohms | -55° to 480° | 2" | 5/16" | 1.988" | ±0.1% | 25 | 5-Pole Micro M12 | 8-35 | 580 | 4-20mA | 6 3/4" | 0000000 | 0000000 | 0000000 | 000000 |