About Selecting Temperature Sensors
More
RTD Probes with Armored Cable for Liquids and Gases


For long service life in harsh conditions, these RTD probes have an armored stainless steel cable to protect wiring from corrosion, abrasion, and impact. Stainless steel also encases the probes, keeping them safe if they get hit and from liquids when they’re immersed. They are often installed in a bore to measure the temperature of molds, dies, and other equipment.
Probes with strain relief offer extra support for moving cables. They also help avoid kinking for longer cable life.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Cable Material | Max. Cable Temperature, °F | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
Probe | ||||||||||||||
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 3.5 | 6 | Wire Leads | Stainless Steel Armor | 400° | 2" | 24 | 3 | 0000000 | 0000000 |
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 10 | 3 | Wire Leads | Stainless Steel Armor | 400° | 2" | 24 | 3 | 0000000 | 000000 |
100 ohms | -55° to 400° | 12" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Stainless Steel Armor | 400° | 2" | 24 | 3 | 0000000 | 000000 |
Probe with Strain Relief | ||||||||||||||
100 ohms | -55° to 400° | 3" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 2" | 24 | 3 | 0000000 | 00000 |
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 2" | 24 | 3 | 0000000 | 00000 |
100 ohms | -55° to 400° | 12" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 2" | 24 | 3 | 0000000 | 00000 |
Threaded RTD Probes with Thermowell for Liquids and Gases


To protect against vibration and shock during temperature measurements, these RTD probes come with a thermowell. Made of stainless steel, it acts as a shield for added protection from corrosion in liquids and gases. The thermowell also lets you replace the probe sensor without stopping flow or draining your system. For accurate readings, a spring pushes the probe tip forward, keeping the tip in constant contact with the thermowell. Rated IP65 and NEMA 4, these probes seal out dust and water from washdowns. Remove the cap on the head to wire the probe’s terminal block to your application.
Probe | Thermowell Connection | Conduit Connection | Material | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Overall Lg. | Head | Fitting | Each | |
304 Stainless Steel Probe and Thermowell | |||||||||||||||||
100 ohms | -55° to 400° | 6" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 14 1/8" | Cast Iron | Iron | 0000000 | 0000000 |
100 ohms | -55° to 400° | 9" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 17 1/8" | Cast Iron | Iron | 0000000 | 000000 |
100 ohms | -55° to 400° | 12" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 20 1/8" | Cast Iron | Iron | 0000000 | 000000 |
Cut-to-Length RTD Probes for Liquids and Gases

For a perfect fit in a thermowell, trim these probes with a pipe cutter. Stainless steel protects the sensing element from impact and liquids when they’re immersed. They are often installed in a bore to measure the temperature of molds, dies, and other equipment.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 72" | 1/4" | 68 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 96" | 1/4" | 92 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 900° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
Dual-Output Cut-to-Length RTD Probes for Liquids and Gases

Output temperature readings to two devices, or in applications where you want to output temperature readings to two different devices. For example, the output from one thermocouple might be fed to a data logger, while the output from the other thermocouple is used for process control.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
RTD Probes for Air

Use these RTD probes for more stable air-temperature readings than thermocouple probes.
Probe | Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Max. Cable Temperature, ° F | Lead Lg. | Gauge | Each | |
Platinum Probe | ||||||||||||
PTFE Cable | ||||||||||||
100 ohms | -55° to 400° | 5/8" | 1/8" | ±0.12% | 5 | 3 | Wire Leads | 400° | 1/2" | 24 | 0000000 | 000000 |
100 ohms | -55° to 400° | 5/8" | 1/8" | ±0.12% | 5 | 6 | Wire Leads | 400° | 1/2" | 24 | 0000000 | 00000 |
Fiberglass Cable | ||||||||||||
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 3 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 6 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 10 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 25 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
Sanitary RTD Probes for Liquids and Gases
Designed for clean-in-place applications such as dairy processing and food-preparation areas, these 3-A certified RTDs have a sanitary quick-clamp connection for easy removal. Remove the cap on the head to wire the probe’s terminal block to your application.
For technical drawings and 3-D models, click on a part number.

Probe | Conduit Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Overall Lg. | Each | |
316 Stainless Steel Probe with Plastic Head | |||||||||||||
For 1 1/2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 1.984" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 0000000 |
For 2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 2.516" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 000000 |
Threaded RTD Probe Transmitters for Liquids and Gases
Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in 4-20mA transmitter, these RTDs don’t require a separate signal converter. They have an NPT male probe connection, so they’re ready to screw into thermowells and other fittings on pipe and tanks. Made of 316 or 316L stainless steel, they resist corroding from harsh cleaning chemicals. This stainless steel also protects the RTD sensor inside from impact. They are also often installed in bores to measure the temperature of molds and dies. CE marked, they meet European safety standards.
RTDs with a screw terminal connection have a cap you can remove to wire the RTD’s terminal block to your application.
Fixed RTDs can be used directly in liquid or steam because they’re welded to their fitting for a liquid-tight seal.
Spring-loaded RTDs are not liquid-tight, so they must be installed in a thermowell or protection tube. The spring inside the fitting pushes the probe against the thermowell to provide an accurate reading.
RTDs with IO Link let you remotely adjust settings, read measurements, and receive error messages when connected to a PLC via an IO Link controller (not included). These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. UL and C-UL listed, they meet American and Canadian safety standards.
For technical drawings and 3-D models, click on a part number.

Probe | Probe Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Lg. | Dia. | Accuracy | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Fitting Material | Choose a Temperature Range | Each | |
Fixed 316 Stainless Steel Probe with Plastic Head (IP65) | ||||||||||||||
100 ohms | 1 3/4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 5 3/4" | 316 Stainless Steel | 000000 | 0000000 | |
100 ohms | 3 1/4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 7 1/4" | 316 Stainless Steel | 000000 | 000000 | |
100 ohms | 5 1/4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 9 1/4" | 316 Stainless Steel | 000000 | 000000 | |
100 ohms | 8 1/4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 12 1/4" | 316 Stainless Steel | 000000 | 000000 | |
100 ohms | 11 1/4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 15 1/4" | 316 Stainless Steel | 0000000 | 000000 |

Probe Transmitters | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Probe Connection | Cables with Socket | ||||||||||||||||
RTD Type | Lg. | Dia. | Accuracy | Response Time, sec. | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Communication Protocol | Overall Lg. | Fitting Material | Temp. Range, °F | Each | Each | ||
Fixed 316L Stainless Steel Probe (IP67, IP68, IP69K) | ||||||||||||||||||
1,000 ohms | 11/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 5,800 | 4-20mA | IO Link | 4 1/8" | 316L Stainless Steel | 0° to 300° | 0000000 | 0000000 | 0000000 | 000000 |
1,000 ohms | 1 1/2" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 5" | 316L Stainless Steel | 0° to 300° | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 3 1/2" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 7" | 316L Stainless Steel | 0° to 300° | 0000000 | 000000 | 0000000 | 00000 |
1,000 ohms | 5 7/16" | 1/4" | ±0.5% | 3 | 1/2 | NPT | Male | 18-32 | 4,350 | 4-20mA | IO Link | 8 7/8" | 316L Stainless Steel | 0° to 300° | 0000000 | 000000 | 0000000 | 00000 |

Probe Transmitters | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Probe Connection | Conduit Connection | Replacement Elements | |||||||||||||||||
RTD Type | Lg. | Dia. | Accuracy | Response Time, sec. | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure | Output Current | Overall Lg. | Fitting Material | Choose a Temperature Range | Each | Each | ||
Spring-Loaded 316 Stainless Steel Probe with Aluminum Head | ||||||||||||||||||||
100 ohms | 3 3/4" | 1/4" | ±0.1% | 6 | 1/2 | NPT | Male | 3/4 | NPT | Female | 10-30 | Not Rated | 4-20mA | 9" | 316 Stainless Steel | 0000000 | 0000000 | 00000000 | 0000000 | |
100 ohms | 5 3/4" | 1/4" | ±0.1% | 6 | 1/2 | NPT | Male | 3/4 | NPT | Female | 10-30 | Not Rated | 4-20mA | 11" | 316 Stainless Steel | 0000000 | 000000 | 00000000 | 000000 | |
100 ohms | 8 3/4" | 1/4" | ±0.1% | 6 | 1/2 | NPT | Male | 3/4 | NPT | Female | 10-30 | Not Rated | 4-20mA | 14" | 316 Stainless Steel | 0000000 | 000000 | 00000000 | 000000 | |
100 ohms | 11 3/4" | 1/4" | ±0.1% | 6 | 1/2 | NPT | Male | 3/4 | NPT | Female | 10-30 | Not Rated | 4-20mA | 17" | 316 Stainless Steel | 0000000 | 000000 | 00000000 | 000000 |
Threaded RTD Probe Transmitters with Digital Display for Liquids and Gases
View temperature readings and adjust settings directly on these RTD probe transmitters. To communicate with programmable logic controllers (PLCs), they have a built-in transmitter with two outputs. One output can send a digital switching signal or use IO Link protocol with the addition of an IO Link controller (not included). The other can send a digital switching signal or a 4-20mA analog signal. The different output options make these RTDs good for a wide range of uses, including operating far away from a controller, taking automated measurements, and providing inputs to switching applications. All have an NPT threaded fitting welded onto the probe, so they’re ready to screw into containers, tanks, and pipes. Probe length is fixed. Made of 316L stainless steel, they are highly corrosion resistant.
These RTDs meet DIN EN 60751 Class A standards for temperature accuracy. UL Listed, C-UL Listed, and CE Marked, all meet American, Canadian, and European safety standards.
For technical drawings and 3-D models, click on a part number.

Probe | Configurable Digital Output | Configurable Analog/Digital Output | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temp. Range, °F | Lg. | Dia. | Accuracy | Response Time, sec. | Plug Type | Probe Connection Pipe Size | Max. Pressure, psi | No. of | Communication Protocol | Signal Type | No. of | Current | Signal Type | Overall Lg. | Each | |
NPT Male Probe Connection | |||||||||||||||||
316L Stainless Steel Probe with Plastic Head (IP67) | |||||||||||||||||
1,000 ohms | -55° to 300° | 1/2" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/4 | 5,800 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 4 7/8" | 0000000 | 0000000 |
1,000 ohms | -55° to 300° | 1/2" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 4,350 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 4 7/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 1 1/4" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/4 | 5,800 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 5 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 1 1/4" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 4,350 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 5 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 3 1/4" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 3,625 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 7 5/8" | 0000000 | 000000 |
1,000 ohms | -55° to 300° | 5 3/16" | 1/4" | ±0.75% | 3 | 4-Pole Micro M12 | 1/2 | 3,625 | 1 | IO Link | NPN/PNP | 1 | 4-20mA | NPN/PNP | 9 1/2" | 0000000 | 000000 |

Cable Lead Lg., ft. | Voltage | Current | Face Diameter | Each | |
12 | 250V AC/250V DC | 4A | 0.3" | 0000000 | 000000 |
Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gases
Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're made of stainless steel, so they won't corrode from harsh cleaners and sanitizers. The housing is IP69K rated, meaning it withstands high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. They have a flange that will connect to sanitary quick-clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
Program these probes with the touch screen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet DIN EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
For technical drawings and 3-D models, click on a part number.


Probe | Probe Transmitters | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Plug Type | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe with 304 Stainless Steel Head (IP69K) | |||||||||||||||
For 1 1/2" Tube OD | |||||||||||||||
100 ohms | -55° to 480° | 2" | 5/16" | 1.988" | ±0.1% | 25 | 5-Pole Micro M12 | 8-35 | 580 | 4-20mA | 6 3/4" | 0000000 | 0000000 | 0000000 | 000000 |
RTD Transmitters
Convert signals from your RTD probe into signal types that data loggers, controllers, and other instruments can read.
For technical drawings and 3-D models, click on a part number.

(Connection Head and
Probe Not Included)

For RTD Probe Type | Temperature Range, °F | Ht. | Wd. | Dp. | DC Voltage | Output Current | Housing Material | For Max. Wire Gauge | Each | |
Oblong | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Screw Terminals | ||||||||||
100 ohms | 0° to 100° | 1 1/2" | 2 3/16" | 7/8" | 10-30 | 4-20mA | Plastic | 15 | 00000000 | 0000000 |
100 ohms | 0° to 200° | 1 1/2" | 2 3/16" | 7/8" | 10-30 | 4-20mA | Plastic | 15 | 00000000 | 000000 |
100 ohms | 0° to 300° | 1 1/2" | 2 3/16" | 7/8" | 10-30 | 4-20mA | Plastic | 15 | 00000000 | 000000 |
100 ohms | 0° to 400° | 1 1/2" | 2 3/16" | 7/8" | 10-30 | 4-20mA | Plastic | 15 | 00000000 | 000000 |
Thermocouple and RTD Connection Heads


Attach these heads to your thermocouple or RTD probe to protect wiring from dust and moisture. The removable cap makes it easy to access your wiring when you need. Install an optional terminal block inside the head to keep your wiring organized.
Hazardous location connection heads are rated for use in Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 environments with flammable gases, combustible dust, and combustible fibers.
Probe Connection | Conduit Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Includes | Environment | Environmental Rating | Each | |
Aluminum | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 000000 |
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | Hazardous Location | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 4X | 00000000 | 000000 |
Cast Iron | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 00000 |
Plastic | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Hinged Cap | __ | __ | 00000000 | 00000 |
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 00000 |
Stainless Steel | ||||||||||
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | __ | __ | 00000000 | 000000 |
1/2 | NPT | Female | 3/4 | NPT | Female | Screw-On Cap with Retaining Chain | Hazardous Location | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIC, IIB, IIA NEC Zone 21 Groups IIIC, IIIB, IIIA IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IP66 | 00000000 | 000000 |
Terminal Blocks for Thermocouple and RTD Connection Heads


Connect thermocouples and RTDs to extension wire and instrumentation. These terminal blocks mount inside a connection head and work with any thermocouple or RTD probe type. Choose one with enough circuits to accommodate your probe. Make sure to connect extension wire that matches your probe type.
For technical drawings and 3-D models, click on a part number.
Mounting Slot | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits | For Max. Wire Gauge | Max. Temperature, °F | Dia. | Ht. | Wd. | Dp. | Material | Mounting Fasteners Included | No. of | Ht. | Wd. | Each | |
Round | |||||||||||||
Screw Terminals | |||||||||||||
2 | 14 | 1000° | 1 15/16" | __ | __ | 3/4" | Ceramic | Yes | 2 | 3/16" | 5/16" | 0000000 | 000000 |
3 | 14 | 1000° | 1 15/16" | __ | __ | 3/4" | Ceramic | Yes | 2 | 3/16" | 5/16" | 0000000 | 00000 |
4 | 14 | 1000° | 1 15/16" | __ | __ | 3/4" | Ceramic | Yes | 2 | 3/16" | 5/16" | 0000000 | 00000 |
6 | 14 | 1000° | 1 15/16" | __ | __ | 3/4" | Ceramic | Yes | 2 | 3/16" | 5/16" | 0000000 | 00000 |
Oblong | |||||||||||||
Screw Terminals | |||||||||||||
2 | 14 | 1000° | __ | 1 3/8" | 2" | 1" | Ceramic | Yes | 2 | 3/16" | 9/16" | 00000000 | 00000 |
3 | 14 | 1000° | __ | 1 3/8" | 2" | 1" | Ceramic | Yes | 2 | 3/16" | 9/16" | 00000000 | 00000 |
4 | 14 | 1000° | __ | 1 3/8" | 2" | 1" | Ceramic | Yes | 2 | 3/16" | 9/16" | 0000000 | 00000 |
6 | 14 | 1000° | __ | 1 3/8" | 2" | 1" | Ceramic | Yes | 2 | 3/16" | 9/16" | 0000000 | 00000 |
Spring-Loaded Thermocouple and RTD Fittings

Add threads to unthreaded probes so they can be installed into thermowells, protection tubes, and housings. These fittings have a spring inside that pushes the probe forward, ensuring the tip makes proper contact with the surface being measured for accurate temperature measurement.
To install, slide the fitting over your probe. The bottom threads into your process and the top can be threaded to a connection head. Note that the bottom is not liquid tight, so these fittings should not be used to thread a probe directly into fluids. To measure the temperature of fluids, first install a thermowell into your process, then use these fittings to thread the probe into the thermowell.
Fittings with a fluoroelastomer O-ring prevent splashing liquid and moisture from getting inside your connection head. However, the seal can't stand up to pressurized liquids and submersion.
For Probe OD | Pipe Size | Overall Lg. | O-Ring Material | Material | Each | |
1/4" | 1/2 NPT Male × 1/2 NPT Male | 2 1/16" | Fluoroelastomer Rubber | Stainless Steel | 00000000 | 000000 |